• Title/Summary/Keyword: DISTANCE OF MOVEMENT

Search Result 933, Processing Time 0.028 seconds

Structural Relationships Among Factors to Adoption of Telehealth Service (원격의료서비스 수용요인의 구조적 관계 실증연구)

  • Kim, Sung-Soo;Ryu, See-Won
    • Asia pacific journal of information systems
    • /
    • v.21 no.3
    • /
    • pp.71-96
    • /
    • 2011
  • Within the traditional medical delivery system, patients residing in medically vulnerable areas, those with body movement difficulties, and nursing facility residents have had limited access to good healthcare services. However, Information and Communication Technology (ICT) provides us with a convenient and useful means of overcoming distance and time constraints. ICT is integrated with biomedical science and technology in a way that offers a new high-quality medical service. As a result, rapid technological advancement is expected to play a pivotal role bringing about innovation in a wide range of medical service areas, such as medical management, testing, diagnosis, and treatment; offering new and improved healthcare services; and effecting dramatic changes in current medical services. The increase in aging population and chronic diseases has caused an increase in medical expenses. In response to the increasing demand for efficient healthcare services, a telehealth service based on ICT is being emphasized on a global level. Telehealth services have been implemented especially in pilot projects and system development and technological research. With the service about to be implemented in earnest, it is necessary to study its overall acceptance by consumers, which is expected to contribute to the development and activation of a variety of services. In this sense, the study aims at positively examining the structural relationship among the acceptance factors for telehealth services based on the Technology Acceptance Model (TAM). Data were collected by showing audiovisual material on telehealth services to online panels and requesting them to respond to a structured questionnaire sheet, which is known as the information acceleration method. Among the 1,165 adult respondents, 608 valid samples were finally chosen, while the remaining were excluded because of incomplete answers or allotted time overrun. In order to test the reliability and validity of the assessment scale items, we carried out reliability and factor analyses, and in order to explore the causal relation among potential variables, we conducted a structural equation modeling analysis using AMOS 7.0 and SPSS 17.0. The research outcomes are as follows. First, service quality, innovativeness of medical technology, and social influence were shown to affect perceived ease of use and perceived usefulness of the telehealth service, which was statistically significant, and the two factors had a positive impact on willingness to accept the telehealth service. In addition, social influence had a direct, significant effect on intention to use, which is paralleled by the TAM used in previous research on technology acceptance. This shows that the research model proposed in the study effectively explains the acceptance of the telehealth service. Second, the research model reveals that information privacy concerns had a insignificant impact on perceived ease of use of the telehealth service. From this, it can be gathered that the concerns over information protection and security are reduced further due to advancements in information technology compared to the initial period in the information technology industry, and thus the improvement in quality of medical services appeared to ensure that information privacy concerns did not act as a prohibiting factor in the acceptance of the telehealth service. Thus, if other factors have an enormous impact on ease of use and usefulness, concerns over these results in the initial period of technology acceptance may become irrelevant. However, it is clear that users' information privacy concerns, as other studies have revealed, is a major factor affecting technology acceptance. Thus, caution must be exercised while interpreting the result, and further study is required on the issue. Numerous information technologies with outstanding performance and innovativeness often attract few consumers. A revised bill for those urgently in need of telehealth services is about to be approved in the national assembly. As telemedicine is implemented between doctors and patients, a wide range of systems that will improve the quality of healthcare services will be designed. In this sense, the study on the consumer acceptance of telehealth services is meaningful and offers strong academic evidence. Based on the implications, it can be expected to contribute to the activation of telehealth services. Further study is needed to assess the acceptance factors for telehealth services, such as motivation to remain healthy, health care involvement, knowledge on health, and control of health-related behavior, in order to develop unique services according to the categorization of customers based on health factors. In addition, further study may focus on various theoretical cognitive behavior models other than the TAM, such as the health belief model.

The moment generated by the torque of the orthodontic rectangular wire : Three-dimensional finite element analysis (교정용 각형선재에 부여된 torque가 브라켓에 발생시키는 모멘트에 관한 유한요소법적 분석)

  • Ha, Do-Won;Kim, Young-Suk;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.31 no.3 s.86
    • /
    • pp.335-346
    • /
    • 2001
  • The purpose of this study was to investigate the ideal clinical torque(In the SWA rectangular wire, the torque by the angle between the plane part and twisted part to move the tooth) of the orthodontic rectangular wire which produce the proper labiolingual movement of the single tooth during finishing stage of the orthodontic treatment. The clinical torque is the sum of the play and the active torque which generates the moment at the bracket. The play is calculated by the formula and the active torque is calculated by the computer aided three-dimensional finite element method. The finite element model was consist of the three brackets which formed a row and 3 kinds of orthodontic rectangular wire(stainless steel, TMA, NiTi) which inserted in brackets. Both sides of the model were twisted and the moment generated in the center bracket was calculated. The sizes of seven wires which were used commonly were .016'X.022', .017'X.022', .017'X.025', .018'X.025', .019'X.025', .020'X.025', .021'X.025'. In 018' bracket, 016'X.022', .017'X.022', .017'X.025' wires were inserted and in 022' bracket, all the sizes of wires except .016'X.022' were inserted and tested. The following conclusions could be drawn from this study. 1. The moments generated on the same size of the wires by the same active torque were equal regardless of the bracket slot size. 2. The moments were increased with the size of the wires. The moment generated on the .021'X.025' wire was about 1.75 times as large as that on the .016'X.022' wire regardless of the material. 3. The moments were increased in the order of the NiTi, TMA stainless steel. The moment of the TMA wire was 0.35 times as small as that of the stainless steel wire and the moment of the NiTi was0.16 times as small as that of the stainless steel wire. 4. The moment was decreased as the interbracket distance was increased. 5. To get a desired moment with the specific size and material of the wire on the specific bracket slot, the formula and the results were displayed.

  • PDF

Effects of Change in Patient Position on Radiation Dose to Surrounding Organs During Chest Lateral Radiography with Auto Exposure Control Mode (자동노출제어장치를 적용한 흉부 측면 방사선검사 시 환자 위치 변화가 주변 장기의 선량에 미치는 영향)

  • Seung-Uk Kim;Cheong-Hwan Lim;Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.903-909
    • /
    • 2023
  • The purpose of this study is to compare and analyze the effect of changes in the patient's central position on the exposure dose and image quality of surrounding organs during a chest lateral examination using an Auto Exposure Control(AEC). The experiment was conducted on a human body phantom. A needle was attached to the lower part of the center of the coronal plane of the phantom, and a lead ruler was attached to the lower part of the detector so that the 50 cm point was located at the lower center of the AEC ion chamber. The exposure conditions were 125 kVp, 320 mA, the distance between the source and the image receptor was 180 cm, and the exposure field size was 14 × 17 inches. Only one AEC ion chamber was used at the bottom center, and the density was set to '0' and sensitivity to 'Middle', and the central X-ray was incident vertically toward the 6th thoracic vertebra. With AEC mode applied, the 50 cm point of the needle and lead ruler were aligned and the phantom was moved 5 cm toward the stomach (F5) and 5 cm toward the back (B5), and the dose factor was analyzed by measuring ESD. The ESD of the thyroid gland according to the change in patient center position was 232.60±2.20 μGy for Center, 231.22±1.53 μGy for F5, and 184.37±1.19 μGy for B5, and the ESD of the breast was 288.54±3.03 μGy for Center, F5 was 260.97±1.93 μGy, B5 was 229.80±1.62 μGy, and the ESD of the center of the lung was 337.02±3.25 μGy for Center, F5 was 336.09±2.29 μGy, and B5 was 261.76±1.68 μGy. As a result of comparing the average values of dose factors between each group, the difference in average values was statistically significant (p<0.01), and each group appeared to be independent. As a result of the study, there was no significant difference in the dose to the thyroid, breast, and center of the lung according to the change in the patient's central position, except for the breast (10%) when the patient moved forward about 5 cm. However, movement of about 5 cm posteriorly resulted in an average dose reduction of 23.7%. Additionally, when the patient's central position was moved to the rear, image quality deteriorated.

An Analysis of Factors That Affect Image Quality Deterioration in The Potable X-ray Examination on using Digital Wireless Detector (디지털 무선 검출기를 이용한 이동형 X선검사에서 영상품질 저하의 요인분석)

  • Yu, Young-Eun;Lim, Cheong-Hwan;Ko, Joo-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.93-100
    • /
    • 2014
  • Recently the development of portable digital wireless imaging system, which acquires digital radiation images by using wireless LAN telecommunications function in an easy and fast way, provides lots of convenience for people. Considering the characteristics of portable imaging tests on emergency and critical patients, this study aims to suggest guidelines for Digital wireless detector by evaluating the effect of de-centering of focus-grid and displacement of subject in detector on the quality of image. The equipments used for this study were Elmo-T6 Digital Mobile X-ray system (SIMAZU Corp.), el' Tor ($14{\times}17$ "Wireless detector), Grid (10:1) and Chest & head phantom. After acquiring post-processing image according to dose increase and de-centering image of grid-focus and head phantom displacement image, this study compared, analyzed and evaluated these images by using a digital image analysis program by Image J. In the change of images based on dose increase, images were rough in the dose of 0.5 mAs, while there was no difference among images in the proper dose of 1~2 mAs and, especially from 2.5 mAs, average value of pixels radically decreased, affecting contrast. Over 3 mAs, contrast dropped due to saturation phenomenon of lungs. As the result of analysis using Image J program, with the increase of displacement between focus-grid and head phantom, the frequency of low pixel value also increase, causing the outline of surface image to disappear, which in turn affects contrast. For better quality imaging, a radiographer must be aware before the time of test that the image quality can be changed based on the critical patient's posture, movement, respiration, displacement of X-ray tube and distance of imaging.

A Study on the Arrangement and Design of Cultural Property Signs - Focused on the Seoul Tangible Cultural Properties Located in Jongno-gu Area - (문화재 안내판의 배치와 디자인에 대한 고찰 - 종로구 소재 서울 유형문화재를 중심으로 -)

  • So, Hyun-Su;Kim, Hai-Gyoung
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.30 no.1
    • /
    • pp.66-75
    • /
    • 2012
  • The Seoul Metropolitan Government selected the sign designs of cultural heritages through a public prize contest from a public design perspective and applied the selected design format to the signs of the cultural assets that were designated by the central and Seoul governments and located in Seoul Metropolitan area in 2008. For the purpose of monitoring the result, this study analyzed the installation state of the signs of Seoul tangible cultural properties located in Jongno-gu. The scope of the analysis of this study was expanded to cover the surrounding areas of cultural heritages in order to review the arrangement and design of such signs. The result of this study can be summarized as follows; firstly, not only the flow of travelers' movement but also the direction of sight, their locations in relation to the surrounding facilities or other installations and the integration with similar signs or notices were necessary to be considered in the arrangement of the signs; secondly, the current sings had low quality in terms of durability and readability and seemed utterly distance from the cultural assets indicated by the signs because they were finished with tempered glass; thirdly, the size, shape and materials of the signs were not harmonized with their surrounding areas as only one design was used in the entire cultural property sites without considering such natural or artificial backgrounds of individual signs as rocks, plants, walls or buildings. When selecting the design format of the signs of individual cultural properties that are located dispersively as Seoul tangible cultural properties, it is recommended to determine a group of most representative designs based on natural, man-made and cultural landscape rather than one unified design format and to use a unique well-matched sign for each cultural property. For this reason, this study selected alternative exemplary design models and proposed the type of signs appropriate for each cultural site.

The Investigation Image-guided Radiation Therapy of Bladder Cancer Patients (방광암 환자의 영상유도 방사선치료에 관한 고찰)

  • Bae, Seong-Soo;Bae, Sun-Myoung;Kim, Jin-San;Kang, Tae-Young;Back, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.39-43
    • /
    • 2012
  • Purpose: In hospital image-guided radiation therapy in patients with bladder cancer to enhance the reproducibility of the appropriate amount, depending on the patient's condition, and image-guided injection of saline system (On-Board Imager system, OBI, VARIAN, USA) three of the Cone-Beam CT dimensional matching (3D-3D matching) to be the treatment. In this study, the treatment of patients with bladder cancer at Cone-Beam CT image obtained through the analysis of the bones based matching and matching based on the bladder to learn about the differences, the bladder's volume change injected saline solution by looking at the bladder for the treatment of patients with a more appropriate image matching is to assess how the discussion. Materials and Methods: At our hospital from January 2009 to April 2010 admitted for radiation therapy patients, 7 patients with bladder cancer using a Folly catheter of residual urine in the bladder after removing the amount determined according to individual patient enough to inject saline CT-Sim was designed after the treatment plan. After that, using OBI before treatment to confirm position with Cone-Beam CT scan was physician in charge of matching was performed in all patients. CBCT images using a total of 45 bones, bladder, based on image matching and image matching based on the difference were analyzed. In addition, changes in bladder volume of Eclipse (version 8.0, VARIAN, USA) persuaded through. Results: Bones, one based image matching based on the bladder and re-matching the X axis is the difference between the average $3{\pm}2mm$, Y axis, $1.8{\pm}1.3mm$, Z-axis travel distance is $2.3{\pm}1.7mm$ and the overall $4.8{\pm}2.0mm$, respectively. The volume of the bladder compared to the baseline showed a difference of $4.03{\pm}3.97%$. Conclusion: Anatomical location and nature of the bladder due to internal movement of the bones, even after matching with the image of the bladder occurred in different locations. In addition, the volume of saline-filled bladder showed up the difference between the 4.03 percent, but matched in both images to be included in the planned volumes were able to confirm. Thus, after injection of saline into the bladder base by providing a more accurate image matching will be able to conduct therapy.

  • PDF

Performance Evaluation of Monitoring System for Sargassum horneri Using GOCI-II: Focusing on the Results of Removing False Detection in the Yellow Sea and East China Sea (GOCI-II 기반 괭생이모자반 모니터링 시스템 성능 평가: 황해 및 동중국해 해역 오탐지 제거 결과를 중심으로)

  • Han-bit Lee;Ju-Eun Kim;Moon-Seon Kim;Dong-Su Kim;Seung-Hwan Min;Tae-Ho Kim
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_2
    • /
    • pp.1615-1633
    • /
    • 2023
  • Sargassum horneri is one of the floating algae in the sea, which breeds in large quantities in the Yellow Sea and East China Sea and then flows into the coast of Republic of Korea, causing various problems such as destroying the environment and damaging fish farms. In order to effectively prevent damage and preserve the coastal environment, the development of Sargassum horneri detection algorithms using satellite-based remote sensing technology has been actively developed. However, incorrect detection information causes an increase in the moving distance of ships collecting Sargassum horneri and confusion in the response of related local governments or institutions,so it is very important to minimize false detections when producing Sargassum horneri spatial information. This study applied technology to automatically remove false detection results using the GOCI-II-based Sargassum horneri detection algorithm of the National Ocean Satellite Center (NOSC) of the Korea Hydrographic and Oceanography Agency (KHOA). Based on the results of analyzing the causes of major false detection results, it includes a process of removing linear and sporadic false detections and green algae that occurs in large quantities along the coast of China in spring and summer by considering them as false detections. The technology to automatically remove false detection was applied to the dates when Sargassum horneri occurred from February 24 to June 25, 2022. Visual assessment results were generated using mid-resolution satellite images, qualitative and quantitative evaluations were performed. Linear false detection results were completely removed, and most of the sporadic and green algae false detection results that affected the distribution were removed. Even after the automatic false detection removal process, it was possible to confirm the distribution area of Sargassum horneri compared to the visual assessment results, and the accuracy and precision calculated using the binary classification model averaged 97.73% and 95.4%, respectively. Recall value was very low at 29.03%, which is presumed to be due to the effect of Sargassum horneri movement due to the observation time discrepancy between GOCI-II and mid-resolution satellite images, differences in spatial resolution, location deviation by orthocorrection, and cloud masking. The results of this study's removal of false detections of Sargassum horneri can determine the spatial distribution status in near real-time, but there are limitations in accurately estimating biomass. Therefore, continuous research on upgrading the Sargassum horneri monitoring system must be conducted to use it as data for establishing future Sargassum horneri response plans.

A study on the search and selection processes of targets presented on the CRT display (컴퓨터 모니터에 제시된 표적의 탐색과 선택과정에 관한 연구)

  • 이재식;신현정;도경수
    • Korean Journal of Cognitive Science
    • /
    • v.11 no.2
    • /
    • pp.37-51
    • /
    • 2000
  • The present study compared computer users target-selection response patterns when the targets were varied in terms of their relative location and distance from the current position of the cursor. In Experiment 1, where the mouse was used as an input device, the effects of different directions and distances of simple target(small rectangle) on target-selection response were investigated. The results of Experiment 1 can be summarized as follows: (1) Overshooting was more frequent than either undershooting or correct movement and (2) this tendency was more prominent when the targets were presented in the oblique direction or in farther location from the current cursor position. (3) Although the overshooting and undershooting were more frequent in the oblique direction, the degree of deviation was larger in horizontal and vertical direction. (4) Time spent in moving the mouse rather than that spent in planning, calibrating or clicking was found to be the most critical factor in determining total response time. In Experiment 2, effects of the font size and line-height of the target on target-selection response were compared with regard to two types of input devices(keyboard vs. mouse). The results are as follows: (1) Mouse generally yielded shorter target-selection time than keyboard. but this tendency was reversed when the targets were presented in horizontal and vertical directions. (2) In general, target-selection time was the longest in the condition of font size of 10 and line-height of 100%, and the shortest in the condition of font size of 12 and line-height of 150%. (3) When keyboard was used as the input device, target-selection time was shortest in the 150% line-height condition, whereas in the mouse condition, target-selection time tended to be increased as the line-height increased. which resulted in the significant interaction effect between input device and line-height. Finally, several issues relating to human-computer interaction were discussed based on the results of the present study.

  • PDF

Evaluation on the Radiation Exposure of Radiation Workers in Proton Therapy (양성자 치료 시 방사선 작업 종사자에게 미치는 방사선 피폭에 대한 평가)

  • Lee, Seung-Hyun;Jang, Yo-Jong;Kim, Tae-Yoon;Jeong, Do-Hyung;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.107-114
    • /
    • 2012
  • Purpose: Unlike the existing linear accelerator with photon, proton therapy produces a number of second radiation due to the kinds of nuclide including neutron that is produced from the interaction with matter, and more attention must be paid on the exposure level of radiation workers for this reason. Therefore, thermoluminescence dosimeter (TLD) that is being widely used to measure radiation was utilized to analyze the exposure level of the radiation workers and propose a basic data about the radiation exposure level during the proton therapy. Materials and Methods: The subjects were radiation workers who worked at the proton therapy center of National Cancer Center and TLD Badge was used to compare the measured data of exposure level. In order to check the dispersion of exposure dose on body parts from the second radiation coming out surrounding the beam line of proton, TLD (width and length: 3 mm each) was attached to on the body spots (lateral canthi, neck, nipples, umbilicus, back, wrists) and retained them for 8 working hours, and the average data was obtained after measuring them for 80 hours. Moreover, in order to look into the dispersion of spatial exposure in the treatment room, TLD was attached on the snout, PPS (Patient Positioning System), Pendant, block closet, DIPS (Digital Image Positioning System), Console, doors and measured its exposure dose level during the working hours per day. Results: As a result of measuring exposure level of TLD Badge of radiation workers, quarterly average was 0.174 mSv, yearly average was 0.543 mSv, and after measuring the exposure level of body spots, it showed that the highest exposed body spot was neck and the lowest exposed body spot was back (the middle point of a line connecting both scapula superior angles). Investigation into the spatial exposure according to the workers' movement revealed that the exposure level was highest near the snout and as the distance becomes distant, it went lower. Conclusion: Even a small amount of exposure will eventually increase cumulative dose and exposure dose on a specific body part can bring health risks if one works in a same location for a long period. Therefore, radiation workers must thoroughly manage exposure dose and try their best to minimize it according to ALARA (As Low As Reasonably Achievable) as the International Commission on Radiological Protection (ICRP) recommends.

  • PDF

Analyses of the Setup Errors using on Board Imager (OBI) (On Board Imager (OBI)를 이용한 Setup Error 분석에 대한 연구)

  • Kim, Jong-Deok;Lee, Haeng-O;You, Jae-Man;Ji, Dong-Hwa;Song, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • Purpose: The accuracy and advantages of OBI(On Board Imager) against the conventional method like film and EPID for the setup error correction were evaluated with the analysis of the accumulated data which were produced in the process of setup error correction using OBI. Materials and Methods: The results of setup error correction using OBI system were analyzed for the 130 patients who had been planned for 3 dimensional conformal radiation therapy during March 2006 and May 2006. Two kilo voltage images acquired in the orthogonal direction were fused and compared with reference setup images. The setup errors in the direction of vertical, lateral, longitudinal axis were recorded and calculated the distance from the isocenter. The corrected setup error were analyzed according to the lesion and the degree of shift variations. Results: There was no setup error in the 41.5% of total analyzed patients and setup errors between 1mm and 5mm were found in the 52.3%. 6.1% patients showed the more than 5mm shift and this error were verified as a difference of setup position and the movement of patient in a treatment room. Conclusion: The setup error analysis using OBI in this study verified that the conventional setup process in accordance with the laser and field light was not enough to get rid of the setup error. The KV images acquired using OBI provided good image quality for comparing with simulation images and much lower patients' exposure dose compared with conventional method of using EPID. These advantages of OBI system which were confirmed in this study proved the accuracy and priority of OBI system in the process of IGRT(Image Guided Radiation Therapy).

  • PDF