• Title/Summary/Keyword: DIFFERENCE OF ALTITUDE

Search Result 299, Processing Time 0.029 seconds

The Study of Maternal Characteristics of Low Birth-Weight Infant (저체중아 출생과 관련된 산모의 특성 연구)

  • Hong, Pil-Soon;Park, Kyoung-Sook
    • Women's Health Nursing
    • /
    • v.5 no.1
    • /
    • pp.80-95
    • /
    • 1999
  • The purpose of this study was to investigate the characteristics of low birth-weight infants and their's mothers, and to identify the factors which influenced to delivery of L.B.W infants. The data derived from K. General Hospital and J. obs & gyn clinic in pusan from January, 1998 to August, 1998, which were from mothers of having B. W infants. The factors used for this study were characteristics of general, obstetrical, environmental aspects and physical and psychological life experiences during pregnancy. Analysis of data obtained were computerized statistically by using SPSS 7.5 WIN program. the data were analysed as number, frequency, percentage, t-test and ANOVA. The major results obtained of this study were as follows : 1) Gender that L.B.W infants were male in 47.2% and female in 52.8%, body weight of 2001~2500gm was above 8 in 68.5%, and below 5 in 1.8%. The L.B.W infants with complications were 7, which were 6.5%. The kinds of malformations were the Cleft palate & lip, Hyper-kalemia, Hypoglycemia, Meningocele, CHD, Down syndrome and each of them marked 0.9%. 2) In the general characteristics of pregnant women, the age group of 25~29 years was the most common as 46.3%. Over 35 years of age, elderly gravidas were in 7.5%. the height of 156~160cm was the most common as 52.8%. pregnant women of below 150cm height was in 3.7%. body weight of 51~55kg was the most common as 38%. pregnant women of below 45kg were in 19.4%. The women with smoking and drinking episodes during pregnancy were 1.9% and 25%. In the status of marriage, married women were in 95.4%, unmarried ones were in 1.9%, and unmarried couples were in 2.8%. Iin he obstetrical characteristics of pregnant women, pregnant women with gestational age under 37wks were in 45.4%, and the ones over 38wks were 54.6%. At the methods of delivery, normal spontaneous vaginal deliveries were in 51.9%, which were the most common, cesarian section deliveries were in 47.2%, and breech deliveries were in 0.9%. In the environmental characteristics of pregnant women, 40.8% of pregnant women lived in house or apartments with stairs, 23.1% of them lived in the high altitude. the pregnant women who ran a household without a helper were in 65.7%. In the pregnant women who had underwent life experiences of physical and psychological stress during pregnancy. life experiences of physical stresses were described as persistent fatigue due to lifestyle, traumatic experience, illness, move away with an effort, physical impact caused by discord. life experiments of psychological stresses were describeded as trouble with their husbands, discord with one's husband family, family problems, and conflicts due to environmental factors, etc. The number of the pregnant women who had complications during pregnancy was 32, which was 29.6% totally. Among them, pre-eclampsia was in 12.1% and the premature rupture of membrane in 7.4%. 3) In the analysis of the general, obstetrical, and circumstantial characteristics and L.B.W infants. There were statistical difference significantly between the gestational age of pregnant women(F=12.035, P=.000), and the status of marriage(F=3.207, P=.044), and maternal complication(t=2.344, P=.021) etc.

  • PDF

Physiological analysis of mountain climbing exercise (등산운동의 생리학적 분석)

  • Kim, Wan-Tai;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.5 no.2
    • /
    • pp.15-27
    • /
    • 1971
  • Physiological analysis of the physical exercise was made on 9 subjects performing mountain climbing. The course between two points (256 and 516 meters altitude) was 1,300 meters in distance and difference of vertical height was 260 meters making the mean grade of 20%. In the field, the heart rates during uphill or downhill walk were recorded by EKG radio-telemetry. In the laboratory, oxygen consumption was obtained by the recorded heart rates, using individual heart rate vs oxygen consumption diagram obtained by treadmill test. the following results were obtained. 1. Uphill walk time was 36.5 minutes, and during this period the mean heart rate was 149.0 heats/min and peak heart rate was 169.2 beats/min. The total heart beats during the uphill walk was 5.433 beats. 2. The ratio of individual mean heart rate during the uphill walk to the maximal heart rate distributed between 66.6% and 98.3%, and the mean of the total group was 83.1%. The ratio of peak heart rate of uphill walk to the maximal heart rate was 94.5% in the group. Thus uphill walk of a 20% grade mountain course was an exhaustive exercise. 3. Oxygen consumption during uphill walk was 2.22 l/min (ranged between 1.79 and 2.70 l/min) and the ratio of this to the resting oxygen consumption was 8.31. The peak value of oxygen consumption during uphill walk was 2.73 l/min and the ratio of this to the resting oxygen consumption was 10.39. 4. Energy expenditure during uphill walk showed a mean of 11.1 kcal/min and the peak expenditure rate was 13.6 kcal/min. The total energy expenditure during 36.5 minutes of uphill walk was 396 kcal. 5. In downhill walk, the time was 31.7 minutes, mean heart rate was 118.4 (ranged between 100.1 and 142.7) beats/min, and the peak heart rate was only 129.4 beats/min. The ratio of mean heart rate to the maximal heart rate was 66.3%. Total heart beats during downhill walk was 3,710 beats. The ratio of downhill oxygen consumption to the resting consumption was 5.70. The rate of energy expenditure was 7.5 kcal/min, and the total onery expenditure during the 31.7 minutes of downhill walk was 228 kcal. 6. The effect of training was manifest in the uphill walk and not in the downhill walk. After training in mountain course walk, i) the uphill time was shortened, ii) mean heart rate increased, iii) time vs heart rate curve became smooth and showed less frequent zig-zag, i.e., the depth of trough on the curve decreased and the magnitude was less than 10 beats. In non-trained subject the depth of trough on the curve was greater than 50 beats and appeared more frequently. 7. Mountain climbing is a good health promotion exercise. For the promotion of health the reasonable amount of uphill mountain walk exercise in a 20% grade course is a walk for 40 or 50 minutes duration once a week.

  • PDF

TMC (Tracker Motion Controller) Using Sensors and GPS Implementation and Performance Analysis (센서와 GPS를 이용한 TMC의 구현 및 성능 분석)

  • Ko, Jae-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.828-834
    • /
    • 2013
  • In this paper, TMC (Tracker Motion Controller) as one of the many research methods for condensing efficiency improvements can be condensed into efficient solar system configuration to improve the power generation efficiency of the castle with Concentrated solar silicon and photovoltaic systems (CPV)experiments using PV systems. Microprocessor used on the solar system, tracing the development of solar altitude and latitude of each is calculated in real time. Also accept the value from the sensor, motor control and communication with the central control system by calculating the value of the current position of the sun, there is a growing burden on the applicability. Through the way the program is appropriate for solar power systems and sensors hybrid-type algorithm was implemented in the ARM core with built-in TMC, Concentrated CPV system compared to the existing PV systems, through the implementation of the TMC in the country's power generation efficiency compared and analyzed. Sensor method using existing experimental results Concentrated solar power systems to communicate the value of GPS location tracking method hybrid solar horizons in the coordinate system of the sun's azimuth and elevation angles calculated by the program in the calculations of astronomy through experimental resultslook clear day at high solar irradiation were shown to have a large difference. Stopped after a certain period of time, the sun appears in the blind spot of the sensor, the sensor error that can occur from climate change, however, do not have a cloudy and clear day solar radiation sensor does not keep track of the position of the sun, rather than the sensor of excellence could be found. It is expected that research is constantly needed for the system with ongoing research for development of solar cell efficiency increases to reduce the production cost of power generation, high efficiency condensing type according to the change of climate with the optimal development of the ability TMC.

Foliar Characteristics and Photosynthetic Efficiency of Three Species of Schisandraceae Trees Distributed in Korea (우리나라에 분포하는 오미자과 2속 3종의 잎 형질 및 광합성 특성)

  • Kim Pan-Gi;Lee Kab-Yeon;Kim Sea-Hyun;Han Sang-Sup
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.1 no.2
    • /
    • pp.90-96
    • /
    • 1999
  • Foliar and physiological characteristics of Schisandraceae plants distributed in Korea were investigated to elucidate differences in growth and the variations of inter and intra species of the plants. For this study, three species of Schisandraceae plants were used; i) Schisandra chinensis, decidious broad-leaved tree, ii) S. nigra, decidious broad-leaved tree, including monoecious, male and female types, ii) Kadsura japonica, evergreen broad-leaved tree. There were no significant differences in leaf length and width among three species, but leaves of Schisandra sp. plants were shorter and wider relative to those of K. japonica. The length of petiole of Schisandra sp. plants was greater than that of K. japonica and the difference was evident between female type of S. chinensis and K. japonica as longer as two times. Schisandra sp. trees showed larger size of stomata, but fewer numbers of stomata, compared with K. japonica. Although substantial changes in leaf morphology were not found in the Schisandraceae plants grown in different environmental conditions, the foliar length of K. japonica was seemed to be increased with increasing an altitude. Chlorophyll contents were also variable in inter and intra species and in, general K. japonica showed higher levels of chlorophyll contents relative to Schisandra sp. plants. K. japonica also showed higher light compensation point(LCP), light saturation point(LSP) and $CO_2$ assimilation rates at LSP, compared with Schisandra sp. trees. However, Schisandra sp. trees showed lower respiration per photosynthesis rates at LSP. The finding suggested that Schisandra sp. trees were acclimated to the growth conditions of lower light intensity with more effective photosynthetic activity. This was also confirmed by the fact that Schisandra sp. plants grown in shading places of a forest demonstrated the elevated rates of net $CO_2$ assimilation under the conditions of low light intensity.

  • PDF

Combined 1D/2D Inundation Simulation of Riverside Farmland using HEC-RAS (HEC-RAS를 이용한 하천변 농경지의 1, 2차원 연계 침수 모의)

  • Jun, Sang Min;Song, Jung-Hun;Choi, Soon-Kun;Lee, Kyung-Do;Kang, Moon Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.5
    • /
    • pp.135-147
    • /
    • 2018
  • The objective of this study was to analyze the characteristics of combined 1D/2D inundation simulation of riverside farmland using the Hydrologic Engineering Center - River Analysis System (HEC-RAS). We compared and analyzed inundation simulation results between 1D and combined 1D/2D hydraulic simulation using HEC-RAS. Calibration and validation of stream stage were performed using three rainfall events. The coefficient of determination ($R^2$) and root mean square error (RMSE) between simulated and observed stream stage were 0.935 - 0.957 and 0.250 m - 0.283 m in calibration and validation, respectively. The inundation area showed no significant difference in 1D and combined 1D/2D simulation ($8.48km^2$ in 1D simulation, $8.75km^2$ in combined 1D/2D simulation). The average inundation depth by 1D simulation was 1.4 m deeper than combined 1D/2D simulation. In the lower inundation depth, the inundation area by combined 1D/2D simulation was larger than inundation area by 1D simulation. As the inundation depth increased, the inundation area by 1D simulation became wider. In the case of the 1D/2D combined simulation, low elevation areas along the river bank were inundated widely. Compared to 1D/2D combined simulation, the flood radius in some sections was longer in 1D simulation. In the 1D analysis, because the low altitude riverside farmlands are also assumed to stream, it is calculated that riverside farmlands have the same stage as the mainstream when the stream is overflowed. Therefore, the inundation area seems to be overestimated in those sections. In other regions, the inundation areas tend to be broken depending on overflow by each stream cross-section. In the case of river flooding, the overflow is expected to flow to the lower area depending on the terrain, such as the results of the combined 1D/2D simulation. It is concluded that the results of combined 1D/2D inundation simulation reflected the topographical characteristics of low-lying farmland.

Interference of Sulphur Dioxide on Balloon-borne Electrochemical Concentration Cell Ozone Sensors over the Mexico City Metropolitan Area

  • Kanda, Isao;Basaldud, Roberto;Horikoshi, Nobuji;Okazaki, Yukiyo;Benitez-Garcia, Sandy-Edith;Ortinez, Abraham;Benitez, Victor Ramos;Cardenas, Beatriz;Wakamatsu, Shinji
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.3
    • /
    • pp.162-174
    • /
    • 2014
  • An abnormal decrease in ozonesonde sensor signal occurred during air-pollution study campaigns in November 2011 and March 2012 in Mexico City Metropolitan Area (MCMA). Sharp drops in sensor signal around 5 km above sea level and above were observed in November 2011, and a reduction of signal over a broad range of altitude was observed in the convective boundary layer in March 2012. Circumstantial evidence indicated that $SO_2$ gas interfered with the electrochemical concentration cell (ECC) ozone sensors in the ozonesonde and that this interference was the cause of the reduced sensor signal output. The sharp drops in November 2011 were attributed to the $SO_2$ plume from Popocat$\acute{e}$petl volcano southeast of MCMA. Experiments on the response of the ECC sensor to representative atmospheric trace gases showed that only $SO_2$ could cause the observed abrupt drops in sensor signal. The vertical profile of the plume reproduced by a Lagrangian particle diffusion simulation supported this finding. A near-ground reduction in the sensor signal in March 2012 was attributed to an $SO_2$ plume from the Tula industrial complex north-west of MCMA. Before and at the time of ozonesonde launch, intermittent high $SO_2$ concentrations were recorded at ground-level monitoring stations north of MCMA. The difference between the $O_3$ concentration measured by the ozonesonde and that recorded by a UV-based $O_3$ monitor was consistent with the $SO_2$ concentration recorded by a UV-based monitor on the ground. The vertical profiles of the plumes estimated by Lagrangian particle diffusion simulation agreed fairly well with the observed profile. Statistical analysis of the wind field in MCMA revealed that the effect Popocat$\acute{e}$petl was most likely to have occurred from June to October, whereas the effect of the industries north of MCMA, including the Tula complex, was predicted to occur throughout the year.

An Empirical Study on the Thermal Performance and Dynamic Behavior of Wall Integrated Thermosiphon Solar Water Heater (벽체일체형 자연순환 태양열온수기의 동적거동과 열성능에 관한 실증연구)

  • Baek, Nam-Choon;Kim, Sung-Bum;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.25-35
    • /
    • 2016
  • In this study, the evaluation of the dynamic behavior and thermal performance of the "Façade integrated Natural circulation Solar Water Heating System" installed in the residential house was carried out. Experimental tests were performed during the all year around in the rural houses of $166m^2$ in size. Facade integrated solar collector of $5m^2$ were installed on the south-facing. Electrical heater of 1 kW capacity as an auxiliary heater was installed at the upper part of the heat storage tank. The analyzing results are as follows. (1) Monthly average solar fraction was 51 to 87% and yearly average value is 64%. (2) Hot water supply temperature in December which has the lowest solar altitude is 37 to $76^{\circ}C$. The highest working fluid temperature of solar collector in this period was below $84^{\circ}C$. The temperature difference of working fluid between the collector inlet and outlet has been shown to be around 9 to $26^{\circ}C$. (3) Overheating which is one of the biggest problems during summer did not appear at all, but rather had hot water supply temperature is rather low as $30{\sim}47^{\circ}C$ in summer than winter, which is supplied by a small solar load. The solar collecting temperature has been shown to maintain below $55^{\circ}C$. (5) The thermal performance of Facade integrated solar collector can be increase due to the reduction of heat loss to the back of the collector wall integration of the collector is reduced. As a conclusion, Facade integrated natural circulation type Solar Water Heating System is a well-functioning without any pumps or controllers, and it was found that the disadvantages of conventional solar water heaters, hot water or hot water system can be greatly improved.

The approach of properties-flavours theory and the study of morphological standard in ARTEMISIAE HERBA (인진호(茵陳蒿)의 기미론(氣味論)적 해석과 내외부형태연구)

  • Lee, Hwa-Jung;Choi, Mun-Il;Kim, Ja-Young;Kang, Kyoung-Sik;Shin, Chol-Gyun;Jul, Young-Sung;Yun, Ju-Bong
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.19 no.2
    • /
    • pp.130-145
    • /
    • 2006
  • Objectives : The aim of this work is the approaching of properties-flavours theory and the making of morphological standard in Artemisiae herba. Methods : The properties-flavours theory were attempted with bibliographic method and various climate-information. The external-internal morphological standards were determined by using stereoscope and butanol series. Conclusions : The following is a list the conclusion of the approaching of properties-flavours theory and how to make the standard of morphological standard in artemisiae herba. 1. The significant analysis for the artemisiae herba as the properties-flavours theory, is a follow-up survey of the effect written in the official oriental medicine book 2. The other analytic methods according to the gathering time, processing or storing system or especially nature or growth environment(altitude, temperature,. the mean moisture, and the agronomical survey) by way of the explanation of properties-flavours theory appears so many insufficiency at the many cases. 3. In the case of artemisiae herba., there are 2 cases(Artemisia capillaris $T_{HUNB}$ and A. iwayomogi $K_{ITAMURA}$) in current and recently A. aruwa L. is substituted for artemisiae herba in circulation. 4. The external and internal characteristics according to the shape of original plant or herbal states, entirely correspond to all the official oriental medicine boo 5. According to the place of productiot the difference appeals. (1) A. capillatis $T_{HUNB}$. has leaves like a fine thread, and A. iwayomogi $K_{ITAMURA}$ has big and wide leaves, and shows some reddish color, and A. aruwa L. has narrow leaves, its section lines long vertically. (2) In the internal shapes, as the A. capillatis $T_{HUNB}$. leaves', upper epidermal cell wall shows relatively straight form, its all upper- lower epidemical cell wall has a stoma, and calcium rosette crystal is relatively few. As iwayomogi $K_{ITAMURA}$, all upper- lower epidermal cell wall is wavelike concave, and hypodermics has many stoma and many calcium rosette crystal. (3) In the internal shapes of A. aruwa L. the shape of leaves' epidermal cell is irregular and has so many non-glandular hair nad glandular hair on its surface.

  • PDF

Comparative Study on the Storage Experiment of Cheorwon Onion (철원양파의 저장실험 연구)

  • Kim, D.H.;Kim, Y.B.;Koo, H.J.;Leeo, H.J.;Kang, C.S.;Baek, H.J.;Lee, J.S.;Chang, K.J.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.21 no.2
    • /
    • pp.27-33
    • /
    • 2019
  • The purpose of this study was to compare the storage and post-storage changes of Cheorwon onions and onions for each region. Onion is a perennial plant belonging to the lily family. It is native to Persia of Southwest Asia. It is cultivated much in the temperate regions of the world. Cheorwon area is inland, but it has high continental climate due to its high altitude. Therefore it is said that the onion cultivated in this region has higher sugar content and higher taste than onion grown in southern region. Although the results of onion storage experiments in Cheorwon, Muan, Buan, and Changnyeong regions did not show much difference in weight, width, and height measurements before and after storage, Brix was reduced by approximately 1-2 brix. Before and after storing in each region, Brix was the highest in Cheorwon, Changnyeong, Buan, and Muan, and after saving, onions in Cheorwon were the same order. After each region was stored, the results showed that Cheorwon (112.3g), Muan (106g), Buan (102.1g) and Changnyeong (92.6g) had the highest hardness. Cold storage tests show that onions contain the least amount of corruption in paper boxes, while Cheorwon onions have the lowest level of corruption in other areas.

Prediction of Succession and Silvicultural Control in the Black Locust(Robinia pseudoacacia L.) Plantation (아까시나무(Robinia pseudoacacia L.) 조림지(造林地)에서 천이(遷移)의 예측(豫測)과 조림학적(造林學的) 제어(制御))

  • Yun, Chung Weon;Oh, Seung Hwan;Lee, Joon Hyouk;Joo, Sung Hyun;Hong, Sung Cheon
    • Journal of Korean Society of Forest Science
    • /
    • v.88 no.2
    • /
    • pp.229-239
    • /
    • 1999
  • To get ecological information necessary for the prediction on succession and the silvicultural control of the black locust(R. pseudoacacia) plantation, classification of vegetation unit. competition of major species, and succession were analyzed. The results were as follows. Vegetation units classified in R. pseudoacacia forest were Quercus variabilis community, Persicaria perfoliata community, Styrax japonica community, Acalypha australis community, Typical community. Species diversity indices showed significant difference among the vegetation units. As a result of stand ordination by CCA method, arrangement of stands on Axis I was correlated significantly with altitude, sand, silt and available phosphorus contents, and that on Axis II was with total nitrogen, exchangeable calcium and kalium contents. It was judged that R. pseudoacacia plantation would be replaced by the mixed forest including Quercus spp., Acer spp., and Prunus spp. etc., native to Korea with the progression of succession as the results of analyses on competition of major species and successional tendency in R. pseudoacacia plantation.

  • PDF