• Title/Summary/Keyword: DC Discharge

Search Result 375, Processing Time 0.033 seconds

Optimization on the Characteristics of DC Discharge Cell in the AND Gate PDPs (ADN Gate PDP의 DC 방전셀 방전특성 최적화)

  • Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.34-39
    • /
    • 2004
  • This research investigated the influence on the 4 cell of DC discharge on the side of the discharge characteristic. This DC discharge cells are that composes AND gate of AND gate PDP newly proposed. As for the discharge starting voltage of this discharge cell of 4 pieces, it has been understood that there is deeply a relation up to the space charge generated from the discharge of adjoining discharge cell through the experiment. The discharge voltages which had become each discharge cell optimizations from the experiment result were decided. Moreover, the width of the margin of two AND input voltages is wide and the AND function occurs clearly. However, it has been qualitatively understood that it is difficult enough to obtain the operation margin of the DC priming discharge used to address discharge of PDP.

Flow Actuation by DC Surface Discharge Plasma Actuator in Different Discharge Modes

  • Kim, Yeon-Sung;Shin, Jichul
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.16 no.3
    • /
    • pp.339-346
    • /
    • 2015
  • Aerodynamic flow control phenomena were investigated with a low-current DC surface discharge plasma actuator. The plasma actuator was found to operate in three different discharge modes with similar discharge currents of about 1 mA or less. Stable continuous DC discharge without audible noise was obtained at higher ballast resistances and lower discharge currents. However, even with continuous DC power input, a low-frequency self-pulsed discharge was obtained at lower ballast resistances, and a high-frequency self-pulsed discharge was obtained at higher set-point currents and higher ballast resistances, both with audible noise. The Schlieren image reveals that the low-frequency self-pulsed mode produces a synthetic jet-like flow implying that a gas heating effect plays a role, even though the discharge current is small. The high-frequency self-pulsed mode produces pulsed jets in a tangent direction, and the continuous DC mode produces a steady straight pressure wave. Particle image velocimetry (PIV) images reveal that the induced flow field by the low-frequency self-pulsed mode has flow propagating in the radial direction and centered between the electrodes. The high-frequency self-pulsed mode and continuous DC mode produce flow from the anode to the cathode. The perturbed region downstream of the cathode is larger in the high-frequency self-pulsed mode with similar maximum speeds.

A Study on the Characteristics of Floating Discharge in the AND Gate PDP (AND Gate PDP의 Floating 방전특성에 관한 연구)

  • 염정덕
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.22-27
    • /
    • 2004
  • The gas discharge AND gate which have been newly proposed is applied to three electrode surface discharge AC PDP. The address discharge characteristics by the DC-AC floating discharge by which Y electrode is made floating electrode is analyzed The address discharge can be begun by using the floating discharge from the experiment result Moreover, the display discharge can be sustained. The DC priming discharge that the floating discharge is matched to timing is generated in a supplementary electrode. As a result, space charge is supplied enough to the space of the floating discharge and the data voltage is lowered up to l00(V). Driving method to use this DC-AC floating discharge is able to obtain the address operation margin of l00(V).

DC Power Supply Driving Discharge Lamp Using PWM DC-DC Converter of Single- Phase Shift Soft Switching (위상 천이 소프트 스위칭 PWM DC-DC 컨버터를 이용한 방전등 구동용 직류 전원장치)

  • Lee, Hyun-Woo;Jung, Sang-Hwa;Kwon, Soon-Kurl;Suh, Ki-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.100-106
    • /
    • 2005
  • Generally, high frequency switching DC-DC converter that DC power supply for discharge lamp drive to generate ultraviolet rays(UV) is acted by hard switching mode is used. Therefore in this paper, wish to mix first existent first-side status phase shift PWM DC-DC converter and posing secondary-side status phase shift PWM DC-DC converter by high frequency link DC-DC converter that use soft switching circuit technology and develop DC power supply for discharge lamp drive. DC power supply driving Discharge lamp proposed describe validity through simulation and an experiment.

The Delay-Time Characteristics of DC Discharge in the Discharge Logic Gate Plasma Display Panel (방전논리게이트 플라즈마 디스플레이 패널의 직류방전 지연특성)

  • Ryeom, Jeong-Duk;Kwak, Hee-Ro
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.28-34
    • /
    • 2007
  • In this research, the characteristics of the DC discharge that was the logical gate input of discharge logic gate PDP newly proposed was considered. The logical output is induced by controlling the potential difference of inter-electrode according to the discharge path in the discharge logic gate. From the experimental result the discharge time lag was shortened to 1/3 and the voltage has decreased to 1/2 in the case to apply priming discharge for improving stability of these DC discharges compared with the case when it is not applied. Moreover, after the priming discharge ends, the space charge generated by this discharge influences it up to about $30[{\mu}s]$. And, as a measured result of the influence that the space charge exerts on the DC discharge with the change in time and spatial distance, it has been understood that there is a possibility that going away spatially can slip out the influence of the discharge easily as for going away from the discharge time-wise. Therefore the conclusion that the discharge logic gates of each scanning electrode can be operated independently is obtained.

Battery Discharge System Configuration using Photovoltaic Simulator and PCS (태양광 시뮬레이터와 PCS를 이용한 배터리 방전시스템 구성)

  • Jeong, Da-Woom;Park, Sung-Min;Park, Seong-Mi;Park, Sung-Jun;Moon, Seung-Pil
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.3
    • /
    • pp.491-498
    • /
    • 2020
  • Recently, In the production line of batteries, charge and discharge tests are essential to verify battery characteristics. In this case, the battery charging uses a unidirectional AC/DC converter capable of output voltage and current control, and the discharge uses a resistive load. Since this method consumes energy during discharge, it must be replaced with a bi-directional AC/DC converter system capable of charging and discharging. Although it is difficult to replace the connected inverter part of the bi-directional AC/DC converter system due to the high cost, the spread of the solar-connected inverter rapidly increases as the current solar supply business is activated, and thereby the solar-connected type Inverter prices are plunging. If it can be used as a power converter for battery discharge without program modification of the solar-powered inverter, it will have competition. In this paper, propose a new battery discharge system using a combination of a photovoltaic DC/DC simulator and photovoltaic PCS using a battery to be used as a power converter for battery discharge without program modification of a low-cost photovoltaic inverter. In addition, propose an optimal solar characteristic curve for the stable operation of PCS. The validity of the proposed system was verified using a 500[W] class solar DC/DC simulator and a solar PCS prototype.

A study on the RE/DC discharge cleaning for high vacuum SUS chamber (RF/DC 방전을 이용한 고 진공용SUS 용기세정에 관한 연구)

  • 김정형;임종연;서인용;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.3
    • /
    • pp.298-302
    • /
    • 2001
  • Cleaning effect of RF/DC discharge to clean the surface of vacuum chamber was studied for various discharge conditions. Glow discharge cleaning without baking reduced the outgassing rate to 1/2, which was similar to that after the only baking treatment alone. Glow discharge cleaning treatment with baking improved the cleaning efficiency and then the outgassing rate was remarkably reduced to 1/20. It was found that the ion energy and the ion density were important factors in cleaning the surface. RF discharge cleaning was more effective than BC discharge cleaning.

  • PDF

Partial Discharge Process and Characteristics of Oil-Paper Insulation under Pulsating DC Voltage

  • Bao, Lianwei;Li, Jian;Zhang, Jing;Jiang, Tianyan;Li, Xudong
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.436-444
    • /
    • 2016
  • Oil-paper insulation of valve-side windings in converter transformers withstand electrical stresses combining with AC, DC and strong harmonic components. This paper presents the physical mechanisms and experimental researches on partial discharge (PD) of oil-paper insulation at pulsating DC voltage. Theoretical analysis showed that the phase-resolved distributions of PDs generated from different insulated models varied as the increase of the applied voltages following a certain rule. Four artificial insulation defect models were designed to generate PD signals at pulsating DC voltages. Theoretical statements and experimental results show that the PD pulses first appear at the maximum value of the applied pulsating DC voltage, and the resolved PD phase distribution became wider as the applied voltage increased. The PD phase-resolved distributions generated from the different discharge models are also different in the phase-resolved distributions and development progress. It implies that the theoretical analysis is suitable for interpretation of PD at pulsating DC voltage.

The Comparison of Adhesion Properties on Polyester Fabric by AC and DC Corona Treatment (AC와 DC 코로나 처리에 따른 폴리에스테르 직물의 접착성질 비교)

  • Lee, Jae Ho
    • Journal of Adhesion and Interface
    • /
    • v.17 no.3
    • /
    • pp.104-109
    • /
    • 2016
  • Compare AC corona and DC corona treatment effects, polyester fabrics were AC corona treated with different current intensity (5, 10, 15 A) and feeding speed (5, 10, 15 m/min) as the same DC corona treatment conditions of the preceding research. We confirmed the surface change of polyester fabrics using scanning electron microscopy (SEM) and X-ray photoelectron spectrometer (XPS), and the change of physical properties through measuring the dry and wet bonding strength. The surface changes of polyester fabrics by treating in air atmosphere with AC corona discharge are shown similar tendency with DC corona discharge. Generally dry bonding strength were increased with increasing current intensity and feeding speed, but wet bonding strength were increased with increasing current intensity and decreasing feeding speed in both AC and DC corona treatment. When the current is 20 A, carbonization occurs in DC corona discharge but carbonization does not occur in DC corona discharge.

A Study on Energy Efficiency of Battery Charge/Discharge System based on DC μ-Grid (DC μ-Grid 기반 배터리 충/방전 시스템의 에너지 효율에 관한 연구)

  • Yeo, Sung-Dae;Kim, Jong-Un;Lee, Kyung-Ryang;Han, Cheol-Kyu;Ryu, Tae-Hyoung;Kim, Kyeong-Hwa;Kim, Seong-Kweon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.12
    • /
    • pp.1337-1344
    • /
    • 2015
  • Formation process through charge/discharge operation is needed in manufacturing Li-ion battery. In the process battery is discharged by a load resistor of discharger. Here, energy losses happen. Therefore, in this paper, the efficient energy operation of battery is studied in the charge/discharge system based on DC ${\mu}-Grid$. A result of computer simulation shows that if in the charge/discharge system based on DC ${\mu}-Grid$, the number of discharge batteries in comparison with three charge battery sets exceeds 133%, voltage fluctuation that occurs while the grid voltage stabilizes, which makes the system fatal. Therefore, it was demonstrated that a remarkable energy saving effect could be achieved when the number of discharge battery set is maintained to be 133% in comparison with three charge battery sets.