• Title/Summary/Keyword: D/tc

Search Result 741, Processing Time 0.047 seconds

Assessment of Regional Myocardial Wall Motion by Gated $^{99m}Tc-MIBI$ Myocardial SPECT (게이트 $^{99m}Tc-MIBI$ 심근 SPECT의 심근 분절 운동 평가능력)

  • Kim, S.W.;Lee, D.S.;Kim, S.H.;Hyun, I.Y.;Chung, J.K.;Lee, M.M.;Lee, M.C.;Koh, C.S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.473-477
    • /
    • 1995
  • Information about regional wall motion obtained with gated $^{99m}Tc-MIBI$ SPECT was compared in 23 subjects(4 normals) to echocardiography or contrast left ventriculography. Gated SPECT study using 20-30 mCi $^{99m}Tc-MIBI$ were aquired lot 8 frames/RR interval (aqusition time=40min.) and processed with Cine Mode computer protocol. Regional wall motion was assessed by visual analysis. The concordance with echocardiography was 88% and with contrast ventriculography was 78%. We conclude that gated $^{99m}Tc-MIBI$ SPECT was effective in assessing the regional wall motion with the information of regional perfusion in one study.

  • PDF

Location Error Analysis of an Active RFID-Based RTLS in Multipath and AWGN Environments

  • Myong, Seung-Il;Mo, Sang-Hyun;Yang, Hoe-Sung;Cha, Jong-Sub;Lee, Heyung-Sub;Seo, Dong-Sun
    • ETRI Journal
    • /
    • v.33 no.4
    • /
    • pp.528-536
    • /
    • 2011
  • In this paper, we analyze the location accuracy of real-time locating systems (RTLSs) in multipath environments in which the RTLSs comply with the ISO/IEC 24730-2 international standard. To analyze the location error of RTLS in multipath environments, we consider a direct path and indirect path, in which time and phase are delayed, and also white Gaussian noise is added. The location error depends strongly on both the noise level and phase difference under a low signal-to-noise ratio (SNR) regime, but only on the noise level under a high SNR regime. The phase difference effect can be minimized by matching it to the time delay difference at a ratio of 180 degrees per 1 chip time delay (Tc). At a relatively high SNR of 10 dB, a location error of less than 3 m is expected at any phase and time delay value of an indirect signal. At a low SNR regime, the location error range increases to 8.1 m at a 0.5 Tc, and to 7.3 m at a 1.5 Tc. However, if the correlation energy is accumulated for an 8-bit period, the location error can be reduced to 3.9 m and 2.5 m, respectively.

Effects of stress after road transportation and oral administration of chromium and meloxicam on plasma cortisol concentrations and behavior in dairy calves

  • Jung, Da Jin Sol;Lee, Jaesung;Kim, Do Hyun;Beak, Seok-Hyeon;Hong, Soo Jong;Jeong, In Hyuk;Yoo, Seon Pil;Lee, Jin Oh;Cho, In Gu;Fassah, Dilla Mareistia;Kim, Hyun Jin;Baik, Myunggi
    • Animal Bioscience
    • /
    • v.35 no.3
    • /
    • pp.503-510
    • /
    • 2022
  • Objective: This study was performed to determine the effects of stress after road transportation and oral administration of chromium and meloxicam on growth performance, plasma cortisol, serum metabolites, and behavior in dairy calves. Methods: A total of 50 Holstein heifers (average body weight [BW]: 172±4.19 kg; average age: 5.53±0.12 months) were randomly assigned to five groups including NL (not transported + D-lactose; 1 mg/kg BW), TL (transported + D-lactose; 1 mg/kg BW), TC (transported + chromium; 0.5 mg/kg dry matter [DM] feed), TM (transported + meloxicam; 1 mg/kg BW), and TMC (transported + combination of meloxicam and chromium; 1 mg/kg BW and 0.5 mg/kg DM, respectively). Doses of D-lactose monohydrate, meloxicam, and chromium were prepared for oral administration by suspension in 15 mL of water in a 20-mL dosing syringe. Blood was collected before transportation, immediately after 120 km of transportation (IAT), and at 6, 24, and 48 h after transportation. Results: Neither transportation nor administration of meloxicam and/or chromium affected (p = 0.99) average daily gain and feed intake. Plasma cortisol concentrations in the NL group (average 0.13 and 0.18 nmol/L, respectively) were lower (p<0.001) compared to the TL group (average 0.39 and 0.61 nmol/L, respectively) at IAT and 48 h after transportation. At 48 h after transportation, cortisol concentrations were lower (p<0.05) in the TC group (average 0.22 nmol/L) than in the TL group (average 0.61 nmol/L), and TC calves had similar cortisol concentrations to NL calves. Lying duration (min/d) was shorter (p<0.05) in the TL group than in the NL group at 2 d after transportation. Lying duration was longer (p<0.05) for the TC and TMC groups than for the TL group at 2 d after transportation. Conclusion: Transportation increased cortisol concentrations and affected lying behavior, while chromium administration reduced cortisol concentrations and changed lying behavior. Thus, chromium administration before transportation may be a viable strategy to alleviate stress elicited by road transportation.

Usability of Multiple Confocal SPECT SYSTEM in the Myocardial Perfusion SPECT Using $^{99m}Tc$ ($^{99m}Tc$을 이용한 심근 관류 SPECT에서 Multiple Confocal SPECT System의 유용성)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.65-71
    • /
    • 2011
  • Purpose: The recently adopted multiple confocal SPECT SYSTEM (hereinafter called IQ SPECT$^{TM}$) has a high difference from the conventional myocardial perfusion SPECT in the collimator form, image capture method, and image reconstruction method. This study was conducted to compare this novice equipment with the conventional one to design a protocol meeting the IQ SPECT, and also determine the characteristics and usefulness of IQ SPECT. Materials and Methods: 1. For the objects of LEHR (Low energy high resolution) collimator and Multiple confocal collimator, $^{99m}Tc$ 37MBq was put in the acrylic dish then each sensitivity ($cpm/{\mu}Ci$) was measured at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. 2. Based on the sensitivity measure results, IQ SPECT Protocol was designed according to the conventional general myocardial SPECT, then respectively 278 kBq/mL, 7.4 kBq/mL, and 48 kBq/mL of $^{99m}Tc$ were injected into the myocardial and soft tissues and liver site by using the anthropomorphic torso phantom then the myocardial perfusion SPECT was run. 3. For the comparison of FWHMs (Full Width at Half Maximum) resulted from the image reconstruction of LEHR collimator, the FWHMs (mm) were measured with only algorithms changed, in the case of the FBP (Filtered Back projection) method- a reconstruction method of conventional myocardial perfusion SPECT, and the 3D OSEM (Ordered subsets expectation maximization) method of IQ SPECT, by using $^{99m}Tc$ Line source. Results: 1. The values of IQ SPECT collimator sensitivity ($cpm/{\mu}Ci$) were 302, 382, 655, 816, 1178, and those of LEHR collimator were measured as 204, 204, 202, 201, 198, both at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. It was found the difference of sensitivity increases up to 4 times at the distance of 30 cm in the cases of IQ SPECT and LEHR. 2. The myocardial perfusion SPECT Protocol was designed according to the geometric characteristics of IQ SPECT based on the sensitivity results, then the phantom test for the aforesaid protocol was conducted. As a result, it was found the examination time can be reduced 1/4 compared to the past. 3. In the comparison of FWHMs according to the reconstructed algorithm in the FBP method and 3D OSEM method followed after the SEPCT test using a LEHR collimator, the result was obtained that FWHM rose around twice in the 3D OSEM method. Conclusion : The IQ SPECT uses the Multiple confocal collimator for the myocardial perfusion SPECT to enhance the sensitivity and also reduces examination time and contributes to improvement of visual screen quality through the myocardial-specific geometric image capture method and image reconstruction method. Due to such benefits, it is expected patients will receive more comfortable and more accurate examinations and it is considered a further study is required using additional clinical materials.

  • PDF

Correction Method of High-precision Signal for Aircraft Automatic Test Equipment Using Least Squares Method (최소자승법을 이용한 비행체 자동점검장비의 고정밀 신호 보정 방안)

  • Lee, Seong-woo;Kim, Dong-hyouk;Kim, Seong-woo;Seo, Min-gi;Lee, Cheol-hoon
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.2
    • /
    • pp.64-69
    • /
    • 2018
  • Automatic test equipment for field maintenance of aircraft mounted equipment is effective for integrated design when operating a small number of aircraft for special purposes. The integrated automatic test equipment identifies commonly used interfaces and is used for branching or generating routes for each unit under test specific inspection. High-precision signals such as RTD, TC, and analog voltage can cause measurement errors due to conduction resistance during signal branching and connection when generating branches and paths. The measurement error caused by the resistance of the wire leads to a lot of restrictions in designing the equipment to be inspected. In this paper, we propose a method of calibrating highly accurate signals of an integrated automatic inspection equipment that minimizes measurement errors of analog voltage and high - precision signals.

Phantom Study of the Mutual Influences Between 18F-FDG and 99mTcO4- on the Same Day (18F-FDG와 99mTcO4-를 이용한 당일 검사 시 상호 영향에 대한 Phantom 연구)

  • Ham, Jun Cheol;Park, Min Soo;Bahn, Young Kag;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.68-72
    • /
    • 2014
  • Purpose The nuclear medicine examination, there is a difficulty to carry out the inspection of both on the day of residual isotope due to the half-life. In this study, by studying the mutual influence and $^{18}F$-FDG of $^{99m}TcO_4{^-}$, I would like to explain the matters to be considered in the case of performing the same day. Materials and Methods With the NEMA-1994 Phantom, and experiments were performed 3 times. Create a 1: 4 Background ratio HOT and the $^{99m}TcO_4{^-}$ The first experiment: After underwent SPECT in INFINIA (GE Healthcare, MI, USA), and were injected with $^{18}F$-FDG 37 MBq in the Background area, 13 once for 60 minutes under the same conditions was time Scan. Create a 1: 4 Background ratio HOT and the $^{18}F$-FDG second is: The Scan in PET/CT Discovery 600 (GE Healthcare, MI, USA), and 148 MBq after injection $^{99m}TcO_4{^-}$ the Background area, once for 60 minutes, 6 under the same conditions was time Scan. Create a 1: 4 Background ratio HOT and the $^{18}F$-FDG experiments las, increments of 296 MBq and 148 MBq the 1 Bed Scan after $^{99m}TcO_4{^-}$, was 1 Bed Scan under the same conditions. Non BKG area and HOT, I was measured comparing the Total Counts and SNR or CNR. Results Showed a significant difference in the ratio CNR of enforcement during SPECT $^{18}F$-FDG is, (p>0.05). The $^{99m}TcO_4{^-}$ was no significant difference between the SNR ratio of PET / CT at the time of the effective date (p<0.05). I got the results $^{99m}TcO_4{^-}$ that reduce the Total Counts of PET / CT scan. Conclusion If you make a PET / CT scan, may affect the test using the $^{99m}TcO_4{^-}$ up to 12 hours, when it is performed before the $^{99m}TcO_4{^-}$, does not affect the SNR and SUV, PET / CT scan I reduced the detection efficiency. The inspection of day, we'd like to recommend a way to complement the detection efficiency to increase the inspection time of PET / CT in move forward the inspection using the $^{99m}TcO_4{^-}$.

  • PDF

Stress/Rest Tc-99m-MIBI SPECT in Comparison with Rest/Stress Rubidium-82 PET (휴식/부하 심근 Rubidium-82 양전자단층촬영과 부하/휴식 심근 Tc-99m-MIBI 단일광자단층촬영의 비교)

  • Lee, D.S.;Kang, K.W.;Lee, K.H.;Jeong, J.M.;Kwark, C.;Chung, J.K.;Lee, M.C.;Seo, J.D.;Koh, C.S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.31-40
    • /
    • 1995
  • We compared stress/rest myocardial Tc-99m-MIBl tomographic image findings with rest/stress rubidium-82 tomographic images. In 23 patients with coronary artery disease (12 of them received bypass grafts before) and 6 normal subjects, rest rubidium PET study was performed : rubidium-82 and Tc-99m-MIBI were injected simultaneously to each patient after dipyridamole stress for rubidium PET and MIBI SPECT; and rest MIBI SPECT was performed 4 hours thereafter. We scored segmental decrease of rubidium or MIBI uptakes into 5 grades for 29 segments from 3 short-axis, vertical and horizontal slices. Scores were summed for each major arterial territory. When more score than two grade-2's or one grade-3 was considered as the cue for significant stenosis for major arterial territories, 67% of 46 stenosed arteries were found with MIBI studies and 78% of them by rubidium studies. Fourteen among 28 grafted arterial territories of 12 post-CABG patients were found normal with both rubidium and MIBI. Segmental scores were concordant between rubidium and MIBI in 72% of 709 stress segments and in 80% of 825 rest segments. Stress rubidium segmental scores were less than stress MIBI scores in 9%, so were rest rubidium scores. Stress rubidium scores were more than stress MIBI scores in 20% of segments, and rest rubidium segmental scores were more than rest MIBl scores in 11%. Rank correlations (Spearman's rho's more than 0.7(stress) and 0.5(rest), slopes (MIBI/rubidium) around 0.7(stress) and 0.9 (rest)) suggested deeper and wider defects in stress with rubidium. Slope over 1 (MIBI/rubidium) with LAD segemental scores at rest and 7 territories which had much larger score with MIBI revealed exaggeration of rest defects with rest MIBI in same-day stress/rest study. Difference scores (stress-rest for each territory) suggesting Ischemia were larger with rubidium (slope of MIBI/rubidium around 0.45). As has been implied by animal or separate-day-human studies, these segmental analyses with simultaneous examination in patients told that rubidium PET flow studies disclose ischemia more often than MIBI studies and that rest MIBI studies in same-day stress/rest-sequence gave a little larger rest defect than they would have shown.

  • PDF