• Title/Summary/Keyword: Coupling Image

Search Result 85, Processing Time 0.022 seconds

Optimization of Slanted and Chirp IDT Configurations for Realizing and Propagating Surface Acoustic Wave with Wide Bandwidth (광대역 표면탄성파 구현을 위한 slanted 및 chirp IDT의 최적화)

  • Lee, Tae-Yoon;Fu, Chen;Lee, Kee-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1730-1736
    • /
    • 2013
  • Slanted and chirp interdigital transducer(IDT) configurations were studied for generating the surface acoustic wave(SAW) with wide bandwidths on a piezoelectric substrate. These devices can be applied to manipulate optical path of light along the waveguide, ultimately used for optical switches and holographic image implementation. Prior to fabrication, the coupling of modes(COM) modeling and simulation were performed to extract optimal design parameters. The optimally designed wideband device showed wide bandwidth of 30MHz, low insertion loss of -25dB, and abrupt side suppression ratio (SSR). Several design conditions were determined during device implementation, such as slanted angle, aperture length, number of fingers, and central frequencies of IDTs. These factors were experimentally analyzed and described in details in this paper.

Measurement of Effective Refractive Index of Anodic Aluminum Oxide Using a Prism Coupler

  • Gong, Su-Hyun;Cho, Y.H.;Stolz, Arnaud;Gokarna, Anisha;Dogheche, Elhadj;Ryu, Sang-Wan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.195-195
    • /
    • 2010
  • In recent years, Anodic aluminum oxide(AAO) has become popular and attractive materials. It can be easily fabricated and self-organized pore structures. It has been widely used as a biosensor membrane, photonic crystal for optical circuit and template for nanotube growth etc. In previous papers, the theory was developed that AAO shows anisotropic optical properties, since it has anisotropic structure with numerous cylindrical pores. It gives rise to the anisotropy of the refractive index called as birefringence. It can be used as conventional polarizing elements with high efficiency and low cost. Therefore, we would like to compare the theory and experimental results in this study. One method which can measure effective refractive index of thin film is the prism coupling technique. It can give accurate results fast and simply. Furthermore, we can also measure separately the refractive index with different polarization using polarization of the laser (TE mode and TM mode). We calculated the effective refractive index with effective medium approximations (EMAs) by pore size in the SEM image. EMAs are physical models that describe the macroscopic system as the homogeneous and typical method of all mean field theories.

  • PDF

Broad-Band Design of Lumped-Element 3dB Quadrature Hybrid (집중정수형 3dB90$^{\circ}$Hybrid의 광대역 설계에 관한 연구)

  • 김동일;정세모;김시화
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.10 no.6
    • /
    • pp.317-326
    • /
    • 1985
  • A broad-band design method of a lumped-element 3dB quadrature hybrid without magnetic coupling is proposed and discussed, where techniques of cascading fundamental hybrids via second-order delay equalizers and adding matching sections are adopted. It is shown that the designed broad-band lumped-element 3dB quadrature hybrid can be easily constructed and its bandwidth reaches up to 54%. Furthermore, the esperiments have been carried out, the results of which agree with the theoretical ones, and hence, the validity of the broad-band design method proposed here was confirmed.

  • PDF

A Study on the Reliability Evaluation of the Cross-well Seismic Travel-time Tomography (시추공 탄성파 주시 토모그래피의 신뢰도 평가에 관한 연구)

  • Lee, Doo-Sung
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.4
    • /
    • pp.330-335
    • /
    • 2010
  • In order to estimate the confidence level of the velocity distribution shown in a velocity image reconstructed from a travel-time tomography, the ray coverage and the inversion characteristics of the system matrix were investigated. The targets of the analysis is the first arrival travel-time, the raypath information, and the resulting velocity model. The ray coverage, degree of ray and model coupling, was estimated by the number of rays and total ray length in a velocity grid, and information regarding the resolution and uncertainties involved in the reconstructed velocity model was derived from the results of the SVD analysis of the system matrix that relates the data space (first arrival travel times) to the model space (velocity distribution in tomogram).

Air-coupled ultrasonic tomography of solids: 2 Application to concrete elements

  • Hall, Kerry S.;Popovics, John S.
    • Smart Structures and Systems
    • /
    • v.17 no.1
    • /
    • pp.31-43
    • /
    • 2016
  • Applications of ultrasonic tomography to concrete structures have been reported for many years. However, practical and effective application of this tool for nondestructive assessment of internal concrete condition is hampered by time consuming transducer coupling that limits the amount of ultrasonic data that can be collected. This research aims to deploy recent developments in air-coupled ultrasonic measurements of solids, described in Part 1 of this paper set, to concrete in order to image internal inclusions. Ultrasonic signals are collected from concrete samples using a fully air-coupled (contactless) test configuration. These air coupled data are compared to those collected using partial semi-contact and full-contact test configurations. Two samples are considered: a 150 mm diameter cylinder with an internal circular void and a prism with $300mm{\times}300mm$ square cross-section that contains internal damaged regions and embedded reinforcement. The heterogeneous nature of concrete material structure complicates the application and interpretation of ultrasonic measurements and imaging. Volumetric inclusions within the concrete specimens are identified in the constructed velocity tomograms, but wave scattering at internal interfaces of the concrete disrupts the images. This disruption reduces defect detection accuracy as compared with tomograms built up of data collected from homogeneous solid samples (PVC) that are described in Part 1 of this paper set. Semi-contact measurements provide some improvement in accuracy through higher signal-to-noise ratio while still allowing for reasonably rapid data collection.

The Design and Measurements of 100/150 GHz Band Single Side Band Filters by Using Rotated Polarization (편파 회전을 이용한 100/150 GHz 대역용 단측파대 여파기의 제작 및 성능측정)

  • Park, Jong-Ae;Han, Seog-Tae;Kim, Tai-Seong;Kim, Kwang-Dong;Kim, Hyo-Ryong;Chung, Hyun-Su;Cho, Se-Hyung;Yang, Jong-Man
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.2
    • /
    • pp.20-30
    • /
    • 1999
  • We have made the single side hand filter for the dual channel receiver which is a heterodyne receiver to observe the cosmic radio waves with 100GHz band ranged from 85GHz to 115GHz and 150GHz band ranged from 125GHz to 175GHz simultaneously. We have introduced the filter theory using the principle of the Martion-Puplett interferometer, which has the characteristics of rotated polarization. To reduce the loss of the transmission and beam coupling which are caused from the path difference associated with the intermediate frequency the design and the implementation have been intensely considered. The receiver needs two filters with different characteristics each other. Because each of them has the optimum positions as a function frequency at which the signal frequency is fed to mixer and the image frequency is rejected to the image termination load. The intermediate frequency and its band width have been also evaluated. We have measured the property of two filters using the vector network analyser and the beam measurement system which is made by us. The responses of the filter as a function of the position and the frequency are compared with the theory. It is shown that not only the measured values are very close to the theoretical values, but also the image rejection ratios are better than 22dB for both filters. Through successful observation using a dual channel receiver with two manufactured filters, the performance of the filters has finally verified.

  • PDF

An Evaluation Method of X-ray Imaging System Resolution for Non-Engineers (비공학도를 위한 X-ray 영상촬영 시스템 해상력 평가 방법)

  • Woo, Jung-Eun;Lee, Yong-Geum;Bae, Seok-Hwan;Kim, Yong-Gwon
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.309-314
    • /
    • 2012
  • Nowadays, digital Radiography (DR) systems are widely used in clinical sites and substitute the analog-film x-ray imaging systems. The resolution of DR images depends on several factors such as characteristic contrast and motion of the object, the focal spot size and the quality of x-ray beam, x-ray scattering, the performance of the DR detector (x-ray conversion efficiency, the intrinsic resolution). The DR detector is composed of an x-ray capturing element, a coupling element and a collecting element, which systematically affect the system resolution. Generally speaking, the resolution of a medical imaging system is the discrimination ability of anatomical structures. Modulation transfer function (MTF) is widely used for the quantification of the resolution performance for an imaging system. MTF is defined as the frequency response of the imaging system to the input of a point spread function and can be obtained by doing Fourier transform of a line spread function, which is extracted from a test image. In clinic, radiologic technologists, who are in charge of system maintenance and quality control, have to evaluate or make routine check on their imaging system. However, it is not an easy task for the radiologic technologists to measure MTF accurately due to lack of their engineering and mathematical backgrounds. The objective of this study is to develop and provide for radiologic technologists a medical system imaging evaluation tool, so that they can measure and quantify system performance easily.

The Construction of GIS-based Flood Risk Area Layer Considering River Bight (하천 만곡부를 고려한 GIS 기반 침수지역 레이어 구축)

  • Lee, Geun-Sang;Yu, Byeong-Hyeok;Park, Jin-Hyeog;Lee, Eul-Rae
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.12 no.1
    • /
    • pp.1-11
    • /
    • 2009
  • Rapid visualization of flood area of downstream according to the dam effluent in flood season is very important in dam management works. Overlay zone of river bight should be removed to represent flood area efficiently based on flood stage which was modeled in river channels. This study applied drainage enforcement algorithm to visualize flood area considering river bight by coupling Coordinate Operation System for Flood control In Multi-reservoir (COSFIM) and Flood Wave routing model (FLDWAV). The drainage enforcement algorithm is a kind of interpolation which gives to advantage into hydrological process studies by removing spurious sinks of terrain in automatic drainage algorithm. This study presented mapping technique of flood area layer considering river bight in Namgang-Dam downstream, and developed system based on Arcobject component to execute this process automatically. Automatic extraction system of flood area layer could save time-consuming efficiently in flood inundation visualization work which was propelled based on large volume data. Also, flood area layer by coupling with IKONOS satellite image presented real information in flood disaster works.

  • PDF

Performance Analysis of the Powerline Communication for Condition Monitoring System of an MW Class Offshore Wind Turbine's Nacelle (MW급 해상풍력발전기 나셀의 상태 감시를 위한 전력선 통신 성능 분석)

  • Sohn, Kyung-Rak;Kim, Kyoung-Hwa;Jeong, Seong-Uk;Nam, Seung-Yun;Kim, Hyun-Sik
    • Journal of Navigation and Port Research
    • /
    • v.40 no.3
    • /
    • pp.159-164
    • /
    • 2016
  • The goal of this study is to implement a communication system that can monitor the status of the nacelle using the power cable itself, without the dedicated communication lines such as an UTP cable and optical fiber for the offshore wind turbine. An inductive coupling powerline communication system for a MW class offshore wind turbine was proposed and its communication performance was demonstrated. The inductive couplers was designed for operation at up to 500 A using a ferrite composite materials. Field test was carried out on the wind farms of Jeju island. Using the iperf communication test program, we have obtained more than 15 Mbps data transmission rate through the 100 m power cable that was installed between the nacelle and the bottom of the power converter. In the data transmission stability test for a week, there was no failure ever. The minimum transmission rate was 15 Mbps and the average data rate was about 20 Mbps. Next, we have installed an infrared camera inside the nacelle in order to measure the temperature distribution and variation of the nacelle. The real-time thermal image taken by the camera was successfully sent to the monitoring system without error.

Surface Plasmon Resonance Imaging Analysis of Hexahistidine-tagged Protein on the Gold Thin Film Coated with a Calix Crown Derivative

  • Chung, Bong-Hyun;Baek, Seung-Hak;Shin, Yong-Beom;Kim, Min-Gon;Ro, Hyeon-Su;Kim, Eun-Ki
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.2
    • /
    • pp.143-146
    • /
    • 2004
  • A surface plasmon resonance (SPR) imaging system was constructed and used to detect the hexahistidine-ubiquitin-tagged human parathyroid hormone fragment (His$\sub$6/-Ub-hPTHF(1-34)) expressed in Escherichia coli. The hexahistidine-specific antibody was immobilized on a thin gold film coated with ProLinker$\^$TM/ B, a novel calixcrown derivative with a bifunctional coupling property that permits efficient immobilizaton of capture proteins on solid matrices. The soluble and insoluble fractions of an E. coli cell lysate were spotted onto the antibody-coated gold chip, which was then washed with buffer (pH 7.4) solution and dried. SPR imaging measurements were carried out to detect the expressed His$\sub$6/-Ub-hPTHF(1-34). There was no discernible protein image in the uninduced cell lysate, indicating that non-specific binding of contaminant proteins did not occur on the gold chip surface. It is expected that the approach used here to detect affinity-tagged recombinant proteins using an SPR imaging technique could be used as a powerful tool for the analyses of a number of proteins in a high-throughput mode.