• 제목/요약/키워드: Corrosion level

검색결과 346건 처리시간 0.022초

토양오염방지를 위한 지하저장탱크의 관리 방안 연구 (Management Criteria of Underground Strage Tank for Prevention of Soil Contamination)

  • 김준현;한영한
    • 산업기술연구
    • /
    • 제18권
    • /
    • pp.453-460
    • /
    • 1998
  • The purpose of this study was to analyze their status of underground storage tank(UST) facilities and level of soil contamination, and to establish its management criteria. DB program was developed to analyze the correlation between specific characteristic of UST and level of soil contamination. For a suitable management of UST, leakage monitoring and inspection method of UST was investigated. Inspection period was established based on the leakage rate. The most dominant factor for leakage seemed to be caused by the corrosion. Therefore, main factor, construction method and installation year of UST, and corrosion protection system were suggested for optimal protection of UST. Considering the present management status of UST in Korea, inspection and management criteria of UST should be accomplished in term of contamination protection of leakage, and flexible regulation act should be introduced for each specific site.

  • PDF

Estimation of Critical Chloride Threshold Value in Concrete by the Accelerated Corrosion Test

  • ;배수호;박재임;이광명;김지상;정상화
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.201-204
    • /
    • 2006
  • It should be noted that the critical chloride threshold level is not considered to be a unique value for all conditions. This value is dependent on concrete mix proportions, cement type and constituents, presence of admixtures, environmental factors, reinforcement surface conditions, and other factors. In this study, the accelerated corrosion test for reinforcing steel was conducted by electrochemical and cyclic wet and dry seawater method, respectively and during the test, corrosion monitoring by half-cell potential method was carried out to detect the time to initiation of corrosion for individual test specimen. For this purpose, lollypop and right hexahedron test specimens were made for 31%, 42%, and 50% of W/C, respectively, and then the accelerated corrosion test for reinforcing steel was executed. It was observed from the test that the time to initiation of corrosion was found to be different with the water-cement ratio and accelerated corrosion test method, respectively and the critical chloride threshold values were found to range from 0.91 to $1.47kg/m^3$.

  • PDF

Corrosion behaviors of SS316L, Ti-Gr.2, Alloy 22 and Cu in KURT groundwater solutions for geological deep disposal

  • Gha-Young Kim;Junhyuk Jang;Minsoo Lee;Mihye Kong;Seok Yoon
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4474-4480
    • /
    • 2022
  • Deep geological disposal using a multibarrier system is a promising solution for treating high-level radioactive (HLRW) waste. The HLRW canister represents the first barrier for the migration of radionuclides into the biosphere, therefore, the corrosion behavior of canister materials is of significance. In this study, the electrochemical behaviors of SS316L, Ti-Gr.2, Alloy 22, and Cu in naturally aerated KAERI underground research tunnel (KURT) groundwater solutions were examined. The corrosion potential, current, and impedance spectra of the test materials were recorded using electrochemical methods. According to polarization and impedance measurements, Cu exhibits relatively higher corrosion rates and a lower corrosion resistance ability than those exhibited by the other materials in the given groundwater condition. In the anodic dissolution tests, SS316L exposed to the groundwater solution exhibited the most uniform corrosion, as indicated by its surface roughness. This phenomenon could be attributed to the extremely low concentration of chloride ions in KURT groundwater.

철근부식에 의한 철근콘크리트골조의 구조성능분석 (Structural Performance Investigation for the Reinforced Concrete Frames Deteriorated by the Reinforcement Corrosion)

  • 최세운
    • 한국전산구조공학회논문집
    • /
    • 제28권5호
    • /
    • pp.563-570
    • /
    • 2015
  • 기존 구조물의 손상평가에 관한 연구는 지진 등과 같은 과도한 하중에 의한 손상을 고려하였다. 그러나 구조물은 과도한 하중없이도 장기간의 시간에 따라 염화물, 탄성화 등과 같은 이유로 노후화가 진행되어 구조성능이 저하될 수 있다. 그래서 구조물의 건전도를 효과적으로 관리하기 위해서는 노후화에 의한 구조성능 저하도 검토되어야 한다. 본 연구에서는 염화물에 의한 철근의 부식을 노후화 요인으로 고려한다. 철근부식에 의한 재료의 구조성능 저하를 고려하기 위해 부식정도에 따른 철근의 단면적, 항복강도, 파단변형률, 피복 콘크리트 강도 등을 예측한다. 이를 구조모델링에 적용하여 구조부재 및 구조물의 구조성능 저하를 분석한다. 구조부재의 구조성능을 분석하기 위해 모멘트-곡률 해석을 수행한다. 구조물 레벨의 구조성능을 고려하기 위해, 고유치해석을 통한 고유주기와 모드형상을 분석한다. 또한 비선형 정적해석을 통해 구조물의 강도와 변형성능을 분석한다.

변형과 부착강도 기반 철근 부식에 의한 RC구조물의 구조적 성능 평가 (Determination of Structural Capacity Based on Deformation and Bond Strength for RC Structure at Steel Corrosion)

  • 이정욱;안기용
    • 한국건설순환자원학회논문집
    • /
    • 제11권4호
    • /
    • pp.449-457
    • /
    • 2023
  • 본 연구에서는 철근의 부식에 대한 콘크리트의 구조적 한계를 실험적으로 정의하였다. 구조적 한계는 (1) 항복 시 콘크리트의 변형, (2) 최대 부착강도, (3) 부식되지 않은 시험체 수준의 부착강도로 고려하였다. 철근 표면에서 전하를 추출하는 전기화학적 방식을 이용하여 철근 부식을 촉진시켰다. 그 결과, 철근 직경이 증가할수록 부식 정도가 증가하여 콘크리트 변형은 항복상태에 도달하는 것으로 나타났다. 또한 철근 직경의 증가는 최대 부착강도와 부식되지 않은 수준의 부착강도에 도달되기 위한 전류 인가량을 증가시켰다. 그러나 질량 손실은 철근 크기에 미미하게 영향을 받았는데, 이는 구조적 성능의 매개변수(콘크리트 변형, 부착강도의 변화)를 통해 철근 부식에 의한 구조물의 사용수명을 대변할 수 있음을 의미한다.

Analytical model of corrosion-induced cracking of concrete considering the stiffness of reinforcement

  • Bhargava, Kapilesh;Ghosh, A.K.;Mori, Yasuhiro;Ramanujam, S.
    • Structural Engineering and Mechanics
    • /
    • 제16권6호
    • /
    • pp.749-769
    • /
    • 2003
  • The structural deterioration of concrete structures due to reinforcement corrosion is a major worldwide problem. Service life of the age-degraded concrete structures is governed by the protective action provided by the cover concrete against the susceptibility of the reinforcement to the corrosive environment. The corrosion of steel would result in the various corrosion products, which depending on the level of the oxidation may have much greater volume than the original iron that gets consumed by the process of corrosion. This volume expansion would be responsible for exerting the expansive radial pressure at the steel-concrete interface resulting in the development of hoop tensile stresses in the surrounding cover concrete. Once the maximum hoop tensile stress exceeds the tensile strength of the concrete, cracking of cover concrete would take place. The cracking begins at the steel-concrete interface and propagates outwards and eventually resulting in the through cracking of the cover concrete. The cover cracking would indicate the loss of the service life for the corrosion-affected structures. In the present paper, analytical models have been developed considering the residual strength of the cracked concrete and the stiffness provided by the combination of the reinforcement and expansive corrosion products. The problem is modeled as a boundary value problem and the governing equations are expressed in terms of the radial displacement. The analytical solutions are presented considering a simple 2-zone model for the cover concrete viz. cracked or uncracked. A sensitivity analysis has also been carried out to show the influence of the various parameters of the proposed models. The time to cover cracking is found to be function of initial material properties of the cover concrete and reinforcement plus corrosion products combine, type of rust products, rate of corrosion and the residual strength of the cover concrete. The calculated cracking times are correlated against the published experimental and analytical reference data.

3% NaCl 수용액중에서 복합조직강의 부식피로거동에 미치는 제2상 속도변화의 영향 (Effect of the change of second phase hardness on corrosion fatigue behavior of dual phase steel in 3% nacl solution)

  • 오세욱;김웅집
    • 한국해양공학회지
    • /
    • 제6권2호
    • /
    • pp.85-93
    • /
    • 1992
  • The only hardness of 2nd phase of martensite in dual phase steel which was composed of the martensite and ferrite was changed. Fatigue test was conducted by cantilever type of self-made rotated bending fatigue testing machine. The corrosion fatigue fracture behaviors of dual phase steel were investigated in 3% NaCl solution at $N_f$ = $1.5\times$$10^5$ $N_f$=1.0 $\times$ $10^6$ cycles. The fatigue strength was increased with increasing the hardness of 2nd phase. The size and number of corrsion pits were influenced by the 2nd phase hardness and pits remain constant in size just after they were transited into cracks. The life of crack initiation was effected by stress level. The shape of relation of $\Delta$K and da/dn has smaller scattering in it in 3% NaCl solution than that in air. The higher the 2nd phase hardness is, the higher the corrosion fatigue life becomes. Corrosion fatigue fracture behavior was effected by mechanics in case of $N_f$=1.5$\times$10$^5$$N_f$=1.5$\times$10$^6$ cycles.

  • PDF

다양한 코팅재를 이용한 콘크리트 중 철근의 부식 억제에 관한 연구 (A Study on Reducing the Corrosion of Steel Rebar Embedded in Concrete using Various Materials of Coating)

  • 송일현;이용수;류재석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.179-180
    • /
    • 2010
  • 본 연구에서는 염분 혼입량을 6단계로 나누어 시험을 실시하였다. 이때 코팅재와 염분 혼입량 외의 영향인자에 대한 영향을 줄이기 위해서 모르타르의 구성 성분은 동일하게 하여 시편을 제작하였으며 부식 결과를 빠른 시간내에 도출하기 위하여 부식 촉진법을 사용하여 20주간 시험을 실시하였다. 20주 동안 Galvanic과 Half-cell을 통하여 부식 개시시기에 대한 모델링을 하였으며, 싸이클 완료 후 Linear polarization을 이용하여 부식 전류를 측정하였으며, 철근을 모르타르와 동일한 방법으로 코팅하여 콘크리트에 적용 부식개시 시기를 알아보았다.

  • PDF

음용수질의 안정성을 위한 부식지수제도의 도입 (Introduction of Corrosion Index System for Stability of Drinking Water Quality)

  • 김영관;김진근
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.707-717
    • /
    • 2011
  • Replacement of old water distribution pipes for protecting water quality induced by pipe corrosion requires enormous budget. Even after the replacement, however, corrosion can occur again at any times and, therefore, inhibitive measure of the corrosion will be not only economical but needed to diminish the consumers' distrust on tap water quality. In 2008, National Environmental Research Institute did a survey on 8 major drinking water source and proposed to establish the Langelier Saturation Index(LI) as a corrosion index in Drinking Water Quality Criteria. Among the water industries of Korea, K-Water is the only one that set up the level of pH over 7.0 and LI above -1.5 on yearly average basis. However, no systematic regulation including LI to inhibit the corrosive tendency has been established yet. In this paper, LI values out of 31 drinking water treatment plants were analyzed and two-stage control of LI value as a measure of corrosive tendency of water is proposed. Primarily, water treatment facilities may operate the system at a target LI value below -1.5. Following the investigation on the effect caused by adjusting the LI value on water quality and corrosiveness, it will be desirable to improve LI value below -1.0 in the long run. In addition to the LI, supplemental use of Larson's modified ratio (LMR) which incorporates hydraulic detention time will be necessary. Several methods to prove the inhibitive effect of improving the LI value on water quality have been also suggested.

무연솔더 동판부식 시험법 연구 (Cu Corrosion Test Method for Lead-Free Solders)

  • 김미송;홍원식;오철민;김근수
    • Journal of Welding and Joining
    • /
    • 제35권3호
    • /
    • pp.21-27
    • /
    • 2017
  • A soldering temperature of ($235{\pm}3$) $^{\circ}C$ is described in ISO 9455-15 for the copper corrosion test. However, this temperature is not suitable for performing lead-free solder pastes. We evaluated the compatibility of a lead-free solder paste in the experimental conditions of (Liquidus temperature + ($35{\pm}3$)) $^{\circ}C$. Based on the results after a Cu corrosion test, a proper temperature for Pb-free soldering was (melting point+($35{\pm}3$)) $^{\circ}C$. Criteria used to evaluate corrosion due to discoloration of flux residue is described in ISO 9455-15, but a more quantitative evaluation standard is needed. In this study, experimental error level was estimated by analyzing flux residue after a corrosion test for 72, 500 hours of specimens using EDS analysis with acceleration voltage. It was determined that the copper area at the flux residue boundary is suitable for the EDS analysis area.