• Title/Summary/Keyword: Corrosion Protection System

Search Result 172, Processing Time 0.037 seconds

The Development of The Remote Real-Time Corrosion Monitoring and Control System Using by TRS for Maritime Metallic Structures (TRS를 이용한 해양구조물의 원격 실시간 부식감시 및 방식 제어시스템 개발)

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong;Choi, Sang-Bong;Jeong, Seong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2000.11d
    • /
    • pp.657-659
    • /
    • 2000
  • The importance of total management for maritime structures (Ports, Piers, docks. marine bridges, marine roads, submarine pipelines, etc.) is more and more increasing in these days. Especially, in spite of the marine structures are exposed at the various corrosion circumstances, there are not only a standard of Cathodic Protection System but also knowledge of importance for necessity of corrosion monitoring. Therefore, this paper presents the results of development for the Remote Real-Time Corrosion Monitoring and Control System Using by TRS on Maritime Metallic Structures which can be prevents a big accident by corrosion.

  • PDF

A study of Protection for electrical corrosion by stray current in DC railway system (직류전기철도시스템에서의 누설전류에 의한 전식방지에 대한 연구)

  • Lee Jae-young
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.748-753
    • /
    • 2005
  • The stray current(leakage current) in DC railway system like as Metro Subway and LRT system happens electrical corrosion on theses superstructure facilities and also underground facilities that causes the public property losses. we must study and establish on the theoretical concept and concrete phenomena for electrical corrosion, In the construction period we intend to review and find out a lot of solution to minimize theses losses. we must investigate, measure and analysis natural atmosphere of these facilities locations to present a maintenance management guide for the upcoming operation stage.

  • PDF

Study on New Candidate Coating Materials to Challenge Rudder Cavitation Damage

  • Lee, H.I.;Han, M.S.;Baek, K.K.;Lee, C.H.;Shin, C.S.;Chung, M.K.
    • Corrosion Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.274-282
    • /
    • 2008
  • Ships' hull is typically protected by a combination of protective coating system and electrical cathodic protection system, which has been an economical and effective measure for ship's hull to date. However, ships' rudder and adjacent hull areas are known to be subjected to premature corrosion damages, which require more frequent coating repair than other hull areas. Conventional organic coating system for ship's hull has been known only to remain intact just for 2~3 months on the rudder and adjacent area, especially for the fast-going ships such as container carriers or naval vessels. In this study, special organic/inorganic coating materials, which are commercially available, were tested in terms of cavitation resistance as an alternative to existing rudder & hull protection system. Both standard ultrasonic tester and in-house developed ultra water jet test method were employed as a means to evaluate their performance against cavitation induced damages. Additionally, the overall cost evaluation and workability at actual shipyard were discussed.

A Study on Development of Cathodic Protection on Underground Pipeline Measuring System (매설배관의 방식전위 측정시스템 개발에 관한 연구)

  • Kim, Jin-Jun;Seo, Min-Sung;Kim, Dong-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.5
    • /
    • pp.66-71
    • /
    • 2014
  • Gas pipelines are the core facilities in the gas facilities and the most pipelines are buried underground and are exposed to the risk of corrosion caused by the soil characteristics and the environmental impact. The anti-corrosion potential and the corrosion status of the underground pipelines are measured periodically in accordance with the relevant laws and regulations. A study on the cathodic protection measurement system was carried out in order to solve the problems of the conventional measurement system. This paper describes the survey on the standards and the specifications of the cathodic protection measurement and the the reference electrode to meet the relevant regulations, and the development of the measuring circuit and the data transmission module to build the cathodic protection measurement system. This study verified the field applicability through the testing of the developed prototype and investigated on the problems of the previous studies and the future research and development direction.

Management Criteria of Underground Strage Tank for Prevention of Soil Contamination (토양오염방지를 위한 지하저장탱크의 관리 방안 연구)

  • Kim, Joon Hyun;Han, Young Han
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.453-460
    • /
    • 1998
  • The purpose of this study was to analyze their status of underground storage tank(UST) facilities and level of soil contamination, and to establish its management criteria. DB program was developed to analyze the correlation between specific characteristic of UST and level of soil contamination. For a suitable management of UST, leakage monitoring and inspection method of UST was investigated. Inspection period was established based on the leakage rate. The most dominant factor for leakage seemed to be caused by the corrosion. Therefore, main factor, construction method and installation year of UST, and corrosion protection system were suggested for optimal protection of UST. Considering the present management status of UST in Korea, inspection and management criteria of UST should be accomplished in term of contamination protection of leakage, and flexible regulation act should be introduced for each specific site.

  • PDF

Comparison Analysis of Field Test Methods Based on Technical Criteria of Electrolytic Corrosion Protection in Urban Railway (도시철도 전식방지 기술기준에 따른 시험방법 비교분석)

  • Kim, Jae-Moon;Jung, Ho-Sung
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1885-1891
    • /
    • 2010
  • Recently metropolitan local governments is actively introducing urban railway's expand and light rail transit as a means of new transport system. DC electricity feeder system operating in the domestic urban railway is typically a feedback circuit consisted of the contact wire and electric railway vehicle via rail. But stray current is to be defined as a current flowing on a structure that is not part of the intended electrical circuit with respect to a given structure. Stray current is generally results from the leakage of return currents from large DC traction systems that are grounded or have a bad earth-insulated return path. At the place where the current leaves the rail and metallic structures, electrolytic corrosion may take place. This paper presents comparison analysis of field test methods based on criteria of electrolytic corrosion protection of buried metallic structures adjacent to DC traction systems.

  • PDF

The study on the influence of surface cleanness and water soluble salt on corrosion protection of epoxy resin coated carbon steel

  • Shon, MinYoung
    • Corrosion Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.163-169
    • /
    • 2014
  • The corrosion resistance of epoxy-coated carbon steel was evaluated. The carbon steel surface was subjected to different treatment methods such as steel grit blasting and power tool treatment as well as contamination of water soluble salt. To study the effect of the surface treatments and contamination, the topology of the treated surface was observed by confocal microscopy and a pull-off adhesion test was conducted. The corrosion resistance of the epoxy-coated carbon steel was further examined by electrochemical impedance spectroscopy (EIS) combined with immersion test of 3.5 wt% of NaCl solution. Consequently, the surface contamination by sodium chloride with $16mg/m^2$, $48mg/m^2$ and $96mg/m^2$ didn't affect the adhesion strength for current epoxy coated carbon steel and blister and rust were not observed on the surface of epoxy coating contaminated by various concentration of sodium chloride after 20 weeks of immersion in 3.5 wt% NaCl aqueous solutions. In addition, the results of EIS test showed that the epoxy-coated carbon steel treated with steel grit blasting and power tool showed similar corrosion protection performance and surface cleanness such as Sa 3 and Sa 2.5 didn't affect the corrosion protectiveness of epoxy coated carbon steel.

An Experimental Study on the Steel Corrosion Control in Concrete by using the Sacrificial Anode System (희생양극법을 응용한 콘크리트중의 철근부식 억제에 대한 실험적 연구)

  • 문한영;김성수;류재석;김홍삼;김성섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.191-196
    • /
    • 1997
  • Steel is the most used as materials for construction and corrosion expansion of steel due to outdoor corrosive environmental factor bring serious problem on the durability of concrete structures time after time. It is the purpose of this study to see whether it is effective of not, when sacrificial anode method is adapted. Indoor accelerated corrosion testing was carried out to see its effective in a short term. From the mid result, potential of steel in concrete in case of adapting sacrifice anode method satisfacts protection standard value (less than-850mV vs CSE), therefore sacrificial anode method is considered as a proper protection steps against corrosion of steel.

  • PDF

Characteristics of Cathodic Protection with ICCP Anode in Reinforced Concrete (철근콘크리트용 ICCP 양극의 종류별 음극방식 특성)

  • Jeong, Jin-A
    • Corrosion Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.112-119
    • /
    • 2012
  • This paper presents the results of a study of the effectiveness of cathodic protection with insoluble ICCP anode in reinforced concrete structures. Experimental tests were carried out on reinforced concrete specimens with 3 different commercial anodes for ICCP system in order to compare the effectiveness of cathodic protection. Results have shown that the kinds of anode for ICCP is irrelevant to the effectiveness of cathodic protection, In case of ICCP, the performance of cathodic protection has no relationship to the kinds of anode especially in concrete specimens with sea water condition. It has been found slightly more effective at Ti-Rod anode in fresh water condition and Ti-Mesh anode in atmospheric condition.