• 제목/요약/키워드: Corrosion Current Cell

검색결과 94건 처리시간 0.026초

MMO(Ti/Ru) 코팅된 타이타늄의 고분자 전해질 연료전지 양극환경에서의 전기화학적 거동 (Electrochemical Characteristics of MMO(Ti/Ru)-Coated Titanium in a Cathode Environment of Polymer Electrolyte Membrane Fuel Cell)

  • 허호성;김성종
    • Corrosion Science and Technology
    • /
    • 제21권5호
    • /
    • pp.340-347
    • /
    • 2022
  • In this research, mixed metal oxide (TiO2, RuO2) coating was applied to grade 1 titanium as a bipolar plate for polymer electrolyte membrane fuel cell (PEMFC). Electrochemical experiments were carried out in an aqueous solution of pH 3 (H2SO4 + 0.1 ppm HF, 80 ℃) determined by DoE. The air was bubbled to simulate a cathode environment. Potentiodynamic polarization test revealed that corrosion current densities of the titanium substrate and MMO-coated specimen were 0.180 µA/cm2 and 4.381 µA/cm2, respectively. There was no active peak. After potentiostatic experiment, current densities of the titanium substrate and the MMO-coated specimen were 0.19 µA/cm2 and 1.05 µA/cm2, respectively. As a result of observing the surface before and after the potentiostatic experiment, cracked dried clay structures were observed without corrosion damage. Both the titanium substrate and the MMO-coated specimen could not satisfy the interfacial contact resistance suggested by the DoE. Thus, further research is needed before they could be applied as bipolar plates.

MCFC 분리판 부식거동에 관한 연구 (Corrosion behavior of separator for molten Cab -onate Fuel Cell)

  • 이성일;김귀열
    • 대한안전경영과학회지
    • /
    • 제2권4호
    • /
    • pp.177-186
    • /
    • 2000
  • The molten carbonate fuel cell has conspicuous features and high potential in being used as an energy converter of various fuels to electricity and heat. However, the MCFC which use strongly corrosive molten carbonate at $650^{\circ}C$ have many problem. Systematic investigation on corrosion behavior of Fe/20Cr/Ti has been done in (62+38)mol % (Li+K) $CO_3$ melt at 923K by using. steady state polarization and electrochemical impedance spectroscopy method. It found that the corrosion current of these Febased alloys decreased with increasing Ti content, and this attribute to the formation of $LiCrO_2$ layer at the surface.

  • PDF

피로하중을 받는 해양 콘크리트의 내구성 연구 (DURABILITY TESTING OF MARINE REINFORCED CONCRETE UNDER FATIGUE LOADING, PART I AND II)

  • 안우석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 봄 학술발표회 논문집
    • /
    • pp.348-353
    • /
    • 1996
  • This study addresses the evaluation of the durability of reinforced concrete marine structures subjected to fatigue loading. The laboratory investigation was carried out on full and half size reinforced concrete specimens with three different water cement ratios (0.3, 0.4, and 0.56), static and fatigue loading conditions, and epoxy-coated and regular black steel reinforcements. The marine tidal zone was simulated by alternate filling and draining of the tank (wet and dry cycled), and a galvanostatic corrosion technique to accelerate corrosion of reinforcement was used. Half-cell potentials and changes of crack width were measured periodically during the exposure and followed by ultimate strength testing. The significant findings include adverse effect of fatigue loading, existence of an explicit size effect, poor performance of epoxy coated steel, and negative effect of increasing water/cement ratio.

  • PDF

니켈 표면처리공정에서 전류밀도 효과분석 (Effect of Current Density on Nickel Surface Treatment Process)

  • 김용운;정구형;홍인권
    • 공업화학
    • /
    • 제19권2호
    • /
    • pp.228-235
    • /
    • 2008
  • 니켈 표면처리 공정에서 전류밀도에 따라 니켈의 전착두께가 증가되었으며, 증가폭은 $6{\sim}10A/dm^2$에서 저전류보다 높게 나타났다. 전류밀도를 측정하기 위해 Hull-cell 분석을 수행 하였다. 최적 공정온도는 $60^{\circ}C$, pH는 3.5~4.0이었고, 전해용액 중 니켈이온의 농도는 300 g/L 이상에서 농도에 따라 전착두께가 증가되었다. 전류밀도에 따라 용액 중 니켈이온 감소 속도가 증가되었는데, 이는 음극표면에서 니켈 전착 량에 따른 전착두께의 증가를 나타낸다. 그러나 전착속도가 빠를 경우 니켈 전착 층의 치밀성은 저하되며, 표면의 상태는 불규칙하게 변화된다. 니켈이온의 전착과정이 불규칙하게 일어나 조직의 pin hole 등을 야기해 표면특성을 저하시키는 것으로 확인되었다. 광택니켈 전착 후 25 h 내식을 유지한 결과, 낮은 전류밀도를 유지하는 것이 내식특성이 우수한 것으로 나타났다. 프로그램모사 결과, 전류밀도가 높아질수록 확산 층의 두께는 증가하며, 음극표면의 농도는 낮아진다. 농도분포는 낮은 전류밀도에서 고른 분포를 나타내었으며 이는 일정한 전착두께를 예측할 수 있다. 생산성 저하를 예방하기 위해 공정시간은 크게 변화시키지 않았으며, 전류밀도와 전착두께를 변화시키면서 공정변수를 조절하였다. 본 연구의 표면분석 결과 조직특성이나 내식성 등의 표면 물성이 낮은 전류밀도를 사용할 경우에 더욱 우수한 것으로 나타났다.

임피던스법을 적용한 연료전지의 성능평가 (Analysis on the Fuel Cell Performance by the Impedance Method)

  • 김귀열
    • 한국전기전자재료학회논문지
    • /
    • 제20권10호
    • /
    • pp.918-923
    • /
    • 2007
  • Fuel cell is a modular, high efficient and environmentally energy conversion device, it has become a promising option to replace the conventional fossil fuel based electric power plants. The high temperature fuel cell has conspicuous feature and high potential in being used as an energy converter of various fuel to electricity and heat. Corrosions in molten electrolytes and the electric conductivity across the oxide scale have crucial characteristics. When molten salts are involved, high temperature corrosions become severe. In this sense, corrosions of alloys with molten carbonates have the most severe material problems. Systematic investigation on corrosion behavior of Fe/21Cr/Ti or Al alloy has been done in (62+38)mol% (Li+K)$CO_3$ melt at $650^{\circ}C$ using the electrochemical impedance spectroscopy method. It was found that the corrosion current of these Fe-based alloys decreased with increasing Al or Ti. And Al addition improved the corrosion resistance of this type of specimen and more improvement of corrosion resistance was observed at the specimen added with Al.

전기저항형 센서 및 전기화학적 방법을 이용한 철근콘크리트 구조물의 부식속도 측정 방법에 관한 연구 (Study on The Corrosion Rate Monitoring of Steel in Concrete Using Electric resistance Sensor and Electrochemical Methods.)

  • 조용범;김용철;장상엽;고영태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.1185-1192
    • /
    • 2001
  • This paper reviews available techniques for monitoring corrosion of steel in concrete. The need for early detection and diagnosis of corrosion related deterioration in reinforced structures is widely acknowledged. This is particularly important in reinforced concrete structures on account of the economic and social significance of the problem. The current generally used on-site procedure for corrosion monitoring of reinforced structures employs a method of half-cell surface potential measurements. While the technique has provided a useful means of delineating areas of high or low corrosion risk, there are difficulties in its use and interpretation when assessing rates of deterioration. Electrochemical techniques are by far the most suitable for corrosion monitoring purpose and meet most of the requirements. The aim of this paper is to describe the electric resistance sensor(ER sensor) and electrochemical techniques employed to monitor and estimate corrosion rates of reinforcement. Early detection and diagnosis of corrosion hazards allows preventive measures to be taken, hence the typically expensive repair of severely deteriorated structures can be avoided.

  • PDF

다양한 코팅재를 이용한 콘크리트 중 철근의 부식 억제에 관한 연구 (A Study on Reducing the Corrosion of Steel Rebar Embedded in Concrete using Various Materials of Coating)

  • 송일현;이용수;류재석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.179-180
    • /
    • 2010
  • 본 연구에서는 염분 혼입량을 6단계로 나누어 시험을 실시하였다. 이때 코팅재와 염분 혼입량 외의 영향인자에 대한 영향을 줄이기 위해서 모르타르의 구성 성분은 동일하게 하여 시편을 제작하였으며 부식 결과를 빠른 시간내에 도출하기 위하여 부식 촉진법을 사용하여 20주간 시험을 실시하였다. 20주 동안 Galvanic과 Half-cell을 통하여 부식 개시시기에 대한 모델링을 하였으며, 싸이클 완료 후 Linear polarization을 이용하여 부식 전류를 측정하였으며, 철근을 모르타르와 동일한 방법으로 코팅하여 콘크리트에 적용 부식개시 시기를 알아보았다.

  • PDF

Evaluation of Metals (Al, Fe, Zn) in Alternative Fuels by Electrochemical Impedance Spectroscopy in Two Electrode Cell

  • Song, Yon-Kyun;Lim, Geun-Woong;Kim, Hee-San
    • Corrosion Science and Technology
    • /
    • 제9권2호
    • /
    • pp.92-97
    • /
    • 2010
  • Many kinds of alternative fuels such as biodiesel, ethanol, methanol, and natural gas have been developed in order to overcome the limited deposits in fossil fuels. In some cases, the alternative fuels have been reported to cause degrade materials. The corrosion rates of metals were measured by immersion test, a kind of time consuming test because low conductivity of these fuels was not allowed to employ electrochemical tests. With twin two-electrode cell newly designed for the study, however, electrochemical impedance spectroscopy (EIS) test was successfully applied to evaluation of the corrosion resistance ($R_p$) of zinc, iron, aluminum, and its alloys in an oxidized biodiesel and gasoline/ethanol solutions and the corrosion resistance from EIS was compared with the corrosion rate from immersion test. In biodiesel, $R_p$ increased in the order of zinc, iron, and aluminum, which agreed with the corrosion resistance measured from immersion test. In addition, on aluminum showing the best corrosion resistance ($R_p$), the effect of magnesium as an alloying element was evaluated in gasoline/ethanol solutions as well as the oxidized biodiesel. $R_p$ increased with addition of magnesium in gasoline/ethanol solutions containing chloride and the oxidized biodiesel. In the mean while, in gasoline/ethanol solutions containing formic acid, Al-Mg alloy added 1% magnesium had the highest $R_p$ and the further addition of magnesium decreased $R_p$. It can be explained with the fact that the addition of more than 1% magnesium increases the passive current density of Al-Mg alloys.

고온의 인공해수 중 12Cr강의 부식피로특성에 관한 연구 (Corrosive Characterisics of 12Cr Alloy Steel and Fatigue Characteristics of the Artificially Degraded 12Cr Alloy Steel)

  • 조선영;김철한;배동호
    • 대한기계학회논문집A
    • /
    • 제25권5호
    • /
    • pp.772-778
    • /
    • 2001
  • In this study, corrosion fatigue characteristics of 12Cr alloy steel were investigated in 3.5wt.% NaCl solution of 150$^{\circ}C$ and 4.5bar. Behavior of corrosion fatigue cracks was measured by the indirect compliance method and compared with the results in distilled water and in air. 1) 12Cr alloy steel was susceptible to temperature. Its susceptibility was increased as the temperature was increased. 2) The crack growth characteristics of 12Cr alloy steel in distilled water were similar to 3.5wt.% NaCl solution. 3) The temperature of solution affects to the crack growth characteristics of 12Cr alloy steel. In corrosion solutions of 4.5bar, 150$^{\circ}C$, fracture surfaces of corrosion fatigue crack growth at a/W=0.3 was showed the trans-granular fracture suface. As the crack grew up, it was changed to inter-granular type. In condition of high temperature, The crack growth behaviors of 12Cr alloy steel were remarkable.

건조 상태의 시멘트 모르타르 특성과 철근 부식량을 고려한 HCP 평가 (HCP Evaluation Considering Property of Cement Mortar and Steel Corrosion)

  • 류화성;윤용식;권성준
    • 한국건설순환자원학회논문집
    • /
    • 제5권2호
    • /
    • pp.113-120
    • /
    • 2017
  • HCP 측정법은 철근부식을 판단하는 비파괴 시험으로 현장에서 효과적으로 사용되고 있다. 본 연구는 실내실험을 통하여 촉진부식실험을 수행하고 건조 상태에서 측정된 HCP 측정값과 부식량의 상관성을 분석하는 연구이다. 이를 위해 4가지 피복두께와 3가지 물-시멘트비를 가진 시멘트 모르타르 시편을 제조하여 6시간, 18시간, 42시간동안 20V의 전압을 가하여 ICM에 의한 촉진실험을 수행하였다. 분석결과 피복두께의 감소, 물-시멘트비의 증가, 촉진부식시간의 증가에 따라 부식량이 증가하였으며, 측정된 HCP 값과는 선형적인 관계를 나타내었다. HCP를 사용하여 부식량을 평가하기 위해서는 전체 부식량을 비교하는 것보다, 일정수준의 HCP 값을 선정하고 이에 따라 부식량을 평가하는 것이 높은 결정계수를 얻는 합리적인 방법으로 평가되었다.