• 제목/요약/키워드: Coronal Flaring

검색결과 25건 처리시간 0.02초

근관의 치경부 조기 확대가 치근단 잔사 정출에 미치는 효과 (THE EFFECT OF EARLY CORONAL FLARING ABOUT APICAL EXTRUSION OF DEBRIS)

  • 김민경;미정범;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제29권2호
    • /
    • pp.147-152
    • /
    • 2004
  • The purpose of this study was to investigate the quantity of debris which was extruded apically after canal instrumentation using different types of enlarging instrument in endodontic resin models. Five groups of 9 endodontic resin models were instrumented using each different technique : hand instrumentation without early coronal flaring. hand instrumentation after early coronal flaring. and three nickel-titanium engine-driven instrumentations (Hero 642, Protaper, $K^$). Debris extruded from apical foramen during instrumentation was collected on preweighed CBC bottle, desiccated and weighted using electronic balance. The results were analyzed using Kruskal-wallis test and Mann-Whitney U rank sum test at a significance level of 0.05. The results were as follows: 1. All of instrumentation techniques produced apically extruded debris. 2. Group without early coronal flaring extruded significant more debris than groups with early coronal flaring. 3. There was no significant difference among early coronal flaring groups. The early coronal flaring is very important to reduce the amount of debris extruded apically.

A study on the quantity of apical extrusion of debris according to early coronal flaring

  • Kim, Min-Kyung;Hwang, Ho-Keel
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.580-580
    • /
    • 2003
  • I. Objectives This study investigated the quantity of debris which was extruded apically after canal instrumentation using different types of enlarging instrument in endodontic resin models. II. Materials and Methods Five groups of 9 endodontic resin model were instrumented using each different technique:hand instrumentation without early coronal flaring, hand instrumentation after early coronal flaring, and three nickel-titanium engine-driven instrumentations(Hero 642, Protaper, K3) after early coronal flaring.(omitted)

  • PDF

Coronal flaring 전, 후 초기근관장 파일크기의 분석 (THE ANALYSIS OF INITIAL APICAL FILE SIZE BEFORE AND AFTER CORONAL FLARING)

  • 황호길;박찬호;배성철
    • Restorative Dentistry and Endodontics
    • /
    • 제28권1호
    • /
    • pp.64-71
    • /
    • 2003
  • The purpose of this study was to compare the initial apical file(IAF) first Ole that fits to the apex in each canal before and after early flaring to analyze if the size of file to fit to the apex would increase after flaring. Eighty anterior teeth with complete apical formation and patent foramens were selected. The samples were randomly divided into 4 groups(GG, OS, GT, PT Group) of 20 teeth each. A file was fit to the apex in each canal and that size recorded. Radicular flaring were completed using different types of instruments. After flaring a file was again fit to the apex in the same manner as before and its size recorded. The results of this study were as follows : 1. The mean diameter of IAF before flaring(file diameters in $mm{\times}10^{-2}$) was $19.81{\pm}8.32$ before and $25.94{\pm}9.21$ after(p<0.05). 2. The increase in diameter of IAF was approximately one file size for all groups. 3. Ranking of increasing diameter of IAF were GG>CT>OS>PT group. There was a statistically significant difference between before and after flaring(p<0.05). 4 Ranking of the time for flaring were GG>GT>OS>PT group. There was a statistically significant difference between GG group and other groups(p<0.05). 5. In the case without change of IAF diameter, they showed decrease in force after flaring when IAF was pulled out from root canal(p<0.05). This study suggested that early radicular flaring increases the file size that is snug at the apex, and awareness of that difference gives the clinician a better sense of canal size. Early flaring of the canal provides better apical size information and with this awareness, a better decision can be made concerning the appropriate final diameter needed for complete apical shaping.

Coronal flaring 전, 후의 근관세척효과 (THE IRRIGATING EFFECT BEFORE AND AFTER CORONAL FLARING)

  • 황호길;배성철;조영린
    • Restorative Dentistry and Endodontics
    • /
    • 제28권1호
    • /
    • pp.72-79
    • /
    • 2003
  • The objective of this in vitro study was to evaluate the efficacy of a Ca(OH)$_2$removal before and after early coronal flaring using different types of instruments. 100 plastic blocks with 30$^{\circ}$artificial curved canals were used in this study and randomly divided into a control group and 4 experimental groups(GG, OS, GT, PT Group) 20 teeth each. The canals were instrumented, and Ca(OH)$_2$was temporary filled into the each canal. Irrigation was peformed with Max-i-Probe 25- 30-gauge probes before and after recapitulation. The results of this study were as follows 1. There were no significant difference among the groups in size of irrigating needle(p<0.05). 2. There was a significant difference between before and after recapitulation regardless size of irrigating needle(p<0.05). 3. Before recapitulation, there was a significant difference between 25- and 30-gauge needle in all groups(P<0.05). 4. After recapitulation, there was a significant difference between 25- and 30-gauge needle in the control group(p<0.05). But there were no significant difference among the experimental groups. It is concluded that the effectiveness of canal irrigation was decided to the depth of irrigating needle into the canal. The effect of canal irrigation tend to facilitate by the early coronal flaring. The recapitulation was the most effective during canal irrigation regardless the size of irrigating needle. Therefore, the recapitulation is a mandatory way to facilitate the effectiveness of canal irrigation during canal enlargement.

하악구치 근심근의 해부학적 형태와 근관확대방법이 Coronal flaring에 미치는 영향에 관한 연구 (A STUDY OF THE ANATOMY OF MANDIBULAT MOLAR & THE EFFECT OF VARIOUS INSTRUMENTATION ON CORONAL FLARING)

  • 이세종;안병두;최기운;임미경
    • Restorative Dentistry and Endodontics
    • /
    • 제16권2호
    • /
    • pp.174-181
    • /
    • 1991
  • A model system was used which enabled the same root canal system to be measured before and after coronal flaring of 51 extracted mandibular molars. The concavity of the distal surface of the mesial root was measured and the amount of reduction was compared after coronal flaring using step-back flared preparation, Gates-Glidden dirll or ultrasonic system(Quick-$\varepsilon$) at the furcation and apical 3mm from the furcation. The results were as follows: 1. The mean concavity of mesial root of manchbular molar was $0.73{\pm}0.27mm$ at the bifurcation and $0.65{\pm}0.23mm$ at the 3.0mm apical from the bifurcation. 2. The thickness of the root canal wall of the mesiobuccal canal was $1.08{\pm}0.26mm$ at the bifurcation and $1.00{\pm}0.23mm$ at the 3.0mm apical from the bifurcation. 3. The thickness of the root canal wall of the mesiolingual was $1.09{\pm}0.21mm$ at the bifurcation and $0.98{\pm}0.29mm$ at the 3.0mm apical from the bifurcation. 4. In the amount of reduction at the furcation and at the 3.0mm apical from the furcation there was no statistically significant difference between the step-back preparation and Gates-Glidden drill preparation, and ultrasonic preparation(P>0.05).

  • PDF

하악대구치 근심치근의 협설측 근관장의 비교 (A COMPARISON OF THE LENGTH BETWEEN MESIO-BUCCAL AND MESIO-LINGUAL CANALS OF THE MANDIBULAR MOLAR)

  • 박슬희;노봉환;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제29권6호
    • /
    • pp.541-547
    • /
    • 2004
  • The aim of this study was to compare the initial apical file (IAF) length between the mesio-buccanl and mesio-lingual canals of the mandibular molar before and after early coronal flaring. Fifty mandibular molars with complete apical formation and patent foramens were selected. After establishing the initial working length of the buccal and lingual canal of the mesial root using the Root-ZX, radiographs were taken for the working length with a 0.5 mm short of #15 K-file tip just visible at the foramen under a surgical microscope (OPMI 1-FC, Carl Zeiss Co. Germany) at 25X. After early coronal flaring using the $K^3$ file, additional radiographs were taken using the same procedure. The root canal morphology and the difference in working length between the buccal and lingual canals were evaluated. These results show that the difference in the length between the mesio-buccal and mesio-lingual canals of the mandibular molar was $\leq$ 0.5 mm. If one canal has a correct working length for the mesial root of the mandibular molar, it can be used effectively for measuring the working length of another canal when the files are superimposed or loosening. In addition, the measured the working length after early coronal flaring is much more reasonable because the difference in the length between the mesio-buccal and mesio-lingual canals can be reduced.

하악 대구치 근심근관에 대한 전자근관장 측정기의 정확도 (AN ACCURACY OF THE SEVERAL ELECTRONIC APEX LOCATORS ON THE MESIAL ROOT CANAL OF THE MANDIBULAR MOLAR)

  • 조영린;손욱희;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제30권6호
    • /
    • pp.477-485
    • /
    • 2005
  • 근단부위 형성이 완료되고 우식이 없는 하악 대구치 근심치근 50개를 대상으로 주파수 의존형 전자근관장 측정기를 이용하여 측정한 근관장의 정확도를 평가하기 위해 치수강 개방 후 동일한 치아에서 방사선 사진으로 확인한 실측 근관장을 대조군, 각종 전자근관장 측정기로 측정한 근관장을 실험군 ( I군: Root-ZX, II군: Bingo, III군: Propex, IV군: Diagnostic)으로 분류하여 근심협측과 설측의 근관장을 근관의 입구 측으로부터 치근단 1/3까지 확대여부 및 서로 다른 측정시기에 측정하여 비교 평가한 결과 다음과 같은 결론을 얻었다. 하악대구치 근심치근의 협측과 설측 전자근관장은 측정기의 종류, 근관의 입구 측으로부터 치근단 1/3까지의 확대여부 및 측정시기에 상관없이 0.5mm이내의 오차범위를 나타내었으며, 근관치료시 오차한계인 ${\pm}1mm$에서 정확성은 근관의 입구 측으로부터 치근단 1/3까지 미리 확대한 후에 근관장을 측정할 경우와 측정시기가 반복될 경우에 증가되는 경향을 보여 임상에 유용하게 활용할 수 있을 것으로 사료된다.

Selection of Nickel-Titanium Files according to the Clinical Procedure and Factors of File Fracture: A Narrative Review

  • Hyeon-Cheol, Kim
    • Journal of Korean Dental Science
    • /
    • 제15권2호
    • /
    • pp.112-120
    • /
    • 2022
  • In this article, the contemporary root canal treatment procedure using nickel-titanium (NiTi) instruments was reviewed to understand the correlations between the properties of files and safety of the clinical usage. Literatures were reviewed according to the process of clinical procedure of the root canal preparation, mainly for shaping during orifice flaring, glide-path preparation, and main canal instrumentation. Considering the reasons for NiTi file fracture, clinically implacable issues and ideas were discussed to reduce the fracture risk and increase clinical efficiency of the NiTi file systems. Various kinds of NiTi file systems have their own characteristics and properties given from their geometries and heat treatments and so on. Proper selection and careful usage of the NiTi file systems may reduce the risk of file fracture and increase the efficiency of NiTi file systems. Understanding of the clinical implications from the mechanical properties and characteristics of the engine driven NiTi instruments may decrease the risk of NiTi file fractures and increase the success rate in root canal treatment.

만곡근관에서 근관형성법에 따른 근관작업장의 변화 (Change of working length in curved canals by various instrumentation techniques)

  • 조정임;진명욱;김영경;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제31권1호
    • /
    • pp.30-35
    • /
    • 2006
  • 만곡근관에서 근관형성방법에 따른 근관작업장 변화를 평가하기 위하여 발거된 대구치의 협측 또는 근심 근관 40개에서 스테인레스-스틸 수동 파일 ($MANI^{(R)}$, 일본), 니켈-티타늄 수동 파일 (Naviflex $NT^{TM}$, 미국), ProFile, 또는 $ProTaper^{TM}$ (Dentsply-Maillefor, 스위스)를 사용하여 crown-down 방법으로 30번 크기까지 근관을 형성하고 근관형성 전후의 근관작업장 및 만곡도의 변화를 관찰하였다. 근단공에 대한 10-K파일 끝의 위치변화를 AutoCAD2000 (Autodesk 사, 미국)으로 측정하고 일원변량분석법 및 Tukey's studentized range test로 통계 분석하였다. 모든 군에서 근관형성후 근관장 및 만곡도가 유의하게 감소하였으며, 치관부 근관형성시 Gates Glidden bur를 사용한 수동파일 군이 ProFile 군보다 유의하게 많은 근관장 감소를 초래하였고, 치관부 및 근단부 전체 근관형성후에는 스테인레스 스틸 수동파일 군이 ProFile 군에서보다 유의하게 많은 근관장 감소를 나타내었다 (p<0.05).

RESULTS FROM THE YOHKOH SATELLITE

  • WATANABE TETSUYA
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.291-294
    • /
    • 1996
  • The .Japanese sun observing satellite, Yohkoh, has been operational for five years and her scientific instruments are still in good condition. They have revealed ample of evidences that solar flares were triggered by magnetic reconnection, which was, for the first time, clearly indicated to take place in the solar corona. Cusp structures in soft X-rays and a new type of hard X-ray sources at the top of flaring loops have strongly supported the scenario originally proposed by C-S-H-KP. Nonthermal energy input in hard X-rays and thermal energy estimated from soft X-rays are fundamentally consistent with the interpretation of thick-target and chromospheric-evaporation models (Neupert effect). X-ray jets, another discovery of Yohkoh, were also associated with magnetic reconnection, as a result of the interaction of emerging fluxes with pre-existing coronal loops. Temperature structures of active regions, quiet sun, and coronal holes had very dynamic differential-emission-measure (DEM) distributions and high-temperature tails of DEM were considered to come from the contribution of flare-like activity.

  • PDF