DOI QR코드

DOI QR Code

Change of working length in curved canals by various instrumentation techniques

만곡근관에서 근관형성법에 따른 근관작업장의 변화

  • Jo, Jeong-Im (Department of Conservative Dentistry, School of Dentistry, Kyungpook National University) ;
  • Jin, Myoung-Uk (Department of Conservative Dentistry, School of Dentistry, Kyungpook National University) ;
  • Kim, Young-Kyung (Department of Conservative Dentistry, School of Dentistry, Kyungpook National University) ;
  • Kim, Sung-Kyo (Department of Conservative Dentistry, School of Dentistry, Kyungpook National University)
  • 조정임 (경북대학교 치의학대학원 치과보존학교실) ;
  • 진명욱 (경북대학교 치의학대학원 치과보존학교실) ;
  • 김영경 (경북대학교 치의학대학원 치과보존학교실) ;
  • 김성교 (경북대학교 치의학대학원 치과보존학교실)
  • Published : 2006.01.01

Abstract

To evaluate the change of working length with various instrumentation techniques in curved canals, working length and canal curvature were determined before and after canal instrumentation in buccal or mesial canals of extracted human molars. Stainless steel K-files ($MANI^{(R)}$, Matsutani Seisakusho Co. Takanezawa, Japan), nickel-titanium K-files (Naviflex $NT^{TM}$, Brassier, Savannah, USA) , $ProFile^{(R)}$, and ProTaper (Dentsply-Maillefer, Ballaigues, Switzerland) were used to prepare the canals with crown-down technique. In two hand instrumentation groups coronal flaring was made with Gates Glidden burs. Apical canals were instrumented until apical diameter had attained a size of 30. Positional relation between the tooth apex and the $\#10$ K-file tip was examined by using AutoCAD 2000 (Autodesk Corp., San Rafael. CA, USA) under a stereomicroscope before and after coronal flaring, and after apical instrumentation. Degree of canal curvature was also measured with Schneider's method in radiographs. Data of working length and canal curvature changes were statistically analyzed with one-way ANOVA and Tukey's studentized range test. Working length and canal curvature were decreased significantly in each step in all instrumentation groups. Coronal flaring using Cates Glidden burs in hand instrument groups and whole canal instrumentation using stainless steel hand K-files caused significantly more working length change than in ProFile instrumentation group (p<0.05). The result of this study demonstrates that all of the above kinds of instrumentation in curved canals cause reduction of working length and canal curvature at each instrumentation steps, and hand instrumentation causes more working length change than ProFile.

만곡근관에서 근관형성방법에 따른 근관작업장 변화를 평가하기 위하여 발거된 대구치의 협측 또는 근심 근관 40개에서 스테인레스-스틸 수동 파일 ($MANI^{(R)}$, 일본), 니켈-티타늄 수동 파일 (Naviflex $NT^{TM}$, 미국), ProFile, 또는 $ProTaper^{TM}$ (Dentsply-Maillefor, 스위스)를 사용하여 crown-down 방법으로 30번 크기까지 근관을 형성하고 근관형성 전후의 근관작업장 및 만곡도의 변화를 관찰하였다. 근단공에 대한 10-K파일 끝의 위치변화를 AutoCAD2000 (Autodesk 사, 미국)으로 측정하고 일원변량분석법 및 Tukey's studentized range test로 통계 분석하였다. 모든 군에서 근관형성후 근관장 및 만곡도가 유의하게 감소하였으며, 치관부 근관형성시 Gates Glidden bur를 사용한 수동파일 군이 ProFile 군보다 유의하게 많은 근관장 감소를 초래하였고, 치관부 및 근단부 전체 근관형성후에는 스테인레스 스틸 수동파일 군이 ProFile 군에서보다 유의하게 많은 근관장 감소를 나타내었다 (p<0.05).

Keywords

References

  1. Shilder H. Cleaning and shaping the root canal. Dent Clin North Am 18:269-296, 1974
  2. Weine FS, Kelly RF, Lio PJ. The effect of preparation procedures on original canal shape and on apical foramen shape. J Endod 1:255-262, 1975 https://doi.org/10.1016/S0099-2399(75)80037-9
  3. Alodeh MH, Doller R, Dummer PN. Shaping of simulated root canals in resin blocks using the step-back technique with K-files manipulated in a simple in/out filing motion. Int Endod J 22:107-117, 1989 https://doi.org/10.1111/j.1365-2591.1989.tb00908.x
  4. Abou-Rass M, Frank AL, Glick DH. The anticurvature filing method to prepare the curved root canal. J Am Dent Assoc 101:792-794, 1980 https://doi.org/10.14219/jada.archive.1980.0427
  5. Morgan LF and Mongomery S. An evaluation of the crown-down pressureless technique. J Endod 10:491-498, 1984 https://doi.org/10.1016/S0099-2399(84)80207-1
  6. Roane JB, Sabala CL, Duncanson MG. The 'balance force' concept for instrumentation of curved canals. J Endod 11:203-211, 1985 https://doi.org/10.1016/S0099-2399(85)80061-3
  7. Esposito PH, Cunningham CJ. A comparison of canal preparation with nickel-titanium and stainless steel instrument. J Endod 21:173-176, 1995 https://doi.org/10.1016/S0099-2399(06)80560-1
  8. Walia H, Brantley WA, Gerstein H. An initial investigation of the bending and torsional properties of nitinol root canal files. J Endod 14:346-357, 1988 https://doi.org/10.1016/S0099-2399(88)80196-1
  9. Dagher FE, Yared GM. Comparison of three files to prepare curved root canal. J Endod 21:264-265, 1995 https://doi.org/10.1016/S0099-2399(06)80994-5
  10. Glosson CR, Haller RH, Dove SB, Rio CE. A comparison of root canal preparation using Ni-Ti hand, Ni-Ti engine-driven, and K-flex endodontic instruments. J Endod 21:146-151, 1995 https://doi.org/10.1016/S0099-2399(06)80441-3
  11. Hur YJ, Kim SK. Change in root canal configuration using different file types and techniques. J Kor Acad Conserv Dent 22:291-304, 1997
  12. Schneider SW. A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol 32:271-275, 1971 https://doi.org/10.1016/0030-4220(71)90230-1
  13. Caldwell JL. Change on working length following instrumentation of molar canals. Oral Surg Oral Med Oral Pathal 41:114-8, 1976 https://doi.org/10.1016/0030-4220(76)90260-7
  14. Faber JP, Bernstein M. The effect of instrumentation on root canal length as measured with an electronic device. J Endod 9:114-115, 1983 https://doi.org/10.1016/S0099-2399(83)80108-3
  15. Kim BH, Kim YS, Lee YK. Working length change by instrumentation according to the canal curvature. J Kor Acad Conserv Dent 24:623-627, 1999
  16. Schroeder KP, Walton RE, Rivera EM. Straight line access and coronal flaring: Effect on canal length. J Endod 28:474-476, 2002 https://doi.org/10.1097/00004770-200206000-00015
  17. Davis RD, Marshall JG, Baumgartner JC. Effect of early coronal flaring on working length change in curved canals using rotary nickel-titanium versus stainless steel instruments. J Endod 28:438-442, 2002 https://doi.org/10.1097/00004770-200206000-00005
  18. Thompson SA, Dummer PM. Shaping ability of Profile 04 taper series 29 rotary nickel-titanium instruments in simulated root canals: Part 1. Int Endod J 30:1-7, 1997 https://doi.org/10.1111/j.1365-2591.1997.tb01093.x
  19. Thompson SA, Dummer PM. Shaping ability of Hero 642 rotary nickel-titanium instruments in simulated root canals: Part 1. Int Endod J 33:248-254, 2000 https://doi.org/10.1046/j.1365-2591.2000.00287.x
  20. Bryant ST, Dummer PM, Pitoni C, Bourba M, Moghal S. Shaping ability of .04 and .06 taper Profile rotary nickel-titanium instruments in simulated root canals. Int Endod J 32:155-164, 1999 https://doi.org/10.1046/j.1365-2591.1999.00256.x
  21. Bryant ST, Thompson SA, AI-Omari MA, Dummer PM. Shaping ability of Profile rotary nickel-titanium instruments with ISO sized tips in simulated root canals: Part 1. Int Endod J 31:275-281, 1998 https://doi.org/10.1046/j.1365-2591.1998.00153.x
  22. Kum KY, Spangberg L, Cha BY, Jung IY, Lee Sj, Lee CY. Shaping ability of three Profile rotary instrumentation techniques in simulated resin root canals. J Endod 26:719-723, 2000 https://doi.org/10.1097/00004770-200012000-00013
  23. Arens DE, Senia SE, Johnson B, McSpadden J. The crown-down technique: a paradigm shift. interviewed by Donald E. Arens. Dent Today 15:38-47, 1996
  24. Yun HH and Kim SK. A comparison of the shaping abilities of four rotary nickel-titanium instruments in simulated root canals. Oral Surg Oral Med Oral Pathol Endodont Dent Radiol 95:228-233, 2003 https://doi.org/10.1067/moe.2003.92
  25. Seok-Dong Choi, Myung-Uk Jin, Ki-Ok Kim, Sung Kyo Kim. Shaping ability of four rotary nickel-titanium instruments to prepare root canal at danger zone. J Kor Acad Cons Dent 29(5):446-453, 2004 https://doi.org/10.5395/JKACD.2004.29.5.446

Cited by

  1. Study of endodontic working length of Korean posterior teeth vol.35, pp.6, 2010, https://doi.org/10.5395/JKACD.2010.35.6.429