• Title/Summary/Keyword: Working length

Search Result 571, Processing Time 0.02 seconds

Comparison of apical transportation and change of working length in K3, NRT AND PROFILE rotary instruments using transparent resin block (Transparent resin block을 이용한 K3, NRT, PROFILE의 apical transportation 및 working length 변화양상의 비교)

  • Yoon, Min-Jung;Song, Min-Ju;Shin, Su-Jung;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.1
    • /
    • pp.59-65
    • /
    • 2011
  • Objectives: The purpose of this study is to compare the apical transportation and working length change in curved root canals created in resin blocks, using 3 geometrically different types of Ni-Ti files, K3, NRT, and Profile. Materials and Methods: The curvature of 30 resin blocks was measured by Schneider technique and each groups of Ni-Ti files were allocated with 10 resin blocks at random. The canals were shaped with Ni-Ti files by Crown-down technique. It was analyzed by Double radiograph superimposition method (Backman CA 1992), and for the accuracy and consistency, specially designed jig, digital X-ray, and CAD/CAM software for measurement of apical transportation were used. The amount of apical transportation was measured at 0, 1, 3, 5 mm from 'apical foramen - 0.5 mm' area, and the alteration of the working length before and after canal shaping was also measured. For statistics, Kruskal-Wallis One Way Analysis was used. Results: There was no significant difference between the groups in the amount of working length change and apical transportation at 0, 1, and 3 mm area (p = 0.027), however, the amount of apical transportation at 5 mm area showed significant difference between K3 and Profile system (p = 0.924). Conclusions: As a result of this study, the 3 geometrically different Ni-Ti files showed no significant difference in apical transportation and working length change and maintained the original root canal shape.

A STUDY ON THE ACCURACY OF THE ROOT-ZX ACCORDING TO THE VARIOUS CONDITIONS OF ROOT CANALS (근관내 여러 가지 조건에 따른 Root-ZX의 정확도에 관한 연구)

  • Hwang, Ho-Keel;Shin, Young-Guen;Kim, Pyung-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.474-482
    • /
    • 2000
  • Currently frequency-dependent type electronic apex locators have been widely used to determine the working length in endodontic treatment. But, accuracy of electronic apex locators is controversial. The purpose of this study was to evaluate the accuracy of Root-ZX(Morita Co., Japan) at different kinds of conditions of root canals compared with the radiographic working length. The 40 extracted human anterior teeth with fully formed apices and without any caries were used. The radiographs were taken for working length with the 0.5mm short of #15 K-file tip just visible at the foramen under the surgical microscope(Carl Zeiss Co. Germany) at 25X. Then the electronic working lengths were determined with Root-ZX at the different kinds of conditions of root canals according to the presence of electrolyte and Crown-down pressureless technique. The results were as follows ; 1. There was no significant statistical difference in working length between radiograph and Root-ZX. 2. There was no significant statistical difference in electronic working length between the canal with electrolyte and without electrolyte. 3. There was no significant statistical difference in electronic working length between the canal without any instrumentation and after Crown-dow pressureless technique. 4. Of the total 40 root canals, 85% in Group I, 92.5% in Group II, 95% in Group III and 95% in Group IV using Root-ZX showed coincidence within 0.5mm accuracy compaing with the radiographic working length. The results showed that the Root-ZX can be use effectively for measuring the working length of root canal after instrumentation with Crown-down pressureless technique regardless of the presence of electrolyte in root canal.

  • PDF

A COMPARISON OF THE LENGTH BETWEEN MESIO-BUCCAL AND MESIO-LINGUAL CANALS OF THE MANDIBULAR MOLAR (하악대구치 근심치근의 협설측 근관장의 비교)

  • Park Seul-Hee;Noh Bong-Hwan;Hwang Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.6
    • /
    • pp.541-547
    • /
    • 2004
  • The aim of this study was to compare the initial apical file (IAF) length between the mesio-buccanl and mesio-lingual canals of the mandibular molar before and after early coronal flaring. Fifty mandibular molars with complete apical formation and patent foramens were selected. After establishing the initial working length of the buccal and lingual canal of the mesial root using the Root-ZX, radiographs were taken for the working length with a 0.5 mm short of #15 K-file tip just visible at the foramen under a surgical microscope (OPMI 1-FC, Carl Zeiss Co. Germany) at 25X. After early coronal flaring using the $K^3$ file, additional radiographs were taken using the same procedure. The root canal morphology and the difference in working length between the buccal and lingual canals were evaluated. These results show that the difference in the length between the mesio-buccal and mesio-lingual canals of the mandibular molar was $\leq$ 0.5 mm. If one canal has a correct working length for the mesial root of the mandibular molar, it can be used effectively for measuring the working length of another canal when the files are superimposed or loosening. In addition, the measured the working length after early coronal flaring is much more reasonable because the difference in the length between the mesio-buccal and mesio-lingual canals can be reduced.

WORKING LENGTH CHANGE BY INSTRUMENTATION ACCORDING TO THE CANAL CURVATURE (만곡근관에서 근관형성에 따른 작업장 변화에 관한 연구)

  • Kim, Byung-Hyun;Kim, Young-Sik;Lee, Young-Kyoo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.623-627
    • /
    • 1999
  • During canal instrumentation of a curved canal, restoring force of endodontic instrument remove more dentin from the inner wall of the curvature. This effect tends to straighten the canal and thus may significantly shorten the working length. This study was to determine the mean reduction in working length after instrumentation according to the curvature. The curvature of mandibular mesial root was determined before instrumentation. 30 canals were divided into 3 groups each 10 on the basis of degree of curvature. Experimental groups as follows. In group 1, canals having curvature from 15 to 20 degrees: in group 2, canals having curvature from 20 to 30degrees; in group 3, canals having curvature above 30 degrees. Experimental teeth in all groups were accessed, and their actual working length determined by passing a size 15 K-file(IAF) just through the minor apical foramen. The canals were sequentially enlarged to size 35 with ProFile .06 series. The change of working length was calculated by measuring the tip of IAF beyond apical foramen by using stereomicroscope. The change of canal curvature following instrumentation were measured using the Schneider technique. The results were as follows. 1. The greatest changes of curvature and working length were observed in the group 3 canals(P<0.05), next were group 2 canals and group 1 canals(P>0.05). 2. Group 1 canals showed a mean reduction in 1.61 degrees and length of 0.12m respectively(P>0.05). 3. Group 2 canals showed a mean reduction in 3.42 degrees(P<0.05) and length of 0.25mm(P>0.05) respectively. 4. Group 3 canals showed a mean reduction in 7.23 degrees(<0.05) and length of 0.64mm respectively(P<0.05).

  • PDF

Change of working length in curved canals by various instrumentation techniques (만곡근관에서 근관형성법에 따른 근관작업장의 변화)

  • Jo, Jeong-Im;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.30-35
    • /
    • 2006
  • To evaluate the change of working length with various instrumentation techniques in curved canals, working length and canal curvature were determined before and after canal instrumentation in buccal or mesial canals of extracted human molars. Stainless steel K-files ($MANI^{(R)}$, Matsutani Seisakusho Co. Takanezawa, Japan), nickel-titanium K-files (Naviflex $NT^{TM}$, Brassier, Savannah, USA) , $ProFile^{(R)}$, and ProTaper (Dentsply-Maillefer, Ballaigues, Switzerland) were used to prepare the canals with crown-down technique. In two hand instrumentation groups coronal flaring was made with Gates Glidden burs. Apical canals were instrumented until apical diameter had attained a size of 30. Positional relation between the tooth apex and the $\#10$ K-file tip was examined by using AutoCAD 2000 (Autodesk Corp., San Rafael. CA, USA) under a stereomicroscope before and after coronal flaring, and after apical instrumentation. Degree of canal curvature was also measured with Schneider's method in radiographs. Data of working length and canal curvature changes were statistically analyzed with one-way ANOVA and Tukey's studentized range test. Working length and canal curvature were decreased significantly in each step in all instrumentation groups. Coronal flaring using Cates Glidden burs in hand instrument groups and whole canal instrumentation using stainless steel hand K-files caused significantly more working length change than in ProFile instrumentation group (p<0.05). The result of this study demonstrates that all of the above kinds of instrumentation in curved canals cause reduction of working length and canal curvature at each instrumentation steps, and hand instrumentation causes more working length change than ProFile.

Influence of glide path size and operating kinetics on time to reach working length and fracture resistance of Twisted File adaptive and Endostar E3 nickel-titanium file systems

  • Ramyadharshini, Tamilkumaran;Sherwood, Inbaraj Anand;Vigneshwar, V Shanmugham;Prince, Prakasam Ernest;Vaanjay, Murugadoss
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.2
    • /
    • pp.22.1-22.10
    • /
    • 2020
  • Objectives: This study investigated the influence of glide path size and operating kinetics on the time to reach the working length and the fracture resistance of Twisted File (TF) and Endostar E3 files. Materials and Methods: A total of 120 mandibular single-rooted premolars were selected. Two methods of kinetic motion (TF adaptive and continuous rotary motion) and file systems (TF and Endostar E3) were employed. The files were used in root canals prepared to apical glide path sizes of 15, 20, and 25. The time taken to reach the working length and the number of canals used before the instrument deformed or fractured were noted. Fractured instruments were examined with scanning electron microscopy. Results: The TF system took significantly more time to reach the working length than the Endostar E3 system. Both systems required significantly more time to reach the working length at the size 15 glide path than at sizes 20 and 25. A greater number of TFs than Endostar E3 files exhibited deformation, and a higher incidence of instrument deformation was observed in adaptive than in continuous rotary motion; more deformation was also observed with the size 15 glide path. One TF was fractured while undergoing adaptive motion. Conclusions: No significant difference was observed between continuous rotary and adaptive motion. The TF system and adaptive motion were associated with a higher incidence of deformation and fracture. Apical glide path sizes of 20 and 25 required significantly less time to reach the working length than size 15.

Effect of repetitive pecking at working length for glide path preparation using G-file

  • Ha, Jung-Hong;Jeon, Hyo-Jin;Abed, Rashid El;Chang, Seok-Woo;Kim, Sung-Kyo;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.2
    • /
    • pp.123-127
    • /
    • 2015
  • Objectives: Glide path preparation is recommended to reduce torsional failure of nickel-titanium (NiTi) rotary instruments and to prevent root canal transportation. This study evaluated whether the repetitive insertions of G-files to the working length maintain the apical size as well as provide sufficient lumen as a glide path for subsequent instrumentation. Materials and Methods: The G-file system (Micro-Mega) composed of G1 and G2 files for glide path preparation was used with the J-shaped, simulated resin canals. After inserting a G1 file twice, a G2 file was inserted to the working length 1, 4, 7, or 10 times for four each experimental group, respectively (n = 10). Then the canals were cleaned by copious irrigation, and lubricated with a separating gel medium. Canal replicas were made using silicone impression material, and the diameter of the replicas was measured at working length (D0) and 1 mm level (D1) under a scanning electron microscope. Data was analysed by one-way ANOVA and post-hoc tests (p = 0.05). Results: The diameter at D0 level did not show any significant difference between the 1, 2, 4, and 10 times of repetitive pecking insertions of G2 files at working length. However, 10 times of pecking motion with G2 file resulted in significantly larger canal diameter at D1 (p < 0.05). Conclusions: Under the limitations of this study, the repetitive insertion of a G2 file up to 10 times at working length created an adequate lumen for subsequent apical shaping with other rotary files bigger than International Organization for Standardization (ISO) size 20, without apical transportation at D0 level.

Study of endodontic working length of Korean posterior teeth (한국인의 구치부 근관작업장에 관한 연구)

  • Kim, Jeong-Yeob;Lee, Sang-Hoon;Lee, Gwang-Hee;Park, Sang-Hyuk
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.429-435
    • /
    • 2010
  • Objectives: The aim of this study was to investigate average working lengths of Korean posterior teeth and evaluate validity of endodontic file length. Materials and Methods: The endodontic working length of the posterior teeth of 670 Korean patients were measured than each mean value and standard deviation were investigated than the frequency deviation and standard deviation per each length were calculated. Results: Among the canals of premolar, 66.5% of canal length was marked under 20 mm by endodontic working length and 95.4% could be measured under 22 mm and Among the canals of molars, 95.5% of canal length was marked under 20 mm endodontic working length. Conclusions: With the result of measurement of endodontic working length of premolars of Korean, it suggested that 23 mm endodontic file is more proper than the 21 mm and 25 mm file on the market.

A survey on working length determination of endodontic treatment (근관치료의 근관장 측정에 관한 연구: 근관치료학 전공 교수 설문)

  • Ahn, Hye-ra;Seo, Min-Seock
    • The Journal of the Korean dental association
    • /
    • v.55 no.1
    • /
    • pp.42-52
    • /
    • 2017
  • The purpose of this study is to evaluate the preferred method of root canal length determination and the apical limit for canal instrumentation among endodontic teachers of dental school. A questionnaire on the preferred method of root canal length determination and the apical limit for canal instrumentation was designed and distributed to endodontic teachers of various dental schools. The response rate was 90%. The most preferred method of root canal length determination was Electronic apex locator (EAL)(89%). The most favoured apical limit for canal instrumentation was 0.5 to 1.0 mm short of the radiographic apex(78%). The most preferred method of using EAL was that the working length is taken at 'APEX' mark and then distracted 0.5mm from that length.(41%). When there is no agreement between radiographic measurement and EAL measurement, 74% of respondents chose the length of EAL measurement. The majority of endodontic teachers from Korean dental schools preferred EAL to radiograph method in determining root canal length.

  • PDF

Threshing Performance dependent upon Feed Rate and Threshing Drum Length for Head-Feed Combine (공급률 및 탈곡통 길이 변화에 따른 자탈형 콤바인 탈곡 성능)

  • Seo, Sin-Won;Lee, Sang-Woo;Huh, Yun-Kun
    • Korean Journal of Agricultural Science
    • /
    • v.33 no.2
    • /
    • pp.159-166
    • /
    • 2006
  • Threshing loss was increased due to dropping of the threshing efficiency when the 4 row head-feed combine harvested 5 row rice to improve harvesting performance of a combine. Reasonable design criteria were examined to determine the ranges of both of feed rate and the length of threshing drum for the 4 row head-feed combine being used as a 5-row combine. Harvesting performance increased as working width or working speed increased, it resulted in 15% increase when the working width increased from 4 row to 5 row. Harvesting operations of the 4 row combine performed normally in the 4 row rice in threshing loss less than 1%, however, threshing loss increased to 2.25% in the 5 row due to poor threshing efficiency. The length of threshing drum was increased from 710 mm to 810 mm as well as the speed of crop feed chain was increased from 0.61 m/s to 0.75 m/s so as to improve the poor threshing efficiency resulted from the enlarged working width from the 4 row to the 5 row, which would decrease threshing loss less than 1%.

  • PDF