• 제목/요약/키워드: Conventional zirconia

검색결과 99건 처리시간 0.028초

마이크로파에 의한 바이오디젤 합성의 가속화와 에너지 효율성 (Microwave-enhanced Acceleration and Energy-efficiency of Biodiesel Synthesis)

  • 김대호;정순신;설승권
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.108.2-108.2
    • /
    • 2011
  • This presentation shows energy-efficiency of microwave-accelerated esterification of free fatty acid with a heterogeneous catalyst by net microwave power measurement. In the reaction condition of 5wt% sulfated zirconia and 1:20 molar ratio of oil to methanol at $60^{\circ}C$ and atmospheric pressure, more than 90% conversion of the esterification was achieved in 20 minutes by microwave heating, while it took about 130 minutes by conventional heating. Electric energy consumption for the microwave heating in this accelerated esterification was only 67% of estimated minimum heat energy demand because of significantly reduced reaction time.

  • PDF

니켈-크롬 합금에 대한 다용도 접착 시스템의 전단결합강도 (Shear bond strength of Universal bonding systems to Ni-Cr alloy)

  • 송소연;손병화;김종엽;신상완;이정열
    • 대한치과보철학회지
    • /
    • 제53권4호
    • /
    • pp.295-300
    • /
    • 2015
  • 목적: 레진과 니켈-크롬 합금의 결합력에 미치는 금속 프라이머 및 다용도 접착제의 영향에 대하여 비교 평가하고자 한다. 재료 및 방법: 실험을 위해 120개의 니켈-크롬 합금(Vera Bond 2V) 디스크를 제작하여 아크릴 레진 실린더에 포매하였다. 시편의 표면은 220 grit, 600 grit의 실리콘 카바이드지로 연마한 뒤 $50{\mu}m$의 알루미늄옥사이드 입자를 분사하여 처리하였다. 실험군은 메탈 프라이머의 적용(Metal primer II, Alloy primer, Metal & Zirconia primer, MKZ primer)과 다용도 접착 시스템(Single Bond Universal, All Bond Universal)에 따라 6개 군으로 나뉘었다. 각 시편의 중앙에 높이 2 mm, 직경 3 mm로 복합레진을 충전하였으며, 제작된 모든 시편은 $37^{\circ}C$ 증류수에서 24시간 보관하였다. 만능시험기에 시편을 위치시킨 후 1 mm/min cross head speed로 전단결합강도를 측정하였다. 통계분석은0.05의 유의수준으로 일원분산분석을 시행하였고 Tukey's multiple coMParison test로 사후검정을 하였다. 결과: Single Bond Universal, All Bond Universal, Metal Primer II 3개 군과 Alloy Primer, MKZ Primer, Metal & Zirconia Primer 3개 군 사이에 통계학적으로 유의한 차이를 보였다(P<.001). 결론: 니켈-크롬 합금에 대한 다용도 접착 시스템의 전단결합강도는 Metal Primer II를 제외한 기존의 금속 프라이머를 적용했을 때 보다 높게 나타났다. 본 실험에서 더 나아가 다용도 접착 시스템 내 실란(Silane) 포함 여부에 따른 효과를 평가할 수 있는 연구가 필요할 것이다.

수종의 CAD/CAM 시스템으로 제작한 지르코니아 기반 완전도재관의 적합도 비교 (A comparison of the fidelity of various zirconia-based all-ceramic crowns fabricated with CAD/CAM systems)

  • 김성준;조광헌;이규복
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.148-155
    • /
    • 2009
  • 연구목적: 최근에는 금속도재관의 심미적 문제로 심미성과 강도가 개선된 코아용 도재 및 지르코니아를 이용한 전부도재관 시스템에 관심이 증가되고 있다. 특히 금속과 유사한 강도를 가지면서 금속의 비심미성을 극복할 수 있는 지르코니아를 이용한 보철물의 제작이 국내외에서 많이 이뤄지고 있다. 하지만 CAD/CAM 시스템으로 제작되는 여러 종류의 지르코니아를 이용한 전부도재관의 적합도에 대한 임상 연구는 부족한 실정이다. 다양한 CAD/CAM 시스템 중 Procera, Cerec inLab, Lava에 의해 제작된 지르코니아를 이용한 전부도재관의 변연 적합도와 내면 적합도를 측정하여 이를 전통적인 방식으로 주조된 금속 도재관의 적합도와 비교 평가해 봄으로써 임상 적용에 참고 자료로 활용하고자 한다. 연구 재료 및 방법: 본 연구를 위해 하악 우측 제2소구치에 해당하는 레진치를 삭제하여 인상채득 후, 금속 주모형을 제작하였다. 금속 주모형의 40개의 인상을 채득 후 각 시스템마다 10개씩 총 40개의 crown을 제작하였다. 금속도재관은 전통적인 방식으로 제작하였고 Procera, Lava, Cerec inLab crown은 zirconia core를 이용하여 CAD/CAM 시스템으로 제작하였다. 수직 변연 오차와 내면 간격을 각 그룹마다 금속 주모형에 시멘트 접착 없이 측정하였다. 그 결과는 oneway ANOVA와 Tukey's HSD test로 통계 내었다. 결과: 수직 변연 오차는 금속도재관이 $50.6{\pm}13.9{\mu}m$, Procera crown이 $62.3{\pm}15.7{\mu}m$, Lava crown이 $45.3{\pm}7.9{\mu}m$, Cerec inLab crown은 $71.2{\pm}2.0{\mu}m$로 측정되었다. 내면 간격은 금속도재관이 $52.6{\pm}10.1{\mu}m$, Procera crown이$161.7{\pm}18.5{\mu}m$, Lava crown이 $63.0{\pm}10.2{\mu}m$, Cerec inLab crown이 $73.7{\pm}10.7{\mu}m$로 측정되었다. 변연 적합도 측면에서 볼 때 Procera crown, Lava crown, Cerec inLab 그리고 전통적인 금속도재관은 임상적으로 받아들일 수 있는 적합도 범위($120{\mu}m$) 내에 있었다. 내면 적합도 측면에서 볼 때 Procera crown을 제외한 Lava crown, Cerec inLab, 금속도재관은 임상적으로 받아들일 수 있는 적합도 범위($140{\mu}m$) 내에 있었다.

Ti-Al-Si-N 코팅막의 마모거동에 미치는 Si 함량의 영향 (The Effect of Si Content on the Tribological Behaviors of Ti-Al-Si-N Coating Layers)

  • 진형호;김정욱;김광호;윤석영
    • 한국세라믹학회지
    • /
    • 제42권2호
    • /
    • pp.88-93
    • /
    • 2005
  • 아크 이온 플레이팅과 스퍼터로 구성된 하이브리드 시스템을 이용하여 다성분계 Ti-Al-Si-N 코팅막을 WC-Co 기판에 증착하였다. 증착시 Si 함량을 변화시켜 코팅막의 마모특성에 Si 함량이 미치는 영향에 대하여 조사하였다. 마모 특성을 관찰하기 위하여 Ti-Al-Si-N 코팅막이 증착된 WC-Co 원판에 3N의 하중, 0.1 m/s의 속도로 볼 온 디스크(ball-on-disk) 형태의 마모시험기를 이용하여 건식 마모 실험을 하였다. 상대재로는 스틸볼과 지르코니아볼을 사용하였다. 상대재가 스틸볼의 경우 Ti-Al-Si-N 코팅막의 마찰계수가 Ti-Al-N 코팅막의 마찰계수보다 낮게 나타났다 이는 Si가 첨가되어 마모시 상대재와 코팅막 사이에 자기윤활효과(self-lubricant effect)에 의한 것으로 여겨진다. 코팅막과 스틸볼 사이에 응착 마모 거동을 보였으며, Si의 함량이 증가함에 따라 마찰계수는 감소하였다. 한편, 상대재가 지르코니아 볼의 경우 코팅막과 지르코니아 볼 사이에서 연삭마모 거동이 더 지배적이었고, Si 함량이 증가할수록 마찰계수는 증가하였다.

다용도 프라이머가 레진 시멘트와 수복재의 전단 결합 강도에 미치는 영향 (Effect of universal primer on shear bond strength between resin cement and restorative materials)

  • 김나홍;심준성;문홍석;이근우
    • 대한치과보철학회지
    • /
    • 제50권2호
    • /
    • pp.112-118
    • /
    • 2012
  • 연구 목적: 이 연구의 목적은 실란과 인산 모노머를 혼합한 프라이머인 Monobond plus (Ivoclar Vivadent, Schaan, Liechtenstein)를 사용했을 때 레진 시멘트와 수복물 간의 전단 결합 강도가 귀금속, 비귀금속, 글라스 세라믹과 지르코니아 네 가지 재료 모두에서 기존의 프라이머를 사용했을 때의 결합 강도와 비교하여 유의한지 평가하는 것이다. 연구 재료 및 방법: 디스크 모양(${\phi}\;9mm{\times}3mm$)의 귀금속(Argedent Euro) 시편 16개, 비귀금속(T-4) 시편 20개, 지르코니아(Cercon) 시편 20개, 글라스 세라믹(IPS e.max press) 시편 20개를 제작한 후 아크릴릭 레진(${\phi}\;15mm{\times}15mm$)에 포매하였다. 귀금속 시편에 airborne-particle abrasion을 시행하고 대조군으로 사용한 8개 시편에는 귀금속용 프라이머(Metal primer II)를, 나머지 8개 시편에는 Monobond plus를 도포하였다. 비귀금속 시편과 지르코니아 시편은 airborne-particle abrasion 후 각각 두 그룹으로 나누어 대조군 10개 시편에는 비귀금속 및 지르코니아용 프라이머(Alloy primer)를, 나머지 10개에는 Monobond plus를 도포하였다. 글라스 세라믹 시편은 4% 불산으로 부식한 후, 대조군 10개 시편에는 실란(Monobond-S)을, 나머지 10개에는 Monobond plus를 적용했다. 표면 처리된 시편 위에 디스크 형태(${\phi}\;5mm{\times}2mm$)로 레진 시멘트(Multilink N)를 위치시키고 중합하였다. 제작된 모든 시편을 열순환($5^{\circ}C$$55^{\circ}C$, 1분씩 2060회)시킨 후 전단 결합 강도를 측정하였다. 전단 결합 강도의 유의차를 살펴보기 위해 Shapiro-Wilk test를 이용하여 모집단의 분포에 대한 검정을 하고 그 결과에 따라 Two sample $t$-test 또는 Mann-Whitney U test를 실시하였다(${\alpha}$=.05). 파절된 시편을 확대경으로 관찰하여 그 양상을 분류하였다. 결과: 귀금속과 글라스 세라믹 군에서는 두 프라이머간의 전단 결합 강도에 유의한 차이가 존재하지 않았으나($P$>.05) 비귀금속 군과 지르코니아 군에서는 기존 프라이머(Alloy primer)를 사용했을 때 레진 시멘트와 수복물간의 전단 결합 강도가 Monobond plus를 사용한 군보다 통계적으로 유의하게 높았다(비귀금속 군$P$=.004, 지르코니아 군$P$=.001). 결론: 실란과 인산 모노머를 혼합한 다용도 프라이머는 귀금속과 글라스 세라믹 군에서는 기존의 프라이머를 대신하여 사용할 수 있을 것이다. 그러나 비귀금속과 지르코니아 세라믹에서는 10-MDP 프라이머에 비해 접착 강도가 낮아 기존 프라이머를 대신하여 적용하기 위해서는 좀 더 연구가 필요할 것이다.

Evaluation of the color reproducibility of all-ceramic restorations fabricated by the digital veneering method

  • Kim, Jae-Hong;Kim, Ki-Baek;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권2호
    • /
    • pp.71-78
    • /
    • 2014
  • PURPOSE. The objective of this study was to evaluate the clinical acceptability of all-ceramic crowns fabricated by the digital veneering method vis-$\grave{a}$-vis the traditional method. MATERIALS AND METHODS. Zirconia specimens manufactures by two different manufacturing method, conventional vs digital veneering, with three different thickness (0.3 mm, 0.5 mm, 0.7 mm) were prepared for analysis. Color measurement was performed using a spectrophotometer for the prepared specimens. The differences in shade in relation to the build-up method were calculated by quantifying ${\Delta}E^*$ (mean color difference), with the use of color difference equations representing the distance from the measured values $L^*$, $a^*$, and $b^*$, to the three-dimensional space of two colors. Two-way analysis of variance (ANOVA) combined with a Tukey multiple-range test was used to analyze the data (${\alpha}$=0.05). RESULTS. In comparing means and standard deviations of $L^*$, $a^*$*, and $b^*$ color values there was no significant difference by the manufacturing method and zirconia core thickness according to a two-way ANOVA. The color differences between two manufacturing methods were in a clinically acceptable range less than or equal to 3.7 in all the specimens. CONCLUSION. Based on the results of this study, a carefully consideration is necessary while selecting upper porcelain materials, even if it is performed on a small scale. However, because the color reproducibility of the digital veneering system was within the clinically acceptable range when comparing with conventional layering system, it was possible to estimate the possibility of successful aesthetic prostheses in the latest technology.

플라즈마 용사법에 의한 금속면에 세라믹 코팅된 표면과 범용고분자와의 접착특성 (Adhesion Characteristics of Polymers and Ceramic Surface Coated on Metal by Plasma Spray)

  • 이경희;권순훈;조원제;하창식
    • 한국재료학회지
    • /
    • 제9권7호
    • /
    • pp.724-734
    • /
    • 1999
  • 본 연구는 플라즈마 용사법에 의해 일반구조용 강재 (SS41, 30$\times$40$\times$60mm$^{t}$ )와 연마제로 블래스팅을 실시한 강재 (SS41P) 및 SS41P에 세라믹 분말을 코팅한 강재 (SS41PC)에 대한 SEM, 표면경도. 표면거칠기. 접촉각을 측정하였으며 이들의 표면형태에 대한 기계적 .물리적 특성을 고찰하였다 사용한 세라믹 용사분말은 \circled1 $Al_2$O$_3$ : alumina \circled2 $Al_2$O$_3$ 95%, TiO$_2$ 5% : alumina titania \circled3 ZrO$_2$: 95%, $Y_2$O$_3$5% : zirconia yttria이었다. 또한 SS41, SS41P. SS41PC에 대해 범용 고분자인 PE, PVC, PP PET, PS를 접착시킨 후 이들의 표면접착특성을 조사하였다. 그 결과 인장전단강도와 박리강도의 특성에서 SS41보다는 SS41P와 SS41PC의 표면상태가 고분자들을 접착시켰을 때 더 우수한 접착강도특성을 나타내었다. 범용 고분자들의 접착강도는 PE > PET > PP > PS > PVC 순이었다. 그리고 세라믹 표면과 고분자의 접착특성은 세라믹 표면의 표면거칠기 정도와 고분자의 세라믹 표면에 대한 anchor 효과의 크기 순으로 증가하였으며, SS41PC와 PE의 접착강도는 분자표면의 규칙성에 기인된 Synergy효과에 의해서 PVC보다 우수하게 나타난 것으로 판정된다

  • PDF

Halogen Light Curing Unit과 Light Emitting Diodes Curing Unit을 이용하여 중합되어진 복합레진의 마멸 특성 비교 (Wear of Resin Composites Polymerized by Conventional Halogen Light Curing and Light Emitting Diodes Curing Units)

  • 이권용;김환;박성호;정일영;전승범
    • Tribology and Lubricants
    • /
    • 제21권6호
    • /
    • pp.268-271
    • /
    • 2005
  • In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15N contact force in a reciprocal sliding motion of sliding distance of 10mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji II LC specimen was the greatest among all resin composites. Dyract AP showed less wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as curing unit for composite resin restorations.

Direct Microwave Sintering of Poorly Coupled Ceramics in Electrochemical Devices

  • Amiri, Taghi;Etsell, Thomas H.;Sarkar, Partha
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권3호
    • /
    • pp.390-397
    • /
    • 2022
  • The use of microwaves as the energy source for synthesis and sintering of ceramics offers substantial advantages compared to conventional gas-fired and electric resistance furnaces. Benefits include much shorter processing times and reaching the sintering temperature more quickly, resulting in superior final product quality. Most oxide ceramics poorly interact with microwave irradiation at low temperatures; thus, a more complex setup including a susceptor is needed, which makes the whole process very complicated. This investigation pursued a new approach, which enabled us to use microwave irradiation directly in poorly coupled oxides. In many solid-state electrochemical devices, the support is either metal or can be reduced to metal. Metal powders in the support can act as an internal susceptor and heat the entire cell. Then sufficient interaction of microwave irradiation and ceramic material can occur as the sample temperature increases. This microwave heating and exothermic reaction of oxidation of the support can sinter the ceramic very efficiently without any external susceptor. In this study, yttria stabilized zirconia (YSZ) and a Ni-YSZ cermet support were used as an example. The cermet was used as the support, and a YSZ electrolyte was coated and sintered directly using microwave irradiation without the use of any susceptor. The results were compared to a similar cell prepared using a conventional electric furnace. The leakage test and full cell power measurement results revealed a fully leak-free electrolyte. Scanning electron microscopy and density measurements show that microwave sintered samples have lower open porosity in the electrode support than conventional heat treatment. This technique offers an efficient way to directly use microwave irradiation to sinter thin film ceramics without a susceptor.

MAD/MAM을 이용한 치과용 지르코니아 코어의 변연 적합도 (Marginal fidelity of zirconia core using MAD/MAM system)

  • 강동림;심준성;문홍석;이근우
    • 대한치과보철학회지
    • /
    • 제48권1호
    • /
    • pp.1-7
    • /
    • 2010
  • 연구 목적: 본 연구에서는MAD/MAM 시스템으로 제작된 지르코니아 코어를 통상적인 방법으로 제작된 금속-도재관 코어와 CAD/CAM 시스템으로 제작된 코어와의 변연부 적합도를 비교 분석해 보고자 한다. 연구 재료 및 방법: 레진치를 전부 도재관 제작을 위한 형태로 삭제하고, 이를 복제하여 석고 모형을 제작하였다. 석고 모형에 대해 금속-도재관, CAD/CAM ($Cercon^{(R)}$), 3종의 MAD/MAM 시스템 ($Ceramill^{(R)}$, $Rainbow^{(TM)}$, $Zirkonzhan^{(R)}$)으로 각각 10개의 코어를 제작하였다. 제작된 코어를 다이에 합착하여 광학 현미경 상에서 50배율로 변연 간격을 관찰, 계측하였다. 측정된 결과는 one-way ANOVA test로 분석하고, Tukey's HSD test로 사후검정 하였다. 결과: 각 시스템에서 변연 간격의 평균과 표준 편차는 금속-도재관 코어 $51.97{\pm}23.38{\mu}m$, $Cercon^{(R)}$ $62.16{\pm}25.88{\mu}m$, $Ceramill^{(R)}$ $67.64{\pm}40.38{\mu}m$, $Rainbow^{TM}$ $125.07{\pm}42.19{\mu}m$, $Zirkonzhan^{(R)}$ $105.02{\pm}44.61{\mu}m$로 측정되었다. 결론: 금속-도재관 코어나 CAD/CAM에 비해 MAD/MAM 방식으로 제작된 코어의 변연 간격이 큰 것으로 나타났다 (P < .05). MAD/MAM 시스템 내에서도 $Ceramill^{(R)}$, $Zirkonzhan^{(R)}$, $Rainbow^{TM}$ 순으로 변연 간격이 작은 것으로 측정되었으며, 이중 $Ceramill^{(R)}$은 CAD/CAM 시스템인 $Cercon^{(R)}$과 변연 간격에 유의차가 없었다.