Abstract
Purpose: The purpose of this study was to evaluate the fit of zirconia core using MAD/MAM system comparing to that of conventional metal-ceramic and CAD/CAM system. Materials and methods: Duplicating the prepared resin tooth, 50 improved stone dies were fabricated. These dies are classified as a group of 5 to create the core. The groups were composed of metal-ceramic, $Cercon^{(R)}$, $Ceramill^{(R)}$, $Rainbow^{TM}$, and $Zirkonzhan^{(R)}$. Each core was cemented to stone die, and then, absolute marginal discrepancy was measured with microscope at a magnification of ${\times}50$. Statistical analysis was done with one-way ANOVA test and Tukey's HSD test. Results: The mean absolute marginal discrepancy for metal-ceramic was $51.97{\pm}23.38{\mu}m$, for $Cercon^{(R)}$ was $62.16{\pm}25.88{\mu}m$, for $Ceramill^{(R)}$ was $67.64{\pm}40.38{\mu}m$, for $Rainbow^{TM}$ was $125.07{\pm}42.19{\mu}m$, and for $Zirkonzhan^{(R)}$ was $105{\pm}44.61{\mu}m$. Conclusion: 1. Fit of margin was identified as in the order of metal-ceramic, $Cercon^{(R)}$, $Ceramill^{(R)}$, $Zirkonzhan^{(R)}$, and $Rainbow^{TM}$. 2. Absolute marginal discrepancy of the zirconia core that designed by MAD/MAM system had significant differences in order of $Ceramill^{(R)}$, $Zirkonzhan^{(R)}$, and $Rainbow^{TM}$. 3. The mean absolute marginal discrepancy between $Cercon^{(R)}$ and $Ceramill^{(R)}$ did not show significant differences.
연구 목적: 본 연구에서는MAD/MAM 시스템으로 제작된 지르코니아 코어를 통상적인 방법으로 제작된 금속-도재관 코어와 CAD/CAM 시스템으로 제작된 코어와의 변연부 적합도를 비교 분석해 보고자 한다. 연구 재료 및 방법: 레진치를 전부 도재관 제작을 위한 형태로 삭제하고, 이를 복제하여 석고 모형을 제작하였다. 석고 모형에 대해 금속-도재관, CAD/CAM ($Cercon^{(R)}$), 3종의 MAD/MAM 시스템 ($Ceramill^{(R)}$, $Rainbow^{(TM)}$, $Zirkonzhan^{(R)}$)으로 각각 10개의 코어를 제작하였다. 제작된 코어를 다이에 합착하여 광학 현미경 상에서 50배율로 변연 간격을 관찰, 계측하였다. 측정된 결과는 one-way ANOVA test로 분석하고, Tukey's HSD test로 사후검정 하였다. 결과: 각 시스템에서 변연 간격의 평균과 표준 편차는 금속-도재관 코어 $51.97{\pm}23.38{\mu}m$, $Cercon^{(R)}$ $62.16{\pm}25.88{\mu}m$, $Ceramill^{(R)}$ $67.64{\pm}40.38{\mu}m$, $Rainbow^{TM}$ $125.07{\pm}42.19{\mu}m$, $Zirkonzhan^{(R)}$ $105.02{\pm}44.61{\mu}m$로 측정되었다. 결론: 금속-도재관 코어나 CAD/CAM에 비해 MAD/MAM 방식으로 제작된 코어의 변연 간격이 큰 것으로 나타났다 (P < .05). MAD/MAM 시스템 내에서도 $Ceramill^{(R)}$, $Zirkonzhan^{(R)}$, $Rainbow^{TM}$ 순으로 변연 간격이 작은 것으로 측정되었으며, 이중 $Ceramill^{(R)}$은 CAD/CAM 시스템인 $Cercon^{(R)}$과 변연 간격에 유의차가 없었다.