• Title/Summary/Keyword: Conventional analysis

Search Result 10,091, Processing Time 0.045 seconds

The Results of Radiation Therapy in Stage III Non-Small Cell Lung Cancer (III기 비소세포성 폐암의 방사선치료 성적)

  • Choi, Sang-Gyu;Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.311-319
    • /
    • 1995
  • Purpose : To evaluate the survival and prognostic factors in patients with stage III non-small cell lung cancer treated with curative radiotherapy alone or combined with chemotherapy Materials and Methods : A retrospective analysis was undertaken of 35 patients who had locally advanced non-small-cell lung cancer and treated with curative radiotherapy in Department of Therapeutic Radiology, Kangdong Sacred Heart Hospital, from January 1991 through December 1993. According to AJCC staging, 15 patients were stage IIIA, and 20 were stage IIIB. Radiotherapy was delivered with 1 8-2 Gy per fraction/day. 5 days per week using 6 MV X-ray, to a total dose ranging from 48.8 Gy to 66.6 Gy (median, 61.2 Gy) in 4 to 9 weeks. Ten patients received neoadjuvant or concurrent chemotherapy with FIP (5-FU, ifosfamide, and cisplatin) or FP (5-FU and cisplatin) Results : For all Patients, median survival was 6 months. 1-year and 2-year survival rates were 23.3% and 6.7%, respectively The median survival was 8 months in stage IIIA and 5.5 months in stage IIIB. In patients treated with radiation therapy alone, median survival was 5 months and 1-year survival rate was 9%. In patients who received chemotherapy, median survival was 11 months and 1-year survival rate was 60%. The difference of survival between these two groups was statistically significant (p=0.03). Total radiation dose, degree of response, and Post-treatment ECOG score were also significantly associated with survival. But it was not affected by age, sex, pretreatment ECOG score, presence or absence of weight loss, tumor location. pathologic type, N stage, and degree of response to treatment. Conclusion : Conventional radiotherapy alone is unlikely to achieve long term survival in patients with stage III NSCLC. Radiotherapy with altered fractionation schedule or multimodality treatment combined with surgery and/or chemotherapy should be considered if feasible.

  • PDF

Clinical Study after Video-Assisted Thoracic Surgery and Mid-Axillary Thoracotomy for Recurrent Spontaneous Pneumothorax (재발성 자연 기흉에 대한 정중액과 개흉술과 비디오 흉강경수술의 비교연구)

  • 이정상
    • Journal of Chest Surgery
    • /
    • v.32 no.1
    • /
    • pp.43-48
    • /
    • 1999
  • Background: Although treatment of spontaneous pneumothorax by video-assisted thoracic surgery(VATS) has generally shown better clinical results than conventional thoracotomy, treatment of spontaneous pneumothorax by midaxillary thoracotomy(MAXT) has also shown good clinical results. The author studied to compare the clinical results of MAXT group I and VATS group II. Material and Method : Group I included 30 midaxillary thoracotomy among 83 operative cases of spontaneous pneumothorax from Jan. 1992 to Dec. 1993. Group II included 30 VATS among 101 operative cases of pneumothorax from Jan. 1994 to Aug. 1995. The author selected the 30 patients, age 18 to 25 years, with recurrent spontaneous pneumothorax in each group. The author analyzed the operative indication, gender, operating time, amounts of the used staplers, tube drainage, total amounts of analgesics used during postoperative 24hr, tube stay time, postoperative complications and mortality. Result: The follow-up periods of both procedures were from 6 to 43 months. The operating time from start of skin incision to end of skin closure was 84.79${\pm}$21.70(from 40 to 150) minutes in MAXT group I and 108.8${\pm}$42.02(from 58 to 120) minutes in VATS group II(P<0.001). The numbers of the used staples useo was 1.31${\pm}$0.6(from 0 to 3) in group I and 3.41${\pm}$2.37(from 0 to 11) in group II. The amounts of postoperative 24hour tube drainage were 220.76${\pm}$106.73(from 65 to 400) ml in group I and 260.63${\pm}$233.18(from 70 to 320) in group II(P>0.05). The amounts of postoperative 24 hourly used analgesics(Tarasyn ) was 1.38${\pm}$1.32(from 0 to 5) amples in group I and 0.72${\pm}$1.02(from 0 to 4) amples in group II (P<0.05). The postoperative tube stay is 5.45${\pm}$30.9 (from 3 to 7) days in group I and 4.75${\pm}$3.1(9 from 2 to 14) days in group II(P>0.05). The number of complications after operations was 2 cases of prolonged air leakage in group I, and in group II. (P is not significant). The number of recurrence after the operation was one in group I and also one in group II(P is not significant). In conclusion, there were no statistical differences in the postoperative 24 hour chest tube drainage, days of postoperative tube stay, postoperative complications and recurrence in the analysis between group I and group II. Conclusion: The author found that group II of VATS between 18 years and 25 years of age in recurrent spontaneous pneumothorax, statistically, requires longer operative time, more number of autosuture staples and less postoperative analgesic dosage than the midaxillary thoracotomy group I.

  • PDF

Consideration of Standardized Uptake Value (SUV) According to the Change of Volume Size through the Application of Astonish TF Reconstruction Method (Astonish TF 재구성 기법의 적용을 통한 체적 크기의 변화에 따른 표준섭취계수(SUV)에 관한 고찰)

  • Lee, Juyoung;Nam-Kung, Sik;Kim, Ji-Hyeon;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.115-121
    • /
    • 2014
  • Purpose: In addition to improving the quality of the PET image, through much research, the development of various programs are performed. Astonish TF reconstruction techniques by Philips can confirm the improved contrast of the lesion. Also, It's image reconstruction of 2 mm is possible with rapid reconstruction rate than conventional. In this study, we compared and evaluated Standardized Uptake Value (SUV) in accordance with the 2 mm reconstruction techniques and traditional 4 mm from the $^{18}F-FDG$ PET whole body image. Materials and Methods: In the phantom experiment, NEMA IEC body phantom (sphere: 10, 13, 17, 22, 28, 37 mm) was used to obtain images by using GEMINI TF 64 PET/CT (Philips, Cleveland, USA). Also, In the clinical images, we performed $^{18}F-FDG$ PET/CT examination to 30 women (age: $55.1{\pm}11.3$, BMI: $24.1{\pm}2.9$) with a diagnosis of breast cancer. After that, we reconstructed images in 2 mm and 4 mm respectively. The region of interest was drawn to acquired images. Since then, we measured SUV and statistically analyzed with SPSS ver.18 by using EBW (Extended Brilliance Workstation) NM ver.1.0. Results: After analyzing the result of the phantom study, there was a tendency that the bigger hot sphere size, the higher SUV. If you compared the 2 mm reconstruction techniques to 4 mm, it increased 95.78% in 10 mm, 50.60% in 13 mm, 25.00% in 17 mm, 30.04% in 22 mm, 31.81% in 28 mm, and 27.84% in 37 mm. Through the result of the analysis of the 2 mm reconstruction techniques and 4 mm in clinical images, it appeared that SUV of 2 mm was higher than that of 4 mm. Also the smaller the volume was, the more the change rate increased. Conclusion: After analyzing the result of the clinical picture and phantom experiments applied by Astonish TF reconstruction techniques, as the size of the volume was small, the change rate of the SUV increased. Therefore, it was necessary to further research about the SUV correction for accurate and active utilization of 2 mm reconstruction techniques which had excellent lesion discrimination ability and contrast in clinic.

  • PDF

Characteristics of stormwter runoff from highways with unit traffic volume (고속도로 자동차 통행량에 따른 강우유출수 유출 특성 분석)

  • Choi, Jiyeon;Hong, Jungsun;Kang, Heeman;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.18 no.3
    • /
    • pp.275-281
    • /
    • 2016
  • This study was conducted to analyze the runoff characteristics of the highway depending on the number of vehicles and to provide the installation proposal of an NPS pollution reduction facility. There were a total of 5 monitoring sites used for the study namely, Gyeongbu, Seohaean, Honam and Tongyeoung Dageon highway. Monitoring events started from 2006 until 2015 having a total of 44 storm events. According to monitoring statistics, the average antecedent dry days (ADD) and rainfall was 6.2 days and 19.2 mm, respectively. The Gyeongbu Highway (H-4) was recorded having the highest Average Daily Traffic and Catchment Area (ADT/CA) with $49.4car/day{\cdot}m^2$ while other site were less than $10car/day{\cdot}m^2$. The average concentration of the NPS pollutants generated from monitoring sites were 63.5 mg/L(TSS), 24.9 mg/L(BOD), 3.35 mg/L(TN), 0.63 mg/L(TP) and 298 ug/L(Total Zn). This exhibited lower values in comparison to the remarks of highway related runoff EMC values published in Korea. Moreover, through the results of the correlation analysis between the contaminant concentration and ADT/CA, $R^2$ value of SS showed the highest correlation with 585. Through the correlation equation between ADT/CA and EMC of TSS, when there is 73.7 mg/L of TSS EMC found from a domestic highway, ADT/CA ratio is normally $13car/day{\cdot}m^2$. Therefore, in a case of more than 13 cars passing through a certain area, the area can be considered and present as the point of generation of nonpoint source pollutants. Also, in this study, since it considered a unit area ADT indicated in previous studies, it was determined that it has a high applicability and utilization in generalized units than conventional study which were conventionally done.

Analysis of the growth environment and fruiting body quality of Pleurotus eryngii cultivated by Smart Farming (큰느타리(새송이)버섯 스마트팜 재배를 통한 생육환경 분석 및 자실체 품질 특성)

  • Kim, Kil-Ja;Kim, Da-Mi;An, Ho-Sub;Choi, Jin-Kyung;Kim, Seon-Gon
    • Journal of Mushroom
    • /
    • v.17 no.4
    • /
    • pp.211-217
    • /
    • 2019
  • Currently, cultivation of mushrooms using the Information and Communication Technology (ICT)-based smart farming technique is increasing rapidly. The main environmental factors for growth of mushrooms are temperature, humidity, carbon dioxide (CO2), and light. Among all the mentioned factors, currently, only temperature has been maintained under automatic control. However, humidity and ventilation are controlled using a timer, based on technical experience.Therefore, in this study, a Pleurotus eryngii first-generation smart farm model was set up that can automatically control temperature, humidity, and ventilation. After installing the environmental control system and the monitoring device, the environmental condition of the mushroom cultivation room and the growth of the fruiting bodies were studied. The data thus obtained was compared to that obtained using the conventional cultivation method.In farm A, the temperature during the primordia formation stage was about 17℃, and was maintained at approximately 16℃ during the fruiting stage. The humidity was initially maintained at 95%, and the farm was not humidified after the primordia formation stage. There was no sensor for CO2 management, and the system was ventilated as required by observing the shape of the pileus and the stipe. It was observed that, the concentration of CO2 was between 700 and 2,500 ppm during the growth period. The average weight of the mushrooms produced in farm A was 125 g, and the quality was between that of the premium and the first grade.In farm B. The CO2 sensor was in use for measurement purposes only; the system was ventilated as required by observing the shape of the pileus and the stipe. During the growth period, the CO2 concentration was observed to be between 640 and 4,500 ppm. The average weight of the mushrooms produced in farm B was 102 g.These results indicate that the quality of the king oyster mushroom is determined by the environmental conditions, especially by the concentration of CO2. Thus, the data obtained in this study can be used as an optimal smart farm model, where, by improving the environmental control method of farm A, better quality mushrooms were obtained.

Clinical Outcome of Emergency Coronary Artery Bypass Grafting after Failed Percutaneous Transluminal Coronary Angioplasty (경피적 관상동맥 성형술의 실패에 의해 발생한 응급환자의 임상경과)

  • Kim, Do-Kyun;Yoo, Kyung-Jong;Youn, Young-Nam;Yi, Gi-Jong;Lee, Sak;Chang, Byung-Chul;Kang, Meyun-Shick
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.209-214
    • /
    • 2007
  • Background: Failed percutaneous transluminal coronary angioplasty (PTCA) is occasionally required for emergency coronary artery bypass grafting (CABG). The aim of this study was to assess the outcome of patients receiving emergency CABG after failed PTCA. Material and Method: Between May 1988 and May 2005, 5712 patients underwent PTCA, where 84 (1.4%) failed. 27 patients underwent emergency CABG after failed PTCA. The mean age was $63.7{\pm}8.9\;(46{\sim}80)$ years, with 14 male patients (51.9%). Result: All patients underwent emergent surgical revascularization within 6 hours. 22 patients underwent conventional CABG and 5 underwent off-pump CABG. The causes of PTCA failure were coronary obstruction due to new thrombi formation during the procedure (n=4), coronary dissection (n=17), coronary artery rupture (n=3) and 3 due to other causes. The rate of in-hospital operative mortality after emergent operation was 18.5% (5/27). A univariate analysis revealed that patients who died more often had left anterior descending artery disease, a preprocedural shock status, postoperative use of multiple isotropics and postoperative use of intra-aortic balloon pump. The mean follow up duration was $53.6{\pm}63.4$ months. Conclusion: Although PTCA is known to be life saving, there is still a high risk for morbidity and mortality following emergency CABG after failed PTCA, despite the advancement in PTCA techniques. This result will help identify and more effectively treat patients selected for PTCA when emergency CABG is required.

Status of Agrometeorological Information and Dissemination Networks (농업기상 정보 및 배분 네트워크 현황)

  • Jagtap, Shrikant;Li, Chunqiang
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.6 no.2
    • /
    • pp.71-84
    • /
    • 2004
  • There is a growing demand for agrometeorological information that end-users can use and not just interesting information. lo achieve this, each region/community needs to develop and provide localized climate and weather information for growers. Additionally, provide tools to help local users interpret climate forecasts issued by the National Weather Service in the country. Real time information should be provided for farmers, including some basic data. An ideal agrometeorological information system includes several components: an efficient data measuring and collection system; a modern telecommunication system; a standard data management processing and analysis system; and an advanced technological information dissemination system. While it is conventional wisdom that, Internet is and will play a major role in the delivery and dissemination of agrometeorological information, there are large gaps between the "information rich" and the "information poor" countries. Rural communities represent the "last mile of connectivity". For some time to come, TV broadcast, radio, phone, newspaper and fax will be used in many countries for communication. The differences in achieving this among countries arise from the human and financial resources available to implement this information and the methods of information dissemination. These differences must be considered in designing any information dissemination system. Experience shows that easy across to information more tailored to user needs would substantially increase use of climate information. Opportunities remain unexplored for applications of geographical information systems and remote sensing in agro meteorology.e sensing in agro meteorology.

Real-Time 3D Ultrasound Imaging Method Using a Cross Array Based on Synthetic Aperture Focusing: II. Linear Wave Front Transmission Approach (합성구경 기반의 교차어레이를 이용한 실시간 3차원 초음파 영상화 기법 : II. 선형파면 송신 방법)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.403-414
    • /
    • 2004
  • In the accompanying paper, we proposed a real. time volumetric imaging method using a cross array based on receive dynamic focusing and synthetic aperture focusing along lateral and elevational directions, respetively. But synthetic aperture methods using spherical waves are subject to beam spreading with increasing depth due to the wave diffraction phenomenon. Moreover, since the proposed method uses only one element for each transmission, it has a limited transmit power. To overcome these limitations, we propose a new real. time volumetric imaging method using cross arrays based on synthetic aperture technique with linear wave fronts. In the proposed method, linear wave fronts having different angles on the horizontal plane is transmitted successively from all transmit array elements. On receive, by employing the conventional dynamic focusing and synthetic aperture methods along lateral and elevational directions, respectively, ultrasound waves can be focused effectively at all imaging points. Mathematical analysis and computer simulation results show that the proposed method can provide uniform elevational resolution over a large depth of field. Especially, since the new method can construct a volume image with a limited number of transmit receive events using a full transmit aperture, it is suitable for real-time 3D imaging with high transmit power and volume rate.

Effect of universal primer on shear bond strength between resin cement and restorative materials (다용도 프라이머가 레진 시멘트와 수복재의 전단 결합 강도에 미치는 영향)

  • Kim, Na-Hong;Shim, June-Sung;Moon, Hong-Suk;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.112-118
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the difference in shear bonding strength between resin cements to dental materials when a universal primer (Monobond plus) was applied in place of a conventional primer. Materials and methods: Four groups of testing materials: gold alloy (Argedent Euro, n = 16), non precious metal (T-4, n = 20), zirconia (Cercon, n = 20) and glass ceramic (IPS e.max press, n = 20), were fabricated into discs, which were embedded in an acrylic resin matrix. The gold alloy specimens were airborne-particle abraded, 8 of the specimens were coated with Metal primer II, while the remaining 8 specimens were coated with Monobond plus. The non precious and zirconia specimen were airborne-particle abraded then, the control group received Alloy primer coating, while the other was coated with Monobond plus. Glass ceramic specimens were etched. 10 specimens were coated with Monobond-S and the remaining specimens were coated using Monobond plus. On top of the surface, Multilink N was polymerized in a disc shape. All of the specimens were thermal cycled before the shear bonding strength was measured. Statistical analysis was done with Two sample $t$-test or Mann-Whitney U test (${\alpha}$=.05). Results: There were no significant differences in bonding strength depending on the type of primer used in the gold alloy and glass ceramic groups ($P$>.05), however, the bonding strengths of resin cements to non precious metal and zirconia groups, were significantly higher when the alloy primer was used ($P$<.05). Conclusion: Within the limitations of this study, improvement of universal primers which can be applied to all types of restorations is recommended to precious metals and zirconia ceramics. But, the bond strengths of non precious metals and zirconia ceramics were significantly lower when compared to a 10-MDP primer. More research is needed to apply universal primers to all types of restorations.

Design of a Bit-Serial Divider in GF(2$^{m}$ ) for Elliptic Curve Cryptosystem (타원곡선 암호시스템을 위한 GF(2$^{m}$ )상의 비트-시리얼 나눗셈기 설계)

  • 김창훈;홍춘표;김남식;권순학
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.12C
    • /
    • pp.1288-1298
    • /
    • 2002
  • To implement elliptic curve cryptosystem in GF(2$\^$m/) at high speed, a fast divider is required. Although bit-parallel architecture is well suited for high speed division operations, elliptic curve cryptosystem requires large m(at least 163) to support a sufficient security. In other words, since the bit-parallel architecture has an area complexity of 0(m$\^$m/), it is not suited for this application. In this paper, we propose a new serial-in serial-out systolic array for computing division operations in GF(2$\^$m/) using the standard basis representation. Based on a modified version of tile binary extended greatest common divisor algorithm, we obtain a new data dependence graph and design an efficient bit-serial systolic divider. The proposed divider has 0(m) time complexity and 0(m) area complexity. If input data come in continuously, the proposed divider can produce division results at a rate of one per m clock cycles, after an initial delay of 5m-2 cycles. Analysis shows that the proposed divider provides a significant reduction in both chip area and computational delay time compared to previously proposed systolic dividers with the same I/O format. Since the proposed divider can perform division operations at high speed with the reduced chip area, it is well suited for division circuit of elliptic curve cryptosystem. Furthermore, since the proposed architecture does not restrict the choice of irreducible polynomial, and has a unidirectional data flow and regularity, it provides a high flexibility and scalability with respect to the field size m.