• 제목/요약/키워드: Control tower

검색결과 359건 처리시간 0.027초

Intravenous patient-controlled analgesia hydromorphone combined with pregabalin for the treatment of postherpetic neuralgia: a multicenter, randomized controlled study

  • Huang, Ying;Xu, Chenjie;Zeng, Tao;Li, Zhongming;Xia, Yanzhi;Tao, Gaojian;Zhu, Tong;Lu, Lijuan;Li, Jing;Huang, Taiyuan;Huai, Hongbo;Ning, Benxiang;Ma, Chao;Wang, Xinxing;Chang, Yuhua;Mao, Peng;Lin, Jian
    • The Korean Journal of Pain
    • /
    • 제34권2호
    • /
    • pp.210-216
    • /
    • 2021
  • Background: Postherpetic neuralgia (PHN) is the most common complication of acute herpes zoster. The treatment of PHN remains a challenge for clinical pain management. Despite the effectiveness of anticonvulsants, antidepressants, and lidocaine patches in reducing PHN, many patients still face intractable pain disorders. In this randomized controlled study, we evaluated whether hydromorphone through intravenous patient-controlled analgesia (IV PCA) was effective in relieving PHN. Methods: Patients with PHN were randomly divided into two groups, one group received oral pregabalin with IV normal saline, another group received oral pregabalin with additional IV PCA hydromorphone for two weeks. Efficacy was evaluated at 1, 4, and 12 weeks after the end of the treatments. Results: Two hundred and one patients were followed up for 12 weeks. After treatment, numerical rating scale (NRS) score of patients in the hydromorphone group was significantly lower than that of the control group, and the difference of NRS scores between the two groups was statistically significant at 4 and 12 weeks after treatment. The frequency of breakthrough pain in the hydromorphone group was significantly lower than that in the control group 1 and 4 weeks after treatment. After treatment, the quality of sleep in the hydromorphone group was significantly improved compared with the control group. The most common adverse reactions in the hydromorphone group were dizziness and nausea, with no significant respiratory depression. Conclusions: IV PCA hydromorphone combined with oral pregabalin provides superior pain relief in patients with PHN, which is worthy of clinical application and promotion.

국내 건설현장 타워크레인 안전진단 관리시스템 모델에 관한 연구 (The study on the safety inspection system model of the tower crane a construction site in Korea)

  • 윤인수;서장훈;강경식
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2006년도 추계공동학술대회
    • /
    • pp.499-507
    • /
    • 2006
  • The tower cranes are widely used in very useful construction machine the sites of constructing high-structure and have a structural sensitiveness. Therefore, the accidents have often happened due to the deficiency of laborer's understanding md lack of safety of structure. Till now, as we have research and studied above, we can properly protect accidents by construction equipments particularly crane as well as most disasters which occur frequently in construction site. The goal of this study is the safety inspection model of the tower crane a construction site, which preventible the collapse accident of tower crane which is constructed by using the correcting frame. In order to accomplish the goal of this study, the field survey, the reference investigation and the structure analysis were performed for the collapse accident of tower nine using the correcting data. This study will be proposed a build-up solutions about operating and release of safety constructions and researched about software safety estimation. Also, preventing safety problems of Tower Crane Construction site as applying safety estimation program and laws and regulations. As a result, The real time control of tower crane inspection system is implemented by to illustrate the application of the adopted optimal design model.

  • PDF

국내 건설현장 타워크레인 안전진단 관리시스템 모델에 관한 연구 (A Study on the Safety Inspection System Model of The Tower Crane a Construction Site in Korea)

  • 윤인수;강경식
    • 대한안전경영과학회지
    • /
    • 제9권1호
    • /
    • pp.37-49
    • /
    • 2007
  • The tower cranes are widely used in very useful construction machine the sites of constructing high-structure and have a structural sensitiveness. Therefore, the accidents have often happened due to the deficiency of laborer's understanding and lack of safety of structure. Till now, as we have research and studied above, we can properly protect accidents by construction equipments particularly crane as well as most disasters which occur frequently in construction site. The goal of this study is the safety inspection model of the tower crane a construction site, which preventible the collapse accident of tower crane which is constructed by using the correcting frame. In order to accomplish the goal of this study, the field survey, the reference investigation and the structure analysis were performed for the collapse accident of tower crane using the correcting data. This study will be proposed a build-up solutions about operating and release of safety constructions and researched about software safety estimation. Also, preventing safety problems of Tower Crane Construction site as applying safety estimation program and laws and regulations. As a result, The real time control of tower crane inspection system is implemented by to illustrate the application of the adopted optimal design model.

다중 양중장비와 자재 야적 위치의 최적 결정을 위한 모델 개발 (Optimization of Multiple Tower Cranes and Material Stockyards Layout)

  • 김경주;김경민;이상규
    • 한국건설관리학회논문집
    • /
    • 제10권6호
    • /
    • pp.127-134
    • /
    • 2009
  • 본 연구에서는 여러 대의 타워 크레인이 다양한 후보지점을 갖고, 자재 역시 다양한 야적 후좌지점을 가질 때 자재 운반 최적화를 지원하기 위한 유전자 알고리즘 기반의 모델을 제시하고자 한다. 대형 건축공사에서 타워 크레인의 위치와 자재 야적 위치의 변화는 자재 운반시간의 변화를 가져온다. 또한 여러 대의 타워 크레인을 사용하는 경우 각 자재의 운반에 어떠한 타워 크레인을 배정하느냐에 따라 작업의 효율성이 변화한다. 따라서 본 연구에서는 다중의 타워 크레인 설치 후보지, 여러 종류의 자재, 자재 야적 후보지점간의 다양하고 복잡한 상관관계를 다루기 위하여 유전자 알고리즘을 적용한 다중 양중장비 및 자재 야적 위치 최적화모델을 제시하였다. 또한, 제시된 모델을 사례에 적용하여 적용 과정을 예시하고 활용성을 검증하였다.

Seismic performance of a wall-frame air traffic control tower

  • Moravej, Hossein;Vafaei, Mohammadreza;Abu Bakar, Suhaimi
    • Earthquakes and Structures
    • /
    • 제10권2호
    • /
    • pp.463-482
    • /
    • 2016
  • Air Traffic Control (ATC) towers play significant role in the functionality of each airport. In spite of having complex dynamic behavior and major role in mitigating post-earthquake problems, less attention has been paid to the seismic performance of these structures. Herein, seismic response of an existing ATC tower with a wall-frame structural system that has been designed and detailed according to a local building code was evaluated through the framework of performance-based seismic design. Results of this study indicated that the linear static and dynamic analyses used for the design of this tower were incapable of providing a safety margin for the required seismic performance levels especially when the tower was subjected to strong ground motions. It was concluded that, for seismic design of ATC towers practice engineers should refer to a more sophisticated seismic design approach (e.g., performance-based seismic design) which accounts for inelastic behavior of structural components in order to comply with the higher seismic performance objectives of ATC towers.

Online automatic structural health assessment of the Shanghai Tower

  • Zhang, Qilin;Tang, Xiaoxiang;Wu, Jie;Yang, Bin
    • Smart Structures and Systems
    • /
    • 제24권3호
    • /
    • pp.319-332
    • /
    • 2019
  • Structural health monitoring (SHM) is of great importance to super high-rise buildings. The Shanghai Tower is currently the tallest building in China, and a complete SHM system was simultaneously constructed at the beginning of the construction of the tower. Due to the variety of sensor types and the large number of measurement points in the SHM system, an online automatic structural health assessment method with few computations and no manual intervention is needed. This paper introduces a structural health assessment method for the Shanghai Tower that uses the coefficients of an autoregressive (AR) time series model as structural state indicators. An analysis of collected data indicates that the coefficients of the AR model are affected by environmental factors, and the principal component analysis method is used to remove the influence of environmental factors. Finally, the control chart method is used to track the changes in structural state indicators, and a plan for online automatic structure health state evaluation is proposed. This method is applied to long-term acceleration and inclination data from the Shanghai Tower and successfully identifies the changes in the structural state. Overall, the structural state indicators of the Shanghai Tower are stable, and the structure is in a healthy state.

A review of wind-turbine structural stability, failure and alleviation

  • Rehman, Shafiqur;Alam, Md. Mahbub;Alhems, Luai M.
    • Wind and Structures
    • /
    • 제30권5호
    • /
    • pp.511-524
    • /
    • 2020
  • Advancements in materialistic life styles and increasing awareness about adverse climatic changes and its negative effects on human life have been the driving force of finding new and clean sources of energy. Wind power has become technologically mature and commercially acceptable on global scale. However, fossil fuels have been the major sources of energy in most countries, renewable energy (particularly wind) is now booming worldwide. To cope with this wind energy technology, various related aspects have to be understood by the scientific, engineering, utility, and contracting communities. This study is an effort towards the understanding of the (i) wind turbine blade and tower structural stability issues, (ii) turbine blade and tower failures and remedial measures, (iii) weather and seismic effects on turbine blade and tower failures, (iv) gear box failures, and (v) turbine blade and tower failure analysis tools.

Electromagnetic Field Analysis on Surge Response of 500 kV EHV Single Circuit Transmission Tower in Lightning Protection System using Neural Networks

  • Jaipradidtham, Chamni
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1637-1640
    • /
    • 2005
  • This paper presents a technique for electromagnetic field analysis on surge response due to Mid-span back-flashovers effects in lightning protection system of 500 kV EHV single circuit transmission tower by the neural networks method. These analyses are based on modeling lightning return stroke as well as on coupling the electromagnetic fields of the stroke channel to the line. The ground conductivity influences both the electric field as well as the coupling mechanism and hence the magnitude and wave shape of the induced voltage. The technique can be used to analyzed the corona voltage effect, the effective of stroke to the span tower, the surge impedance of transmission lines. The maximum voltage from flashovers effects in the lines. The model is compatible with general electromagnetic transients programs such as the ATP-EMTP. The simulation results show that this study analyses for time-domain with those produced by a cascade multi-section model, the surge impedance of a full-sized tower hit directly by a lightning stroke is discussed.

  • PDF

가정용 흡수식 냉온수기용 냉각탑의 성능특성 (Performance Characteristics of Cooling Tower on Small Absorption Chiller)

  • ;김은필;정석권;민경현;김재돌;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권7호
    • /
    • pp.1145-1151
    • /
    • 2004
  • The experiment of thermal performance about cross flow type cooling tower was conducted in this study. Generally the ambient air condition can affect the thermal performance of cooling tower to improve or not. However it is hard to control the cooling water temperature that we want under bad air condition or during rainy season. In this paper, the effect of variables, which the ambient air have. especially wet-bulb temperature, are experimentally investigated for controlling the cooling water temperature more successfully. The result is that there is appropriate air flow rate in respective air condition to preserve the cooling performance in the cooling tower and the maximum air flow rate can't overcome the approach under bad air condition.

승강기식 타워주차설비 고장 모니터링 시스템 개발 (The development of fault monitoring system for lift type parking facility)

  • 이원태;차정섭;정영경;김관호;김박의
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.739-741
    • /
    • 1999
  • This paper describes the fault monitoring system for lift type tower parking facilities. This system consists of tower parking facility control panel and monitoring computer, and offers real-time monitoring of parking status and fault detection, and status data acquisition of tower parking system using graphic user interface.

  • PDF