• Title/Summary/Keyword: Control Rooms

Search Result 263, Processing Time 0.025 seconds

Characterisation of fungal contamination sources for use in quality management of cheese production farms in Korea

  • Kandasamy, Sujatha;Park, Won Seo;Yoo, Jayeon;Yun, Jeonghee;Kang, Han Byul;Seol, Kuk-Hwan;Oh, Mi-Hwa;Ham, Jun Sang
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.6
    • /
    • pp.1002-1011
    • /
    • 2020
  • Objective: This study was conducted to determine the composition and diversity of the fungal flora at various control points in cheese ripening rooms of 10 dairy farms from six different provinces in the Republic of Korea. Methods: Floor, wall, cheese board, room air, cheese rind and core were sampled from cheese ripening rooms of ten different dairy farms. The molds were enumerated using YM petrifilm, while isolation was done on yeast extract glucose chloramphenicol agar plates. Morphologically distinct isolates were identified using sequencing of internal transcribed spacer region. Results: The fungal counts in 8 out of 10 dairy farms were out of acceptable range, as per hazard analysis critical control point regulation. A total of 986 fungal isolates identified and assigned to the phyla Ascomycota (14 genera) and Basidiomycota (3 genera). Of these Penicillium, Aspergillus, and Cladosporium were the most diverse and predominant. The cheese ripening rooms was overrepresented in 9 farms by Penicillium (76%), while Aspergillus in a single farm. Among 39 species, the prominent members were Penicillium commune, P. oxalicum, P. echinulatum, and Aspergillus versicolor. Most of the mold species detected on surfaces were the same found in the indoor air of cheese ripening rooms. Conclusion: The environment of cheese ripening rooms persuades a favourable niche for mold growth. The fungal diversity in the dairy farms were greatly influenced by several factors (exterior atmosphere, working personnel etc.,) and their proportion varied from one to another. Proper management of hygienic and production practices and air filtration system would be effective to eradicate contamination in cheese processing industries.

Healing Design for Adolescent Patients and the Meaning of Home - American Adolescents' Preferences on Hospital Settings - (청소년을 위한 치유병원 디자인과 집의 의미와의 관계 - 미국 청소년을 대상으로 한 선호도 조사를 중심으로 -)

  • Kim, Eun Young
    • Journal of the Korean housing association
    • /
    • v.25 no.3
    • /
    • pp.93-103
    • /
    • 2014
  • The objective of the present study is to investigate healing design attributes for adolescent patients and to identify the relationship among healing design attributes and the meaning of home. This study examined the environmental preferences of American adolescents for hospital rooms to investigate age-appropriate healing design attributes. The health-related quality of life (HRQOL) concept was adapted to this study as a theoretical framework. One hundred six American adolescents participated in the survey. Participant adolescents consisted of two groups by their health status: forty-seven adolescent patients who were waiting for their surgical operations in waiting rooms and fifty-nine healthy high school students while they were at school. Participants aged in range from 14-year to 18-year olds with a mean of 16-year olds. Data collection consisted of two different instruments: Emotional state survey with demographics and environmental preference survey. Environmental values that are important to adolescents were control of privacy, having outside view, and quiet places to go. However, staying in a single-bed room for hospitalization is ranked the lowest score for the participating adolescents. Adolescents who perceived higher stress level preferred to have quiet places to go, to control over privacy and to have outside view significantly. The study resulted that the most important design attribute for American Adolescents was "privacy control", which is the essence of the meaning of home. There are some significant discrepancies in environmental preferences of hospital rooms by different genders and different health status.

The Effects of Music Intervention on Environmental Stress and Sleep Quality in Patients with Liver Transplantation (음악중재가 간이식 환자의 환경 스트레스와 수면의 질에 미치는 효과)

  • Lee, In-Seon;Park, Hyoung-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.26 no.2
    • /
    • pp.75-85
    • /
    • 2019
  • Purpose: The purpose of this study was to examine effects of music intervention on environmental stress and sleep quality in liver transplant patients who are receiving care in one-person isolation rooms of an ICU. Methods: The study was a quasi-experimental design pre-and-post nonequivalent control group. Participants were 37 patients (18 in the experimental group and 19 in the control group) who, after receiving liver transplant, were hospitalized in one-person isolation rooms of the ICU. The study covered patients admitted between August 2016 and December 2017. Earplugs and sleep shades were provided as ordinary care to both experimental and control groups, and music intervention was provided to the experimental group three times a day for 30 minutes each from the first day of hospitalization. Results: The first hypothesis, "The experimental group who received music intervention will experience a lower environmental stress level than the control group" was supported (Z=-3.212, p<.001). The second hypothesis, "The experimental group who received music intervention will experience a higher sleep quality than the control group" was also supported (t=3.715, p=.001). Conclusion: Findings show that music intervention is an effective nursing intervention to reduce environmental stress and improve sleep quality in liver transplant patients in the ICU.

Development of a precision smoke particle detector to sense a fire in early state (초기화재 감지를 위한 정밀한 연기 입자 감지 장치 개발)

  • 김희식;김영재;이호재
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1734-1737
    • /
    • 1997
  • The conventional fire detection devices are operated after a processed fire phase, which are sensing only a high density of somke level or high temperature heat. They are not so precision to detect a fire in the early phase to protect the facility form the fire. We need to develope a new high precision smoke detection system to keep expensive industrial facilities most reliably form fire. A new optical precision smoke detection system was developed. It monitors very low level density of smoke particles in the air. It is operated continously through many years without a stop or any malfunction. The developed precision smoke detection system will be installed in important industrial facilities, such as power plants, underground common tunnel, main control rooms, computer rooms etc.

  • PDF

A Study of Flow Characteristics through the Speed Control and Flow Resistance (유로저항에따른 속도제어를 통한 Zone별 유량특성 연구)

  • Oh, Byung-Kil;Kim, Hway-Suh
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.11
    • /
    • pp.762-768
    • /
    • 2011
  • We use floor radiant heating system in the house of commons in winter Floor radiant heating system, which transfer heat by radiation, is one of the energy efficient and comfortable systems that. Floor radiant heating system is configured to be controlled by the room for energy-saving. Proper flow rate to a comfortable heating in the room is important. However, Using a constant speed circulation pump in separate rooms, heating system may cause an imbalance because of the difference of length of coil when operating in the rooms. In this study, our Research team examined heating imbalance due to the variation length through the coil length changes and flow control of the circulation pump.

An Experiment on Performance Evaluation of a Direct Atomization Type Air Washer System for Semiconductor Clean Rooms (반도체 클린룸용 직접분무식 에어와셔 시스템의 성능평가실험)

  • Yeo, Kuk-Hyun;Yoo, Kyung-Hoon;Tae, Kyung-Eung
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.988-992
    • /
    • 2006
  • In recent semiconductor manufacturing clean rooms, air washers are used to remove airborne gaseous contaminants such as $NH_3,\;SO_x$ and organic gases from outdoor air introduced into clean room. Meanwhile, there is a large quantity of exhaust air from clean room. It is desirable to recover heat from exhaust air and use it to reheat outdoor air. In the present study, an experiment was conducted to investigate the heat recovery and gas removal efficiencies of a direct atomization type heat recovery air washer.

  • PDF

A Study on the Operation Strategy of Radiant Floor Cooling in Apartment Buildings (공동주택에서 바닥복사냉방의 적정 운영방안에 관한 연구)

  • 조영흠;석호태;여명석;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.6
    • /
    • pp.574-583
    • /
    • 2004
  • In this study, the operation strategy of the radiant floor cooling is evaluated in terms of indoor environmental conditions and energy consumption through simulations using the TRNSYS comparing the existing cooling operation. The operation strategy during continuously operated for cooling is proposed that a representative room had additional equipments and other rooms were operated with only a radiant floor cooling system and that system and control method for cooling are varied with period while intermittently operated for cooling. Specifically, when there are no people in the room, rooms were operated by only radiant floor cooling system using cooling storage and when people are occupied, rooms were operated by dehumidification and supplementary cooling device with radiant floor cooling system. The results of this study show that proposed operation strategy can stably maintain the set room air temperature and can reduce the energy consumption compared to the existing cooling method during continuously operated for cooling. While intermittently operated for cooling, the difference of set room air temperature by proposed operation strategy does not happen, satisfying comfort standards and the radiant floor cooling can expect to supply stable electric power because of decreasing demand for peak electric power of energy consumption.

A Novel Web-based Management of Networked Display for Advanced Collaboration Environment

  • Ramachandra, Vinay;Han, Sang-Woo;Bae, Chang-Hyeok;Kim, Jong-Won
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.221-226
    • /
    • 2009
  • Not many years ago, people found the contemporary technology expensive and difficult to use in collaborative type of meetings. Today, with the technology advanced to high standards and accessible at cheaper price, its adaption is becoming more and more ubiquitous with wide range of applications. Today's meeting rooms are not just plain old telephone systems with microphones and speakers. Today's meeting rooms are smart and intelligent. They can identify the participants; they can provide natural view of remote participants; they can proactively manage resources for collaboration and so on. More effective collaboration is possible with deployment of devices like high-definition cameras, advanced displays, sensors, gigabit networks, trackers, pointers, and high-end audio devices. Devices alone are not enough in the meeting rooms. We need software infrastructure to manage the devices and meeting contexts. One such software infrastructure is SMeet, a Smart Meeting space, which we have developed to provide an effective multi-party remote collaboration environment. Networked display systems are used in such advanced collaboration environment for better visualization. In this paper we discuss a novel approach to control and manage networked display systems in SMeet environment.

  • PDF

A Human-Environment Design for Main Control Rooms in SHIN-KORI 1.2 Nuclear Power Plants (신고리 1, 2호기 원자력발전소 주제어실 환경설계)

  • Byun, Seong-Nam;Kim, Sa-Kil;Ryu, Je-Hyeok
    • IE interfaces
    • /
    • v.17 no.spc
    • /
    • pp.37-45
    • /
    • 2004
  • Human factors engineering design guidelines for main control rooms(MCR) in nuclear power plants(NPP) have been applied to optimize human-machine interface(HMI) between operators and their equipment on the basis of physical, physiological and cognitive aspects. However, the HMI design for MCR is not found to be sufficient to maximize operators' performance since the operators in the MCR experience excessive stress due to the environmental factors such as inappropriate interiors and illumination. Therefore, well-designed environment of the MCR may be equally important to improve human performance in the MCR. The objectives of the study are two-fold: (1) to propose an interior design of SHIN-KORI 1 2 for pleasant and comfortable working environments, and (2) to design indirect lighting system to enhance visibility and productivity. The human factors engineering checklists were developed to examine whether or not the proposed human-environment design for SHIN-KORI 1 2 satisfies the regulations and guidelines presented by NUREG-0700 Revision 1. The implications of the human-environment design are discussed in detail.

Numerical Analysis on Energy Consumption of an Exhaust Air Heat Recovery Type Outdoor Air Conditioning System for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 배기 열회수식 외기공조시스템의 에너지소비 수치해석)

  • Song, Gen-Soo;Yoo, Kyung-Hoon;Kim, Hyoung-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1306-1311
    • /
    • 2009
  • In recent semiconductor manufacturing clean rooms, in order to improve clean room air quality, air washers are used to remove airborne gaseous contaminants such as $NH_3$, SOx and organic gases from the outdoor air introduced into clean room. Meanwhile, there is a large amount of exhaust air from a clean room. From an energy conservation point of view, heat recovery is therefore useful for reducing the outdoor air conditioning load for a clean room. Therefore it is desirable to recover heat from the exhaust air and use it to reheat the outdoor air. In the present study, numerical analysis and experiment was conducted to simulate the amount of energy reduction of exhaust air heat recovery type air washer system. The present numerical results showed good agreement with the results of the experimental data.

  • PDF