• 제목/요약/키워드: Control & Monitoring system

검색결과 3,001건 처리시간 0.033초

표준화를 통한 통합형 수(水)운영시스템의 개발 (Development of Integrated Water Operation System through Engineering Standardization)

  • 한경전;김진문;전화성;이경우
    • 제어로봇시스템학회논문지
    • /
    • 제17권6호
    • /
    • pp.602-609
    • /
    • 2011
  • In this paper, we standardized the water operation system picture, process control logic, realtime database and system configuration. All aspects, including monitoring & controlling processes, symbols such as pumps, valves and pipes were standardized. As a result we have developed a specialized Integrated water operation system, iWater. We have developed a variety of advanced application programs that are essential for water treatment systems, such as IWS (Integrated Warning system), MBO(modbus opc)/LSE(LS ethernet) driver, video monitoring, self diagnosis system, network monitoring, etc. IWS prevents water supply accidents by using a variety of alarms and warning messages. Drivers have the flexibility to communicate with other 3rd party systems. We expect that iWater will eliminate any concerns regarding water-related issues while also promoting the production and fair distribution of clean water.

마이크로프로세서를 이용한 인터넷 원격감시제어 시스템에 관한 연구 (A study on the Internet control and monitoring system using a microprocessor embedded controller)

  • 서인호;문복산;김경엽;김영일;천행춘;유영호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2000년도 추계학술대회 논문집(Proceeding of the KOSME 2000 Autumn Annual Meeting)
    • /
    • pp.152-156
    • /
    • 2000
  • Many industrial equipments use RS-232C interface. But Ethernet using CSMA/CD was widly spread recently. This interface is not compatible with RS-232C and requires PC based system. So In this Paper, We decribe a Internet control and monitoring system that control and watch plants without PC. We developed IP controller consisted of microprocessor and NIC and monitoring system using VC++ and SQL database. The protocol used this system is UDP/IP because it is applicable for real time system.

  • PDF

AJAX를 이용한 소방엔진펌프의 모니터링과 제어 시스템 구현 (Implementation of Monitoring and Control System for Fire Engine Pump using the AJAX)

  • 양오;이헌국
    • 반도체디스플레이기술학회지
    • /
    • 제15권3호
    • /
    • pp.40-45
    • /
    • 2016
  • In this paper, the fire engine pump is controlled and monitored by the AJAX (Asynchronous Javascript and Xml) in the web server. The embedded system with built-in system having a processor and a memory of high performance occurs many problems in transmitting the large amount of data in real time through the web server. The AJAX is different from HTML (Hyper Text Makeup Language) with java script technology and can make RIA (Rich Internet Application). It process the necessary data by using asynchronous and it take advantage of usefulness, accessibility, a fast response time. Using AJAX can build up web server with real time and monitoring that fire engine pump status, check processing pump memory in the event of fire, also remotely monitors can do. The web server system can control the fire engine pump as like the black box. The experimental results show the effectiveness and commercialize possibility.

임베디드 리눅스를 이용한 웹 기반 빌딩자동화시스템 (Web-based Building Automation System using Embedded Linux)

  • 신은철;이수영;최병욱
    • 제어로봇시스템학회논문지
    • /
    • 제10권4호
    • /
    • pp.334-340
    • /
    • 2004
  • In this paper, a Web-based management system for the building network is described. A multi-protocol converter based on SoC and embedded Linux is designed. The open source licensing, reliability, and broad hardware support are key reasons for use of embedded Linux in embedded industry. The multi-protocol converter integrates control network of RS-485 and LonWorks devices through TCP/IP protocol for a client with Java applet. The system consists of three-tier architecture, such as a client, a server that is performed on a multi-protocol converter, and control devices. The developed system includes the inverter motor control system with modbus protocol for the RS-485 network. The experiment results show that the multi-protocol converter using embedded Linux is a flexible and effective way to builda Web -based monitoring and control system.

빌딩용 신.재생에너지시스템 제어를 위한 LonWorks기반 원격 제어모듈 개발 (Web based control modules Using LonWorks/Ethernet Server for Control a large Scale Renewable Energy System in Building)

  • 홍원표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1706-1711
    • /
    • 2008
  • This paper proposes a new Web based-control concept & design method and implementation of LonWorks network system for a large scale renewable energy energy control and monitoring system in building. The Experimental LonWorks network system using LonWorks/Ethernet(Web) server is designed and fabricated. This article addresses issues in architecture of LonWorks/Ethernet sever, embedded processors architecture for converting LonTalks protocol to Modbus protocol and software, and Internet technologies. It is also verified that the multi-induction motor control and monitoring system using LonWorks/Ethernet server have available, interoperable, reliable performance characteristics from the experimental results, Especially, The seamless integration of TCP/IP networks with control networks allows access to any control point from anywhere. Thus, the results provide a available technical data for remote distributed control system of industrial and buildings field.

  • PDF

저온냉장장치용 온도제어기의 원격 모니터링 시스템 개발 (Development of Remote Monitoring System of Temperature Controller for Cold-Storage)

  • 임대영;유영재;장영학;문채주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2486-2488
    • /
    • 2003
  • This paper describes a remote monitoring system of temperature controller for cold-storage, of farm produce. In the cold-storage, it is important that farm produces are fresh. Unfortunately, when an operator goes out from the cold-storage temperature change could be occurred due to the various reasons, for an example, a valve of cooler is broken. The temperature change results in a serious problem of the quality of farm produce. To prevent the problem, the operator has to look to the current state of the temperature of the cold-storage, even he is in long away. Thus, the monitoring system to show the temperature should be required to the operator who can move away. Therefore, this paper propose of the remote monitoring system of the temperature. The proposed system is expected to help the operator's facilities, and the management of farm produce.

  • PDF

보안관제시스템 구성 및 개선방안 연구 (On the Configuration and Improvement of Security Control Systems)

  • 유승재
    • 융합보안논문지
    • /
    • 제17권2호
    • /
    • pp.69-80
    • /
    • 2017
  • IT시대의 고도화로 인한 사이버 범죄는 지능화, 다양화, 고도화 되고 있는 가운데 보안 관제의 역할은 더욱 중요해졌다. 과거 방화벽이나 IDS 등 보안 장비에만 의존하던 방식과는 달리 실시간 감시를 통해 사이버 공격에 대한 대응을 하는 보안 관제 업무가 광범위해지고 그 역할 또한 중요하게 되었다. 현재의 사이버 위협에 대해 보안 장비만으로는 안정적인 방어를 할 수 없기 때문에 보안 장비를 운영 및 감시하고 실시간적인 대응을 할 수 있는 보안 관제의 업무가 필수 요소가 된 것이다. 본 연구에서는 네트워크 보안시스템을 효율적으로 구성하는 방법과 보안시스템을 실시간 운영하는 보안관제의 현황과 개선방안에 대해 다루고자 한다.

Development of Long-Term Storage Technology for Chinese Cabbage - Physiological Characteristics of Postharvest Freshness in a Cooler with a Monitoring and Control Interface

  • Lim, Ki Taek;Kim, Jangho;Chung, Jong Hoon
    • Journal of Biosystems Engineering
    • /
    • 제39권3호
    • /
    • pp.194-204
    • /
    • 2014
  • Purpose: The aim of this study was to develop long-term storage technology for Chinese cabbage in order to extend the period of availability of freshly harvested products. The scope of the paper deals with the use of a cooler with a remote monitoring and control interface in conjunction with use of packaging film. Methods: A cooler with a real time monitoring system was designed as a low-temperature storage facility to control temperature and relative humidity (RH). The effects of storage in high-density polyethylene (HDPE) plastic boxes, 3% chitosan dipping solution, polypropylene film (PEF) with perforations, and mesh packaging bags on physiological responses were investigated. The optimal storage temperature and humidity for 120 days were below $0.5^{\circ}C$ and 90%, respectively. Physiological and biochemical features of cabbage quality were also analyzed: weight loss, texture, and sugar salinity, chlorophyll, reducing sugar, and vitamin C contents. Results: The cooler with a remote monitoring and control interface could be operated by an HMI program. A $0.5^{\circ}C$ temperature and 90% humidity could be remotely controlled within the cooler for 120 days. Postharvest freshness of Chinese cabbages could be maintained up to 120 days depending on the packaging method and operation of the remote monitoring system. In particular, wrapping the cabbages in PEF with perforations resulted in a less than a 5% deterioration in quality. This study provides evidence for efficient performance of plastic films in minimizing post-harvest deterioration and maintaining overall quality of cabbages stored under precise low-temperature conditions with remote monitoring and a control interface. Conclusions: Packaging with a modified plastic film and storage in a precisely controlled cooler with a remote monitoring and control interface could slow down the physiological factors that cause adverse quality changes and thereby increase the shelf life of Chinese cabbage.

An Effective Multivariate Control Framework for Monitoring Cloud Systems Performance

  • Hababeh, Ismail;Thabain, Anton;Alouneh, Sahel
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권1호
    • /
    • pp.86-109
    • /
    • 2019
  • Cloud computing systems' performance is still a central focus of research for determining optimal resource utilization. Running several existing benchmarks simultaneously serves to acquire performance information from specific cloud system resources. However, the complexity of monitoring the existing performance of computing systems is a challenge requiring an efficient and interactive user directing performance-monitoring system. In this paper, we propose an effective multivariate control framework for monitoring cloud systems performance. The proposed framework utilizes the hardware cloud systems performance metrics, collects and displays the performance measurements in terms of meaningful graphics, stores the graphical information in a database, and provides the data on-demand without requiring a third party software. We present performance metrics in terms of CPU usage, RAM availability, number of cloud active machines, and number of running processes on the selected machines that can be monitored at a high control level by either using a cloud service customer or a cloud service provider. The experimental results show that the proposed framework is reliable, scalable, precise, and thus outperforming its counterparts in the field of monitoring cloud performance.

공정 모니터링과 조절에 있어 이상원인의 문제 (Problems of Assignable Causes in Process Monitoring and Adjustment)

  • 이성철;전상표
    • 대한안전경영과학회지
    • /
    • 제2권4호
    • /
    • pp.19-32
    • /
    • 2000
  • Assignable causes producing temporary deviation from the underlying system can influence on process adjustment and process monitoring in dynamic feedback control system. In this paper, the impact of assignable causes on EWMA forecasts and process adjustment which is based on the EWMA forecasts are derived for optimum control methods.

  • PDF