• Title/Summary/Keyword: Contact diameter

Search Result 491, Processing Time 0.032 seconds

Effects of electrical stimulation on healing of endo-osseous titanium implants in circumferential defect (전기자극이 성견 골결손부에 매식된 임플란트 주위조직의 치유에 미치는 영향)

  • Shim, Jae-Chang;Kim, Young-Jun;Chung, Hyun-Ju;Kim, Ok-Su
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.177-193
    • /
    • 2004
  • Several experimental studies showed that the application of small amounts of electric current to bone stimulated osteogenesis at the site of the cathode and suggested that electrical currents promote osseointegration around dental implants. The purpose of this study was to determine the effect of direct microcurrent to endosseous titanium implants placed in bone defects. The right and left 2nd, 3rd and 4th mandibular premolars in ten mongrel dogs (15Kg of weight) were extracted. One monthe later, Ti-machined screw type implants(3.8 mm diameter x 8.5 mm length, $AVANA^{(R)}$, Ostem) were placed in surgically created circumferential defect area(width 5mm, depth 4mm). The implants were divided into three groups according to the treatment modalities: Control group- implants without electrical stimulation; Experimental group I- implants with allogenic demineralized freeze dried bone grafting; and Experimental group II-implants allogenic demineralized freeze dried bone grafting and electric stimulation. The animals were sacrificed in the 4th and 8th week after implant placement and un-decalcified specimens were prepared for histological and histometrical evaluation of bone-implant contact ratio (BIC) and bone formation area ratio (BFA) in defect area. Some specimens at 8 weeks after implantation were used for removal torque testing. Histologically, there was connective tissue infiltration in the coronal part of defect area in control and the experimental group I, whereas direct bone contact was found in the experimental group II without connective tissue invasion. Average BIC ratios at 4 weeks of healing were 60.1% in the experimental group II, 47.4% in the experimental group I and 42.7% in the control. Average BIC ratios at 8 weeks after implantation were 67.6% in the experimental group II, 55.9% in the experimental group I and 54.6% in the control. The average BFA ratio was 84.0% in the experimental group II, 71.8% in the experimental group I and 58.8% in the control at 4 weeks, and the BFA ratios were 89.6% in the experimental group II, 81.4% in the experimental group I and 70.5% in the control at 8 weeks after implantation. The experimental group II showed also significantly greater BIC and BFA ratios compared to the control and the experimental group I (p<0.05). The removal torque values at 8 weeks after implantation were 56 Ncm in the experimental group II, 49 Ncm in the experimental group I and 43 Ncm in the control. There was a statistically significant difference among 3 groups (p<0.05). These results suggest that electrical stimulation improve and accelerate bone healing around endosseous titanium implants in bone defect.

THE EVALUATION OF THE REMOVAL TORQUE AND THE HISTOMORPHOMETRY OF THE CA-P COATING SURFACE IN RABBIT TIBIA (가토 경골에 식립된 Ca-P 박막코팅 임프란트의 뒤틀림 제거력 및 조직형태학적 평가)

  • Kwak Myeong-Bae;Lee Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.556-571
    • /
    • 2004
  • Statement of problem: Surface texture of the implant is one of the important factors of the implant success, especially in the immediate implant loading. Many methods of the surface treatment of implant have developed and introduced. Purpose : This study was to evaluate the effects of the Ca-P coating implant crystallized the hydroxyapatite on the surface by the removal torque test and the histomorphometric analysis in vivo. Material and methods: 135 screw type implants, 4.0mm in length and 3.75mm in diameter were used in this study. Implants were divided into 3 groups and treated in the different mothods. Group I was not treated, Group II was treated in the SLA method, and Group III was treated in the Ca-P coating with the anodizing method and the hydroxyapatite was crystallized on the surface with the hydrothermal treatment. Firstly, the surface roughness of each group was measured, 45 rabbits were used in this experiment. Two implants were inserted on right tibial metaphysis and one implant was inserted on left side with the alternating order. After the healing periods of 3, 5, and 12 weeks, the rabbits were sacrificed to evaluate the osseointergration by the removal torque test and the histomorphometric analysis. Results : 1. In the analysis for the surface roughness, Group II showed the highest roughness. And Group III showed higher secondly. There was a significant difference one another statistically 2. In the removal torque test, Group III and II were significantly higher than Group I. There was no statistical difference between Group III and Group II. 3. For all Groups, the removal torque values at 12th week were significantly higher than at 3rd and 5th week. 4. In histomorphometric analysis, the bone implant contact rates of Group III and II were higher than that of Group I at 3rd and 5th week. There was a significant difference at 5th week. 5. In histomorphometric analysis, the bone implant contact rate of Group III and II increased from 3rd week to 5th week, but decreased at 12th week. In Group I, the contact rate at 12th week was significantly higher than at 3rd week and 5th week.

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS : HISTOMORPHOMETRIC, PERIO TEST VALUE AND RESONANCE FREQUENCY ANALYSIS IN BEAGLE DOGS

  • Choi, Joon-Eon;Suh, Kyu-Won;Lee, In-Ku;Ryu, Jae-Jun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.362-374
    • /
    • 2007
  • Statement of problem. The intial stability for osseointegration of implant has been an interesting factor. Especially, in the case of poor bone quality or immediately loaded implant, various strategies have been developed focusing on the surface of materials to improve implant fixation to bone. The microscopic properties of implant surfaces play a major role in the osseous healing of dental implants. Purpose. The aims of this study are to perform a histologic and histomorphometric comparison of the healing characteristics of three different surfaces and the comparison of resonance frequency analysis (RFA) values measured by $Osstell^{TM}$ and perio-test values (PTV) measured by Periotest. Material and methods. A total of 24 screw titanium implants (Dentium Co., Seoul, Korea) with 6mm in length and 3.4mm in diameter, were placed in the mandible of 4 beagle dogs. Implants were divided into three groups following the surface treatment methods: Group I is machined(control group). Group II is anodically oxidized. Group III is coated 500nm in thickness with hydroxyapatite(HA) by ion beam assisted deposition(IBAD) on the anodized oxidization. Bone blocks from 2 dogs were caught after 3 weeks of covered healing and another blocks from 2 dogs after 6 weeks. RFA values and PTV were measured right after insertion and at 3 and 6weeks. Histomorphometric analysis was made with Kappa Image Base System to calculate bone-to-implant contact (BIC) and bone area inside the threads. Pearson's correlation analyses were performed to evaluate the correlation between RFA and PTV, BIC and bone area ratio of three different surfaces at 3 and 6 weeks. Results. 1) In all surface treatment methods, the RFA values decreased and the PTV values increased until 6 weeks in comparison to initial values. 2) At 3 weeks, no significant difference was found from bone-to-implant contact ratio and bone area ratio of three different surface treatment methods(P>0.05). However, at 6 weeks, different surface treatment methods showed significantly different bone-toimplant contact ratio and bone area ratio(P<0.05). 3) In the implants with the IBAD on the anodic oxidization, significant difference was found between the 3 weeks and the 6 weeks bone area ratio(P<0.05). 4) Correlation was found between the RFA values and the bone area ratio at 3 and 6 weeks with significant difference(P<0.05). Conclusions. These results indicate that the implants with the IBAD on the anodic oxidization may have a high influence on the initial stability of implant.

The Study of Bone Formation around Titanium Implants Placed in Adrenalectomized Rat's Tibia (부신 제거 백서에 티타늄 임플랜트 매식후 주위 골형성에 관한 연구)

  • Choi, Kab-Lim;Kim, Jong-Ryoul;Park, Bong-Soo;Sung, Iel-Yong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.3
    • /
    • pp.274-287
    • /
    • 2000
  • The use of dental implants has increased tremendously in recent years and is expected to increase even more in the future. The successful outcome of any implant procedure is surely dependent on interrelationship of the various components of an equation that includes biocompatibility of implant material, macroscopic and microscopic nature of the implant surface, the status of implant bed, surgical technique, undisturbed healing phase and subsequent prosthetic design and long-term loading phase. The purpose of this study was to clarify the effects of adrenalectomy on the osseointegration of pure titanium implants. Seventy rats, 11 weeks of age, were divided into two groups : an adrenalectomized group and a control group. Titanium screw implant(diameter, 2.0mm; length, 3.5mm) was placed into left tibia of 70 rats, 35 in control group and 35 in the experimental group. The rats were sacrificed at different time interval (1, 2, 3, 4, 6, 8, and 12 weeks after implantation) for histopathologic observation, histomorphometric analysis and immunohistochemistry with fibronectin and CD44 antibody. The results obtained from this study were as follows: 1. Histopathogically, findings, newly formed bone was seen at 3 weeks control group and became lamellar bone at 12 weeks. At 6 weeks, lipocytes were observed in bone marrow space. Thickness of regenerated trabecular bone increased till 6 weeks after then, that decreased gradually. 2. By histomorphometric analysis, marrow bone density and contact ratio of marrow bone to implant decreased significantly from 8 to 12 weeks in experimental group compared to control group and also total bone to implant contact ratio decreased significantly from 4 to 12 weeks in experimental group compared to control group. 3. Fibronectin immunoreactivity was very strong at 3 and 4 weeks control group. And after that reduced gradually. But it was continuously strong from 1 to 12 weeks experimental group. 4. CD44 immunoreactivity was very strong in the newly formed osteoblasts at 3 and 4 weeks control group. But it reacted minimally later. However, it reacted continuously strong from 3 to 12 weeks experimental group. From these results, bone to implant contact ratio decreased gradually from 4 weeks in adrenalectomized group compared to control group. CD44 and fibronectin immunoreactivities were strong at all times in adrenalectomized rats. Therefore, it could be stated that immature bone remained continuously for a long time and not readily proceeded into mature status.

  • PDF

Effect of Partial Laser Assisted Hatching on Mouse Embryos (레이져를 이용한 부분적 보조부화술이 생쥐 수정란의 부화에 미치는 효과)

  • Kim, Dong-Hoon;Kim, Myo-Kynng;Lee, Hoi-Chang;Ko, Duck-Sung;Park, Won-Il;Kwon, Hynck-Chan;Lee, Ho-Joon
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.28 no.2
    • /
    • pp.147-153
    • /
    • 2001
  • Objective: The present study was performed to investigate the efficiency of partial laser assisted hatching (p-LAH; lased 1/2 ZP width from ZP edge) on hatching of mouse blastocysts. Methods: We used non-contact $1.48{\mu}m$ diode laser (MTM, Switzland) to create a precise hole on zona pellucida. 2-cell embryos were collected from the mouse (ICR) oviduct at 48 hours after hCG administration. Collected 2-cell embryos were cultured in the P-1 medium supplemented with 0.4% BSA. For experiments, embryos at 8-cell stage were used after $20{\sim}22$ hours in culture. After conventional (c-LAH) or partial laser assisted hatching, the embryos were further cultured in P-1 medium supplemented with 0.4% BSA for 3 days. To compare efficiency of complete and partial laser assisted hatching, hatching rate, hatching time and blastocyst diameter and zona pellucida thickness at hatching time were investigated. Embryos were examined every 12 hours. Blastocyst diameter and zona pellucida thickness at hatching time were measured with an ocular micrometer. Results: Hatching rates of p-LAH group (84.2%) was significantly higher than that of control group (39.3%), but there was no difference between the p-LAH (84.2%) and c-LAH (91.2%). p-LAH group was hatched 12 hours earlier than control group, but hatched 12 hours later than c-LAH group. The diameter of blastocyst at hatching time of p-LAH group ($113.1{\pm}6.4{\mu}m$) was smaller than that of control group ($122.2{\pm}5.0{\mu}m$), but larger than that of c-LAH group ($102.2{\pm}2.7{\mu}m$). Zona pellucida thickness at hatching time of p-LAH group ($6.4{\pm}0.9{\mu}m$) was thicker than that of control group ($4.5{\pm}1.5{\mu}m$), but thinner than that of c-LAH group ($10.0{\pm}0.8{\mu}m$). Conclusion: These results suggest that p-LAH may maintains the cell arrangement of early embryos to ensure successful development and prevent precocious hatching of blastocyst when compare to c-LAH and conventional (acidic tyrode) AH. Thus, p-LAH may provide a valuable and effective AH technique for human ART program.

  • PDF

The Change in the Parameters of Silicone Hydrogel Lens and Objective/Subjective Symptoms induced by Repetitive Dryness of Lens (실리콘 하이드로겔 렌즈의 반복적 건조로 인한 렌즈형태 및 자·타각적 증상의 변화)

  • Kim, So Ra;Kang, Byeong Ho;Jung, In Pil;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.381-388
    • /
    • 2012
  • Purpose: In this study, the changes in the shape of silicone hydrogel lenses, dryness of lens and objective/ subjective symptoms that could be induced by repeating dryness of lens and objective/subjective symptoms were investigated. Methods: After drying and rehydrating of silicone hydrogel lenses with different lens material and thickness for 4 times, their overall diameters and base curves were compared. Subjective symptoms, non-invasive tear break-up time (NIBUTs) and blinking rate were evaluated after wearing dehydrated silicone hydrogel lens. Results: Overall diameter and base curve increased in all tested silicone hydrogel lenses by repeating dryness and rehydration. The degree of change in over all diameter and base curve were variable on the material. There were irregular change of lens parameters in thicker lens. When the subjects wore silicone hydrogel lenses after drying and rehydrating, their NIBUTs were decreased and blink rates were increased regardless of lens material or thickness. In addition, repetitive drying of silicone hydrogel lenses affected the lens fitting. Therefore, subjective symptoms such as itching, pain, irritation, foreign body sensation, dryness tended to be increased. Conclusions: The results obtained from the study may suggest to develop durable silicone hydrogel contact lenses against dry environment since the changes in parameters of silicone hydrogel lens and the subjective discomfort were observed after repetitive drying and rehydration.

Instability of Plunging Breaking Wave Impact on Inclined Cylinder (경사진 실린더에 작용하는 플런징 쇄파 충격력의 불안정성 고찰)

  • Hong, Key-Yong;Shin, Seung-Ho
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.10 no.4
    • /
    • pp.187-192
    • /
    • 2007
  • Impact on cylindrical surface caused by plunging breaking waves is investigated experimentally. The breaking waves are generated in a wave flume by decreasing the wave maker frequencies linearly and focusing the generated wave components at one specific location. The breaking wave packets are based on constant wave steepness spectrum. Three inclination angles of cylinder are applied to examine the effect of contact angle between cylinder and front surface of breaking waves. Also, the effect of cylinder diameter on pressure distribution and its peak value is investigated by adopting three cylinders with different diameters. The longitudinal location of cylinder is slightly moved in eight different points to find out a probable maximum value of impact pressure. The pressures and total force on cylinder surface are measured by piezo-electric pressure sensors and 3-components load cell with 30kHz sampling rate. The variation of peak impact pressures and forces is analyzed in terms of cylinder diameter, inclination angle and location. Also, the pressure distribution on cylindrical surface is examined. The cylinder location and surface position are more important parameters that govern the magnitude and shape of peak pressures, while the cylinder diameter and inclined angle are relatively insignificant. In a certain conditions, the impact phenomenon becomes very unstable which results in a large variation of measured valves in repeated runs.

  • PDF

Improving hydrophilic and antimicrobial properties of membrane by adding nanoparticles of titanium dioxide and copper oxide

  • Khosroyar, Susan;Arastehnodeh, Ali
    • Membrane and Water Treatment
    • /
    • v.9 no.6
    • /
    • pp.481-487
    • /
    • 2018
  • Membrane clogging or fouling of the membrane caused by organic, inorganic, and biological on the surface is one of the main obstacles to achieve high flux over a long period of the membrane filtration process. So researchers have been many attempts to reduce membrane fouling and found that there is a close relationship between membrane surface hydrophilicity and membrane fouling, such that the same conditions, a greater hydrophilicity were less prone to fouling. Nanotechnology in the past decade is provided numerous opportunities to examine the effects of metal nanoparticles on the both hydrophilic and antibacterial properties of the membrane. In the present study the improvement of hydrophilic and antimicrobial properties of the membrane was evaluated by adding nanoparticles of titanium dioxide and copper oxide. For this purpose, 4% copper oxide and titanium dioxide nanoparticles with a ratio of 0, 30, 50, and 70% of copper oxide added to the polymeric membrane and compare to the pure polymeric membrane. Comparison experiments were performed on E. coli PTCC1998 in two ways disc and tube and also to evaluate membrane hydrophilic by measuring the contact angle and diameter of pores and analysis point SEM has been made. The results show that the membrane-containing nanoparticle has antibacterial properties and its impact by increasing the percentage of copper oxide nanoparticles increases.

Thermal Performance Characteristics of Closed-Wet Cooling Tower (밀폐형 냉각탑의 열성능 특성에 관한 실험적 연구)

  • Sarker, M.M.A.;Kim, E.P.;Moon, C.G.;Yoon, J.I.
    • Journal of Power System Engineering
    • /
    • v.9 no.2
    • /
    • pp.88-92
    • /
    • 2005
  • The experiment of thermal performance about closed-wet cooling tower was conducted in this study. A closed cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The test section for this experiment has the process that the cooling water flows from the top of the heat exchanger to the bottom side in the inner part of the tube, and spray water flows in the gravitational direction in the outer side. Air comes in direct contact with the spray water at the outer side of the tube while passing from the lower the upper part having a counterflow to the spray water. The heat transfer pipe used in this experiment is a bare-type tube having an outer diameter of 15.88mm. The heat exchanger is consisted of seven rows and fifteen columns. In this experiment, thermal performance of the cooling tower is derived from overall heat transfer coefficients between the process fluid and sprayed water and volumetric overall mass transfer coefficient between sprayed water and air.

  • PDF

Design Methodology of Automotive Wheel Bearing Unit with Discrete Design Variables (이산 설계변수를 포함하고 있는 자동차용 휠 베어링 유닛의 설계방법)

  • 윤기찬;최동훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.1
    • /
    • pp.122-130
    • /
    • 2001
  • In order to improve the efficiency of the design process and the quality of the resulting design, this study proposes a design method for determining design variables of an automotive wheel-bearing unit of double-row angular-contact ball bearing type by using a genetic algorithm. The desired performance of the wheel-bearing unit is to maximize system life while satisfying geometrical and operational constraints without enlarging mounting spae. The use of gradient-based optimization methods for the design of the unit is restricted because this design problem is characterized by the presence of discrete design variables such as the number of balls and standard ball diameter. Therefore, the design problem of rolling element bearings is a constrained discrete optimization problem. A genetic algorithm using real coding and dynamic mutation rate is used to efficiently find the optimum discrete design values. To effectively deal with the design constraints, a ranking method is suggested for constructing a fitness function in the genetic algorithm. A computer program is developed and applied to the design of a real wheel-bearing unit model to evaluate the proposed design method. Optimum design results demonstrate the effectiveness of the design method suggested in this study by showing that the system life of an optimally designed wheel-bearing unit is enhanced in comparison with that of the current design without any constraint violations.

  • PDF