• 제목/요약/키워드: Confocal Fluorescence Image

검색결과 16건 처리시간 0.03초

LIF 공초점 현미경을 이용한 Y-채널 마이크로믹서의 혼합 효율 평가 (Mixing Efficiency Evaluation in Y-channel Micromixer Using LIF Confocal Microscope)

  • 김경목;신용수;안유민;이도형
    • 대한기계학회논문집B
    • /
    • 제31권2호
    • /
    • pp.159-166
    • /
    • 2007
  • Mixing between two or more reagents is one of important processes in biochemical microfluidics. In efficient micromixer design, it is essential to analyze flow pattern and evaluate mixing efficiency with good precision. In this work, mixing efficiency for Y-channel micromixer is measured by fluorescence intensity using LIF(Laser Induced Fluorescence) Confocal Microscope. The Y-channel micromixers are fabricated with polydimethylsiloxane(PDMS) and those are bonded to glass plate through Plasma bonding. Nile Blue A is injected into the micromixer as a fluorescence dye for measuring of fluorescence intensity by He/Ne laser. For visualization of the flow pattern, dynamic image capturing is carried out using CAM scope. For the comparison with computer simulation, modified SIMPLE algorithm for incompressible flow equation is solved for the same geometry as in the experiment. Throughout the experiments and computer simulation, accurate mixing efficiency evaluation process for a PDMS Y-channel micromixer is established.

Reconstruction of Collagen Using Tensor-Voting & Graph-Cuts

  • Park, Doyoung
    • 한국정보기술학회 영문논문지
    • /
    • 제9권1호
    • /
    • pp.89-102
    • /
    • 2019
  • Collagen can be used in building artificial skin replacements for treatment of burns and towards the reconstruction of bone as well as researching cell behavior and cellular interaction. The strength of collagen in connective tissue rests on the characteristics of collagen fibers. 3D confocal imaging of collagen fibers enables the characterization of their spatial distribution as related to their function. However, the image stacks acquired with confocal laser-scanning microscope does not clearly show the collagen architecture in 3D. Therefore, we developed a new method to reconstruct, visualize and characterize collagen fibers from fluorescence confocal images. First, we exploit the tensor voting framework to extract sparse reliable information about collagen structure in a 3D image and therefore denoise and filter the acquired image stack. We then propose to segment the collagen fibers by defining an energy term based on the Hessian matrix. This energy term is minimized by a min cut-max flow algorithm that allows adaptive regularization. We demonstrate the efficacy of our methods by visualizing reconstructed collagen from specific 3D image stack.

Quantification of Fibers through Automatic Fiber Reconstruction from 3D Fluorescence Confocal Images

  • Park, Doyoung
    • 한국정보기술학회 영문논문지
    • /
    • 제10권1호
    • /
    • pp.25-36
    • /
    • 2020
  • Motivation: Fibers as the extracellular filamentous structures determine the shape of the cytoskeletal structures. Their characterization and reconstruction from a 3D cellular image represent very useful quantitative information at the cellular level. In this paper, we presented a novel automatic method to extract fiber diameter distribution through a pipeline to reconstruct fibers from 3D fluorescence confocal images. The pipeline is composed of four steps: segmentation, skeletonization, template fitting and fiber tracking. Segmentation of fiber is achieved by defining an energy based on tensor voting framework. After skeletonizing segmented fibers, we fit a template for each seed point. Then, the fiber tracking step reconstructs fibers by finding the best match of the next fiber segment from the previous template. Thus, we define a fiber as a set of templates, based on which we calculate a diameter distribution of fibers.

Real-time Fluorescence Lifetime Imaging Microscopy Implementation by Analog Mean-Delay Method through Parallel Data Processing

  • Kim, Jayul;Ryu, Jiheun;Gweon, Daegab
    • Applied Microscopy
    • /
    • 제46권1호
    • /
    • pp.6-13
    • /
    • 2016
  • Fluorescence lifetime imaging microscopy (FLIM) has been considered an effective technique to investigate chemical properties of the specimens, especially of biological samples. Despite of this advantageous trait, researchers in this field have had difficulties applying FLIM to their systems because acquiring an image using FLIM consumes too much time. Although analog mean-delay (AMD) method was introduced to enhance the imaging speed of commonly used FLIM based on time-correlated single photon counting (TCSPC), a real-time image reconstruction using AMD method has not been implemented due to its data processing obstacles. In this paper, we introduce a real-time image restoration of AMD-FLIM through fast parallel data processing by using Threading Building Blocks (TBB; Intel) and octa-core processor (i7-5960x; Intel). Frame rate of 3.8 frames per second was achieved in $1,024{\times}1,024$ resolution with over 4 million lifetime determinations per second and measurement error within 10%. This image acquisition speed is 184 times faster than that of single-channel TCSPC and 9.2 times faster than that of 8-channel TCSPC (state-of-art photon counting rate of 80 million counts per second) with the same lifetime accuracy of 10% and the same pixel resolution.

Confocal laser scanning microscopy image를 이용한 UASB granule의 메탄 생성 능력 측정

  • 이유진;김효섭;안영희;박성훈
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 춘계학술발표대회
    • /
    • pp.365-369
    • /
    • 2000
  • 반응기의 performance를 결정하는 중요한 요소는 methane 생성균의 활성을 측정하는 것이다. Methanogen의 활성을 측정하는 방법으로 SMA가 유일하게 사용되고 있다. 따라서 본 연구에서는 methanogen의 활성을 측정하는 다른 대안으로 CLSM image의 정량 분석 방법을 확립하였다. CLSM의 결과는 약 5시간 안에 얻을 수 있을 뿐만 아니라, 분자 생물학적인 기술을 많이 요하지 않는다. 또한, sludge내부의 상태와 methanogen의 분포정도를 사진으로 볼 수 있는 장점이 있다. 따라서 SMA와 함께 CLSM image 정량 분석은 UASB반응기의 start-up 동안의 methanogen의 활성을 측정하기 위한 유용한 방법으로 제안할 수 있다.

  • PDF

Quantitative Image Analysis of Fluorescence Image Stacks: Application to Cytoskeletal Proteins Organization in Tissue Engineering Constructs

  • Park, Doyoung
    • 한국정보기술학회 영문논문지
    • /
    • 제9권1호
    • /
    • pp.103-113
    • /
    • 2019
  • Motivation: Polymerized actin-based cytoskeletal structures are crucial in shape, dynamics, and resilience of a cell. For example, dynamical actin-containing ruffles are located at leading edges of cells and have a significant impact on cell motility. Other filamentous actin (F-actin) bundles, called stress fibers, are essential in cell attachment and detachment. For this reason, their mechanistic understanding provides crucial information to solve practical problems related to cell interactions with materials in tissue engineering. Detecting and counting actin-based structures in a cellular ensemble is a fundamental first step. In this research, we suggest a new method to characterize F-actin wrapping fibers from confocal fluorescence image stacks. As fluorescently labeled F-actin often envelope the fibers, we first propose to segment these fibers by diminishing an energy based on maximum flow and minimum cut algorithm. The actual actin is detected through the use of bilateral filtering followed by a thresholding step. Later, concave actin bundles are detected through a graph-based procedure that actually determines if the considered actin filament is enclosing the fiber.

상아세관의 주행방향에 따른 상아질 접착제의 침투양상에 대한 공초점레이저주사현미경 연구 (EFFECT OF DENTINAL TUBULES ORIENTATION ON PENETRATION PATTERN OF DENTIN ADHESIVES USING CONFOCAL LASER SCANNING MICROSCOPY)

  • 김동준;황윤찬;김선호;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제28권5호
    • /
    • pp.392-401
    • /
    • 2003
  • The purpose of this study was to evaluate the penetration pattern of dentin adhesives according to the orientation of dentinal tubules with confocal laser scanning microscopy. Specimens having perpendicular. parallel and oblique surface to dentinal tubules were fabricated. The primer of dentin adhesives (ALL $BOND^{\circledR}{\;}2,{\;}CLEARFIL^{TM}$ SE BOND and PQ1) was mixed with fluorescent material. rhodamine B isothio-cyanate (Aldrich Cherm. CO., Milw., USA), It was applied to the specimens according to the instructions of manufactures. The specimens were covered with composite resin (Estelite, shade A2) and then cut to a thickness of 500$\mu\textrm{m}$ with low speed saw (Isomet^{TM}, Buehler. USA). The adhesive pattern of dentin adhesives were observed by fluorescence image using confocal laser scanning microscopy. The results were as follows. 1. For the groups with tubules perpendicular to bonded surface. funnel shape of resin tag was observed in all specimen. However. resin tags were more prominent in phosphoric acid etching system (ALL $BOND^{\circledR}$ 2 and PQ1) than self etching system ($CLEARFIL^{TM}$ SE BOND). 2. For the groups with tubules parallel to bonded surface. rhodamine-labeled primer penetrated into peritubular dentin parallel to the orientation of dentinal tubules. But rhodamine-labeled primer of PQ1 diffused more radially into surrounding intertubular dentin than other dentin adhesive systems. 3. For the groups with tubules oblique to bonded surface. resin tags appeared irregular and discontinuous. But they penetrated deeper into dentinal tubules than other groups.

3D Light-Sheet Fluorescence Microscopy of Cranial Neurons and Vasculature during Zebrafish Embryogenesis

  • Park, Ok Kyu;Kwak, Jina;Jung, Yoo Jung;Kim, Young Ho;Hong, Hyun-Seok;Hwang, Byung Joon;Kwon, Seung-Hae;Kee, Yun
    • Molecules and Cells
    • /
    • 제38권11호
    • /
    • pp.975-981
    • /
    • 2015
  • Precise 3D spatial mapping of cells and their connections within living tissues is required to fully understand developmental processes and neural activities. Zebrafish embryos are relatively small and optically transparent, making them the vertebrate model of choice for live in vivo imaging. However, embryonic brains cannot be imaged in their entirety by confocal or two-photon microscopy due to limitations in optical range and scanning speed. Here, we use light-sheet fluorescence microscopy to overcome these limitations and image the entire head of live transgenic zebrafish embryos. We simultaneously imaged cranial neurons and blood vessels during embryogenesis, generating comprehensive 3D maps that provide insight into the coordinated morphogenesis of the nervous system and vasculature during early development. In addition, blood cells circulating through the entire head, vagal and cardiac vasculature were also visualized at high resolution in a 3D movie. These data provide the foundation for the construction of a complete 4D atlas of zebrafish embryogenesis and neural activity.

Thermosensitive Block Copolymers Consisting of Poly(N-isopropylacrylamide) and Star Shape Oligo(ethylene oxide)

  • Lee, Seung-Cheol;Chang, Ji-Young
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권7호
    • /
    • pp.1521-1525
    • /
    • 2009
  • Thermosensitive block copolymers of ethylene oxide and N-isopropylacrylamide (NIPAM) were synthesized. A five armed star shape oligo(ethylene oxide) initiator with a cyclotriphosphazene core was prepared and used for the atom transfer radical polymerization (ATRP) of NIPAM. The lower critical solution temperatures (LCSTs) of the copolymers were 36 to 46 ${^{\circ}C}$, higher than that of PNIPAM (32 ${^{\circ}C}$), depending on their molecular weights. The copolymers were soluble in water below the LCSTs but formed micelles above the LCSTs. The thermosensitive micellization behaviors of the polymers were investigated by fluorescence spectroscopy. With increasing the temperature of an aqueous solution of P2 and pyrene above the LCST, the peak of 333 nm red-shifted to appear around 339 nm and its intensity increased significantly, indicating the micelle formation. The transfer of pyrene into the micelles was also confirmed by a confocal laser scanning microscope. The fluorescence image obtained from P2 in an aqueous pyrene solution exhibited a green emission resulting from the pyrene transferred into the micelles. Salt effects on the solubility of the copolymers in an aqueous solution were investigated. The LCST of P2 decreased sharply as the concentration of sodium chloride increased, while decreased slowly with potassium chloride.

Digital Imaging Fiber-Optic Trans-Illumination과 Laser Fluorescence를 이용한 법랑질 우식증의 조기 진단에 관한 비교 연구 (COMPARATIVE STUDY ON THE EARLY DETECTION OF ENAMEL LESIONS USING DIFOTI AND LASER FLUORESCENCE)

  • 맹명호;김승오;김종수
    • 대한소아치과학회지
    • /
    • 제33권2호
    • /
    • pp.207-220
    • /
    • 2006
  • 새로 개발된 조기 진단 장비들로는 laser fluorescence device(LFD), 초음파 진단 시스템, confocal laser scanning microscopy(CLSM), quantitative light-induced fluorescence(QLF) 시스템 그리고 digital imaging fiber-optic trans-illumination(DIFOTI) 시스템 등이 있다. 본 연구는 임상에서 사용되고 있는 DIFOTI시스템과 LFD를 이용하여 유치 교환 시기에 있는 환아 21명, 25개의 유치를 대상으로 각 치아당 $1{\sim}3$점을 선정하여 구강내에서 초기 우식법랑질에 대한 DIFOTI 이미지 촬영 결과와 LFD 계측값을 3회 측정하고 그 평균을 대표값으로 한 결과를 CLSM과 비교하여 진단 능력을 평가하였다. 실험실 연구에서는 인공우식 용액을 이용하여 수거된 40개의 유치를 협설면에 $2{\times}3mm$ 크기의 창을 형성하고 4, 8, 12, 16일간 탈회시키면서 그 변화를 DIFOTI 시스템과 LFD를 이용하여 측정하고 이를 CLSM과 비교 분석하여 다음과 같은 결론을 얻었다. 1. 구강내에서 촬영된 DIFOTI의 민감도는 88.2%이었고, 특이도는 76.9%이었다. 2. 구강내에서 측정된 LDD의 민감도는 76.5%이었고, 특이도는 69.2%이었다. 3. 실험실 연구에서 유치 법랑질의 탈회 기간에 따른 DIFOTI 광투과율의 회귀 분석한 결과, 탈회 시간에 따라 광투과율은 감소하였다(r=-0.96, p<0.05). 4. 실험실에서 탈회 기간에 따른 LFD의 측정값의 회귀 분석 결과 통계적 유의성을 보이지 않았다(p>0.05). 5. DIFOTI 이미지의 광투과율과 CLMS의 병소 깊이에 대한 상관 계수는 -0.688이었으나(p<0.05), LFD의 측정값은 유의성을 보이지 않았다.

  • PDF