• Title/Summary/Keyword: Condition(B)

Search Result 5,018, Processing Time 0.032 seconds

Stability Analysis of Toppling Failure in Rock Slopes (암반사면의 전도파괴에 대한 안정해석)

  • 이명재;이인모
    • Geotechnical Engineering
    • /
    • v.14 no.2
    • /
    • pp.55-66
    • /
    • 1998
  • The purpose of this paper is to formulate and apply the stability analysis of toppling failure by considering the variation of discontinuity characteristics, slope geometry, and loading conditions. The stability condition on toppling failure of rock slope is mainly iuluenced by the dip angle $\alpha_B$ and H/t ratio. In order to check toppling failures in design, the stability charts composed of dip angle $\alpha_B$ versus H/t ratio have been constructed in the paper. In general, smaller dip angle $\alpha_B$ and smaller dip angle $\alpha_B$ and smaller H/T ratio give safer condition. The suggested curves change rapidly at the chitical point around the sone, H/t=4~6. The stable zone in stability charles becomes smaller due to step angle $\data$.

  • PDF

Indirect Adaptive Fuzzy Observer Design

  • Yang, Jong-Kun;Hyun, Chang-Ho;Kim, Jae-Hun;Kim, Eun-Tai;Park, Mi-Gnon
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2004.10a
    • /
    • pp.192-196
    • /
    • 2004
  • This paper proposes an alternative observation scheme, T-S fuzzy model based indirect adaptive fuzzy observer. Nonlinear systems are represented by fuzzy models since fuzzy logic systems are universal approximators. In order to estimate the unmeasurable states of a given nonlinear system, T-S fuzzy modeling method is applied to get the dynamics of an observation system. T-S fuzzy system uses the linear combination of the input state variables and the modeling applications of them to various kinds of nonlinear systems can be found. The adaptive fuzzy scheme estimates the parameters comprising the fuzzy model representing the observation system. The proposed indirect adaptive fuzzy observer based on T-S fuzzy model can cope with not only unknown states but also unknown parameters. In the process of deriving adaptive law, the Lyapunov theory and Lipchitz condition are used. To show the performance of the proposed observation method, it is applied to an inverted pendulum on a cart.

  • PDF

Indirect Adaptive Fuzzy Observer Design

  • Yang, Jong-Kun;Hyun, Chang-Ho;Kim, Jae-Hun;Kim, Eun-Tai;Park, Mignon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.14 no.7
    • /
    • pp.927-933
    • /
    • 2004
  • This paper proposes an alternative observation scheme, T-S fuzzy model based indirect adaptive fuzzy observer. Nonlinear systems are represented by fuzzy models since fuzzy logic systems are universal approximators. In order to estimate the unmeasurable states of a given nonlinear system, T-S fuzzy modeling method is applied to get the dynamics of an observation system. T-S fuzzy system uses the linear combination of the input state variables and the modeling applications of them to various kinds of nonlinear systems can be found. The adaptive fuzzy scheme estimates the parameters comprising the fuzzy model representing the observation system. The proposed indirect adaptive fuzzy observer based on T-S fuzzy model can cope with not only unknown states but also unknown parameters. In the process of deriving adaptive law, the Lyapunov theory and Lipchitz condition are used. To show the performance of the proposed observation method, it is applied to an inverted pendulum on a cart.

Application of Variational Method to the Elastic Foundation (변분법에 의한 탄성지반 해석)

  • Lee, Seung-Hyun;Han, Jin-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4642-4647
    • /
    • 2011
  • Solution for elastic foundation of plane strain state was derived by the application of variational method. Functions of the transverse distribution of the displacements for the analysis were chosen as linear functions. Loading conditions considered for the analysis were concentrated load and distributed load. Under the loading condition of the concentrated load, surface displacement was decreased drastically as the distance from the point of the loading increased. Under the loading condition of the distributed load, surface displacements were more uniformly distributed beneath the loading area when the ratio of the half of the loading width to the depth(B/H) of the compressible layer was greater. The surface displacement was more quickly converged from the edge of the loading area as the ratio(B/H) increased.

Aging Effect of Magnetic Properties in Amorphous $Fe_{78}B_{13}Si_9$ Alloy (비정질 $Fe_{78}B_{13}Si_9$ 합금의 자기적 특성의 경년 열화)

  • Kim, Ki-Uk;Min, Bog-Ki;Song, Jae-Sung;Hong, Jin-Wan;Cho, Hyun-Jin;Lee, Dong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1988.05a
    • /
    • pp.49-51
    • /
    • 1988
  • The heat treatment condition and aging behavior of melt spun amorphous $Fe_{78}B_{13}Si_9$(Metglas 26058-2) were studied with investigating its magnetic properties, i.e., Br, $B_l$, Hc. The optimum heat treatment condition was $400^{\circ}C$, 1 hour under the external field of 200e, and aging was due to the surface oxidation and the appearance of local CSRO (chemical short lange order) with time and temperature. In addition. we investigated the effects of the thickness of the amorphous ribbons on the magnetic properties and aging effect of them.

  • PDF

Development of Inspection Methodology for a Nuclear Piping Wall Thinning Caused by Erosion Using Ultrasonic B-Scan Measurement Device (B-Scan 초음파 측정장비를 이용한 원전 배관 침식손상 검사법 개발)

  • Lee, Dae Young;Suh, Heok Ki;Hwang, Kyeong Mo
    • Corrosion Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.89-95
    • /
    • 2012
  • U.S. Electric Power Research Institute (EPRI) has developed CHECWORKS program and applied it to power plant piping lines since some lines were ruptured by flow-accelerated corrosion (FAC) in 1978. Nowadays the CHECWORKS program has been used to manage pipe wall thinning phenomena caused by FAC. However, various erosion mechanisms can occur in carbon-steel piping. Most common forms of erosion are cavitation, flashing, liquid droplet impingement erosion (LDIE), and Solid Particle Erosion (SPE). Those erosion mechanisms cause pipe wall thinning, leaking, rupturing, and even result in unplanned shutdowns of utilities. Especially, in two phase condition, LDIE damages a wide scope of plant pipelines. Furthermore, LDIE is the major culprit to cause such as power runback by pipe leaking. This paper describes the methodologies that manage wall thinning and also predict LDIE wall thinning area. For this study, current properties of two-phase condition are investigated and LDIE areas are selected. The areas are checked by B-Scan method to detect the effect of wall thinning phenomena.

Design of the Shaped Cassegrain Antenna Considering the Excited Power Function (급전 함수를 고려한 수정곡면 캐서그레인 안테나 설계)

  • Kong, Ki-Bok;Kim, Jong-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.9
    • /
    • pp.908-914
    • /
    • 2013
  • A shaped Cassegrain antenna is designed from the condition of the same path length at the equi-phase surface by using the conservation of energy and Snell's law. In order to improve the phase error efficiency of aperture surface, the surface profile of the main and sub-reflectors is found to satisfy the power distribution and the equi-phase condition at the aperture surface. The sidelobe levels of 36.4 dB and 33.9 dB are achieved at the AZ and EL planes, respectively from numerical calculation by physical optics method at Ku band and the directivity of designed antenna is 10 percent greater than that of conventional antenna.

The Performance Comparison of The Harmonic Generators using Nonlinear Transmission Lines (비선형 전송선로를 이용한 고조파 발생기 성능 비교)

  • Park, Soonwoo;Kim, Hongjoon;Yoo, Hyoungsuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.8
    • /
    • pp.1212-1216
    • /
    • 2015
  • In this paper, we compared the performance of the Right Handed Nonlinear Transmission Line (RH-NLTL) and Left Handed Nonlinear Transmission Line (LH-NLTL) as a harmonic generator. For a performance comparison, we fabricated both a RH-NLTL and a LH-NLTL harmonic generator whose operational bandwidth is from 0.5 GHz to 1.5 GHz. Under the each condition for the RH-NLTL and the LH-NLTL to maximize second harmonic, the output power of the second harmonic was 9.33 dB lower than the input power for the RH-NLTL and 12.67 dB lower than the input power for the LH-NLTL. Under the each condition for the RH-NLTL and the LH-NLTL to maximize third harmonic, the output power of the third harmonic was 13.33 dB lower than the input power for the RH-NLTL and 14.83dB lower than the input power for the LH-NLTL. Also, we have observed that, generatlly, a RH-NLTL is useful in generating various multiple harmonics and a LH-NLTL is useful in generating a specific order of harmonic by adjusting a proper DC vias, input frequency and input power. These tendencies could be a good guideline to use NLTLs as a frequency multiplier.

Analysis of On-Line Partial Discharge in Air-Coolded Gas Turbine Generator (공랭식 가스터빈 발전기의 운전중 부분방전 분석)

  • Lee, Eun-Chun;Kong, Tae-Sik;Kim, Jae-Chul;Kim, Hee-Dong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.41-47
    • /
    • 2014
  • The on-line partial discharge (PD) in stator windings of air-cooled gas turbine (GT) generator (119.2MVA, 13.8kV) is measured and analyzed in this paper. This generator was designed by global vacuum pressure impregnation (VPI). The generator failed two times at top bar (16T) of phase B in the stator slot. Six epoxy-mica capacitors were installed in three phases of GT generator. On-line PD test was performed on GT generator using turbine generator analyzer (TGA). TGA showed that the normalized quantity number (NQN) and the PD magnitude($Q_m$) were high in phase B. Internal discharges were generated in phases A, B and C. The trend analysis of NQN and $Q_m$ value are obtained in order to monitor the insulation condition in GT generator stator windings. Phases A and C were in good condition. But phase B had deteriorated significantly

Feasibility of Long Term Feed and Bleed Operation For Total Loss of Feedwater Event

  • Kwon, Young-Min;Song, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.257-264
    • /
    • 1996
  • The conventional Equipment Environment Qualification (EEQ) envelope is developed based on the containment responses during the design basis events. The Safety Depressurization System (SDS) design without In-containment Refueling Water Storage Tank (IRWST) adopted in the Ulchin 3&4 challenges the conventional EEQ envelope during long term Feed and Bleed (F&B) operation due to the direct discharge of high mass and energy into the containment. Therefore, it is necessary to confirm that the containment pressure and temperature history during the long term F&B operation does not violate the conventional EEQ envelope. However, this subject has never been quantitatively assessed before. To investigate the success path of long term F&B operation this paper analyzes the thermal hydraulic response of the containment and Reactor Coolant System (RCS) until the completion of depressurization and cooldown of RCS into Shutdown Cooling System (SCS) entry condition. It is found that the SCS entry condition can be reached within 6 hours without violating the EEQ curve by proper operation of SDS valves, High Pressure Safety Injection (HPSI) pumps and active Containment Heat Removal System (CHRS). The suggested strategy not only demonstrates the feasibility of long term F&B operation but also can be utilized in the preparation of Emergency Procedure Guidelines (EPGs)

  • PDF