• 제목/요약/키워드: Condition(B)

검색결과 5,008건 처리시간 0.031초

복합섬유를 혼입한 초고강도 콘크리트의 폭렬 특성 평가 (Evaluation on Spalling Properties of Ultra High Strength Concrete with Combined Fiber)

  • 손명학;김규용;민충식;이태규;구경모;윤용상
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.209-210
    • /
    • 2011
  • This study is aimed to draw a optimum combined fiber mix condition to improve spalling resistance and flowability of ultra high-strength concrete. As a result, W/B 12.5% concrete specimens were prevented spalling with PE0.05+ PP0.1, PE0.05+NY0.1 and W/B 12.5% concrete specimens were prevented spalling with all of combined organic fiber mix condition. But There is no significant influence of steel fiber under 5% volume ratios to prevent spalling. In the scope of this study, we suggest that condition of optimum volume ratio PE0.05+NY0.1 is to improve spalling resistance, flowability and residual compressive strength.

  • PDF

진공 침탄로 내의 전열 해석 (Heat Transfer Analysis in the Vacuum Carburizing Furnace)

  • 이인섭;유홍선;김원배;양제복
    • 대한기계학회논문집B
    • /
    • 제27권7호
    • /
    • pp.877-882
    • /
    • 2003
  • The main objective of the present study is to analyze the heat transfer characteristics in the vacuum carburizing furnace. Local temperatures are measured at different locations in the self-fabricated furnace for various operating conditions using K-type thermocouples. In addition, the present study simulates the fluid flows and heat transfer in the vacuum carburizing furnace using a commercial package (Fluent V. 6.0), and compares the predictions of local temperatures with experimental data. The temperature and flow fields are predicted. It is found that the time taken for reaching the steady-state temperature under the vacuum pressure is shorter than that under the normal pressure condition. It means that the carburizing furnace under vacuum pressure condition is capable of saving the required energy more efficiently than the furnace under the normal pressure condition. Furthermore, the temperature variations predicted by the numerical simulations are in good agreement with experimental data.

VIABILITY FOR SEMILINEAR DIFFERENTIAL EQUATIONS OF RETARDED TYPE

  • Dong, Qixiang;Li, Gang
    • 대한수학회보
    • /
    • 제44권4호
    • /
    • pp.731-742
    • /
    • 2007
  • Let X be a Banach space, $A:D(A){\subset}X{\rightarrow}X$ the generator of a compact $C_0-semigroup\;S(t):X{\rightarrow}X,\;t{\geq}0$, D a locally closed subset in X, and $f:(a,b){\times}C([-q,0];X){\rightarrow}X$ a function of Caratheodory type. The main result of this paper is that a necessary and sufficient condition in order that D be a viable domain of the semi linear differential equation of retarded type $$u#(t)=Au(t)+f(t,u_t),\;t{\in}[t_0,\;t_0+T],{u_t}_0={\phi}{\in}C([-q,0];X)$$ is the tangency condition $$\limits_{h{\downarrow}0}^{lim\;inf\;h^{-1}d(S(h)v(0)+hf(t,v);D)=0}$$ for almost every $t{\in}(a,b)$ and every $v{\in}C([-q,0];X)\;with\;v(0){\in}D$.

다공성 재생기의 방향성을 고려한 왕복유동 수치해석 (Numerical analysis in oscillating flow considering orientation of porous media regenerator)

  • 양문흠;박상진;노승탁
    • 대한기계학회논문집B
    • /
    • 제21권12호
    • /
    • pp.1668-1678
    • /
    • 1997
  • Numerical analyses were performed to investigate the characteristics of regenerator in oscillating flow by using moving boundary method and Darcy model. In this work, periodic adiabatic boundary condition was suggested as the boundary condition of adiabatic part so that the effects of the thermal inertia of the wall could be considered. In carrying out numerical analyses, two models were applied and compared. One called isotropic model has the same thermal conductivity in radial and axial directions within a porous media. The other called aeolotropic model has different conductivity in each directions. Isotropic model could not show the advantage of energy reduction which needs to maintain constant wall temperature difference between heater and cooler. But aeolotropic model could simulate the reduction of energy consumption.

원심압축기 채널디퓨저 내부의 압력분포에 관한 연구 (A Study on Pressure Distributions in a Centrifugal Compressor Channel Diffuser)

  • 강정식;강신형
    • 대한기계학회논문집B
    • /
    • 제25권4호
    • /
    • pp.507-513
    • /
    • 2001
  • Time averaged pressure distributions in a high-speed centrifugal compressor channel diffuser at design and off-design flow rates are investigated. Pressure distributions from the impeller exit to the channel diffuser exit are measured for various flow rates from choke to near surge condition, and the effects of operating condition are discussed. The strong non-uniformity in the pressure distribution is obtained over the vaneless space and semi-vaneless space caused by the impeller-diffuser interaction. As the flow rate increases, flow separation near the throat, due to large incidence angle at the vane leading edge, increases aerodynamic blockage and reduces the aerodynamic flow area downstream. Thus the minimum pressure location occurs downstream of the geometric throat, and it is named as the aerodynamic throat. And at choke condition, normal shock occurs downstream of this aerodynamic throat. The variation in the location of the aerodynamic throat is discussed.

분류층 건식 석탄가스화기에서의 가스화 특성 (Gasification characteristics in an entrained flow coal gasifier)

  • 유영돈;윤용승;안달홍;박호영
    • 대한기계학회논문집B
    • /
    • 제21권12호
    • /
    • pp.1690-1700
    • /
    • 1997
  • Entrained coal gasification tests with Datong coal were performed to assess the influence of oxygen/coal ration and pressure. When gasification condition in oxygen/coal ratio has changed from 0.5 to 1.0, optimal gasification condition from low pressure runs was oxygen/coal ratio of approximately 0.9 where CO was produced about 40% and H, about 20%. Under the pressure condition of 12-14 atmospheres, optimal oxygen/coal ratio value was in the region of 0.6 where CO was produced about 55% and H2about 25%. From these results, it was found that the oxygen/ coal ratio for the maximum production of CO and H, was decreasing with the increase in gasifier pressure and also, with increasing oxygen content, carbon conversion was increased. For the Chinese Datong coal, cold gas efficiency was in the range of 40-80%.

In vitro Degradation of Saikosaponin-a in Physiological Condition

  • Sung, Chung-Ki
    • 생약학회지
    • /
    • 제20권2호
    • /
    • pp.128-130
    • /
    • 1989
  • In vitro degradation of saikosaponin-a in physiological condition was conducted. Saikosaponin-a in 0.1 N-HCl of 25% 1,4-dioxane was incubated at $37^{\circ}$ and the products were analyzed and the time course of degradation was observed. Saikosaponin-a(Sa) was transformed to $saikosaponin-b_1(Sb_1)$ and saikosaponin-g(Sg) in the course of time. Sa was decreased drastically and not detected after 6 hours. $Sb_1$0 and Sg was increased with the time. After 6 hours the ratio of $Sb_1$ and Sg was about 4:1 and was maintained for 24 hours.

  • PDF

SMART 연구로 주냉각재펌프의 검증시험 (Qualification Test of a Main Coolant Pump for SMART Pilot)

  • 박상진;윤의수;오형우
    • 대한기계학회논문집B
    • /
    • 제30권9호
    • /
    • pp.858-865
    • /
    • 2006
  • SMART Pilot is a multipurpose small capacity integral type reactor. Main coolant pump (MCP) of SMART Pilot is a canned-motor-type axial pump to circulate the primary coolant between nuclear fuel and steam generator in the primary system. The reactor is designed to operate under condition of $310^{\circ}C$ and 14.7MPa. Thus MCP has to be tested under same operating condition as reactor design condition to verify its performance and safety. In present wort a test apparatus to simulate real operating situations of the reactor has been designed and constructed to test MCP. And then functional tests, performance tests, and endurance tests have been carried out upon a prototype MCP. Canned motor characteristics, homologous head/torque curves, coast-down curves, NPSH curves and lift-time performance variations were obtained from the qualification test as well as hydraulic performance characteristics of MCP.

포화된 정규압밀 점성토에서 비배수 공극수압의 거동(II) - 점탄성 해석 모델 - (The Behavior of Undrained Pore Water Pressure in Normally Consolidated and Saturated Clay(II) - Visco Elastic Analysis Model -)

  • 임성훈
    • 한국농공학회지
    • /
    • 제45권4호
    • /
    • pp.137-143
    • /
    • 2003
  • The initial condition of $\Delta \sigma_3 \;=\; \Delta u$ is used for analyzing the time dependent behavior of ground. This is based on the concept that the coefficient of pore water B is the unity on the condition of saturation. but some measured consolidation data in the field showed that the pore water pressure was not dissipated as time elapsed but it was maintained constant value or it's dissipation rate was slower than that of the predicted. and so the measured data of pore water pressure was not consistent with that of settlement. In this study, the rheological model for the pore water pressure behavior on undrained condition was induced and compared with the experiment data of the literature. The result showed that the suggested model was consistent well with the result of experiment, but the suggested model could not explain the effect of the decrease of void ratio according to consolidation.

전산해석을 통한 고분자 전해질 연료전지 내 입구 가습조건의 영향에 관한 연구 (Numerical Study for the Effect of Inlet Humidity Condition at PEMFC Channel)

  • 이동율;;배중면
    • 대한기계학회논문집B
    • /
    • 제30권12호
    • /
    • pp.1228-1235
    • /
    • 2006
  • PEMFC(Proton Exchange Membrane Fuel Cell) is a low temperature fuel cell and has many probabilities of commercial use. However, water management is one of the serious technical problems for commercialization. It is necessary to understand the relationship between operation conditions and water behavior in PEMFC channel because it affects fuel cell performance. In this paper, the distribution of current density according to inlet humidity condition is mainly observed and discussed. If the anode inlet is well humidified, electro-osmotic drag is very active. For this reason, current density is very high at inlet side and the distribution is non-uniform.