• 제목/요약/키워드: Concrete-Filled Effect

검색결과 276건 처리시간 0.025초

Experimental study on concrete filled square hollow sections

  • Lam, Dennis;Williams, Christopher A.
    • Steel and Composite Structures
    • /
    • 제4권2호
    • /
    • pp.95-112
    • /
    • 2004
  • A series of tests was performed to consider the behaviour of short composite columns under axial compressive loading, covering a range of S275 and S355 grade steel square hollow section filled with normal and high strength concrete. The interaction between the steel and the concrete component is considered and the results show that concrete shrinkage has an effect on the axial strength of the column. Comparisons between Eurocode 4, ACI-318 and the Australian Standards with the findings of this research were made. Result showed the equation used by the ACI-318 and the proposed Australian Standards gave better predication for the axial capacity of concrete filled SHS columns than the Eurocode 4.

Monitoring degradation in concrete filled steel tubular sections using guided waves

  • Beena, Kumari;Shruti, Sharma;Sandeep, Sharma;Naveen, Kwatra
    • Smart Structures and Systems
    • /
    • 제19권4호
    • /
    • pp.371-382
    • /
    • 2017
  • Concrete filled steel tubes are extensively applied in engineering structures due to their resistance to high tensile and compressive load and convenience in construction. But one major flaw, their vulnerability to environmental attack, can severely reduce the strength and life of these structures. Degradation due to corrosion of steel confining the concrete is one of the major durability problems faced by civil engineers to maintain these structures. The problem accelerates as inner surface of steel tube is in contact with concrete which serves as electrolyte. If it remains unnoticed, it further accelerates and can be catastrophic. This paper discusses a non-destructive degradation monitoring technique for early detection corrosion in steel tubes in CFST members. Due to corrosion, damage in the form of debonding and pitting occurs in steel sections. Guided ultrasonic waves have been used as a feasible and attractive solution for the detection and monitoring of corrosion damages in CFST sections. Guided waves have been utilized to monitor the effect of notch and debond defects in concrete filled steel tubes simulating pitting and delamination of steel tubes from surrounding concrete caused by corrosion. Pulse transmission has been used to monitor the healthy and simulated damaged specimens. A methodology is developed and successfully applied for the monitoring of concrete filled steel tubular sections undergoing accelerated chloride corrosion. The ultrasonic signals efficiently narrate the state of steel tube undergoing corrosion.

CFT구조용 초고강도 콘크리트의 현장 적용을 위한 실험적 연구 (An Experimental Study on High Strength Concrete for Concrete Filled Steel Tube Column for Field Application)

  • 이장환;김영주;정광식;강태경;정근호;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.454-457
    • /
    • 2004
  • Due to social problems such as the increasing of land price and the expanding of city, buildings require more complex and bigger components and structure. However, the complex and massive building projects need new technology to solve effect of local buckling and the needs for more space. Hence, Concrete Filled Tube Steel (CFT), the tube steel to hold concrete during pouring and curing of concrete procedure, which helps to reduce local buckling and space, was developed. Most researches on CFT might not be focused on the characteristic of concrete 'filled in tube but structural analysis. However, it is the essential factor to increase the strength of concrete on CFT for having efficient results. Therefore, this paper will describe how to apply CFT into the construction site through examining High Strength Concrete $(800kg/cm^2)$, the strength of core, and bleeding during pouring strategy.

  • PDF

Effect of tube area on the behavior of concrete filled tubular columns

  • Gupta, P.K.;Verma, V.K.;Khaudhair, Ziyad A.;Singh, Heaven
    • Computers and Concrete
    • /
    • 제15권2호
    • /
    • pp.141-166
    • /
    • 2015
  • In the present study, a Finite Element Model has been developed and used to study the effect of diameter to wall thickness ratio (D/t) of steel tube filled with concrete under axial loading on its behavior and load carrying capacity. The model is verified by comparing its findings with available experimental results. Influence of thickness and area of steel tube on strength, ductility, confinement and failure mode shapes has been studied. Strength enhancement factors, load factor, confinement contribution, percentage of steel and ductility index are defined and introduced for the assessment. A parametric study by varying length and thickness of tube has been carried out. Diameter of tube kept constant and equals to 140 mm while thickness has been varied between 1 mm and 6 mm. Equations were developed to find out the ultimate load and confined concrete strength of concrete. Variation of lateral confining pressure along the length of concrete cylinder was obtained and found that it varies along the length. The increase in length of tubes has a minimal effect on strength of tube but it affects the failure mode shapes. The findings indicate that optimum use of materials can be achieved by deciding the thickness of steel tube. A better ductility index can be obtained with the use of higher thickness of tube.

A numerical study on shear response of concrete-filled stainless steel tubes

  • Sina Kazemzadeh Azad;Brian Uy
    • Steel and Composite Structures
    • /
    • 제48권5호
    • /
    • pp.507-530
    • /
    • 2023
  • The number of studies investigating the response of concrete-filled tubes (CFTs) under shear has been very limited in the literature. This lack of research has been traditionally reflected in international design standards as rather conservative shear strength predictions for CFTs. The dearth of research on the shear response is even more pronounced for the case of concrete-filled stainless steel tubes (CFSSTs). In line with this, the present study investigates the shear response of circular and square CFSSTs using advanced finite element (FE) analysis. A thorough review of the previous studies on the shear response of carbon steel CFTs is provided along with a summary of past experimental programmes as well as the developed and codified design methods. A comprehensive numerical study is then conducted considering a wide range of circular and square, austenitic and lean duplex CFSSTs with different concrete infills and shear span-to-depth ratios. The effect of the tail length on the shear response is investigated and the minimum required tail length for achieving full shear capacity is established. The simulations are also used to highlight the importance of the dilation of the concrete core in the shear response of concrete-filled tubes and its relationship with the utilised boundary conditions. Furthermore, the numerical results are compared in detail with the predictions of design approaches developed previously for carbon steel CFTs and their accuracy and applicability to the stainless steel counterpart are demonstrated and recommendations are made accordingly.

중심 축 하중을 받는 충전각형강관 합성기둥의 부착응력에 관한연구 (Experimental Study on Bond Stress of Concrete Filled Rectangular Steel Tubular Composite Column Subjected to Axial Load)

  • 이형석;박성무
    • 한국공간구조학회논문집
    • /
    • 제3권3호
    • /
    • pp.105-110
    • /
    • 2003
  • This paper is presented an experimental studies on bond stress between steel and concrete in concrete filled Rectangular steel tubes. In the actual building frames, vertical dead and live loads on beams are usually transferred to columns by beam-to-column connections. In case when concrete filled steel tubes are used as columns of an actual building frame which has a simple connection, shear forces in the beam ends are not directly transferred to the concrete core but directly to the steel tube. Provided that the bond effect between steel tube and concrete core should not be expected, none of the end shear in the beams would be transferred to the concrete core but only to the steel tube. Therefore, it is important to investigate the bond strength between steel tube and concrete core in the absence of shear connectors.

  • PDF

충전 각형강관 기둥의 내력 평가에 관한 연구 (A Study on the Strength of Concrete Filled Steel Tubular Column)

  • 안형준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권2호
    • /
    • pp.151-158
    • /
    • 2000
  • A study on the strength of steel tubular column filled with concrete under cocentrically compressed load is presented in this paper. This paper is structured as follows. The first section briefly discusses the M-N relationship formula derived for CFT, highlighting the additional moment effect. Next, the simple superposed method used to generate the strength formula of CFT loaded concentrically is described. In the final portion of this paper, the presented formula is compared to experimental data reported. The applicability of CFT strength formula presented here is limited somewhat by scope of concrete strength but can predict the strength of CFT simply and rapidly. The objective of this paper is to approach the strength of CFT theoretically and to examine the feasibility of presented formula.

  • PDF

콘크리트 충전 각형 강관기둥의 부착응력에 있어 shear-connector의 영향에 관한 실험적 연구 (A Experimental study about an effect of shear-connector at a bond stress in concrete filled rectangular tubular column)

  • 박성무;김성수;김원호;이형석;이경섭;송준근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.561-566
    • /
    • 2001
  • Load at steel beam column joints transfered by beam depend on bond strength between concrete and steel tube. But it is different to transmit a load efficiently in the established concrete filled steel tubular column. Therefore, shear-connector is demanded for transfering loads efficiently. An ascent of bond stress and a transmission of load after debonding are expected by a reinforcement of shear-connector

  • PDF

콘크리트 충전원형강관기둥의 부착응력에 있어 shear-connector의 영향에 관한 실험적 연구 (An experimental study about an effect of shear-connector at a bond stress in concrete filled circular steel tubular column)

  • 박성무;김성수;김원호;이형석;이우진;김경모
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.567-572
    • /
    • 2001
  • A transmission of load that is transmitted by beam in steel beam-column joint depends on bond strength between concrete and steel tube. But it is different to transmit a load efficiently in the established concrete filled steel tubular column. Therefore, shear-connector is demanded for a reinforcement about a transmission of load. An ascent of bond stress and a transmission of load after debonding are expected by a reinforcement of shear-connector.

  • PDF

일축 압축력을 받는 콘크리트충전 각형강관 단주의 구조적 거동 (Axial Compression of Stub Columns for Concrete-filled Square Steel Tubes)

  • 유영찬
    • 한국산학기술학회논문지
    • /
    • 제22권2호
    • /
    • pp.617-624
    • /
    • 2021
  • 각형강관 기둥에 콘크리트를 충전하여 사용하는 콘크리트충전 강관구조가 구조부재로 사용되면 기둥 부재의 내력과 변형 능력이 증가되어 높은 효율성을 가진 구조물 구현이 가능해 진다. 콘크리트충전 강관구조에 대한 국내의 설계 기준은 대한건축학회에서 2005년에 제정한 후, 2009년과 2016년에 각각 개정되었다. 연구 목적은 콘크리트충전 각형강관 단주를 대상으로 일축 압축실험을 실시하여 압축내력 및 변형능력에 주는 영향을 파악하고, 국내의 건축구조기준의 기준식을 검증하여 차후 수정 및 보완에 필요한 자료를 제공하는데 있다. 실험에서 강관은 냉간가공으로 제작된 각형강관을 사용하였고, 시험체는 강관의 폭두께비를 변수로 총 26개를 제작하여 중심 압축실험을 실시하였다. 실험결과 콘크리트충전 각형강관 단주의 압축내력과 변위관계 및 파괴모드를 얻었고, 실험결과를 분석하여 콘크리트의 충전효과와 폭두께비의 영향을 파악하였다. 충전된 콘크리트의 압축내력은 일축응력 상태보다 9%정도 증가하였는데, 이것은 차후 건축구조기준에 반영할 필요가 있다. 실험결과를 건축구조기준과 비교한 결과, 냉간가공된 각형강관의 경우 건축구조기준의 콤팩트단면 한계폭두께비 2.26은 다소 과대 평가하고 있기 때문에 수정이 필요하며, 보수적으로 보완한 계수 1.35로 제한하여 보다 더 안정적인 설계식을 제안하였다.