• 제목/요약/키워드: Concrete resistivity

검색결과 134건 처리시간 0.025초

Delamination and concrete quality assessment of concrete bridge decks using a fully autonomous RABIT platform

  • Gucunski, Nenad;Kee, Seong-Hoon;La, Hung;Basily, Basily;Maher, Ali
    • Structural Monitoring and Maintenance
    • /
    • 제2권1호
    • /
    • pp.19-34
    • /
    • 2015
  • One of the main causes of a limited use of nondestructive evaluation (NDE) technologies in bridge deck assessment is the speed of data collection and analysis. The paper describes development and implementation of the RABIT (Robotics Assisted Bridge Inspection Tool) for data collection using multiple NDE technologies. The system is designed to characterize three most common deterioration types in concrete bridge decks: rebar corrosion, delamination, and concrete degradation. It implements four NDE technologies: electrical resistivity (ER), impact echo (IE), ground-penetrating radar (GPR), and ultrasonic surface waves (USW) method. The technologies are used in a complementary way to enhance the interpretation. In addition, the system utilizes advanced vision to complement traditional visual inspection. Finally, the RABIT collects data at a significantly higher speed than it is done using traditional NDE equipment. The robotic system is complemented by an advanced data interpretation. The associated platform for the enhanced interpretation of condition assessment in concrete bridge decks utilizes data integration, fusion, and deterioration and defect visualization. This paper concentrates on the validation and field implementation of two NDE technologies. The first one is IE used in the delamination detection and characterization, while the second one is the USW method used in the assessment of concrete quality. The validation of performance of the two methods was conducted on a 9 m long and 3.6 m wide fabricated bridge structure with numerous artificial defects embedded in the deck.

흑연을 혼입한 전기전도 모르타르의 전기저항 및 발열특성에 관한 실험적 연구 (An Experimental Study on Electric Resistivity and Exothermic Property of Electrically Conductive Mortar using Amorphous Graphite)

  • 안홍진;김상헌;최수경
    • 한국건축시공학회지
    • /
    • 제16권3호
    • /
    • pp.247-255
    • /
    • 2016
  • 콘크리트에 전기전도성을 부여하여 확보한 발열 성능을 통해 주택의 난방이나 터널, 도로 또는 교량 상판에 눈녹이는 것이 가능하다. 본 연구는 전기전도 발열 콘크리트 개발을 위한 선행 연구로써 탄소계 전도성 재료인 흑연을 치환한 모르타르의 역학적 특성과 함께 전기저항 및 발열 특성에 대한 실험을 실시한 후 다음과 결과를 얻었다. 토상 흑연 치환율이 증가할수록 압축강도는 감소하는 것으로 나타났으나 전기 저항은 크게 낮아지는 것으로 나타났다. 발열특성을 보이기 위해서는 흑연의 혼입이 모르타르 전체 체적의 15%이상 이루어져야 하는 것으로 나타났다. 흑연의 혼입이 일정수준이상 이루어져 낮은 전기저항 및 발열특성을 확보한 경우에는 작용하는 전압과 발열량은 높은 상관관계를 가지며 전압의 제곱과 발열온도는 비례관계에 있는 것으로 나타났다.

Effect of silica fume and polyepoxide-based polymer on electrical resistivity, mechanical properties, and ultrasonic response of SCLC

  • Mazloom, Moosa;Allahabadi, Ali;Karamloo, Mohammad
    • Advances in concrete construction
    • /
    • 제5권6호
    • /
    • pp.587-611
    • /
    • 2017
  • This study focused on the influences regarding the use of polyepoxide-based polymer and silica fume (SF) on the fresh and hardened state properties of self-compacting lightweight concrete (SCLC) along with their impacts on electrical resistance and ultrasonic pulse velocity (UPV). To do so, two series of compositions each of which consists of twelve mixes, with water to binder (W/B) ratios of 0.35 and 0.4 were cast. Three different silica fume/binder ratios of 0, 5%, and 10% were considered along with four different polymer/binder ratios of 0, 5%, 10%, and 15%. Afterwards, the rupture modulus, tensile strength, 14-day, 28-day, and 90-day compressive strength, the UPV and the electrical resistance of the mixes were tested. The results indicated that although the use of polymer could enhance the passing and filling abilities, it could lead to a decrease of segregation resistance. In addition, the interaction of the SF and the polymeric contents enhanced the workability. However, the impacts regarding the use of polymeric contents on fresh state properties of SCLC were more prevalent than those regarding the use of SF. Besides the fresh state properties, the durability and mechanical properties of the mixes were affected due to the use of polymeric and SF contents. In other words, the use of the SF and the polymer enhanced the durability and mechanical properties of SCLC specimens.

베이지안 기법을 이용한 염해 콘크리트구조물의 내구성 예측 (Durability Prediction for Concrete Structures Exposed to Chloride Attack Using a Bayesian Approach)

  • 정현준;지광습;공정식;강진구
    • 콘크리트학회논문집
    • /
    • 제20권1호
    • /
    • pp.77-88
    • /
    • 2008
  • 본 논문에서는 염해를 받는 RC 구조물의 부식 내구성을 예측하기 위한 새로운 접근 방법을 제시한다. 이 예측 방법은, 현장 계측 데이터가 추가적으로 있을 때 베이스 정리 이론에 의하여 계속적으로 업데이팅을 할 수 있다. 모델 매개변수의 확률론적인 특성은 모델로 명백하게 고려된다. 염해 해석 모델의 절차를 간단하게 하기 위해서는, 내구성 한계의 확률은 라틴 하이퍼큐브 샘플 추출법에서 얻는 표본에서 결정된다. 이러한 새로운 방법은 중요한 콘크리트 구조물을 설계하기에 아주 유용하다. 그리고 모니터링을 통한 실 콘크리트구조물의 잔존수명을 예측 할 수 있다.

전기저항식 변형률 게이지를 이용한 콘크리트의 열팽창계수 측정법 (Coefficient of Thermal Expansion Measurement of Concrete using Electrical Resistance Strain Gauge)

  • 남정희;안덕순;김연복
    • 한국도로학회논문집
    • /
    • 제15권6호
    • /
    • pp.25-32
    • /
    • 2013
  • PURPOSES : The purpose of this study is to provide the method of how to measure the coefficient of thermal expansion of concrete using temperature compensation principle of electrical resistance strain gauge. METHODS : The gauge factor compensation method and thermal output(temperature-induced apparent strain) correction method of self-temperature compensation gauge were investigated. From the literature review, coefficient of thermal expansion measurement method based on the thermal output differential comparison between reference material(invar) and unknown material(concrete) was suggested. RESULTS : Thermal output is caused by two reasons; first the electrical resistivity of the grid conductor is changed by temperature variation and the second contribution is due to the differential thermal expansion between gauge and the test material. Invar was selected as a reference material and it's coefficient of thermal expansion was measured as $2.12{\times}10^{-6}m/m/^{\circ}C$. by KS M ISO 11359-2. The reliability of the suggested measurement method was evaluated by the thermal output measurement of invar and mild steel. Finally coefficient of thermal expansion of concrete material for pavement was successfully measured as $15.45{\times}10^{-6}m/m/^{\circ}C$. CONCLUSIONS : The coefficient of thermal expansion measurement method using thermal output differential between invar and unknown concrete material was evaluated by theoretical and experimental aspects. Based on the test results, the proposed method is considered to be reasonable to apply for coefficient of thermal expansion measurement.

고 흡수성 폴리머를 혼입한 콘크리트의 기초 물성 및 염화물 침투 저항성 평가 (Evaluation of Fundamental Properties and Chloride Penetration Resistance of Concrete using Superabsorbent Polymers)

  • 이찬규;김일순;최소영;양은익
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권2호
    • /
    • pp.50-59
    • /
    • 2020
  • 고 흡수성 폴리머(SAP)는 콘크리트 내부에서 물을 흡수하여 팽창하며 물을 방출하면서 수축한다. 이 과정을 통해 콘크리트는 내부 양생 효과를 얻을 수 있지만 팽창한 SAP가 차지하고 있던 공간은 공극으로 존재하게 된다. 따라서 본 연구에서는 SAP를 혼입한 콘크리트의 기초 물성 및 염화물 침투 저항성을 평가하여 SAP의 내부 양생과 공극에 의한 영향을 평가하였다. 또한 SAP에 의한 내부 양생 효과를 평가하기 위해 양생 조건을 수중 양생과 봉함 양생으로 구분하여 실시하였다. 실험 결과, 수중 양생의 압축강도는 혼입율에 따라 큰 차이가 없었으며, 봉함 양생의 경우에는 SAP의 혼입율이 증가함에 따라 압축 강도가 증가하는 경향을 나타냈다. 봉함 양생의 경우 내부 양생 효과가 압축 강도 증가에 영향을 준 것으로 판단된다. 염화물 확산계수 측정 결과, SAP의 혼입율 증가에 따라 확산계수가 감소하는 경향을 나타냈으며, 특히 봉함 양생은 내부 양생 효과로 인해 수화 반응이 촉진되어 염화물 침투 저항성이 더욱 개선된 것으로 판단된다. 양생 조건이 다른 경우 표면 전기저항을 이용해 염화물 침투 저항성을 평가하는 것은 부적절한 것으로 판단된다.

하천제방의 안전성 평가기법 연구 (A Study on Assessment Techniques of Levee Safety)

  • 윤종렬;김진만;최봉혁
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2005년도 공동학술대회 논문집
    • /
    • pp.111-116
    • /
    • 2005
  • 시트파일과 그라우팅 차수벽의 차수효과를 비교 판정하고 제방하부에서 발생하는 파이핑 현상을 감지하기 위하여 합천군의 덕인2제를 대상으로 갈수기와 우수기에 걸쳐 2차원 및 3차원 전기비저항탐사를 실시하였다. 자료의 해석결과 2차원이나 3차원탐사 모두 시트 파일과 일반 그라우팅 차수벽의 경계부나 육안으로 관찰된 파이핑 발생지점을 비교적 정확하게 탐지하였다. 또한 제방붕괴의 주요원인중 하나인 배수통문 배면의 공동을 조사하기 위하여 GPR탐사를 실시하였으나 구조물에 배근된 철근의 영향으로 만족할 만한 자료를 얻을 수 없었다. 배수통문 구조물의 특성상 여타 지구물리탐사법의 적용이 어려우므로 본 연구에서는 통문 하부 공동의 연결성을 평가할 수 있는 수리응답시험을 제안하였다.

  • PDF

비접지식 전기비저항 탐사 - 적용성과 한계 (Capacitively-coupled Resistivity Method - Applicability and Limitation)

  • 이성곤;조성준;송윤호;정승환
    • 지구물리와물리탐사
    • /
    • 제5권1호
    • /
    • pp.23-32
    • /
    • 2002
  • 비접지식 전기비저항 탐사는 땅에 접지전극을 설치하기 어려운 곳에서 전기비저항 탐사를 수행할 수 있는 방법으로 국내에서도 관심이 높아지고 있는 방법이다. 이 방법의 기본원리는 땅과 송수신 안테나의 용량결합(capacitive coupling)에 의하여 지하로 전류를 주입하고 이에 의한 전위차를 측정하여 자료를 획득하는 것이다. 본 연구에서는 쌍극자 및 단극 형태의 송수신 안테나를 일렬로 배치하는 방사 배열(radial array)에 대한 기하학적 상수를 유도하였다. 또한, 기존의 접지식 전기비저항 해석 알고리듬을 이용하여 비접지식 전기비저항 자료를 해석하기 위한 자료 전처리 및 변환 과정을 제시하였다. 즉, 획득된 탐사 자료를 기하학적 상수를 이용하여 일단 겉보기 비저항으로 변환한 후 쌍극자 배열이나 변형된 쌍극자 배열 자료로 보간 혹은 재샘플링함으로써 기존의 접지식 전기비저항 역산 알고리듬을 이용하여 해석하였는데, 동일 측선에서 수행한 접지식 및 비접지식 탐사 자료와 비교하여 그 타당성을 검증하였다. 비접지식 전기비저항 탐사법은 전류를 많이 주입할 수 없는 기기 상의 단점을 갖고 있음을 알 수 있었는데, 특히 전기비저항이 낮은 곳이나, 전기적 잡음이 심한 곳, 그리고 송수신 안테나의 접촉이 좋지 않은 지역에 적용함에 있어 세심한 주의가 요구된다. 그러나, 송수신 안테나를 일렬로 배열하여 견인함으로써 연속적으로 탐사 자료를 획득할 수 있고 전극 설치가 불가능한 지역에서 전기비저항 탐사를 수행할 수 있으므로, 신속하게 지하 천부에 대한 전기비저항 분포를 알고자 할 때 유용하게 쓰일 것으로 생각된다.

강섬유 혼입량이 철근 부식저항성능에 미치는 영향 (Influence of steel fiber contents on corrosion resistance of steel reinforcement)

  • 김성도;문도영;이규필
    • 한국터널지하공간학회 논문집
    • /
    • 제17권3호
    • /
    • pp.283-293
    • /
    • 2015
  • 본 연구에서는 강섬유보강콘크리트의 부식저항성능을 규명하기 위한 촉진염소이온확산시험과 표면전기저항시험을 수행하였다. 또한 배합평가를 위한 기초시험으로서 굳지 않은 콘크리트 공기량, 일축압축강도, 굳은 콘크리트의 흡습시험을 수행하였다. 실험변수는 두 종류의 물-시멘트비(0.44, 0.50)와 세 개의 강섬유 혼입량(0.25%, 0.5%, 1%)으로 선정하였다. 주목할 것은 모든 타설시 콘크리트의 다짐량은 동일하게 하였다. 시험결과, 동일한 작업량으로 다짐이 되었을 때, 물-시멘트비에 상관없이 두배합 모두에서 강섬유 혼입률이 증가함에 따라 부식저항성능이 감소하는 것으로 확인되었다. 그러나, 동일한 강섬유 혼입비에 대하여 배합의 물-시멘트비가 낮은 콘크리트의 부식저항성능이 우수한 것으로 나타났다. 따라서, 강섬유보강콘크리트의 타설시 유동성의 확보와 충분한 다짐이 염소이온침투저항성능을 확보하기 위하여 매우 중요하다고 판단된다.

TEM법에 의한 모르타르 중의 철근 부식 측정에 관한 연구 (A Study on the Measurement of Steel Corrosion in Mortar by TEM Method)

  • 이상호;한정섭
    • 한국해양공학회지
    • /
    • 제20권2호
    • /
    • pp.59-65
    • /
    • 2006
  • Steel, as a reinforcing mechanism in concrete, provides the tensile strength that is lacking in concrete, alone, and the high alkaline environment (pH 12.5) in concrete offers satisfactory protection against most corrosion of the steel. However, the corrosion of reinforcing steel in concrete can occur by chloride attack or carbonation, and it can cause a loss of integrity a section and concrete failure through cracking and spalling. In this study, a transient electro magnetic method (TEM) of a nondestructive technique is adapted to study the measuring method of steel corrosion in mortar. The sensor was made of an enameled wire, with a diameter of 0.25mm and anacril. He sensor configuration used was a coincident loop type. The secondary electro motive force (2nd EMF) was measured with SIROTEMIII, which equipped the accelerator. The accelerator allowsthe transmitter to turn off approximately $10\sim15$ times faster than normal. The high-resolution time series, used for very shallow or a high resistivity investigation was selected. After steels were corroded by the salt spray, during 4, 8, 15 and 25 days, they were embedded in mortar. The content results acquired in this study are as follows. The variation of the secondary electro motive force (2nd EMF) was shown by the change of steel surface with different corrosion time steel. It was confirmed that measurement of steel corrosion in mortar by a transient electro-magnetic method (TEM) can be possible.