• Title/Summary/Keyword: Concentration variation

Search Result 2,466, Processing Time 0.036 seconds

Anomaly Test for Ozone Concentration Data from National Air Monitoring Stations (오존 자동측정망 자료 중의 이상치 점검)

  • 김영성
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.2
    • /
    • pp.139-150
    • /
    • 1999
  • The ozone concentrations measured at the National Air Monitoring Stations between 1990 and 1995 were reviewed to detect any anomalies in the measurements. By screening the cases, in which variation of the ozone concentration from the previous measured value is greater than 75ppb, 125 station-days were identified as the test cases for the anomaly test. Historical and parallel consistencies of the measured concentrations were examined by plotting data for each test case. The detected anomalies can be classified into four categories; single outliers, anomalous variations during the startup period, baseline rises, and fluctuations in th diurnal variations. Anomalies were detected in as many as 80 cases among 125 test cases. Because of these anomalies, the number of hours exceeding 100ppb in the areas other than the Greater Seoul Area(GSA) could decrease from 157 to 107. Further studies for developing the methodology for eliminating the abnormal monitoring data are warranted for the data from the National Air Monitoring Stations are official to the both inside and outside of the country.

  • PDF

Stress and strain analysis of functionally graded plates with circular cutout

  • Dhiraj, Vikash Singh;Jadvani, Nandit;Kalita, Kanak
    • Advances in materials Research
    • /
    • v.5 no.2
    • /
    • pp.81-92
    • /
    • 2016
  • Stress concentration is an interesting and essential field of study, as it is the prime cause of failure of structural parts under static load. In the current paper, stress and strain concentration factors in unidirectional functionally graded (UDFGM) plate with central circular cutout are predicted by carrying out a finite element study on ANSYS APDL platform. The present study aims to bridge the lacuna in the understandings of stress analysis in perforated functionally graded plates. It is found that the material variation parameter is an important criterion while designing a perforated UDFGM plate. By selecting a proper material variation parameter and direction of material gradation, the stress and strain concentrations can be significantly reduced.

Flow of casson nanofluid along permeable exponentially stretching cylinder: Variation of mass concentration profile

  • Iqbal, Waheed;Jalil, Mudassar;Khadimallah, Mohamed A.;Hussain, Muzamal;Naeem, Muhammad N.;Naim, Abdullah F. Al;Mahmoud, S.R.;Tounsi, Abdelouahed
    • Steel and Composite Structures
    • /
    • v.38 no.1
    • /
    • pp.33-45
    • /
    • 2021
  • The Runge-Kutta method of 6th-order has been employed in this paper to analyze the flow of Casson nanofluid along permeable exponentially stretching cylinder. The modeled PDEs are changed into nonlinear ODEs through appropriate nonlinear transformations. The aim of the paper is to investigate the effects of different parameters such as Casson fluid parameter, slip parameter, suction parameter, Prandtl number, Lewis number, Brownian motion parameter, and thermophoresis parameter, with the variation of mass concentration profile. Numerical results are attained using a renowned numerical scheme shooting technique and for the authenticity of present methodlogy, the results are verified with earlier open text.

Time Series Observations of Atmospheric Radon Concentration in Seoul, Korea for an Analysis of Long-Range Transportation of Air Pollutants in the North-East Asia (동북아 오염물질 장거리이동 분석을 위한 서울시 대기 중 라돈농도의 시계열적 특성에 관한 연구)

  • Kim, Yoon-Shin;Lee, Cheol-Min;Kim, Ki-Youn;Jeon, Hyung-Jin;Kim, Jong-Cheol;Iida, Takao
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.4
    • /
    • pp.283-292
    • /
    • 2007
  • Atmospheric concentrations of radon had been continuously observed in Seoul, Korea since December 1999, as a tracer for long-range transport of air pollutants from China continent to Korea. In order to study radon as a tracer of long-range transport, it is important to know information about the atmospheric distribution and variation of radon concentration and its time variation. Atmospheric radon concentration are measured with electrostatic radon monitor(ERM) at Hanyang University located in Eastern area of Seoul. Air sample is taken into a vessel of ERM, and alpha particles emitted by radon daughters $Po^{218}$ are detected with ZnS(Ag) scintillation counter. Hourly mean concentrations and hourly alpha counts are recorded automatically. The major results obtained from time series observation of atmospheric radon were as follows : (1) The mean of airborne radon concentration in Seoul was found to be $7.62{\pm}4.11\;Bq/m^3$ during December $1999{\sim}January$ 2002. (2) The hourly variation of radon concentrations showed the highest in 8:00AM ($8.66{\pm}4.22\;Bq/m^3$) and the lowest in 3:00AM ($6.62{\pm}3.70\;Bq/m^3$) and 5:00AM ($6.62{\pm}3.39\;Bq/m^3$). (3) the seasonal variation of radon concentrations showed higher during winter-to-fall and lower during summer-to-spring. (4) Correlation between airborne radon concentration and the meteorological factors were -0.21 for temperature, 0.09 for humidity, -0.20 for wind speed, and 0.04 for pressure. (5) The mean difference of airborne radon concentration between Asian dust ($5.36{\pm}1.28\;Bq/m^3$) and non-Asian dust ($4.95{\pm}1.49\;Bq/m^3$) phenomenon was significant (p=0.08). We could identify time series distribution of radon concentration related meteorological factors. In addition, radon can be considered a good natural tracer of vertical dispersion and long-range transport.

Continuous Measurements of Size Separated Atmospheric Aerosol Number Concentration in Background Area (대기배경지역 에어로졸의 입경별 수농도 연속 측정)

  • Kang, Chang-Hee;Hu, Chul-Goo
    • Journal of Environmental Science International
    • /
    • v.21 no.4
    • /
    • pp.535-543
    • /
    • 2012
  • The aerosol number concentration have measured with an aerodynamic particle sizer spectrometer(APS) at Gosan site, which is known as background area in Korea, from January to September 2011. The temporal variation and the size distribution of aerosol number concentration have been investigated. The entire averaged aerosol number concentration in the size range 0.25~32.0 ${\mu}m$ is about 252 particles/$cm^3$. The number concentration in small size ranges(${\leq}0.5{\mu}m$) are very higher than those in large size ranges, such as, the number concentration in range of larger than 6.5 ${\mu}m$ are almost zero particles/$cm^3$. The contributions of the number concentration to PM10 and/or PM2.5 are about 34%, 20.1% and 20.4% in the size range 0.25~0.28 ${\mu}m$, 0.28~0.30 ${\mu}m$ and 0.30~0.35 ${\mu}m$, respectively, however, the contributions are below 1% in range of larger than 0.58 ${\mu}m$. The monthly variations in the number concentration in smaller size range(<1.0 ${\mu}m$) are evidently different from the variations in range of larger than 1.0 ${\mu}m$, but the variations are appeared similar patterns in smaller size range(<1.0 ${\mu}m$), also the variations in range of larger than 1.0 ${\mu}m$ are similar too. The diurnal variations in the number concentration for smaller particle(<1.0 ${\mu}m$) are not much, but the variations for larger particle are very evident. Size-fractioned aerosol number concentrations are dramatically decreased with increased particle size. The monthly differences in the size-fractioned number concentrations for smaller size range(<0.7 ${\mu}m$) are not observed, however, the remarkable monthly differences are observed for larger size than 0.7 ${\mu}m$.

Characteristics of Diurnal Variation of High PM2.5 Concentration by Spatio-Temporal Wind System in Busan, Korea (시·공간적 풍계에 따른 부산지역 고농도 PM2.5의 일변화 특성)

  • Kim, Bu-Kyung;Lee, Dong-In;Kim, Jeong-Chang;Lee, Jun-Ho
    • Journal of the Korean earth science society
    • /
    • v.33 no.6
    • /
    • pp.469-480
    • /
    • 2012
  • This study was to analyze the characteristics of diurnal variation of high $PM_{2.5}$ concentration, $PM_{2.5}/PM_{10}$ concentration ratio by spatio-temporal wind system (wind speed and wind direction) for high $PM_{2.5}$ concentration (over the 24 hr environmental standard of $PM_{2.5}$, $50{\mu}g/m^3$) in the air quality observation sites (Jangrimdong: Industrial area, Jwadong: Residential area) that were measured for 3 years (2005. 12. 1-2008. 11. 30) in Busan. The observation days of high $PM_{2.5}$ concentration were 182 at Jangrimdong and 27 at Jwadong. The seasonal diurnal variation of hourly mean of high $PM_{2.5}$ concentration and of $PM_{2.5}/PM_{10}$ concentration ratio showed a similar pattern that had higher variation at dawn, and night and in the morning than in the afternoon. Durning daytime in summer at Jwadong, the $PM_{2.5}/PM_{10}$ concentration ratio increased because a secondary particulate matter, which was created by photochemical reaction, decreased the coarse particles of $PM_{10}$ more than the fine particles of $PM_{2.5}$ concentrations in ocean condition. We did an analysis of spatio-temporal wind system (wind speed range and wind direction) in each time zone. The result showed that high $PM_{2.5}$ concentration at Jangrimdong occurred due to the congestion of pollutants emissions from the industrial complex in Jangrimdong area and the transportation of pollutants from places nearby Jangrimdong. It also showed that high $PM_{2.5}$ concentration occurred at Jwadong because of a number of local residential and commercial activities that caused the congestion of pollutants.

Spatio-temporal Variation of Intertidal Microphytobenthos in the Nakdong Estuary

  • Du, Guoying;Chung, Ik-Kyo
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.12 no.3
    • /
    • pp.186-190
    • /
    • 2007
  • The species composition and the biomass of intertidal microphytobenthos (MPB) were investigated at four sites in the Nakdong Estuary from Feb. to Dec. 2006. The chlorophyll (chl) ${\alpha}$ concentration showed a positive correlation with MPB abundance, and depth profiles showed similar patterns: high at the surface, rapidly decreasing within 4 cm from the surface, and slowly decreasing thereafter. A MANOVA analysis revealed that the chl ${\alpha}$ concentration varied significantly not only with depth, month, and site, but also with combinations of these factors. Among the four investigated sites, site D (Baekhabdeung) showed a seasonal biomass variation trend distinct from those of the other sites: higher in summer, decreased in autumn and with sustained low values until winter. As indicated, the other sites contrastingly showed low biomasses in summer, after which the biomasses continuously increased, with some variation among the sites. A cluster analysis of species composition indicated that sites near to each other and with similar sediment structures had closer similarities in the same seasons. The species of genus Amphora and Navicula were dominant at the four sites throughout the study period.

Diurnal Variations of Equilibrium Factor and Unattached fraction of Radon Progeny in Some Houses and Laboratories (가옥 및 실험실내 라돈평형인자, 비 흡착 라돈자손 비율의 일일 변동 특성)

  • Lee, Seung-Chan;Kim, Chang-Kyu;Lee, Dong-Myung;Kang, Hee-Dong
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.399-408
    • /
    • 2001
  • The variation characteristics of radon concentration, equilibrium equivalent concentration and equilibrium factor in some houses and laboratory buildings have been studied. The variation of equilibrium factor and the unattached fraction of radon progeny with ventilation condition have been also estimated. The averages of radon concentration, equilibrium equivalent concentration and equilibrium factor were $30\;Bq\;m^{-3},\;19.6\;Bq\;m^{-3}$ and 0.65 in seven houses, while $55.0\;Bq\;m^{-3},\;31.9\;Bq\;m^{-3}$ and 0.58 in three laboratory buildings, respectively. The diurnal variation of radon concentration, equilibrium equivalent concentration and equilibrium factor in indoor showed a typical pattern that the radon concentration, equilibrium equivalent concentration and equilibrium factor increased at dawn and morning, while decreased at midday and evening. While the equilibrium factor rate deceased in the indoor environment which was well ventilated, the unattached traction of radon progeny increased. The equilibrium factor was in proportion to air pressure and humidity of indoor, whereas in Inverse proportion to temperature.

  • PDF

Characteristics of Surface High Ozone Concentration on Pusan Coastal area, Korea (부산 해안지역의 고농도 오존 발생 특성에 관한 연구)

  • 전병일
    • Journal of Environmental Science International
    • /
    • v.9 no.4
    • /
    • pp.295-302
    • /
    • 2000
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone, nitrogen dioxide and meteorological data for 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was the highest at Dongsamdong in Spring(35.4ppb), at Kwangbokdong in Fall(25.1ppb) and the lowest Dongsamdong(22.2ppb) and Kwangbokdong(16.0ppb) in Winter. Relative standard deviation indicating clearness of observation site was 0.42 at Dongsamdong and 0.49 at Kwangbokdong that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong and Kwangbokdong showed maximum at 1500~1600LST and minimum 0700~0800LST that typical pattern of ozone concentration. In ozone episode period(Sept. 10~15, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface. During the episode days peak ozone concentrations are much higher than the normal values, wind speeds are always lower, and solar radiation is high with the exception of the September episode.

  • PDF

Concentration Variation of Atmospheric Radon and Gaseous Pollutants Related to the Airflow Transport Pathways during 2010~2015 (대기 라돈 및 기체상 오염물질의 기류 이동경로별 농도변화: 2010~2015년 측정)

  • Song, Jung-Min;Kim, Ki-Ju;Bu, Jun-Oh;Kim, Won-Hyung;Kang, Chang-Hee;Chambers, S.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.2
    • /
    • pp.321-330
    • /
    • 2018
  • Concentrations of the atmospheric radon and gaseous pollutants were measured at the Gosan site on Jeju Island from 2010 to 2015, in order to observe their time-series variation characteristics and examine the concentration change related to the airflow transport pathways. Based on the realtime monitoring of the atmospheric radon and gaseous pollutants, the daily mean concentrations of radon ($^{222}Rn$) and gaseous pollutants($SO_2$, CO, $O_3$, $NO_x$) were $2,400mBq\;m^{-3}$ and 1.3, 377.6, 41.1, 3.9 ppb, respectively. On monthly variations of radon, the mean concentration in October was the highest as $3,033mBq\;m^{-3}$, almost twice as that in July ($1,452mBq\;m^{-3}$). The diurnal variation of radon concentration shows bimodal curves at early morning (around 7 a.m.) and near midnight, whereas its lowest concentration was recorded at around 3 p.m. Several gaseous pollutants($SO_2$, CO, $NO_x$) showed a similar seasonal variation with radon concentration as high in winter and low in summer, whereas the $O_3$ concentrations had a bit different seasonal trend. According to the cluster back trajectory analysis, the frequencies of airflow pathways moving from continental North China, East China, Japan and the East Sea, the Korean Peninsula, and North Pacific Ocean routes were 36, 37, 10, 13, and 4%, respectively. When the airflow were moved to Jeju Island from continental China, the concentrations of radon and gaseous pollutants were relatively high. On the other hand, when the airflows were moved from North Pacific Ocean and East Sea, their concentrations were much lower than those from continental China.