• Title/Summary/Keyword: Concentration variation

검색결과 2,461건 처리시간 0.03초

한반도 11개 도시의 1995~2000년 PM10 농도 변화 경향 (Variations of the PM10 Concentrations Observed in Eleven Cities in South Korea between 1995 and 2000)

  • 진윤하;구해정;김봉만;김용표;박순웅
    • 한국대기환경학회지
    • /
    • 제19권2호
    • /
    • pp.231-245
    • /
    • 2003
  • Hourly PM$_{10}$ concentrations measured at 11 sites in Seoul and 10 sites in the large cities over South Korea for the period from March 1995 to February 2000 are analyzed to examine annual trend and monthly variations of the PM$_{10}$ concentrations. Further analysis has been carried out by using the one year data from March 1999 to February 2000 to see the seasonal variation, diurnal variation and weekly variation of the seasonally averaged PM$_{10}$ concentrations at each site. Weekly variations of the CO concentrations at the same sites for the same one year period are compared with that of the PM$_{10}$ concentration. There is no significant annual trend in the variation of the PM$_{10}$ concentration at all the sites analyzed. The seasonal and monthly mean concentrations show a minimum concentration in summer and alternative maximum concentration in spring and winter for most sites. The diurnal variation of the seasonally averaged mean PM$_{10}$ concentrations is strongly affected by traffic loads and meteorological conditions. The weekly variation of seasonal averaged concentrations of CO and PM$_{10}$ shows a high concentration for weekdays in spring, autumn and winter while high concentration for weekends in summer.nds in summer.

점탄성유체의 점성에 관한 실험적 연구 (An experimental study on the viscosity of visco-elastic fluids)

  • 김춘식;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제6권2호
    • /
    • pp.21-41
    • /
    • 1982
  • Viscosity, especially characteristic among various properties of visco-elastic fluids such as high polymer solutions, is affected mainly by temperature and concentration. Hence, it is important for fluid engineering to express, by some equations, how the fluid characteristics vary with the change of temperature and concentration and to analyze them to obtain consistent viscous characteristics. High polymer solutions, synthetic products of modern chemical industry, suggest many interesting investigations because they are typical visco-elastic materials. Experimentation was made to derive some useful fluid characteristic equations of SEPARAN-NP10 (polyacylamide) expressed by n (flow behavior index) and K' (consistency index) when it is given temperature and concentration variation. To measure viscosity, capillary viscometer was adopted and the range of experimentation is 0-2,000 P.P.M. in concentration and 15-55 .deg.C in temperature. The experimental results are summarized as follows: The flow behavior index n 1) has nearly constant results irrespective of temperature variation at same conentration and the results are shown in (Table. 4-4-3) 2) has following equation, regardless of temperature, for the variation of concentration. n=-1.0765*10$^{-4}$ P+0.9915 (P:P.P.M.) The consistency index K' 1) has different results for the variation of temperature at same concentration and the results are given in (Table.4-7-2) 2) has following equation for the variation of concentration at same temperature. log 10$^{4}$K' =6.4785*10$^{-4}$ P-1.0529 (P:P.P.M)

  • PDF

통계모형을 이용한 NO2 농도 예측에 관한 연구 (A study on Estimation of NO2 concentration by Statistical model)

  • 장난심
    • 한국환경과학회지
    • /
    • 제14권11호
    • /
    • pp.1049-1056
    • /
    • 2005
  • [ $NO_2$ ] concentration characteristics of Busan metropolitan city was analysed by statistical method using hourly $NO_2$ concentration data$(1998\~2000)$ collected from air quality monitoring sites of the metropolitan city. 4 representative regions were selected among air quality monitoring sites of Ministry of environment. Concentration data of $NO_2$, 5 air pollutants, and data collected at AWS was used. Both Stepwise Multiple Regression model and ARIMA model for prediction of $NO_2$ concentrations were adopted, and then their results were compared with observed concentration. While ARIMA model was useful for the prediction of daily variation of the concentration, it was not satisfactory for the prediction of both rapid variation and seasonal variation of the concentration. Multiple Regression model was better estimated than ARIMA model for prediction of $NO_2$ concentration.

Mn-Zn 페라이트 다결정의 조성에 따른 투자율의 변화 기구 (Origin of the Initial Permeability of Manganese-Zinc Ferrite Polycrytals)

  • 변순천;제해준;고경현;홍국선
    • 한국세라믹학회지
    • /
    • 제34권4호
    • /
    • pp.351-356
    • /
    • 1997
  • The origin of the variation of initial permeability in manganese-zinc ferrite polycrystals with a content of hematite was investigated. Initial permeability showed maximum with hematite content while there was no significant change in microstructure. Saturation magnetization increased with hematite content. So the variation of initial permeability was not explained on the basis of microstructural change or saturation magnetization. Temperature dependence of initial permeability revealed magnetocrystalline anisotropy was the origin of the variation of initial permeability. The change in magnetocrystalline anisotropy was ascribed to the variation in ferrous ion concentration. Therefore the variation of initial permeability in manganese-zinc ferrite polycrystals with a content of hematite was due to ferrous ion concentration via magnetocrystalline anisotropy.

  • PDF

부산 동삼동 지역의 대기오염농도 특성 (Characteristics of air pollution concentration on Dongsamdong, Pusan)

  • 전병일
    • 한국환경과학회지
    • /
    • 제8권3호
    • /
    • pp.281-286
    • /
    • 1999
  • This study was conduced to examine the monthly and seasonal variation of $SO_2$, TSP, $O_3$ concentration in Dongsamdong, Pusan coastal area. And the characteristics of air pollution of this area was compared to Kwangbokdong in Pusan and Taehadong in Ullungdo. Monthly mean concentration of $SO_2$ and TSP showed lower than Kwangbokdong, $O_3$ was higher than Kwangbokdong. In case of $SO_2$, seasonal variation of Dongsamdong was remarkabler thn Kwangbokdong and the concentration difference of early morning and daytime was higher than Kwangbokdong. Taehadong showed very lower concentration as background area. In case of TSP, Dongsamdong was lower concentration and smaller diurnal change than Kwangbokdong, Taehadong showed very lower concentration as backgound area. In case of $O_3$, Dongsamdong was 10ppb higher than Kwangbokdong at daytime maximum concentration, diurnal change of concentration was higher, too. In case of frequency distribution of concentration, $SO_2$, and TSP at Dongsamdong showed higher frequency in low concentration class and $O_3$ showed in high concentration class as compared with Kwangbokdong.

  • PDF

용존규소농도의 변화가 하천 부착조류의 밀도와 우점율에 미치는 영향에 관한 연구 (Effects on Density and Dominant rate of Periphyton by Variation of Dissolved Silicon Concentration)

  • 전경호
    • 상하수도학회지
    • /
    • 제23권6호
    • /
    • pp.703-709
    • /
    • 2009
  • In this study, an artificial-waterway experiment was conducted, using an attachment plate, on which algae from Nanakita river was placed, to examine the influence exerted by the variation of the dissolved-silicon concentration on the river periphyton. As a result, the variation of the dissolved-silicon concentration was found to exert an influence on the density of the adhesion diatom, and the mole ratio limits of the silica were about $Si/P{\fallingdotseq}182$ and $Si/N{\fallingdotseq}16.4$ or less. Moreover, the mole ratio that is necessary for proliferation was found to be larger than the value of the oceanic algae. Senedesmus sp. and Ankistrodesmus sp., which used silica in adhesion chlorophyta, received the influence of the silicon concentration strongly, and the twowere found to be superior in the environment, making silica a restriction factor.

$Fe_2O_3$ 미량 변화에 따른 Mn-Zn 페라이트 단결정의 전자기적 특성 (Electro-Magnetic Properties of Mn-Zn Ferrite Single Crystal with Small Variation of $Fe_2O_3$ Concentration)

  • 제해준;변순천;홍국선;장성도
    • 한국세라믹학회지
    • /
    • 제30권10호
    • /
    • pp.791-796
    • /
    • 1993
  • The electro-magnetic properties of the Mn-Zn ferrite single crystal with small variation of Fe2O3 concentration at the high permeability composition, 53mol% Fe2O3-28.5mol% MnO-18.5mol% ZnO, have been studied for the VCR magnetic head application. With the increase of the Fe2O3 concentration, the Fe2+ concentration increased, the specific resistivity decreased, the secondary maximum permeability shifted to the lower temperature, and the initial permeability decreased. It was concluded that the small variation of $\pm$0.5mol% Fe2O3 concentration greatly affected the electro-magnetic properties of Mn-Zn ferrite single crystals. At the composition of 53mol% Fe2O3, the initial permeability was comparatively high (650 at 5MHz) and its temperature dependence was small.

  • PDF

환기량 변화에 따른 실내공기질과 국소급기지수 특성 (Characteristics of Indoor Air Quality and Local Supply Index with a Variation of Supply ${\cdot}$ Exhaust Airflow rate)

  • 한창우;노광철;오명도
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.21-26
    • /
    • 2005
  • We performed the numerical analysis on the characteristics of indoor air quality and local supply index with a variation of supply · exhaust airflow rate. We analyzed the local supply index and carbon dioxide concentration at the room and breathing zone with respect to the variation of the supply · exhaust airflow rate. From the numerical results, we found that local supply index was affected but carbon dioxide concentration was hardly affected by the variation of the airflow rate in the room. And we also knew that carbon dioxide concentration was raised in despite of the increment of the supply airflow rate in the breathing zone. After this study it is necessary to analyze the local exhaust index when we evaluate the state of the ventilation in the room.

  • PDF

기상조건에 따른 부산지역 대기오염물질 농도변화와 예측에 관한 연구 (On the Prediction and Variation of Air Pollutants Concentration in Relation to the Meteorological Condition in Pusan Area)

  • 정영진;이동인
    • 한국대기환경학회지
    • /
    • 제14권3호
    • /
    • pp.177-190
    • /
    • 1998
  • The concentrations of air pollutants In large cities such as Pusan area have been increased every year due to the increasing of fuels consumption at factories and by vehicles as well as the gravitation of the population. In addition to the pollution sources, time and spatial variation of air pollutants concentration and meteorological factors have a great influence on the air pollution problem. Especially , its concentration is governed by wind direction, wind speed, precipitation, solar radiation, temperature, humidity and cloud amounts, etc. In this study, we have analyzed various data of meteorological factors using typical patterns of the air pressure to investigate how the concentration of air pollutants is varied with meteorological condition. Using the relationship between meteorological factors (air temperature, relative humidity, wind speed and solar radiation) and the concentration of air pollutants (SO2, O3) , experimental prediction formulas for their concentration were obtained. Therefore, these prediction formulas at each meteorological factor in a pressure pattern may be roughly used to predict the air pollutants concentration and contributed to estimate the variation of its value according to the weather condition in Pusan city.

  • PDF

대기 중에서 가스상 유기염소계 농약의 농도변화 패턴 (Variation Pattern of Gaseous Organochlorine Pesticides Concentration in Atmosphere)

  • 최민규;천만영
    • Environmental Analysis Health and Toxicology
    • /
    • 제22권2호통권57호
    • /
    • pp.111-118
    • /
    • 2007
  • This study was performed to measure gaseous Organochlorine Pesticides (OCPs : heptachlor epoxide, ${\alpha}/{\gamma}-chlordane$, trans-nonachlor, endosulfan, ${\gamma}-HCH$ and p, p'-DDE) concentration using PUF high volume sampler from June, 2000 to June, 2002 in the semi-rural atmosphere. Using monitoring data for two years, we tried to investigate the annual cycles of gaseous OCPs. We considered three functions to describe the annual cycle: Gaussian, Lorentzian and sinusoidal functions. These functions accounted for $54{\sim}91%$ of the variability in concentration for each gaseous OCPs, and the sinusoidal function gave the best fits. It was seen that the gaseous OCPs concentration increased during the warmer weather while decreased during colder weather. The variation of the gaseous OCPs concentration was closely similar to the variations of ambient temperature. The annual cycle of endosulfan was strongly higher than in comparison with other gaseous OCPs, while for ${\gamma}-HCH$, the cycle was weakly high and did not show apparent seasonal variation. The position of the annual maximum exists generally late July to early August. The period that showed levels more than a half maximum was from late June to early September.