• Title/Summary/Keyword: Concentration of pollutants

Search Result 1,311, Processing Time 0.031 seconds

Concentration of Air Pollutants and Asthma in Taejon City (대전지역 대기오염물질농도와 천식 환자수의 관련성)

  • 서원호;장성실;권호자
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.2
    • /
    • pp.80-90
    • /
    • 2000
  • To determine the effect of air pollutants in Taejon City, we used medical insurance claim data for asthma and the data monitored from telemetry system of Ministry of Environment for air pollutants and meteorological factors. From November 1st, 1997 to October 31th, 1998, 95,629 asthma patients were covered by medical insurance at Taejon City. Subjects were composed of 49,563 males (51.8%) and 46.336 females(48.2%), and among the subjects, the proportion under 15 years old was 62.8% of the total. During the study period, daily mean concentrations of each air pollutants-So2, No2, CO, O3 and TSP-were 9.8 ppb, 17.6 ppm, 1.414 pp, 17.3 ppb and 60.6 $\mu\textrm{g}$/㎥, respectively, which were lower than each of the environmental recommended exposure levels, Through the simple correlation analysis between each air pollutants and meteorological factors, O3 was positively correlated with temperature, but negatively with relative humidity. TSP, SO2, NO2, CO were negatively correlated with meteorological factors, and these air pollutants except O3 were positively correlated with each other, O3 was correlated with TSP positively but the others negatively. Estimating relative risks of each air pollutant with the baseline general additive model, daily mean concentrations of TSP(Lag 0, 1, 4, 5day) were significantly associated with the increase of the asthma admission. Two age subgroups, under 15 and 15~54 have shown various association of all air pollutants concentration with the asthma admission. However, in case of over 54 age subgroup, only TSP(Lag 0 day) among all air pollutants was associated with the asthma admission. Each of ambient outdoor pollutant concentrations in Taejon City are significantly associated with the admission of asthma patients even though all concentrations in Taejon City are significantly associated with the admission of asthma patients even though all concentrations were much lower than the environmental recommended exposure levels. Therefore, continuous effort lowering air pollutant concentration and introducing an active environmental conservation policy should be implanted for preventing hazardous health effects. Considering major proportion of asthma admissions, high susceptibility and less confounding factors among the age subgroup under 15 will be a useful target population for assessing such health effect monitoring.

  • PDF

Investigation of the Environment for Conservation in the Facilities of Exhibition and Collection for Cultural Properties (문화재 전시 및 수장시설 내에서의 보존환경 조사연구)

  • Hong, Jung-Ki;Kim, Sa-Dug;Kim, Soon-Kwan;Kang, Dai-Ill;Lee, Myeong-Hui
    • 보존과학연구
    • /
    • s.22
    • /
    • pp.155-171
    • /
    • 2001
  • The facilities of exhibition and collection for cultural properties is affected by environmental pollution. In order to accumulate a store of basic data, we was investigated eight points(three points at exhibition room and five points at collection room) at four institutes, from December 2000 to March 2001.As a result of investigation, the temperature of A-Exhibition room measured low because of don’t moved HVAC(Heating, Ventilation and Air-Conditioning) System, B Exhibition room is dry for the effect of air-conditioner and the air pollutants concentration of C-Exhibition room is high for the kind of an exhibition room. The air-condition was varied within the open period. The air pollutants concentration of A-Collection room is measured high because the air-pollutants is generated in a new buildings and the air pollutants concentration of C-1 & C-2-Collection room is high for the kind of an collection room. It is necessary to ventilate sufficiently.

  • PDF

Exposure Characteristics of Indoor Air Pollutants in Some Local Pubic Buses (IoT 기반 시내버스 실내공기질 노출 특성)

  • Kim, Ho-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.1
    • /
    • pp.44-51
    • /
    • 2022
  • Background: Air pollution is increasing together with industrialization and urbanization. In order to reduce air pollution, public transportation is recommended rather than private cars, and the number of passengers using public transportation is increasing accordingly. This study observes the concentration of indoor pollutants in city buses over time. Through this means, we intend to suggest a plan to manage the indoor air quality in city buses. Objectives: The concentration of indoor pollution in public transportation was investigated from April 2021 to January 2022. Based on this, we evaluated the exposure to indoor pollutants. Methods: Six city bus lines in an industrial city were selected for the research, and indoor pollution was measured through IoT (Internet of Things)-based sensor-type measuring devices. The concentration of pollutants was measured every minute, and statistical data were constructed based on the measurement results. Results: In all the city buses studied, the average concentration of pollutants were below the guidelines. However, some measurement results showed cases of exceeding the guidelines. As a result of the analysis by time zone, there were more cases in which pollutants exceeded the standard value during rush hour compared to at other times. A risk assessment for PM10 was performed by evaluating the excess mortality risk from exposure and the risk from inhalation exposure. Conclusions: All measured indoor pollutants in the city buses did not exceed the guidelines. Also, the risk assessment results were found to be within the level of safety. However, if a city bus is used for a long time, there is a possibility that there may be an impact on the human body due to inhalation exposure, so additional management is required.

Environmental Distribution of Air Pollutants and Environmental Risk Assessment in Regional Scale

  • Matsumoto, Fumio;Saito, Mitsugu;Otsuka, Naohiro
    • International Journal of Safety
    • /
    • v.9 no.1
    • /
    • pp.35-42
    • /
    • 2010
  • We measured the concentrations of air pollutants at several residential sites, roadside sites and industrial sites in Iwate Prefecture, Japan. And the concentration distributions of air pollutants were estimated by atmospheric dispersion model using air emissions data. Based on those results, we calculated environmental risk of air pollutants emitted in Iwate Prefecture. As a result, it was found that the surround of factories with high emissions and highly toxic chemicals and the roadsides were high risk area, benzo(a)pyrene, formaldehyde and ozone exceeded the $10^{-5}$ risk level. Moreover, we tried to use "Loss of life expectancy: LLE" for an index to explain those risk to general public intelligibly. The total LLE of the carcinogenic chemicals was about 8.6 hours. Moreover, LLE of ozone was about 9.2 hours. Ozone has a big influence compared with the carcinogenic chemicals.

Nonpoint Pollutants Sources Characteristics of Initial Surface Runoff on the Land Use Types (토지이용별에 따른 초기강우 유출량의 비점오염물 특성 분석)

  • Choi, Yun-Yeong;Jung, Se-Young;Choi, Jeong-Woo
    • Journal of Environmental Science International
    • /
    • v.20 no.3
    • /
    • pp.417-426
    • /
    • 2011
  • This study was conducted to investigate runoff characteristics of non-point pollutants source at the urban and rural zones in sangju area. The monitoring was conducted with seven events for ten months and Event mean Concentration(EMC) and First Flush Effect(FFE) of SS and BOD were calculated on the result of the water quality parameters. During rainfall event, the peak concentrations of SS and BOD were observed after 3~4 hours of rainfall in rural areas. Whereas, the peak concentrations occurred within 1~2 hours after rainfall and then the highest concentration of NPS pollutants sharply decreased, showing strong first flush effect in urban areas. The cumulative load curves for NPS pollutants showed above the $45^{\circ}$ straight line, indicating that fist flush effect occurred in urban areas. The mean SS EMC values of rural areas ranged from 0.9~3.3mg/L, it was higher value when compare to urban areas. While the mean BOD values of urban areas were shown the highest values.

A Study on the Reducing Ratio of VOCs and Formaldehyde by Bake Out (Bake Out에 의한 실내오염물질 저감에 관한 연구)

  • Cho, Hyun;Park, Yong-Seung;Yoo, Bok-Hee;Hong, Cheon-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2004.11a
    • /
    • pp.319-322
    • /
    • 2004
  • The purpose of this study is to evaluate the reduction effect of bake out on the concentration of indoor air pollutants by measuring the concentration of indoor pollutants(VOCs, HCHO) after the bake out. As a result of the study, bake out was considerably effective in reducing the concentration o( indoor air pollutants, showing relatively high reduction ratio around 40${\sim}$56%. However, continuous attention and control after the bake out is required for the prevention of the rise of the concentration by subsequent emission.

  • PDF

Numerical Simulation of Flow Field and Air Pollutatnts Concentration in Kwangyang Bay (광양만권의 유동장 및 대기오염농도예측)

  • 정용현
    • Journal of Environmental Science International
    • /
    • v.9 no.5
    • /
    • pp.397-402
    • /
    • 2000
  • Numerical simulation model using nesting method and considering topographic features was developed to predict atmospheric environments atmospheric flow temperature and diffusion of air pollutants in Kwangyang bay where having complex areas of point sources Korea. In addition developed simulation model was used tracing of spreading range of pollutants when a gas leaks suddenly from Yeo-cheon industrial complex. by comparing the measured and calculated data on atmospheric flow temperature and diffusion of air pollutants the results showed that this model can be well applied and complicated topography affected the diffusion of air pollutants.

  • PDF

A Study on the Concentration Distribution Characteristics of Air Pollutants by Yellow Sand Phenomenon (황사현상에 의한 대기오염물질의 농도분포 특성에 관한 연구)

  • 이용기;김종찬;최승석;임홍빈;최양희;이수문
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.2
    • /
    • pp.71-78
    • /
    • 2002
  • This study was conducted to evaluate the concentration distribution characteristics of air pollutants by the yellow sand from China. The concentrations and chemical properties of FPM contained in the yellow sand were compared with those of air pollutants when having no yellow sand in order to estimate the variation characteristics and the originated source of air pollutants moved by yellow sand. The concentrations of PM-2.5 and PM-10 contained in the yellow sand showed an increase of 2.3 to 2.7 times than usual, and the concentrations of NO2 and SO2 in the gaseous pollutants showed an increase of about 1.6 times by yellow sand, and thus the air contamination was much influenced by yellow sand phenomenon. The concentrations of inorganic elements contained in FPM from the yellow sand showed a higher concentration variation in the order of Al>Mg>Zn>Pb than usual. The concentration coefficient of air aerosol during the yellow sand period showed that Na, K, Ca, Mg and Fe were originated from natural source, and Pb, Cr, Cd, Cu and Zn were originated from artificial source for inorganic elements. The correlation analysis between FPM and inorganic elements showed in the descending order of Al>K>Pb>Mg, and thus the deposited amount of Pb was influenced by that of yellow sand. The average concentrations of PM-10 measured during the yellow sand period exceeded the Korea Air Environmental Standard and showed a excess rate of 3.4 times in the maximum but the average concentrations of PM-2.5 showed within the United States Air Environmental Standard.

A Study on Characteristics of Pollutants from LNG Facilities (천연가스 사용설비 오염물질 배출특성 연구)

  • Lee, J.S.;Lee, H.C.;You, H.S.;Han, J.O.
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.223-226
    • /
    • 2004
  • The thesis examined the charactcri:stlC of pollutants exhausted from LNG facilities. So, combustion gas and concentration of greenhouse gas exhausted from gas boiler for home use, furnace facilities, electric power facilities, boiler for industrial use and boiler for heating fueled LNG is measured. And the exhaust factor of pollutants is produced by classify of pollutants in detail. And this exhaust factor is compared and investigated with data of a foreign nations.

  • PDF

Effect of Green Buffer Zone in Reducing Gaseous Air Pollutants in the Shiwha Industrial Area (시화공단 완충녹지대의 대기오염물질 저감 효과 분석)

  • Song Young-Bae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.6 s.113
    • /
    • pp.90-97
    • /
    • 2006
  • The effects of a green buffer zone to protect a residential area from air pollution from industrial facilities and traffic was examined by analyzing the case of a green buffer zone in the Shiwha industrial complex. The green buffer zone is 175 m wide. The intent was to assess the dispersion patterns of atmospheric air pollutants and the reduction in concentration around the green buffer zone. To measure atmospheric sulfur dioxide$(SO_2)$ and nitrogen dioxide$(NO_2)$ concentration, badge-type passive samplers were used and set up at 76 locations in order to measure the concentration of air pollutants with respect to the spatial dispersion. The weighted mean values of $SO_2\;and\;NO_2$ concentration were $3\~57 ppb\;and\;18\~62 ppb$ and the differences among the green buffer zone, the industrial area and the residential areas were $0.7\~1.1 ppb$. Mean values of atmospheric concentrations of $NO_2$ were similar in industrial and, residential areas and the green buffer zone. Results of the study show that the effect of the green buffer zone on reducing the dispersion of air pollutants was very low. This study also recommends that micro-climate, i.e., wind direction should be considered as a factor for planning and design of green buffer zones.