• Title/Summary/Keyword: Computed tomography scanner

Search Result 104, Processing Time 0.03 seconds

Comparison of PET image quality using simultaneous PET/MR by attenuation correction with various MR pulse sequences

  • Park, Chan Rok;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.51 no.6
    • /
    • pp.1610-1615
    • /
    • 2019
  • Positron emission tomography (PET)/magnetic resonance (MR) scanning has the advantage of less additional exposure to radiation than does PET/computed tomography (CT). In particular, MR based attenuation correction (MR AC) can greatly affect the image quality of PET and is frequently obtained using various MR sequences. Thus, the purpose of the current study was to quantitatively compare the image quality between MR non-AC (MR NAC) and MR AC in PET images with three MR sequences. Percent image uniformity (PIU), percent contrast recovery (PCR), and percent background variability (PBV) were estimated to evaluate the quality of PET images with MR AC. Based on the results of PIU, 15.2% increase in the average quality was observed for PET images with MR AC than for PET images with MR NAC. In addition, 28.6% and 71.1% improvement in the average results of PCR and PBV respectively, was observed for PET images with MR AC compared with that with MR NAC. Moreover, no significant difference was observed among the average values using three MR sequences. In conclusion, the current study demonstrated that PET with MR AC improved the image quality and can be help diagnosis in all MR sequence cases.

A simplified CAD/CAM extraoral surgical guide for therapeutic injections

  • Cameron, Andrew;Custodio, Antonio Luis Neto;Bakr, Mahmoud;Reher, Peter
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.21 no.3
    • /
    • pp.253-260
    • /
    • 2021
  • Therapeutic injections into the craniofacial region can be a complex procedure because of the nature of its anatomical structure. This technical note demonstrates a process for creating an extra-oral template to inject therapeutic substances into the temporomandibular joint and the lateral pterygoid muscle. The described process involves merging cone-beam computed tomography data and extra-oral facial scans obtained using a mobile device to establish a correlated data set for virtual planning. Virtual injection points were simulated using existing dental implant planning software to assist clinicians in precisely targeting specific anatomical structures. A template was designed and then 3D printed. The printed template showed adequate surface fit. This innovative process demonstrates a potential new clinical technique. However, further validation and in vivo trials are necessary to assess its full potential.

Immediate loading of mandibular single implant by using surgical guide and modeless digital prosthesis: a case report (수술용 가이드와 modeless 디지털 보철물을 이용한 하악 구치부 단일 임플란트 즉시 하중 증례)

  • Lim, Hyun-jeong;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.299-306
    • /
    • 2017
  • In this case report, immediate loading of an implant-supported single-tooth prosthesis through complete digital workflow. A patient presented for restoration of missing a single tooth in the mandibular first molar. The digital impression was made with intraoral scanner and implant was placed using surgical guide pre-fabricated with pre-operative computed tomography (CT) and scan data. After 1 week later, prefabricated customized abutment and provisional restoration were connected for immediate loading. After 8 weeks later, abutment level impression was taken by intraoral scanner. At 3 months later from implant installation, monolithic zirconia crown were fabricated. This clinical report presents satisfying result in accuracy and patient satisfaction. A completely modeless digital procedure met expectations regarding precision, esthetics, and functionality.

Case Study of Quality Assurance for MDCT Image Quality Evaluation Using AAPM CT Performance Phantom (AAPM CT 성능 평가용 팬텀을 이용한 전산화단층촬영의 영상 평가를 위한 정도관리 사례 연구)

  • Jang, Keun-Jo;Kweon, Dae-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.7
    • /
    • pp.114-123
    • /
    • 2007
  • The increasing use of computed tomography (CT) as a diagnostic tool creates the need from and efficient means of evaluating the performance of the CT scanner now in use. Accordingly, acceptance testing and quality assurance of CT is of great importance. The aim of this study is to analyze of AAPM CT performance phantom in the CT accreditation program. The modular phantom offers the CT system with which to measure eight performance parameters. The parameters are listed of CT attenuation coefficient of water, noise, uniformity, spatial resolution, contrast resolution, slice thickness (5 and 10 mm), artifacts and alignment. The phantom evaluation was done by two radiologists. The acceptance testing protocol described here in demonstrates the successful of the guidelines for the quality assurance using AAPM CT performance phantom. We need to be upgraded for the CT image quality and make the standard reference of the quality assurance in the CT.

Effectiveness of Bismuth Shield to Reduce Eye Lens Radiation Dose Using the Photoluminescence Dosimetry in Computed Tomography (CT 검사에서 유리선량계를 이용한 수정체의 비스무트 차폐 효과)

  • Jung, Mi-Young;Kweon, Dae-Cheol;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.307-312
    • /
    • 2009
  • The purpose of our study was to determine the eyeradiation dose when performing routine multi-detector computed tomography (MDCT). We also evaluated dose reduction and the effect on image quality of using a bismuth eye shield when performing head MDCT. Examinations were performed with a 64MDCT scanner. To compare the shielded/unshielded lens dose, the examination was performed with and without bismuth shielding in anthropomorphic phantom. To determine the average lens radiation dose, we imaged an anthropomorphic phantom into which calibrated photoluminescence glass dosimeter (PLD) were placed to measure the dose to lens. The phantom was imaged using the same protocol. Radiation doses to the lens with and without the lensshielding were measured and compared using the Student t test. In the qualitative evaluation of the MDCT scans, all were considered to be of diagnostic quality. We did not see any differences in quality between the shielded and unshielded brain. The mean radiation doses to the eyewith the shield and to those without the shield were 21.54 versus 10.46 mGy, respectively. The lens shield enabled a 51.3% decrease in radiation dose to the lens. Bismuth in-plane shielding for routine eye and head MDCT decreased radiation dose to the lenswithout qualitative changes in image quality. The other radiosensitive superficial organs specifically must be protected with shielding.

  • PDF

Comparison of CT numbers between cone-beam CT and multi-detector CT (Cone-beam CT와 multi-detector CT영상에서 측정된 CT number에 대한 비교연구)

  • Kim, Dong-Soo;Han, Won-Jeong;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.40 no.2
    • /
    • pp.63-68
    • /
    • 2010
  • Purpose : To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Materials and Methods : Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, $\rho$ ($g/cm^3$), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. Results : CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were $\rho$=0.001H+1.07 with $R^2$ value of 0.999 for Somatom Emotion, $\rho$=0.002H+1.09 with $R^2$ value of 0.991 for Alphard VEGA, $\rho$=0.001H+1.43 with $R^2$ value of 0.980 for i-CAT and $\rho$=0.001H+1.30 with $R^2$ value of 0.975 for Implagraphy. Conclusion: CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

Extra Dose Measurement of Differential Slice Thickness of MVCT Image with Helical Tomotherapy (토모테라피 치료 시 MVCT Image의 Slice Thickness 차이에 따른 선량 비교)

  • Lee, Byungkoo;Kang, Suman
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.145-149
    • /
    • 2013
  • Helical Tomotherapy is an innovative means of delivering intensity modulated radiation therapy (IMRT) using a device that merges features of a linear accelerator and helical computed tomography (CT) scanner. Hereat, during helical tomotherapy process, megavoltage computed tomography (MVCT) image are usually used for guiding the precise set-up of patient before/after treatment delivery. But which would certainly increase the total dose for patients, this study was to investigate the imaging dose of MVCT using the cylindrical "Cheese" phantom on a tomotherapy machine. A set of cylindrical "Cheese" phantom was adopted for scanning with respectively pitch value (1, 2, 3 mm) with same number slice (10 slice), same length (approximately 9 cm) and phantom set-ups on the couch of tomotherapy system. The average MVCT imaging dose were measured using A1SL ion chamber inserted in the phantom with preset geometry. The MVCT scanning average dose for the cylindrical "Cheese" phantom was 2.24 cGy, 1.02 cGy, 0.81 cGy during respectively pitch value (pitch 1, 2, 3 mm) with same number slice (10 slice), and same length's average dose was 2.47 cGy, 1.28 cGy, 0.88 cGy respectively (pitch 1, 2, 3 mm). Two major parameters, the assigned pitch numbers and scanning length, where the most important impacts to the dose variation. The MVCT dose was inversely proportional to the CT pitch value. The results may provide a reliable guidance for proper planning design of the scanning region, which is valuable to help minimize the extra dose to patient. Questionnaires were distributed to Radiology departments at hospitals with 300 sickbeds throughout the Pohang region of North Gyeongsang Province concerning awareness and performance levels of infection control. The investigation included measurements of the pollution levels of imaging equipment and assistive apparatuses in order to prepare a plan for the activation of prevention and management of hospital infections. The survey was designed to question respondents in regards to personal data, infection management prevention education, and infection management guidelines.

Effect of Titanium Prosthesis on Computed Tomography Measurements of Bone Mineral Density

  • Han, S.M.;Zude Feng
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.177-182
    • /
    • 1998
  • This study investigated the effects of a titanium prosthesis, malalignment, field of view, and distal flare of titanium prosthesis on computed tomography( CT) measurements of home mineral density. Eight femora and eight tibiae from fresh male cadavers were used. Fifteen pieces of cancellous bone from the proximal tibiae were milled into rectangular parallelepipeds. Parallelepipeds and femors were scanned with and without titanium prosthesis when centered in the gantry of the CT scanner and malaligned, respectively. Image data were then reconstructed with field of view of 10 and 30 cm. Bone mineral density(BMD) values were obtained from CT images using C-MED software. The effects of titanium prosthesis, malalignmetn, and field of view were investigated. When bone was centered in the gantry of the CT scanner, the mean relative difference of BMD measurements caused by a titanium prosthesis was less than 1% for both cortical and cancellous bone. Field of view had negligible effect on BMD measurements as well. Malalignment and distal flare of prosthesis, however, caused a significant difference in BMD measurements(p<0.0001). The titanium prosthesis did not interfere with malalignment combining the existence of a titnium prosthesis on BMD measurements was significant.

  • PDF

Three-dimensional computed tomography evaluation of craniofacial characteristics according to lateral deviation of chin

  • CHOI, Hyo-Won;KIM, Bola;KIM, Jae-Young;HUH, Jong-Ki;PARK, Kwang-Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.57.1-57.8
    • /
    • 2019
  • Background: The relationship between the lateral deviation of chin and the upper and middle facial third asymmetry is still controversial. The purpose of this study is to evaluate the correlation of upper and middle facial third asymmetry with lateral deviation of chin using 3-dimensional computed tomography. The study was conducted on patients who underwent orthognathic surgery from January 2016 to August 2017. A total of 40 patients were included in this retrospective study. A spiral scanner was used to obtain the 3-dimensional computed tomography scans. The landmarks were assigned on the reconstructed 3-dimensional images, and their locations were verified on the axial, midsagittal, and coronal slices. The Pearson correlation analysis was performed to evaluate the correlation between chin deviation and difference between the measurements of distances in paired craniofacial structures. Statistical analysis was performed at a significance level of 5%. Results: In mandible, the degree of chin deviation was correlated with the mandibular length and mandibular body length. Mandibular length and mandibular body length are shorter on the deviated-chin side compared to that on the non-deviated side (mandibular length, r = -0.897, p value < 0.001; mandibular body length, r = -0.318, p value = 0.045). In the upper and middle facial thirds, the degree of chin deviation was correlated with the vertical asymmetry of the glenoid fossa and zygonion. Glenoid fossa and zygonion are superior on the deviated-chin side than on the non-deviated side (glenoid fossa, r = 0.317, p value = 0.046; zygonion, r = 0.357, p value = 0.024). Conclusion: Lateral deviation of chin is correlated with upper and middle facial third asymmetry as well as lower facial third asymmetry. As a result, treatment planning in patients with chin deviation should involve a careful evaluation of the asymmetry of the upper and middle facial thirds to ensure complete patient satisfaction.

Limitations of 99mTc-DMSA scan in diagnosing acute pyelonephritis in children (이해관계 선언)

  • Kim, Byung Gee;Kwak, Jae Ryoung;Park, Ji Min;Pai, Ki Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.3
    • /
    • pp.408-413
    • /
    • 2010
  • Purpose : We aimed to prove the relative limitation of $^{99m}Tc-DMSA$ scintigraphy (DMSA) compared to computed tomography (CT) in diagnosing acute pyelonephritis (APN) in children. Methods : Since September 2006, after a 64-channel CT was imported, 10 DMSA false-negative patients have been identified: these patients underwent a CT scan for acute abdomen or acute febrile symptoms and were diagnosed as having APN; however, their DMSA scans were clear. We focused on these 10 DMSA false-negative patients and analyzed their clinical findings and CT results. We used Philips Brilliance Power 64-channel CT scanner for the CT scan and Siemens Orbitor Nuclear Camera 60 Hz for the DMSA scan. Results : The 10 DMSA false-negative patients were mostly males (80%) and infants (80%). They had fever for a mean of 1.1-day duration before admission and showed increase in acute reactants: leukocyte, erythrocyte sedimentation rate, and C-reactive protein. The CT findings of renal lesions were focal in 6 (60%) cases and diffuse in 4 (40%) cases, and most of the lesions were unilateral in 80% of patients. CT proved that 22 renal lesions were neglected by DMSA. Differential renal function test by DMSA was also of no use in the evaluation of renal lesions. Conclusion : In this study, DMSA scan showed limitation in finding renal cortical lesions of CT-proven APN patients. DMSA false-negative results seem to occur at early-phase disease of infantile age, but more prospective studies are needed to determine the reasons and their prevalence.