• 제목/요약/키워드: Composite specimen

검색결과 1,205건 처리시간 0.029초

극저온 환경에서 탄소섬유강화 직조/일방향 복합재료의 인장 물성 측정 (Tensile Properties of CERP Fabric/Unidirectional Composites under Cryogenic Environment)

  • 김명곤;김철웅;강상국;김천곤;홍창선
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 추계학술발표대회 논문집
    • /
    • pp.115-118
    • /
    • 2003
  • This research aims to measure mechanical tensile properties of CFRP composites for cryogenic tank material. Through the cryogenic chamber, tensile tests are peformed under cryogenic temperature for graphite/epoxy fabric specimen aged at $-150^{\circ}C$ for 30hrs with load and graphite/epoxy unidirectional specimen 3-cycled from RT to $-100^{\circ}C$ with load. For graphite/epoxy fabric specimen, tensile modulus showed to increase after aging at cryogenic temperature(CT) while to decrease after aging at room temperature(RT) and tensile strength is more decreased after CT-aged than at RT-aged. For graphite/epoxy unidirectional specimen, tensile modulus was almost not changed after 3-cycling but strength showed the trend of decrease as increase the number of cycling.

  • PDF

Crack Propagation at Boundary Face of Composite Compact Tension Specimen

  • Cho, Jae-Ung;Han, Moon-Sik
    • 한국생산제조학회지
    • /
    • 제22권2호
    • /
    • pp.337-341
    • /
    • 2013
  • In this study, fatigue crack propagation in composite material under fatigue is investigated by simulation result. When another material on the specimen exists vertically to the crack line, the phenomena that crack may go straight or propagate along the boundary face according to the elastic modulus ratio of another material to matrix are investigated with compact tension specimen by compliance method. Crack propagation direction is evaluated by compliance method. By arranging this study result systematically about the crack propagation behavior due to the stiffness of inhomogeneous material, high-tech material (automobile, aircraft and steel industry) can be improved. The estimation of safety design and life (construction & nuclear power station, etc.) will be of great value industrially.

공진현상을 이용한 복합재 블레이드의 피로시험 (Resonant fatigue testing of composite rotor blades)

  • 기영중;이상원;박선규
    • 항공우주시스템공학회지
    • /
    • 제4권2호
    • /
    • pp.21-25
    • /
    • 2010
  • Fatigue properties of composite materials are extremely important to design durable and reliable helicopter rotor blades. However, it is very difficult to apply conventional fatigue test loads in short period. Therefore, accelerating test speed and facilitating spectrum load realization are required. In this study, we have developed a fatigue testing method that uses a resonance of simply supported beam type blade specimen. This test consists in exciting the blade specimen with a frequency that corresponds to its natural frequency. In that case, the test specimen similar to a beam fixed between two pivot points starts vibrating and is significantly deformed. Resonant fatigue tests were performed by changing exciting vertical amplitude and frequency, and S-N curves of each composite materials were successfully obtained.

  • PDF

The Strength Evaluation on Repaired Plain Woven CFRP Composite with a Circular Hole

  • Kwon, Oh-Heon;Park, Jun-Ho
    • International Journal of Safety
    • /
    • 제8권1호
    • /
    • pp.1-5
    • /
    • 2009
  • The CFRP composite has unique properties that offer high strength and stiffness, even though it has light weight. Therefore it can be used in many industrial applications. When mechanical fasteners are used for joining composites, high stress concentrations appear near the edge of holes prepared for accommodating structural bolts and rivets. This presence of high stress concentrations can be a source of damage. The aim of this work is to evaluate fracture behavior and patterns of plain woven CFRP with circular hole and repairing patch element. The maximum strength and pattern for the plain woven carbon composite specimen with the repaired circular hole were examined. From the results, we show that repairing of the CFRP composite specimen with ($\pi$) 3~5 mm of circular hole diameter results in load rising effect and the repairing is more effective as bigger hole specimen.

공진현상을 이용한 실물 복합재 헬리콥터 블레이드의 피로수명 평가 (Resonant Fatigue Testing of Full-Scale Composite Helicopter Blades)

  • 기영중;김태주;김승호
    • 항공우주기술
    • /
    • 제9권2호
    • /
    • pp.1-7
    • /
    • 2010
  • Fatigue properties of composite materials are extremely important to design durable and reliable helicopter rotor blades. However, it is very difficult to apply conventional fatigue test loads in short period. Therefore, accelerating test speed and facilitating spectrum load realization are required. In this study, we have developed a fatigue testing method that uses a resonance of simply supported beam type blade specimen. This test consists in exciting the blade specimen with a frequency that corresponds to its natural frequency. In that case, the test specimen similar to a beam fixed between two pivot points starts vibrating and is significantly deformed. Resonant fatigue tests were performed by changing exciting vertical amplitude and frequency, and S-N curves of each composite materials were successfully obtained.

무아레 간섭계를 이용한 복합재 보강 콘크리트의 변형해석 (Deformation Analysis of Composits-Patched Concrete Using Moire Interferometry)

  • 주진원;채수은;신동일
    • 대한기계학회논문집A
    • /
    • 제26권1호
    • /
    • pp.160-170
    • /
    • 2002
  • Many of aged and damaged concrete structure have been revitalized with composite reinforcement. Flexural behaviors of composite-patched concrete specimens are characterized by high-sensitivity moire interferometry. The three-mirror, four-beam interferometry system and a compact loading system are used for obtaining singe patterns representing whole-field contour maps of in-plane displacements. It is seen from the calibration test for the loading system that the measured bending displacement is in excellent agreement with the displacement calculated by the beam theory. The crack opening displacement as well as the bending and the horizontal displacement fur the notched and unnotched specimen are investigated. The results also show that the notched specimen reinforced by a composite sheet has sufficient stiffness and strength compared to the original concrete specimen.

Hybrid infrared-visible multiview correlation to study damage in a woven composite complex-shaped specimen

  • Andrija Zaplatic;Zvonimir Tomicevic;Xuyang Chang;Ivica Skozrit;Stephane Roux;Francois Hild
    • Coupled systems mechanics
    • /
    • 제12권5호
    • /
    • pp.445-459
    • /
    • 2023
  • In this study, a cyclic tensile test on a notched butterfly specimen made of woven glass fiber composite was performed on a modified Arcan fixture. During the mechanical test, the sample was monitored with a hybrid stereoscopic system comprised of two visible lights and one infrared camera. The visible light cameras were employed for kinematic measurements using a finite-element-based multiview correlation technique. A semi-hybrid correlation approach was followed, providing Lagrangian temperature fields of the Region of Interest. Due to the complex composite architecture and specimen shape, localized shearing was observed during the tensile loading. Furthermore, asymmetrical damage developed around the notches as revealed by localized strains and thermal hot spots.

A COMPARATIVE STUDY BETWEEN DEGREE OF CONVERSION AND FLEXURAL STRENGTH OF COMPOSITE RESINS

  • Lee Seong-Hee;Pae Ahran;Kim Sung-Hun
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.333-342
    • /
    • 2006
  • Statement of problem. Although many studies have been carried out to investigate the correlation between the degree of conversion and the flexural strength of composite resins, there is minimal information in the literature attempting to compare degree of conversion, flexural strength and their correlation between restorative composite resins and flowable composite resins. Purpose. The purposes of this study were to measure the degree of conversion and flexural strength of composite resins with different rheological behavior and to correlate the two properties. Materials and methods. Four restorative (Vit-1-escence, Z-250, Tetric ceram, Esthet-X) and four flowable (Aeliteflo, Admiraflow, Permaflo, Revolution) light-curing composite resins were investigated. The degree of conversion(DC) was analyzed with Fourier transfer infra-red spectroscopy(FTIR) spectrum by a potassium bromide(KBr) pellet transmission method. The spectrum of the unpolymerized specimen had been measured before the specimen was irradiated for 60s with a visible light curing unit. The Poiymerized specimen was scanned for its in spectrum. The flexural strength(FS) was measured with 3-point bending test according to ISO 4049 after storage in water at $37^{\circ}C$ for 24 hours. The data were statistically analyzed by an independent sample t-test and one-way ANOVA at the significance level of 0.05. The dependence of flexural strength on the degree of conversion was also analyzed by regression analysis. Results. Mean DC and FS values ranged from 43% to 61% and from 84.7MPa to 156.7MPa respectively. DC values of the flowable composite resins were significantly higher than those of restorative composite resins (P < 0.05). The FS values of restorative composite resins were greater than those of flowable composite resins. No statistically significant correlation was observed between the DC and the FS tested in any of the composites. The dependence of FS on DC in restorative or flowable composite resins was not significant. Conclusion. It can be concluded that radical polymerization of the organic matrix is not a major factor in determining flexural strength of the commercially available composite resins.

복합재료의 계면 전단강도를 평가하기 위한 새로운 반구형 미소접합 시험편 (A novel hemispherical microbond specimen for evaluating the interfacial shear strength of single fiber composite)

  • 박주언;최낙삼
    • Composites Research
    • /
    • 제21권2호
    • /
    • pp.25-30
    • /
    • 2008
  • A hemispherical microbond specimen adhered onto single carbon fiber has been proposed for evaluating the interfacial shear strength between epoxy and carbon fiber. Hemispherical microbond specimens showed low interfacial shear strength data and its small standard deviation as compared with the droplet one, which seemed to be caused by the reduction of the meniscus effects and of the stress concentration in the region contacting with the tip of pin hole. In comparison with the droplet specimen the hemispherical specimen showed the shear stress distribution similar to the cylindrical one in that low stress concentration arose around the contacting region. Average interfacial shear strength obtained by the hemispherical ones represented a good correlation with the hardness of the epoxy matrix.

Flexural behavior of partially prefabricated partially encased composite beams

  • Liang, Jiong-feng;Zhang, Liu-feng;Yang, Ying-hua;Wei, Li
    • Steel and Composite Structures
    • /
    • 제38권6호
    • /
    • pp.705-716
    • /
    • 2021
  • An innovative partially precast partially encased composite beam (PPECB) is put forward based on the existing research. In order to study the flexural performance of the new composite beam which has precast part and cast-in-place part, six prefabricated specimens and one cast-in-place specimen are designed with considering the influence of the production method, the steel flange thickness, the concrete strength grade and the stirrup process on the behavior of the composite beam. Through four points loading and test data collection and analysis, the behavior of partially prefabricated specimen is similar to that of cast-in-place specimen, and the casting method, the thickness of the steel flange, the concrete strength grade and the stirrup process have different influence on the crack, yield and peak load bearing capacity of the component. Finally, the calculation theory of plastic bending of partially precast partially encased concrete composite beams is given. The calculation results are in good agreement with the experimental results, which can be used for practical engineering theory guidance. This paper can provide reference value for further research and engineering application.