• Title/Summary/Keyword: Compatible

Search Result 2,813, Processing Time 0.032 seconds

COMMON FIXED POINT THEOREMS OF MEIR-KEELER TYPE ON MULTIPLICATIVE METRIC SPACES

  • DESHPANDE, BHAVANA;SHEIKH, SAJAD AHMAD
    • The Pure and Applied Mathematics
    • /
    • v.23 no.2
    • /
    • pp.131-143
    • /
    • 2016
  • In this paper, we present some common fixed point theorems for two pairs of weakly compatible self-mappings on multiplicative metric spaces satisfying a generalized Meir-Keeler type contractive condition. The results obtained in this paper extend, improve and generalize some well known comparable results in literature.

Backward-Query Compatible Schema Changes (후방-질의 공존의 스키마 변화)

  • 나영국
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.10c
    • /
    • pp.169-171
    • /
    • 2002
  • 변화하는 사업 환경에 적절히 대응하기 위해 온라인 데이터베이스의 스키마를 변화할 수 있는 능력은 필수적이다. 그러나 데이터베이스 스키마 변화는 그 스키마에 대해 쓰여진 기존의 응용 프로그램에 의해 제약을 받아왔다. 현재의 스키마를 변경하는 동시에 기존의 스키마를 보존하여 그 스키마에 쓰여진 질의 프로그램이 스키마 변화 이 후에도 지속적으로 동작할 수 있게 하여 기존 프로그램 재작성의 부담을 덜어준다. 이 논문은 기존의 스키마를 뷰로써 유지함으로써 뷰 활용 후방-질의 공존 (backward-query compatible) 스키마 변화의 알고리즘과 시스템을 제안한다.

  • PDF

6.25-Gb/s Optical Receiver Using A CMOS-Compatible Si Avalanche Photodetector

  • Kang, Hyo-Soon;Lee, Myung-Jae;Choi, Woo-Young
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.217-220
    • /
    • 2008
  • An optical receiver using a CMOS-compatible avalanche photodetector (CMOS-APD) is demonstrated. The CMOS-APD is fabricated with $0.18{\mu}m$ standard CMOS technology and the optical receiver is implemented by using the CMOS-APD and a transimpedance amplifier on a board. The optical receiver can detect 6.25-Gb/s data with the help of the series inductive peaking effect.

COMMON FIXED POINT THEOREMS FOR GENERALIZED 𝜓∫𝜑-WEAKLY CONTRACTIVE MAPPINGS IN G-METRIC SPACES

  • Kim, Jong Kyu;Kumar, Manoj;Bhardwaj, Preeti;Imdad, Mohammad
    • Nonlinear Functional Analysis and Applications
    • /
    • v.26 no.3
    • /
    • pp.565-580
    • /
    • 2021
  • In this paper, first of all we prove a fixed point theorem for 𝜓∫𝜑-weakly contractive mapping. Next, we prove some common fixed point theorems for a pair of weakly compatible self maps along with E.A. property and (CLR) property. An example is also given to support our results.

COMMON FIXED POINTS OF A PAIR OF MAPPINGS CONCERNING CONTRACTIVE INEQUALITIES OF INTEGRAL TYPE

  • Cai, Tao;Zhang, XiangShuai;Zhao, Liangshi
    • Nonlinear Functional Analysis and Applications
    • /
    • v.27 no.3
    • /
    • pp.603-620
    • /
    • 2022
  • Several common fixed point theorems for a pair of weakly compatible mappings satisfying contractive inequalities of integral type in a metric space are proved. The results obtained in this paper improve or differ from a few results existing in the literature.

COMMON FIXED POINT THEOREMS FOR A CLASS OF WEAKLY COMPATIBLE MAPPINGS IN D-METRIC SPACES

  • Kim, Jong-Kyu;Sedghi, Shaban;Shobe, Nabi
    • East Asian mathematical journal
    • /
    • v.25 no.1
    • /
    • pp.107-117
    • /
    • 2009
  • In this paper, we give some new definitions of D-metric spaces and we prove a common fixed point theorem for a class of mappings under the condition of weakly compatible mappings in complete D-metric spaces. We get some improved versions of several fixed point theorems in complete D-metric spaces.

Scalable Stereoscopic Video Coding for Heterogeneous Environments (이질적인 환경을 위한 스케러블 스테레오 영상 부호화)

  • 오세찬;이영호;우운택
    • Journal of Broadcast Engineering
    • /
    • v.9 no.3
    • /
    • pp.225-235
    • /
    • 2004
  • In this paper, we propose a new stereoscopic video coding approach for heterogeneous consumer devices by exploiting the concept of spatio-temporal scalability. The proposed method uses MPEG-2 standard for coding the left or main sequence and an enhanced compatible coding scheme for predicting the P- and B-type of frames of the right or auxiliary sequence. The enhanced compatible coding scheme predicts matching block by interpolating both two forward and backward motion predicted macroblocks and disparity predicted macroblock. To provide flexible stereo video service, we define both a temporally scalable layer and a spatially scalable layer for each eye-view. The experimental results show the efficiency of proposed coding scheme by comparison with already known methods and the advantages of disparity estimation in terms of scalability overhead. According to the experimental results, we expect the proposed functionalities will play a key role in establishing highly flexible stereo video service for ubiquitous computing environment where devices and network connections are heterogeneous.

Performance Analysis of a Vacuum-Compatible Air Bearing (진공용 공기베어링의 성능해석)

  • Khim, Gyung-Ho;Park, Chun-Hong;Lee, Hu-Sang;Kim, Seung-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.10
    • /
    • pp.103-112
    • /
    • 2006
  • This paper describes a theoretical analysis and experimental verification on the performances of a vacuum-compatible air bearing, which is designed with a cascaded exhaust scheme to minimize the air leakage in a vacuum environment. The design of the vacuum-compatible air bearing equipped with the differential exhaust system requires great care because several design parameters, such as the number of exhaust stages, diameter of exhaust tube, pumping speed of a vacuum pump, and bearing clearance greatly influence the air leakage and thus degree of vacuum. In this study, a performance analysis method was proposed to estimate the performances of the air bearing, such as load capacity, stiffness, and air leakage. Results indicate that the load capacity and stiffness of the air bearing was improved as its boundary pressure, which was determined by the $1^{st}$ exhaust method, was lowered, and the dominant factors on the chamber's degree of vacuum were the number of exhaust stages, exhaust tube diameter and bearing clearance. A vacuum chamber and air bearing stage using porous pad were fabricated to verify the theoretical analysis. The results demonstrate that chamber pressure up to an order of $10^{-3}$ Pa was achieved with the air bearing stage operating inside the chamber, and this analysis method was valid by comparing predicted values with experimental data, for the mass flow rates from the porous pad, and pressures at each exhaust port and chamber, respectively.

Mitral Valve Replacement -Report of Five Cases- (승모판막 이식수술 -5예 보고-)

  • 송요준
    • Journal of Chest Surgery
    • /
    • v.7 no.2
    • /
    • pp.189-200
    • /
    • 1974
  • The mitral valve replacement with Beall prosthetic valve was performed on three patients, and double valve replacement. aortic and mitral valve, was performed in this department.1) The preoperative studies about the first case were compatible with mitral steno-insufficency.The diseased mitral valve was replaced with the medium sized Beall prosthetic valve under the cardiopulmonary hypass using hypothermic hemodilution technique. The total perfusion time was eighty minutes. Immediate postoperative course was smooth, but this patient was died of asphyxia due to tracheomalacia complicated after tracheostomy 3 months after operation. Autopsy on this patient revealed that no thrombus and no ball variance could be found, and endothelization on the valve cuff was satisfactory. 2) The preoperative studies on the second case were compatible with mitral insufficiency. The diseased mitral valve was replaced with the medium sized Beall prosthetic valve under the cardiopulmonary bypass using hypothermic hemodilution technigue. The total perfusion time was 123 minutes. This patient was discharged in good condition and follow-up study after 16 months revealed the patient had enjoyed healthy life. 3) The preoperative studies about the third case were compatible with aortic insufficiency and mitral stenoinsufficiency. The diseased valves were replaced with type 2 sutureless Magovern aortic valve and the medium sized Beall mitral prosthesis under cardiopulmonary bypass using hypothermic hemodilution technIque and coronary artery perfusion. The total perfusion time was 155 minutes. This patient was discharged in good condition, but thromboembolism was developed 2 months after discharge. 4) The preoperative studies about the fourth case were compatible with mitral insufficiency. The diseased mitral valve was replaced with the medium sized Beall prosthetic valve. The total perfusion time was 132 minutes. The atrioventricular block developed just after operation but converted to normal sinus rhythmn on the third postperative day. The preoperative NYHA functional classification IV was converted to Class 1 or 11 at the time of discharge and this patient enjoyed healthy life. Attendum; The fifth case, nineteen years old male with mital insufficiency underwent Beall valve replacement and his course was uneventful 2 weeks after operation.

  • PDF