• Title/Summary/Keyword: Common mode 전압

Search Result 84, Processing Time 0.028 seconds

A new active common mode voltage Damper to suppress high frequency leakage current of PWM Inverter (새로운 능동형 커먼 모드 전압 감쇄기를 이용한 PWM 인버터의 고주파 누설전류 억제)

  • 구정회;이상훈;박성준;김철우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.423-431
    • /
    • 2001
  • This paper proposes a new active common-mode voltage damper circuit that is capable of suppressing a common-mode voltage produced in the PWM VSI-fed induction motor drives. The new active common mode voltage damper is consists of a four-level half-bridge Inverter and a common mode transformer with a blocking capacitor. In order to reduce the common mode voltage and high frequency leakage current the active common mode damper applies to the PWM inverter system the compensated voltage of which the amplitude is the same as the common mode voltage and of which the polarity is opposite to the common mode voltage. Simulated using P-SPICE and experimental results show that common-mode voltage damper makes contributions to reducing a high frequency leakage current and common-mode voltage.

  • PDF

A Switching Technique for Common Mode Voltage Reduction of PWM-Inverter Induction Motor Drive System Using TMS320F240 (TMS320F240을 이용한 PWM 인버터 유도전동기 구동 시스템의 전도노이즈 저감을 위한 스위칭 기법)

  • 박규현;김이훈;원충연;김규식;최세완;함년근
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.89-97
    • /
    • 2003
  • High frequency common mode voltage produced by PWM inverter fed Induction motor is a major cause of conducted EMI, creation motor ground currents, bearing currents and other harmful products. The zero switching states of inverter control invoke large in comparison with the non-zero switching state of Inverter control. We proposed a common mode voltage reduction method based on sinusoidal PWM technique. PWM signal are generated by comparing respective sinusoidal reference signal with three triangular carrier wave displaced of 120$^{\circ}$. Simulation and experimenta1 result show that common mode voltages in the proposed PWM technique are reduced by approximate 66% more than conventional FWM technique.

A Study on the Reduction of high frequency leakage current in PWM inverter fed Induction Motor (PWM 인버터로 구동된 유도전동기의 누설전류 억제에 관한 연구(II) -능동형 커먼 모드 전압 감쇄기를 이용한 고주파 누설전류 억제-)

  • 성병모;류도형;박성준;김철우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.5
    • /
    • pp.443-450
    • /
    • 2000
  • A PWM inverter for an induction motor often has a problem with a high frequency leakage current that flows through stray capacitors between stator windings and a motor frame to ground. This paper proposes a new type of Active Common Mode Voltage Canceler circuit for the reduction of common mode voltage and high frequency leakage current generated by the PWM VSI-fed induction motor drives. The compensating voltage applied by the common made voltage canceler has the same amplitude as, hut the opposite polarity to, the common mode voltage by PWM Inverter. Therefore, common mode voltage and high frequency leakage current can be canceled. The proposed circuit consists of four-level half-bridge inverter and common-mode transformer. Simulated and experimental results show that common mode voltage canceler makes significant contributions to reducing a high frequency leakage current.

  • PDF

Reduction of common mode voltage and high frequency leakage current generated by the PWM voltage source inverter using common mode voltage damper (능동보조회로를 이용한 전압형 PWM 인버어터 시스템에서의 커먼 모드전압과 고주파 누설전류 억제방법에 관한 연구)

  • 전진휘;박성준;김광태;김철우
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.373-376
    • /
    • 1999
  • This paper propose a "common mode voltage damper" that is capable of reducing the common mode voltage produced in the PWM VSI. An push-pull circuits and high frequency leakage current damper[1] are incorporated into the "common mode voltage damper", the design method of which is presented. Effect of "common mode voltage damper" is simulated in this paper verifies the viability and effectiveness in 2.2kW induction motor drive using IGBT inverter. Simulated results show that "common mode voltage damper" makes significant contributions to reducing a high frequency leakage current.ducing a high frequency leakage current.

  • PDF

A Study on the Simulation method for the common-mode voltage and current in the voltage fed PWM inverter system (PWM 인버터로 구동된 유도전동기의 누설전류 억제에 관한 연구(I))

  • 전진휘;이재호;이상훈;김철우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.246-253
    • /
    • 2000
  • 전동기의 제어기법과 제어기 등의 발달로 유도전동기는 산업용으로 널리 보급되고 있으며, 유도전동기를 고효율로 제어하기 위하여 PWM 인버터가 널리 사용되고 있다. 그리고 IGBT와 같은 고속 스위칭 소자의 발달로 인해 전압형 PWM 인버터의 스위칭 주파수가 증가가 가능하게 됐으며, 그로 인해 매우 우수한 동작 특성을 가지게 되었다. 그러나 고속 스위칭은 전압과 전류의 급격한 변화로 인해 매 스위칭마다 발생하는 고주파 성분의 커먼 모드전압과 전류를 발생하게 되고 이들은 베어링 전류와 축전압, 전도 및 방사 EMI, 기기의 절연수명 단축, 등의 악영향을 유발한다. 본 연구에서는 이러한 커먼 모드 전압과 전류에 대한 시스템 레벨 해석이 가능한 시뮬레이션 기법에 대해 실제 측정과 시뮬레이션을 통해 검정하였다. 이를 통해서 커먼 모드 전압과 전류가 PWM 인버터 시스템의 각 부에 미치는 영향을 쉽게 확인 할 수 있으며, 커먼 모드 전압과 전류의 저감을 위해 추가될 수 있는 부가적인 보조회로의 영향에 대해서도 제시된 시뮬레이션 기법을 통해 확인 할 수 있다.

  • PDF

Analysis of Common Mode Voltages at Diode Rectifier/Z-Source Inverter System (다이오드 정류기/Z-소스 인버터 시스템의 공통모드 전압 해석)

  • Tran, Quang-Vinh;Chun, Tae-Won;Lee, Hong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.285-292
    • /
    • 2009
  • In this paper, when ac motors are driven by the diode rectifier/Z-source inverter system, the common-mode voltages of system are analyzed in details under both the shoot-through state and non-shoot-through state through equivalent circuits. Then a modified space vector modulation strategy is suggested for attenuating the negative common-mode voltage by eliminating the zero voltage vector, and also controlling the shoot-through time. Through the simulation studies with PSIM and experiments with 32-bit DSP, it is verified that the negative common-mode voltage can be reduced by more than 50%.

Technique of Common Mode Voltage and Conducted EMI Reduction using Nonzero-vector State in SVPWM Method (SVPWM방식에서의 영벡터 제거에 의한 커먼모드 전압 및 전도성 EMI 저감 기법)

  • Hahm Nyon-Kun;Kim Lee-Hun;Jeon Kee-Young;Chun Kwang-Su;Won Chung-Yuen;Han Kyung-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.507-515
    • /
    • 2004
  • With the advent of fast power devices, the high dv/dt voltage produced by PWM inverts have been found to cause EMI noise, shaft voltage and bearing current. This paper describes the application of newly developed Conducted EMI reduction SVPWM technique in induction motor drives. The newly developed common mode voltage reduction SVPWM technique don't use any zero-vector states for inverter control, hence it can restrict the common mode voltage more than conventional PWM technique. The validity of the proposed technique by software approach is verified through simulation and experimental results.

Elimination of a Common Mode Voltage Pulse in Converter/Inverter System Modifying Space-Vector PWM Method (공간전압벡터 PWM을 이용한 컨버터/인버터 시스템에서의 커먼 모드 전압 펄스 제거)

  • Lee, Hyeon-Dong;Lee, Yeong-Min;Seol, Seung-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.2
    • /
    • pp.89-96
    • /
    • 1999
  • This paper proposes a common-mode voltage reduction method base on SVPWM(Space-Vector Pulsewidth Modulation) in three phase PWM converter/inverter system. By shifting the active voltage vector of inverter and aligning this to the active vector of converter, it is possible to eliminate a common-mode voltage pulse in one control period. Since the proposed PWM method maintains the active voltage vector, it does not affect the control performance of PWM converter/inverter system. Without any extra hardware, overall common mode voltage dv/dt and conrresponding leakage current can be reduced to two-third of the conventional three phase symmetric SVPWM scheme.

  • PDF

A Method for Reducing the Residual Voltage of Hybrid SPD Circuit Using Choke Coil (초크코일을 이용한 SPD 조합회로의 잔류전압 저감기법)

  • Cho, Sung-Chul;Eom, Ju-Hong;Lee, Tae-Hyung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.96-101
    • /
    • 2007
  • Gas Discharge Tubes (GDTs) are widely used as surge protectors for communication applications due to their small internal capacitance. In these days, however, they are mostly used in combined configurations, because the sparkover voltage required to initiate the discharge process in the GDTs and the time taken for arc formation process can be large enough to damage to sensitive circuits. For GDTs with a considerably high initial residual voltage, we should limit the peak voltage using a TVS or filter. We made a hybrid SPD circuits of common-mode type and differential-mode type with the filter using common-mode choke. Also, we applied lightning impulse voltage and ring wave voltage which frequency bandwidth are different each other and verified the characteristics of hybrid SPD circuits according to waveshapes. We describe how the applied SPDs operate in protection process steps with the actual data obtained from the residual voltage measurement at each step. The experiment results show that the surge voltage reduction with the choke coil is more effective in differential-mode circuit than in common-mode circuit.

A Study on comnon-mode-driven shield for capacitive coupling active electrode (용량성 결합 능동 전극의 공통 모드 구동 차폐)

  • Lim, Yong-Gyu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.4
    • /
    • pp.201-206
    • /
    • 2012
  • The indirect-contact ECG measurement is a newly developed method for unconstrained and nonconscious measurement in daily life. This study introduced a new method of electrode circuit design developed for reducing the 60Hz power line noise observed at the indirect-contact ECG measurement. By the introduced common-mode-driven shielding, the voltage of the electrical shield surrounding the capacitive coupling electrode is maintained at the same as the common mode voltage. Though the method cannot reduce the level of common mode voltage itself, that reduces effectively the differential mode noise converted from the common mode voltage by the difference of cloth impedance between the two capacitive coupling electrode. The experiment results using the actual indirect-contact ECG showed that the 60Hz power line noise was reduced remarkably though the reduction ratio was smaller than the expected by the theory. Especially, the reduction ratio became large for the large difference of cloth. It is expected that the introduced method is useful for reducing the power line noise under condition of poor electrical grounding.