• 제목/요약/키워드: Common Electrode

검색결과 172건 처리시간 0.035초

A Low-Power Portable ECG Touch Sensor with Two Dry Metal Contact Electrodes

  • Yan, Long;Yoo, Hoi-Jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제10권4호
    • /
    • pp.300-308
    • /
    • 2010
  • This paper describes the development of a low-power electrocardiogram (ECG) touch sensor intended for the use with two dry metal electrodes. An equivalent ECG extraction circuit model encountered in a ground-free two-electrode configuration is investigated for an optimal sensor read-out circuit design criteria. From the equivalent circuit model, (1) maximum sensor resolution is derived based on the electrode's background thermal noise, which originates from high electrode-skin contact impedance, together with the input referred noise of instrumentation amplifier (IA), (2) 60 Hz electrostatic coupling from mains and motion artifact are also considered to determine minimum requirement of common mode rejection ratio (CMRR) and input impedance of IA. A dedicated ECG read-out front end incorporating chopping scheme is introduced to provide an input referred circuit noise of 1.3 ${\mu}V_{rms}$ over 0.5 Hz ~ 200 Hz, CMRR of IA > 100 dB, sensor resolution of 7 bits, and dissipating only 36 ${\mu}W$. Together with 8 bits synchronous successive approximation register (SAR) ADC, the sensor IC chip is implemented in 0.18 ${\mu}m$ CMOS technology and integrated on a 5 cm $\times$ 8 cm PCB with two copper patterned electrodes. With the help of proposed touch sensor, ECG signal containing QRS complex and P, T waves are successfully extracted by simply touching the electrodes with two thumbs.

Viewing Angle Switching using Hybrid Aligned Nematic Liquid Crystal Display Driven by a Fringe-Field

  • Chin, Mi-Hyung;Jeong, Eun;Lim, Young-Jin;Kim, Jin-Ho;Srivastava, Anoop Kumar;Lee, Seung-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1386-1389
    • /
    • 2008
  • Conventional viewing angle switching electrode requires pixel division and additional liquid crystal panel. Hence the conventional viewing angle switching has low aperture ratio and high thickness. In this paper we proposed new viewing angle switching using hybrid aligned nematic mode by fringe-field electrode field (named HAN-FFS) with single liquid crystal panel. The fringe-field switching electrode is located at the bottom, and the additional common electrode is located at the top of the cell to control viewing angle. The proposed device is free from additional liquid crystal panel and pixel division. Consequently, the suggested structure has not only high aperture ratio but also show an excellent potential for viewing angle switching.

  • PDF

FFS모드 LCD의 투과율 향상을 위한 전극 구조 개선 (Improvement of Electrode Structure of FFS Mode LCD for Obtaining High Transmittance)

  • 김봉식;오현민;박우상
    • 한국전기전자재료학회논문지
    • /
    • 제24권4호
    • /
    • pp.309-313
    • /
    • 2011
  • In this study, we proposed a novel electrode structure for the fringe field switching (FFS) mode LCD and performed a three-dimensional computer simulation to calculate the optical transmittance for the new structure. In the simulation Erickson-leslie equation and Berreman $4{\times}4$ matrix were used for obtaining the director distribution profiles of liquid crystal molecules and the electro-optical characteristics, respectively. Considering the complexity of the motional equation of the liquid crystal molecules, FDM (finite difference method) was used as a numerical method. From the results, We revealed that the light transmission of the newly designed pixel structure is expended to the edge of the pixel electrode. We also confirmed that the light transmittance increased more than 13% compared to that of the conventional electrode structure.

Synthesis of a New Hexadendates Schiff's Base and Its Application in the Fabrication of a Highly Selective Mercury(II) Sensor

  • Ganjali, M.R.;Norouzi, P.;Alizadeh, T.;Salavati-Niasari, M.
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권1호
    • /
    • pp.68-72
    • /
    • 2007
  • A new PVC membrane potentiometric sensor that is highly selective to Hg2+ ions was prepared, using bis(2-hydroxybenzophenone) butane-2,3-dihydrazone (HBBD) as an excellent hexadendates neutral carrier. The sensor works satisfactorily in the concentration range of 1.0 × 10-6 to 1.0 × 10-1 mol L-1 (detection limit 4 × 10-7 mol L-1) with a Nernstian slope of 29.7 mV per decade. This electrode showed a fast response time (~8 s) and was used for at least 12 weeks without any divergence. The sensor exhibits good Hg2+ selectivity for a broad range of common alkali, alkaline earth, transition and heavy metal ions (lithium, sodium, potassium, magnesium, calcium, copper, nickel, cobalt, zinc, cadmium, lead and lanthanum). The electrode response is pH independent in the range of 1.5-4.0. Furthermore, the developed sensor was successfully used as an indicator electrode in the potentiometric titration of mercury ions with potassium iodide and the direct determination of mercury in some binary and ternary mixtures.

Modeling and performance evaluation of a piezoelectric energy harvester with segmented electrodes

  • Wang, Hongyan;Tang, Lihua;Shan, Xiaobiao;Xie, Tao;Yang, Yaowen
    • Smart Structures and Systems
    • /
    • 제14권2호
    • /
    • pp.247-266
    • /
    • 2014
  • Conventional cantilevered piezoelectric energy harvesters (PEHs) are usually fabricated with continuous electrode configuration (CEC), which suffers from the electrical cancellation at higher vibration modes. Though previous research pointed out that the segmented electrode configuration (SEC) can address this issue, a comprehensive evaluation of the PEH with SEC has yet been reported. With the consideration of delivering power to a common load, the AC outputs from all segmented electrode pairs should be rectified to DC outputs separately. In such case, theoretical formulation for power estimation becomes challenging. This paper proposes a method based on equivalent circuit model (ECM) and circuit simulation to evaluate the performance of the PEH with SEC. First, the parameters of the multi-mode ECM are identified from theoretical analysis. The ECM is then established in SPICE software and validated by the theoretical model and finite element method (FEM) with resistive loads. Subsequently, the optimal performances with SEC and CEC are compared considering the practical DC interface circuit. A comprehensive evaluation of the advantageous performance with SEC is provided for the first time. The results demonstrate the feasibility of using SEC as a simple and effective means to improve the performance of a cantilevered PEH at a higher mode.

FFS 모드의 공통전극과 화소전극 사이의 절연층 두께에 따른 전기광학 특성 (Electro-Optic Characteristics of the Fringe Field Switching (FFS) Mode Depending on Thickness of Passivation Layer between Pixel and Common Electrodes)

  • 정준호;하경수;임영진;유일수;정연학;유재진;김경현;이승희
    • 한국전기전자재료학회논문지
    • /
    • 제22권7호
    • /
    • pp.589-594
    • /
    • 2009
  • We have studied electro-optic characteristics as a function of passivation thickness existing between common electrode and pixel electrodes in the fringe-field switching (FFS) mode using the LC with positive dielectric anisotropy. A steep increase in the transmission is observed with increase in the passivation layer from $0.29{\mu}m$ to $1.09{\mu}m$ and thereafter it almost saturates over the $1.09{\mu}m$ of passivation layer. This saturation is mainly associated with correlation between transmittance at the center region of pixel electrode and at the center region between pixel electrodes. From the results, optimal thickness of passivation layer can be defined.

Real-time Detection of Trace Copper in Brain and Kidney of Fish for Medical Diagnosis

  • Yang, Young Kyun;Pack, Eun Chul;Lee, Seung Ha;Yoo, Hai-Soo;Choi, Dal Woong;Ly, Suw Young
    • Toxicological Research
    • /
    • 제30권4호
    • /
    • pp.311-316
    • /
    • 2014
  • For the detection of trace copper to be used in medical diagnosis, a sensitive handmade carbon nanotube paste electrode (PE) was developed using voltammetry. Analytical optimized conditions were found at 0.05 V anodic peak current. In the same conditions, various common electrodes were compared using stripping voltammetry, and the PE was found to be more sharply sensitive than other common electrodes. At optimum conditions, the working ranges of $3{\sim}19{\mu}gL^{-1}$ were obtained. The relative standard deviation of $70.0{\mu}gL^{-1}$ was determined to be 0.117% (n = 15), and the detection limit (S/N) was found to be $0.6{\mu}gL^{-1}$ ($9.4{\times}10^{-9}M$). The results were applied in detecting copper traces in the kidney and the brain cells of fish.

Effect of the Plasma-assisted Patterning of the Organic Layers on the Performance of Organic Light-emitting Diodes

  • Hong, Yong-Taek;Yang, Ji-Hoon;Kwak, Jeong-Hun;Lee, Chang-Hee
    • Journal of Information Display
    • /
    • 제10권3호
    • /
    • pp.111-116
    • /
    • 2009
  • In this paper, a plasma-assisted patterning method for the organic layers of organic light-emitting diodes (OLEDs) and its effect on the OLED performances are reported. Oxygen plasma was used to etch the organic layers, using the top electrode consisting of lithium fluoride and aluminum as an etching mask. Although the current flow at low voltages increased for the etched OLEDs, there was no significant degradation of the OLED efficiency and lifetime in comparison with the conventional OLEDs. Therefore, this method can be used to reduce the ohmic voltage drop along the common top electrodes by connecting the top electrode with highly conductive bus lines after the common organic layers on the bus lines are etched by plasma. To further analyze the current increase at low voltages, the plasma patterning effect on the OLED performance was investigated by changing the device sizes, especially in one direction, and by changing the etching depth in the vertical direction of the device. It was found that the current flow increase at low voltages was not proportional to the device sizes, indicating that the current flow increase does not come from the leakage current along the etched sides. In the etching depth experiment, the current flow at low voltages did not increase when the etching process was stopped in the middle of the hole transport layer. This means that the current flow increase at low voltages is closely related to the modification of the hole injection layer, and thus, to the modification of the interface between the hole injection layer and the bottom electrode.

생체 전위 측정에서 2-전극 차동 증폭 시스템과 2-전극 비차동 증폭 시스템의 비교 (Comparison between a differential and a non-differential amplifier system with two electrodes in bio-potential measurement)

  • 강대훈;이충근;이상준;이명호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1977-1978
    • /
    • 2008
  • In this paper, we compare performance of common-mode rejection between a differential and a non-differential amplifier system with two electrodes. A differential amplifier system is constant for common-mode rejection ratio(CMRR) on the frequency domain. But a non-differential amplifier's CMRR is determined by $Z_{FB}/Z_e$ ($Z_{FB}$ ; feedback impedance, $Z_e$; electrode impedance). There is trade-off between a non-differential amplifier's CMRR and its differential input impedance. And a non-differential amplifier system has some advantages for a bio-potential measurement with two electrodes because a designer can control the impedance between the body and system's common.

  • PDF

수변전설비에서 접지시스템의 공결점의 위치에 따른 임펄스 응답특성 (Impulse Response Characteristics of the Grounding Systems with respect to the Common-Connection Position in Power Utility System)

  • 이복희;엄주홍;김성원;심판섭;이승칠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2149-2151
    • /
    • 1999
  • This paper describes the impulse response characteristics of the grounding systems in power utility system. Several regulations regarding to electric power equipments, services and managements require that the groundings of class 1 ($E_1$) and class 2 ($E_2$) must be connected at the common point in grounding systems. In addition, the grounding for arrester ($E_{LA}$), which belongs to the grounding of class 1, should be connected at the same point. However, there is no method and position of common-connection at anywhere. In this work, when the impulse current was injected through the grounding conductor for arrester, the investigations measuring and analyzing potential rises induced at the common connection point and other grounding conductors were conducted. The experiments were carried out in the conditions of the grounding conductor of 25m long and the near or remote common connection from ground electrode. The lightning impulse current was applied so as to simulate the on-set of arrester due to lightning and/or switching surges.

  • PDF