• Title/Summary/Keyword: Color and fluorescence

Search Result 169, Processing Time 0.025 seconds

Variation and Sex-limited Expression of Fluorescent Color by Ultraviolet Spectrum on the Silkworm Cocoon (누에고치의 분광성에 관한 계통별 변이 및 한성적 발현)

  • 한명세
    • Journal of Sericultural and Entomological Science
    • /
    • v.39 no.1
    • /
    • pp.22-29
    • /
    • 1997
  • Ultraviolet weavelength (UV) of 366 nm produced clearer fluorescent dolor than that of 254 nm for the inspection of silkworm cocoons. Fluorescent color of silkworm cocoons varied in color, appears no relationship with the natural color under the normal light. Uniformity of fluorescent color was improved by selection of blue or yellow line from wild types. Blue and yellow, located at the opposite poles on the color solid and L*a*b* color system, confirmed as pure standard of fluorescent color in the silkworm races for commercial white cocoons. the cocoons with blue fluorescence occupied as high as 1.7 to 8.6 times than those with yellow in the Japanese silkworm races. Fluorescence of silkworm cocoon was not affected by forced flow dry at 70$^{\circ}C$ for 6 hrs. While the Japanese races revealed no sexual difference in fluorescent color, sex-dependence of the color was common in the Chinese races for commercial white cocoon. The fluorescence of cocoon shell of Chinese races showed clear separation of blue of median color. Silkworm strain of Dc20 and Fc24 were sexualy segregated 98.8${\pm}$1.20%, 99.0${\pm}$1.00% by cocoon fluorescence, as that of 99.3${\pm}$0.44% by typical larval marking of sex-limited inheritance. Specific expression of cocoon fluorescence, applicable to breeding of simple discrimination of sex for Chinese races, inspected thoroughly on the surface and inner layer of cocoon shell.

  • PDF

A Multi-detection Fluorescence Dye with 5-ALA and ICG Using Modified Light Emitting Diodes

  • Yoon, Kicheol;Kim, Eunji;Kim, Kwanggi;Lee, Seunghoon;Yoo, Heon
    • Current Optics and Photonics
    • /
    • v.3 no.3
    • /
    • pp.256-262
    • /
    • 2019
  • Extensive tumor resection accompanied by radiotherapy and chemotherapy is the standard of care for malignant gliomas. However, there is a significant obstacle to the complete resection of the tumor due to the difficulty of distinguishing tumor and normal brain tissue with a conventional surgical microscope. Recently, multiple studies have shown the possibility of fluorescence-guided surgery in malignant gliomas. The most used fluorescence dyes for brain tumor surgery are 5-aminolevulinic acid (5-ALA) and indocyanine green (ICG). In this paper, a new fluorescence guided operation system, which can detect both 5-ALA and ICG fluorescent images simultaneously, is presented. This operation system consists of light emitting diodes (LEDs) which emits 410 nm and 740 nm wavelengths. We have performed experiments on rats in order to verify the operation of the newly developed operation system. Oral administration and imaging were performed to observe the fluorescence of 5-ALA and ICG fluorescence in rats. When LEDs at wavelengths of 410 nm and 740 nm were irradiated on rats, 628 nm wavelength with a violet fluorescence color and 825 nm wavelength with a red fluorescence color were expressed in 5-ALA and ICG fluorescent material, respectively, thus we were able to distinguish the tumor tissues easily. Previously, due to the poor resolution of the conventional surgical microscope and the fact that the color of the vein is similar to that of the tumor, the tumor resection margin was not easy to observe, thus increasing the likelihood for cancer recurrence. However, when the tumor is observed through the fluorescence guided operation system, it is possible to easily distinguish the color with the naked eye and it can be completely removed. Therefore, it is expected that surgical removal of cancerous tumors will be possible and surgical applications and surgical microscopes for cancer tumor removal surgery will be promising in the future.

Development of the Fluorescence Endoscope System with Dual Light Source Apparatus (복합 광원을 갖는 형광 내시경 개발)

  • Bae, Soo-Jin;Kang, Uk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.222-226
    • /
    • 2007
  • We suggest the fluorescence endoscope system that has light source apparatus providing selectable white or excitation light. White light source generates normal color images and is easily switched over to excitation light with the wide spectrum range from 380 nm to 580 nm. 5-ALA is deposited selectively in the abnormal tissue like cancer and causes fluorescence in the red spectrum range when excited by blue spectrum range. In addition, the others of excitation light make the color background image by reflected light to allow accurate orientation and visualization of the abnormal tissue and around. According to clinical studies, the fluorescence intensity contrast that defines the fluorescence intensity of lesion over the fluorescence intensity of around has more than 2 in tumour. Proposed system is useful and objective way in early diagnosis. Furthermore, it can be used in the biopsy for tumour classification at the highest fluorescence intensity point.

An Overview of Remote Sensing of Chlorophyll Fluorescence

  • Xing, Xiao-Gang;Zhao, Dong-Zhi;Liu, Yu-Guang;Yang, Jian-Hong;Xiu, Peng;Wang, Lin
    • Ocean Science Journal
    • /
    • v.42 no.1
    • /
    • pp.49-59
    • /
    • 2007
  • Besides empirical algorithms with the blue-green ratio, the algorithms based on fluorescence are also important and valid methods for retrieving chlorophyll-a concentration in the ocean waters, especially for Case II waters and the sea with algal blooming. This study reviews the history of initial cognitions, investigations and detailed approaches towards chlorophyll fluorescence, and then introduces the biological mechanism of fluorescence remote sensing and main spectral characteristics such as the positive correlation between fluorescence and chlorophyll concentration, the red shift phenomena. Meanwhile, there exist many influence factors that increase complexity of fluorescence remote sensing, such as fluorescence quantum yield, physiological status of various algae, substances with related optical property in the ocean, atmospheric absorption etc. Based on these cognitions, scientists have found two ways to calculate the amount of fluorescence detected by ocean color sensors: fluorescence line height and reflectance ratio. These two ways are currently the foundation for retrieval of chlorophyll-a concentration in the ocean. As the in-situ measurements and synchronous satellite data are continuously being accumulated, the fluorescence remote sensing of chlorophyll-a concentration in Case II waters should be recognized more thoroughly and new algorithms could be expected.

Highly Sensitive Fluorescence Probes for Organic Vapors: On/off and Dual Color Fluorescence Switching

  • An, Byeong-Kwan;Kwon, Soon-Ki;Park, Soo-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.10
    • /
    • pp.1555-1559
    • /
    • 2005
  • High-performance fluorescent probes which exhibit either on/off or dual color fluorescence switching in response to the presence of organic vapors with a rapid response, a high sensitivity and a high-contrast on/off signaling ratio were demonstrated on the basis of the vapor-controlled AIEE phenomenon.

Solvatochromic Fluorescence Behavior of 8-Aminoquinoline-Benzothiazole: A Sensitive Probe for Water Composition in Binary Aqueous Solutions

  • Kim, Young-Hee;Youk, Jin-Soo;Kim, So-Hee;Chang, Suk-Kyu
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.1
    • /
    • pp.47-50
    • /
    • 2005
  • Solvatochromic fluorescence behavior of 8-aminoquinoline based benzothiazole derivative in varying solvent systems has been investigated. Benzothiazole appended 8-aminoquinoline 3 showed distinctive fluorescence color changes depending upon the solvent polarities and the fluorescence color changes occurred over relatively wide span in visible region from 486 nm to 598 nm which can be detected with naked eye. Compound 3 also exhibited significant spectral shifts in ${\lambda}_{em}$ as a function of water composition in binary aqueous solvent systems. The changes are due to the specific interaction of 3 by hydrogen bonding with water as well as general solvent effect. The observed solvatochromic fluorescence characteristics of 3 could be used as a new probe for the micro-environmental polarity changes as well as a sensitive sensor for the determination of water composition in binary aqueous solutions.

Measurements of Temperature and Flow Fields with Sub-Millimeter Spatial Resolution Using Two-Color Laser Induced Fluorescence (LIF) and Micro-Particle Image Velocimetry (PIV)

  • Kim Hyun Jung
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.716-727
    • /
    • 2005
  • Comprehensive measurements for velocity and temperature fields have been conducted. A Micro PIV 2-color LIF system have been setup to measure the buoyancy driven fields in a 1-mm heated channel with low Grashof-Prandtl numbers [$86]. Fluorescence microscopy is combined with an MPIV system to obtain enough intensity images and clear pictures from nano-scale fluorescence particles. The spatial resolution of the Micro PIV system is $75{\mu}m\;by\;67{\mu}m$ and error due to Brownian motion is estimated $1.05\%$. Temperature measurements have achieved the $4.7\;{\mu}m$ spatial resolution with relatively large data uncertainties the present experiment. The measurement uncertainties have been decreased down to less than ${\pm}1.0^{\circ}C$ when measurement resolution is equivalent to $76\;{\mu}m$. Measured velocity and temperature fields will be compared with numerical results to examine the feasibility of development as a diagnostic technique.

Dyeing of High Strength and High Molecular Weight Polyethylene Fiber Using Super Hydrophobic Fluorescence Dyes (초소수성 형광염료에 의한 고강도/고분자량폴리에틸렌섬유의 염색)

  • Kim, Taekyeong;Park, Jihoon;Lee, Junheon;Kim, Taegun
    • Textile Coloration and Finishing
    • /
    • v.29 no.4
    • /
    • pp.223-230
    • /
    • 2017
  • Three super hydrophobic fluorescence dyes were selected to dye high molecular weight polyethylene fiber and their molar absorptivity, emission spectrum, and quantum yield were measured. From the results of color strength on the fiber, all the three dyes exhibited linear increase according to the dye concentration and Fluoro3 dye showed the highest color strength among them. Emission strength of the fluorescence dyes on the fiber was investigated according to the dye concentrations. The emission was increased with the increase of the dye concentration at relatively low dye concentration and then after showing the maximum emission strength the emission was decreased at higher dye concentrations. The highest emission was obtained in Fluoro2 dye. Color fastness to washing and rubbing was generally good enough, however, especially to light, only Fluoro3 dye exhibited rating 3 acceptable practically and Fluoro1 and 2 was ratings 1 which is unacceptable level.

Radiation induced Chromosome aberration in human Iymphocyte detected by Fluorescence in sifu hybridization (FISH(Fluorescence in situ hybridization)를 이용하여 분석한 방사선에 의해 유발된 림프구의 염색체 이상)

  • 정해원;손은희;기혜성;하성환
    • Environmental Mutagens and Carcinogens
    • /
    • v.16 no.2
    • /
    • pp.88-96
    • /
    • 1996
  • Fluorescence in situ hybridization (FISH) with the DNA probe for human chromosome 4 was used to analyse in vitro radiation induced chromosome rearrangement in peripheral lymphocyte. Translocations, dicentrics, acentrics and color junctions involving the painted chromosome were scored according to the Protocol for Aberration Identification and Nomenclature Terminology (PAINT) system. The frequency of chromosome rearrangements including reciprocal translocation, dicentric, acentric fragment and color junction increased with radiation dose. The frequency of dicentric chromosome reduced by the fixation time following irradiation, whereas that of translocation was relatively persistent. The applicability of FISH for scoring stable translocation for biological dosimetry was demonstrated.

  • PDF

Fabrication and Performance Investigation of Surface Temperature Sensor Using Fluorescent Nanoporous Thin Film II (형광 나노 포러스 박막을 이용한 표면 온도 센서의 제작 및 성능 연구 II)

  • Kim, Hyun Jung;Yoo, Jaisuk;Park, Jinil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.12
    • /
    • pp.674-678
    • /
    • 2013
  • We present a non-invasive technique to the measure temperature distribution in nano-sized porous thin films by means of the two-color laser-induced fluorescence (2-LIF) of rhodamine B. The fluorescence induced by the green line of a mercury lamp with the makeup of optical filters was measured on two separate color bands. They can be selected for their strong difference in the temperature sensitivity of the fluorescence quantum yield. This technique allows for absolute temperature measurements by determining the relative intensities on two adequate spectral bands of the same dye. To measure temperature fields, Silica (SiO2) nanoporous structure with 1-um thickness was constructed on a cover glass, and fluorescent dye was absorbed into these porous thin films. The calibration curves of the fluorescence intensity versus temperature were measured in a temperature range of $10-60^{\circ}C$, and visualization and measurement of the temperature field were performed by taking the intensity distributions from the specimen for the temperature field.