• Title/Summary/Keyword: Cold and hot pattern

Search Result 62, Processing Time 0.025 seconds

An Analysis on the Spatial Pattern of Local Safety Level Index Using Spatial Autocorrelation - Focused on Basic Local Governments, Korea (공간적 자기상관을 활용한 지역안전지수의 공간패턴 분석 - 기초지방자치단체를 중심으로)

  • Yi, Mi Sook;Yeo, Kwan Hyun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.1
    • /
    • pp.29-40
    • /
    • 2021
  • Risk factors that threaten public safety such as crime, fire, and traffic accidents have spatial characteristics. Since each region has different dangerous environments, it is necessary to analyze the spatial pattern of risk factors for each sector such as traffic accident, fire, crime, and living safety. The purpose of this study is to analyze the spatial distribution pattern of local safety level index, which act as an index that rates the safety level of each sector (traffic accident, fire, crime, living safety, suicide, and infectious disease) for basic local governments across the nation. The following analysis tools were used to analyze the spatial autocorrelation of local safety level index : Global Moran's I, Local Moran's I, and Getis-Ord's G⁎i. The result of the analysis shows that the distribution of safety level on traffic accidents, fire, and suicide tends to be more clustered spatially compared to the safety level on crime, living safety, and infectious disease. As a result of analyzing significant spatial correlations between different regions, it was found that the Seoul metropolitan areas are relatively safe compared to other cities based on the integrated index of local safety. In addition, hot spot analysis using statistical values from Getis-Ord's G⁎i derived three hot spots(Samchuck, Cheongsong-gun, and Gimje) in which safety-vulnerable areas are clustered and 15 cold spots which are clusters of areas with high safety levels. These research findings can be used as basic data when the government is making policies to improve the safety level by identifying the spatial distribution and the spatial pattern in areas with vulnerable safety levels.

Study on the mixing performance of mixing vane grids and mixing coefficient by CFD and subchannel analysis code in a 5×5 rod bundle

  • Bin Han ;Xiaoliang Zhu;Bao-Wen Yang;Aiguo Liu;Yanyan Xi ;Lei Liu ;Shenghui Liu;Junlin Huang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3775-3786
    • /
    • 2023
  • Mixing Vane Grid (MVG) is one of the most important structures in fuel assembly due to its high performance in mixing the coolant and ultimately increasing Critical Heat Flux (CHF), which avoids the temperature rising suddenly of fuel rods. To evaluate the mixing performance of the MVG, a Total Diffusion Coefficient (TDC) mixing coefficient is defined in the subchannel analysis code. Conventionally, the TDC of the spacer grid is obtained from the combination of experiments and subchannel analysis. However, the processing of obtaining and determine a reasonable TDC is much challenging, it is affected by boundary conditions and MVG geometries. In is difficult to perform all the large and costing rod bundle tests. In this paper, the CFD method was applied in TDC analysis. A typical 5 × 5 MVG was simulated and validated to estimate the mixing performance of the MVG. The subchannel code was used to calculate the TDC. Firstly, the CFD method was validated from the aspect of pressure drop and lateral temperature distribution in the subchannels. Then the effect of boundary conditions including the inlet temperature, inlet velocities, heat flux ratio between hot and cold rods and the arrangement of hot and cold rods on MVG mixing and TDC were studied. The geometric effects on mixing are also carried out in this paper. The effect of vane pattern on mixing was investigated to determine which one is the best to represent the grid's mixing performance.

Spatial modeling of mortality from acute lower respiratory infections in children under 5 years of age in 2000-2017: a global study

  • Almasi, Ali;Reshadat, Sohyla;Zangeneh, Alireza;Khezeli, Mehdi;Teimouri, Raziyeh;Naderi, Samira Rahimi;Saeidi, Shahram
    • Clinical and Experimental Pediatrics
    • /
    • v.64 no.12
    • /
    • pp.632-641
    • /
    • 2021
  • Background: Over the past few decades, various goals have been defined to reduce the mortality of children caused by acute lower respiratory infections (ALRIs) worldwide. However, few spatial studies to date have reported on ALRI deaths. Purpose: We aimed to assess the spatial modeling of mortality from ALRI in children under 5 years of age during 2000-2017 using a global data. Methods: The data on the mortality of children under 5 years old caused by ALRI were initially obtained from the official website of the World Health Organization. The income status of their home countries was also gathered from the Country Income Groups (World Bank Classification) website and divided into 5 categories. After that, in the ArcGIS 10.6 environment, a database was created and the statistical tests and related maps were extracted. The Global Moran's I statistic, Getis-Ord Gi statistic, and geographically weighted regression were used for the analyses. In this study, higher z scores indicated the hot spots, while lower z scores indicated the cold spots. Results: In 2000-2017, child mortality showed a downward trend from 17.6 per 100,000 children to 8.1 and had a clustered pattern. Hot spots were concentrated in Asia in 2000 but shifted toward African countries by 2017. A cold spot that formed in Europe in 2007 showed an ascending trend by 2017. Based on the results of geographically weighted regression test, the regions identified as the hot spots of mortality from ALRI in children under 5 years old were among the middle-income countries (R2=0.01, adjusted R2=8.77). Conclusion: While the total number of child deaths in 2000-2017 has decreased, the number of hot spots has increased among countries. This study also concluded that, during the study period, Central and Western Africa countries became the main new hot spots of deaths from ALRI.

Effect of local heating and cooling on blood flow and heart rate. (서열과 한냉 자극에 대한 반복 국소 노출이 혈류량 및 심박수에 미치는 영향)

  • 박순자
    • Korean Journal of Rural Living Science
    • /
    • v.5 no.1
    • /
    • pp.1-8
    • /
    • 1994
  • This study was conducted to examine whether there is any effect of the local body exposure to hot and cold alternate stress on the blood flow and heart rate. Environmental condition was $20^{\circ}C$ air temperature, 65% relative humidity and 0.2m/s air movement. 22~32 years old four healthy female subjects wore clothes which they felt comfort sitting on a chair. And then their left hand was immersed twice in ($42^{\circ}C$\;and\;15^{\circ}C$ water alternately. Two of the subjects (E-group) were continually exposed to above condition 12 times. While, the other two (C-group) were exposed twice only at the 1st and 12th time of E-group's exposure. The results obtained from this experiment were as follows. \circled1 The initial response of the finger blood flow in I-group to the thermal stress showed more sensitively at the post-training than pre-training. \circled2 Heart .ate was higher in hand immersion at hot water ($42^{\circ}C$) than at cold water ($15^{\circ}C$) \circled3 The pattern of the blood flow of the finger and heart rate was different between E-group and C-group.

  • PDF

An Experimental Study on the Characteristics of Spray Pattern and the Mixing Performance of Unlike-impinging Split Triplet Injector(F-O-O-F) (F-O-O-F 충돌형 injector의 분무특성 및 혼합성능에 관한 실험적 연구)

  • Lee, K.J.;Moon, D.Y.;Kim, Y.
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.3
    • /
    • pp.1-8
    • /
    • 1999
  • Mixing efficiency of the unlike Impinging split triplet injector(FOOF type) were measured to investigate the effect of the momentum ratio variation. $H_2$O/kerosene were used as a propellant simulant. The maximum mixing efficiency occured at the momentum ratio 1.5 (total mixture ratio 1.89). Calculated mixing efficiency of real propellant LOX/Kerosene showed similar trend but maximum efficiency of characteristic velocity occurs at the momentum ratio 2.0(total mixture ratio 2.17). Although there exist a little discrepancy between calculated mixing efficiency based on simulant cold test and hot fire test results, this calculated mixing efficiency can be used to predict hot fire mixing efficiency.

  • PDF

Heat Shock Proteins: A Review of the Molecular Chaperones for Plant Immunity

  • Park, Chang-Jin;Seo, Young-Su
    • The Plant Pathology Journal
    • /
    • v.31 no.4
    • /
    • pp.323-333
    • /
    • 2015
  • As sessile organisms, plants are exposed to persistently changing stresses and have to be able to interpret and respond to them. The stresses, drought, salinity, chemicals, cold and hot temperatures, and various pathogen attacks have interconnected effects on plants, resulting in the disruption of protein homeostasis. Maintenance of proteins in their functional native conformations and preventing aggregation of non-native proteins are important for cell survival under stress. Heat shock proteins (HSPs) functioning as molecular chaperones are the key components responsible for protein folding, assembly, translocation, and degradation under stress conditions and in many normal cellular processes. Plants respond to pathogen invasion using two different innate immune responses mediated by pattern recognition receptors (PRRs) or resistance (R) proteins. HSPs play an indispensable role as molecular chaperones in the quality control of plasma membrane-resident PRRs and intracellular R proteins against potential invaders. Here, we specifically discuss the functional involvement of cytosolic and endoplasmic reticulum (ER) HSPs/chaperones in plant immunity to obtain an integrated understanding of the immune responses in plant cells.

Experimental measurements of R-22 two-phase friction factor in plate heat exchangers (판형열교환기에서 R-22 냉매의 이상 압력 손실계수 평가)

  • Yoo, Sang-Roon;Jeong, Ji-Rwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2273-2278
    • /
    • 2007
  • Brazed Plate Heat Exchanger (BPHE) is a type of compact plate heat exchanger with parallel corrugated plates which are brazed together in series. Each plate hascorrugation called herringbone pattern. Inside a BPHE, hot fluid and cold fluid alternate its flow direction to establish counter current flow configuration. Two-phase flow heat transfer and pressure drop of R-22 in BPHE were experimentally measured in this study. In the present experiments, single-phase region and two-phase region coexist in a BPHE. Therefore, the inside of a BPHE have to be divided into single phase region and two phase region and analyzed accordingly. The results from the single phase flow analysis are then extended to the two phase flow analysis to correlate the condensation and evaporation heat transfer and pressure drop for the refrigerant R-22 in the BPHEs. Previous models for two- phase friction factor have been compared with the present experimental results.

  • PDF

Paradigm Shift of Global Market and Pattern of Technology Innovation for Automotive Steel Sheets (자동차용 강판시장의 글로벌 패러다임 변화 및 기술혁신 패턴)

  • Jung, Kyung-Hee
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.25 no.4
    • /
    • pp.476-489
    • /
    • 1999
  • This paper is concerned with the deployment of core technologies for automotive steel sheets, based on the structural change of global market. The main tasks of automotive industry are to ensure the energy consumption, environmental regulations, and driving safety. With social and legal requirements, this study analyzes the market creation processes with technological innovations for hot rolled, cold rolled and galvanized steel sheets during the 20th century. It has been proven that the leading country in the steel industry was also that in the automotive. The purchaser-supplier relations of sheet materials are then patternized in the regional markets of the United States and Japan, who share nearly 50% of market in the world. According to the paradigm shift of globalization, the balance of power in Porter's 5 forces has been moved to the buyers', and both industries pursue Win-Win strategies such as the PNGV(Partnership for a New Generation of Vehicles ) and design-in system with the competition.

  • PDF

Velocity Measurement of PIV Using a General Light Source (일반 광원을 이용한 PIV의 속도 측정)

  • 이교태
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.559-564
    • /
    • 1999
  • A particle image velocimetry is the representative technique for measuring flow velocities at whole field simultaneously. The present study adopted the PTV method for velocity acquisition in a square enclosure with initially isothermal fluid by using a general lamp-based sheet light source. The enclosure was composed of hot and cold vertical wall and was confined by two horizon-tal adiabatic walls. The drift velocities were measured and the drift was visualized by PTV for a rayleigh number of 5.28{\times}10^8.$ Obtained instant simulataneous velocity vectors show flow pattern and the result of horizontal velocity profile agree well with the numerical result.

  • PDF

Thermal Distribution of Bi-Te Thermoelectric Module with the thickness of Polymer Sheet (고분자 필름의 두께변화에 따른 Bi-Te계 열전모듈의 열분포 특성)

  • Byeon, Jong-Bo;Kim, Bong-Seo;Park, Soo-Dong;Lee, Hee-Woong;Kim, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1675-1677
    • /
    • 2005
  • In case of attaching thermoelectric module and heat source, the polymer sheet is attached on the $AL_{2}O_3$ plate, which Is cold and hot side of thermoelectric module, in order to enhance mechanical safty of the system. It is impossible to calculate the exact distribution of temperature and flow pattern of inner gap of thermoelectric module. Therefore CFD(Computational Fluid Dynamics) analysis was executed to determine the thermo-fluid phenomena and distribution by Fluent. As the result of these analysis, heat transfer was dominated by conduction and the difference of temperature was linear distribution according to the thickness of polymer sheet.

  • PDF