• Title/Summary/Keyword: Co-60 ${\gamma}-radiation$

Search Result 344, Processing Time 0.03 seconds

An ESR Study of Amino Acid and Protein Free Radicals in Solution Part Ⅴ. an ESR Study of Gamma-Irradiated Lysozyme in Frozen Aqueous Solutions

  • Sun Joo Hong;L. H. Pitte
    • Journal of the Korean Chemical Society
    • /
    • v.16 no.1
    • /
    • pp.40-45
    • /
    • 1972
  • An electron spin resonance study has been made on lysozyme in. frozen aqueous solutions irradiated with $_{60}Co$ r-rays in air at $77^{circ}K.$ Water resonances are dominant when the concentration and the temperature are both below 20% and $130^{circ}K$ respectively. More solute radicals are produced in the solution of higher concentration. Majority of the solute radicals results from direct hit of the radiation. The same types of radicals are induced at $77^{circ}K$ whether the substances are irradiated in the dry state or in frozen aqueous solution. Based on these results, it is assumed that the number of ESR centers produced by the secondary intermolecular radical reacions and stabilized in aqueous solutions may depend on the concentration of the solution, and the presence of water may facilitate the secondary radical reactions occuring in the solute molecules after heat treatment. Majority of the solute radicals above around $193^{circ}K$ are believed to react with oxygen to form peroxytype radicals. However, when the solution is subiected to heat-treatment at $265^{circ}K$ after irradiation at $195^{circ}K$ the peroxy-type resonance was not observed, suggestin that an appreciable amount of oxygen is condensed into the ice, at $77^{circ}K.$ in addition to the oxygen that has already been dissolved in solution and react with solute free radicals during the process of heat-treatment. When the solution contains $H_2O_2$, no water resonance but $HO_2$, type resonance was observed probably indicating that the radiation-induced OH radicals are trapped in $H_2O_2$ aggregates and react readily with $H_2O_2$ molecules to poroduce $HO_2$ type radicals even at $77^{circ}K.$.

  • PDF

A Study on the dose distribution and the accuracy of the system for small fields of high energy x-rays (고에너지 X-선 소조사야의 선량분포 및 계측에 관한 연구)

  • 이호남;지광수;김재휴;지영훈
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.32-44
    • /
    • 1995
  • I. 제 목 고에너지 X-선 소조사야의 선량분포 및 계측에 관한 연구 II. 연구의 목적 및 중요성 최근 수술이 어려운 뇌종양등에 대한 방사선수술법(Radiosurgery)이 관심의 대상이 되고 있다. 방사선수술법은 크게 나누어 200여개의 Co-60이 장착된 장치(Gamma Knife)를 이용하는 방법과, X-선치료기를 이용하는 방법은 몇개의 보조기구를 설치하면 가능한 매우 경제적인 방법이다. 따라서 Microtron을 이용한 방사선수술의 기초자료확보를 위하여 소조사야에 대한 선량과 선량분포의 측정 및 계산을 실시하였다. III. 연구의 내용 및 범위 Microtron으로부터 조사되는 6MV, 10MV, 21MV X-선의 지름 3cm이하 소조사야에 대한 정확한 선량 및 선량분포 자료를 확보하기 위해, 가. Microtron치료기와 보조장치등에 대한 정밀도 계측 및 평가 나. 보조 Collimator의 적당한 크기와 재료의 선택 및 설계, 제작. 다. 에너지와 조사야 크기 각각에 대한 여러측정장치(Ion chamber, Diode detector, TLD 및 Film등)를 이용한 선량 및 선량분포 측정. 라. 측정값들의 비교, 검토 및 측정된 자료에 의한 선량 및 선량분포의 계산을 수행했다. IV. 연구결과 및 활용에 대한 건의 본 연구에서 얻은 결과는 다음과 같다. 가. Microtron치료기와 보조장치등의 정확도의 허용 오차범위내에서 잘 일치하였다. 나. 보조 collimater adpator는 총 길이 24cm로 하였으며 재질로는 두랄미늄을 사용하였고, 보조 collimator는 low melting alloy를 사용하였으며 소조사야 크기의 정확도는 0.5mm이내에서 매우 잘 일치 하였다. 다. 방사선 수술법의 에너지 선택에 중요한 요소중의 하나인 penumbra는 6MV X-선에서 가장 적게 나타났으며 라. 소조사면에 대한 깊이-선량 백분율곡선은 모든 에너지에서 조사면이 작아질수록 표면으로 이동하는 경향을 보였다. 이상의 결과로부터 방사선 수술을 시행할 경우 수십억원에 이르는 장비의 도입이나 새로운 시설 없이 Microtron에서 조사되는 고에너지 X-선을 이용할 수 있을 것으로 사료된다. 또한 새로 구입한 측정기나 보조 Collimator를 이용하여 소조사야에 대한 선량측정기술을 습득함으로써 일반적인 소조사야의 방사선치료나 회전치료등에 활용할 수 있다.

  • PDF

The Radioprotection Effect of Protaetia Brevitarsis Larvae Extracts on the Reproductive in Female Rats Irradiated Gamma Ray (감마선에 조사된 암컷 흰쥐의 생식기관에 대한 흰점박이꽃무지 유충 추출물의 방사선 방호효과)

  • Jeong, Geun-Woo;Joung, Do-Young;Kim, Chang-Ju;Lee, Ji-Eun;Jeong, Sang-Hyun;Kim, Hee-Jin;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.247-255
    • /
    • 2021
  • The purpose of this study was to examine the radiation protection effect of protaetia brevitarsis larvae extracts known as antioxidant food. In this study 90 female rats were clssified in to 5 groups: NC Group, PBE Group, IR Group, PBE+IR Group and IR+PBE Group. In IR Group, 7 Gy of Co-60 gamma ray was irradiated to SD rat and protaetia brevitarsis larvae extracts were administered orally at 200 mg/kg once a day for 14 days. And then on the 1 day, 7 days, 21 days later after irradiation, changes in blood cell component, superoxide dismutase(SOD) activity, spleen index, histopathological evaluation of the ovary and uterus were observed. As a result, the PBE+IR Group (p<0.01, p<0.05) and IR+PBE Group (p<0.01, p<0.01) showed a significantly radiation protection than the IR Group in lymphocyte and red blood cell on the 21 days. It was also confirmed that SOD activity of PBE+IR Group (p<0.01) and IR+PBE Group (p<0.01) was significantly increased than the IR Group. In spleen index, PBE+IR Group (p<0.05) and IR+PBE Group (p<0.01) showed a significantly recovery than the IR Group. In histopathological observation, PBE+IR Group in the ovary and PBE+IR, IR+PBE Group in the uterus showed less inflammatory reactions of cystoplasm than the IR Group. Based on These results, It is judged that protaetia brevitarsis larvae Extracts have radiation protection effect against blood and reproductive. It is expected to be useful for research of radiation protection agent.

Calculation of the Correction Factors related to the Diameter and Density of the Concrete Core Samples using a Monte Carlo Simulation (몬테카를로 전산해석을 이용한 콘크리트 코어시료의 직경과 밀도에 따른 보정인자 계산)

  • Lee, Kyu-Young;Kang, Bo Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.503-510
    • /
    • 2020
  • Concrete is one of the most widely used materials as the shielding structures of a nuclear facilities. It is also the most generated radioactive waste in quantity while dismantling facilities. Since the concrete captures neutrons and generates various radionuclides, radiation measurement and analysis of the sample was fulfilled prior to dismantle facilities. An HPGe detector is used in general for the radiation measurement, and effective correction factors such as geometrical correction factor, self-absorption correction, and absolute detector efficiency have to be applied to the measured data to decide exact radioactivity of the sample. Correction factors are obtained by measuring data using a standard source with the same geometry and chemical states as the sample under the same measurement conditions. However, it is very difficult to prepare standard concrete sources because concrete is limited in pretreatment due to various constituent materials and high density. In addition, the concrete sample obtained by core drill is a volumetric source, which requires geometric correction for sample diameter and self absorption correction for sample density. Therefore in recent years, many researchers are working on the calculation of effective correction factors using Monte carlo simulation instead of measuring them using a standard source. In this study we calculated, using Geant4, one of the Monte carlo codes, the correction factors for the various diameter and density of the concrete core sample at the gamma ray energy emitted from the nuclides 152Eu and 60Co, which are the most generated in radioactive concrete.

An Activation Analysis of Target("used H218O") for 18FDG Synthesis (18FDG 생산용 타겟("사용 후 H218O")의 방사화 분석)

  • Kang, Bo Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.213-219
    • /
    • 2013
  • Currently, about 35 cyclotrons have been operating in South Korea. Most of them are mainly used for the synthesis of radiopharmaceuticals such as $^{18}FDG$, which is a cancer tracer for nuclear medicine. Highly enriched $H_2{^{18}}O$ containing up to 98% of $^{18}O/O$ isotope ratio is used as the target for $^{18}F$ production. The price of the highly enriched $H_2{^{18}}O$ ranges 60~70 USD/g, and all of them have been imported from foreign country in spite of the very expensive price. The target (enriched $H_2{^{18}}O$) is non-radioactive before the proton beam irradiation. But, the post-irradiation target (used $H_2{^{18}}O$) must be managed following the National Radiation Safety Regulations, because it turns into radioactive by the radioactivation of the impurities within the target. Recently, nevertheless of the fast increasing amount of used $H_2{^{18}}O$ in accordance with the increasing number of nuclear medicine cases, any activation analysis on the used $H_2{^{18}}O$ have been conducted yet in Korea. In this research, activation analysis have been conducted to confirm the specific radioactivity(Bq/g) of each radioisotopes within the used $H_2{^{18}}O$. The analysis have been done on the 3 of 20g samples collected from the used $H_2{^{18}}O$ storages at different cyclotron centers. Based on the results, it was confirmed that the "used $H_2{^{18}}O$" contains gamma emitters such as $^{56}Co$, $^{57}Co$, $^{58}Co$, and $^{54}Mn$ as well as the considerable amount of beta emitter $^3H$. It was also confirmed that the only one sample contained over exemption level of gamma emitters while the specific activity of tritium was lower than the exemption level in all samples. The specific activity of radioisotopes were measured different levels in the samples depending on the elapsed time after irradiation. Further study on the activation of the "used $H_2{^{18}}O$" is definitely necessary, nevertheless the as-is results of this research must be useful in establishing a rational "used $H_2{^{18}}O$" management protocol.

Evaluation of protective effect of peach kernel extracts on radiation-induced DNA damage in human blood lymphocytes in the single cell gel electrophoresis assay (단세포 겔 전기영동법을 이용한 사람 림프구 DNA 손상에 대한 복숭아씨 추출물의 방사선 방어효과 평가)

  • Kim, Jin-Kyu;Park, Tae-Won;Lee, Chang-Joo;Chai, Young-Gyu
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.2
    • /
    • pp.93-99
    • /
    • 1999
  • The alkaline single-cell gel electrophoresis (SCGE) assay, called the comet assay, has been applied to the detection of DNA damage from a number of chemical and biological factors in vivo and in vitro. The comet assay is a novel method to assess DNA single-strand breaks, alkali-labile sites in individual cells. The effect of peach kernel extracts on radiation-induced DNA damage in human blood lymphocytes was evaluated by the SCGE assay. The lymphocytes, with or without pretreatment of the extracts, were exposed to 0, 0.1, 0.3, 0.5, 1.0 and 2.0 Gy of $^{60}Co$ gamma ray. Significantly increased tail moment, which was a marker of DNA strand breaks in the comet assay, showed an excellent dose-response relationship. The treatment of the peach kernel extracts reduced the DNA damage by 30 % in irradiated groups as compared to that in non-treated control groups. The result indicates that the extracts shows radioprotective effect on lymphocyte DNA when assessed by the comet assay.

  • PDF

Radiation Sensitivity of Some Toxigenic Molds Isolated from Deteriorated Rice (변질미(變質米)에서 분리된 독소생성(毒素生成)곰팡이의 방사선(放射線) 감수성(感受性))

  • Choi, Eon-Ho;Kim, Hong-Lyour;Lee, Su-Rae
    • Korean Journal of Food Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.148-153
    • /
    • 1975
  • Seven toxigenic molds isolated from deteriorated rice in Korea, Aspergillus clavatus, Asp. flavus var. columnaris, Asp. fumigatus, Asp. ochraceus, Penicillium citrinum, Pen. implicatum, and Pen. islandicum, were examined for their sensitivity toward Co-60 gamma rays for survival. Conidia of all tested species showed survival curves of sigmoidal type, from which decimal reduction doses were found to vary in the range of $14{\sim}33$ krad, induction doses, in the range of $12{\sim}56$ krad and inactivation factors at 200 krad, in the range of $4.6{\sim}12.8$, all at a dose rate of 11.56 krad/min. Dose rate effects on the radiosensitivity of Asp. flavus and Pen. islandicum conidia indicated that the higher dose rate (11.56 krad/min) caused decreases in decimal reduction doses as compared with the lower dose rate (2.67 krad/min).

  • PDF

Biochemical Effect on Potato Tubers Irradiated by Gamma-Ray at Sprout-Inhibition Dose (방사선 조사에 의한 감자 발아 억제시 생화학적 효과)

  • Jeon, J.H.;Byun, S.M.;Chang, Y.S.P.;Chung, K.H.;Cho, H.O.
    • Applied Biological Chemistry
    • /
    • v.28 no.1
    • /
    • pp.28-35
    • /
    • 1985
  • Potato tubers treated at $4^{\circ}C$ for 4 weeks were irradiated with a dose of 0.12 kGy from $^{60}Co$ source and stored at $20^{\circ}C,\;70{\sim}90%$ humidity for 5 weeks. Changes of ${\alpha}-amylase$, peroxidase, indole acetic acid oxidase, indole acetic acid synthesizing enzyme activities were determined. In addition, treatment of gibberellin or indole acetic acid to tubers irradiated were carried out to examine reversal of sprout-inhibition of tubers irradiated. Results are as follows; 1. Irradiation by ${\gamma}-ray$ at 0. 12 kGy dose inactivated easily the enzyme activities in vitro. $D_{37}$ values obtained were 0.94, 0.36 kGy for ${\alpha}-amylase$ and peroxidase, respectively 2. Complete inhibition of the toter sprouting was resulted by the irradiation of tubers with a dose of 0.12 kGy. 3. The indole acetic acid oxidase activity increased 2 times immediately after irradiation. Meanwhile, indole acetic acid synthesizing activity decreased about $50{\sim}75%$ for 5-week storage in irradiated potatoes, whereas the activity increased about 3.5 times along with sprouting in non-irradiated tubers. 4. In morphological aspects, deformed buds with necrosis in the meristmatic tissue were developed in irradiated tubers. Treatment of gibberellin or indole acetic acid at the concentration of 100 or 20 ppm to the irradiated tubers reversed the sprout-inhibition partially. Nevertheless, the deformed buds remained without change.

  • PDF

Effect on active transport of cell membrane model which irradiated by radiation (방사선이 조사된 세포막 모델이 물질의 능동수송에 미치는 영향)

  • Ko, In-Ho;Yeo, Jin-Dong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.103-110
    • /
    • 2011
  • The effect on active transport of $K^+$ and $Na^+$ of cell membrane model which irradiated by radiation was investigated. The cell membrane model used in this experiment was a $Na^+$ type sulfonated copolymerized membrane of styrene and divinylbenezene. The initial flux of the ion was increased with increase of both $H^+$ ion concentration. In this experiment range(pH $0.5^{-3}$), the initial flux of $K^+$ which was not irradiated by radiation was found to be from $7.9{\times}10^{-4}$ to $7.49{\times}10^{-3}mole/cm^2{\cdot}h$ and that of Na+ from $10.6{\times}10^{-4}$ to $7.68{\times}10^{-3}mole/cm^2{\cdot}h$. The initial flux of $K^+$ which was irradiated by radiation was found to be from $35.0{\times}10^{-4}$ to $42.4{\times}10^{-3}mole/cm^2{\cdot}h$ and that of $Na^+$ from $52.0{\times}10^{-4}$ to $43.3{\times}10^{-3}mole/cm^2{\cdot}h$. The membrane was selective for $K^+$ and the ratio $K^+/Na^+$ was about 1.10. And the driving force of pH of irradiated membrane was significantly increased about 4-5 times than membrane which was not irradiated. As active transport of $K^+$ and $Na^+$ of cell membrane model were abnormal, cell damages were appeared at cell.

A Study on the Validation of Effective Angle of Particle Deposition according to the Detection Efficiency of High-purity Germanium Gamma-ray Detector (고순도 저마늄 감마선 검출기의 검출효율에 따른 유효입체각 검증에 관한 연구)

  • Chang, Boseok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.487-494
    • /
    • 2020
  • The distance between the source and the detector, the diameter of the detector, and the volume effect of the radiation source result in a change in solid angle at the detector entrance, which affects the determination of detection efficiency by causing a difference in path length within the detector. A typical analysis method for calculating solid angles was useful only for a source (60Co) with a simple geometric structure, so in this experiment, the distance between the detector and the source was measured by switching on for up to 25 cm with the reference point of window cap 0.5 cm. In addition, 450 and 1000 ㎖ Marinelli beaker of standard volumetric sources were closely adhered to the detector. For circular point sources co-axial with the detector, the change in the solid angle to the distance from the detector window is equal to half the square radius of the source versus the square radius of the detector, if the resulting relationship of the calculation analysis results in the detector being less than the radius of the source. Since the solid angular difference is 0.5 the result of Monte Carlo is acceptable. The relationship between detector and source distance is shown. Solid angles have been verified to decrease rapidly with distance. Measurement and simulation results for a volumetric source show a difference of ±1.01% from a distance of 0 cm and less than 4 % when the distance is reduced to 5 and 10 cm. It can be seen that the longer distance, the smaller efficiency angle, and the exponential increase in attenuation as the energy decreases, is reflected in the calculation of efficiency. Thus, the detection efficiency has proved sufficient for the use of solid angle and Monte Carlo codes.