• 제목/요약/키워드: Closed Loop Structure

검색결과 230건 처리시간 0.028초

일반공조 시스템 대비 축열조와 연동된 수직밀폐형 지열히트펌프의 냉난방 에너지 성능 및 경제성 분석 (Cooling and Heating Energy Performance and Cost Analysis of Vertical Closed-loop Geothermal Heat Pump Coupled with Heat Storage Tank Compared to Conventional HVAC System)

  • 김민지;도성록;최종민;이광호
    • 대한건축학회논문집:구조계
    • /
    • 제34권11호
    • /
    • pp.81-87
    • /
    • 2018
  • Among various types of geothermal heat pump systems, Vertical Closed-Loop Geothermal Heat Pump (VGSHP) has received increasing attention due to a variety of advantages such as the potential to be installed in a relatively small space and improved energy efficiency. In this research, the performance of VGSHP system coupled with heat storage tank was evaluated, by analyzing operational behavior of heat storage tank, the variations of heat pump energy performance due to the connection with heat storage tank, part load ratios characteristics of heat pump and the corresponding energy cost, compared to chiller and boiler based conventional system. The results of this study showed that the VGSHP system coupled with heat storage tank showed an energy saving effect of about 18% for cooling and about 73% for heating, and annual heating/cooling energy cost reduction of 43,000,000 KRW ($ 39,000), compared to the conventional air conditioning system. In addition, after considering both energy cost and initial investment cost including equipment, installation and auxiliary device expenses, payback period of approximately 11.8 years was required.

수지상 배전계통을 단일루프로 구조 변경시 신뢰도 비교 (The Comparison of Reliability for Change Single Loop Configuration in Radial Power Distribution System)

  • 이희태;김재철;김주용
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1472-1478
    • /
    • 2009
  • The domestic power distribution system is operating in an open loop mode; however, it already has a loop structure. Power distribution systems must be changed for bi-directions power supply for smart networks due to a changing of paradigm in electric power industry. The simplest bi-directions distribution networks can make it closing of normally open switch. However, bi-directions power supply is very difficulty to be operated and there are many parts which it must study. This paper presented various models that are able to change a radial system for loop structures. Further, we compared the reliability index for each model by evaluating the amount of improvement reliability required in radial power distribution system. In addition, we calculated CIC(Customer Interruption Cost) for each model by comparing and analyzing.

격자 지지구조체에 묶여있는 실린더 형 봉의 삽입위치에 따른 진동특성 (Vibration Characteristic of a Cylindrical Rod according to the Mounting Locations on the Grid Support Structure)

  • 이강희;윤경호;송기남;김재용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.515-518
    • /
    • 2006
  • A vibration test for a cylindrical rod inserted on the grid support structure was tested using the sine sweep excitation method with closed loop force control. The effect of the mounting location of a test rod on the vibration characteristics of a rod continuously supported by the full size($16{\times}16$) grid support was identified. An electromagnetic vibration shaker, non-contact displacement sensor and HP/VXI data acquisition device were used and TDAS software was also used as a data sampling and processing tools. The natural frequencies and mode shape of the test rod were consistent with the previous works of a rod vibration test with partial grids($3{\times}3,\;5{\times}5\;and\;7{\times}7$). The frequency characteristics of the rod according to the mounting location were shown clear discrepancies, but mode shapes were nearly same. As the test rod closes to the bottom clamping region of the spacer grid, peak vibration amplitudes of the rod become smaller.

  • PDF

Post-transcriptional and post-translational regulation during mouse oocyte maturation

  • Kang, Min-Kook;Han, Seung-Jin
    • BMB Reports
    • /
    • 제44권3호
    • /
    • pp.147-157
    • /
    • 2011
  • The meiotic process from the primordial stage to zygote in female germ cells is mainly adjusted by post-transcriptional regulation of pre-existing maternal mRNA and post-translational modification of proteins. Several key proteins such as the cell cycle regulator, Cdk1/cyclin B, are post-translationally modified for precise control of meiotic progression. The second messenger (cAMP), kinases (PKA, Akt, MAPK, Aurora A, CaMK II, etc), phosphatases (Cdc25, Cdc14), and other proteins (G-protein coupled receptor, phosphodiesterase) are directly or indirectly involved in this process. Many proteins, such as CPEB, maskin, eIF4E, eIF4G, 4E-BP, and 4E-T, post-transcriptionally regulate mRNA via binding to the cap structure at the 5' end of mRNA or its 3' untranslated region (UTR) to generate a closed-loop structure. The 3' UTR of the transcript is also implicated in post-transcriptional regulation through an association with proteins such as CPEB, CPSF, GLD-2, PARN, and Dazl to modulate poly(A) tail length. RNA interfering is a new regulatory mechanism of the amount of mRNA in the mouse oocyte. This review summarizes information about post-transcriptional and post-translational regulation during mouse oocyte meiotic maturation.

기계임피던스 감소기법을 이용한 회전형 전기-유압식 구동기의 모델 없는 토크제어방법 (Model-Free Torque Control of Rotary Electro-Hydraulic Actuator using Mechanical Impedance Reduction)

  • 이웅용;정완균
    • 로봇학회논문지
    • /
    • 제15권1호
    • /
    • pp.77-89
    • /
    • 2020
  • This paper proposes a simple and intuitive model-free torque-tracking control for rotary electro-hydraulic actuators. The undesirable natural-velocity-feedback effect is discussed by introducing mechanical impedance into the electro-hydraulic actuation system. The proposed model-free torque control comprises inner- and outer-loop control to achieve two control objectives. Inner-loop control reduces the mechanical impedance passively and optimally. To improve the tracking accuracy, a certain form of proportional-integral-derivative control is applied to the outer loop. The robustness of the proposed closed-loop system against external disturbances is demonstrated by transforming the two-loop control structure into a disturbance observer form. The proposed method is validated on a single joint electro-hydraulic actuator.

파라메타 오차에 강인한 독립모달공간 제어기법에 대한 연구 (A Study on the Robust Controller in Independent Modal space for Parameter Errors)

  • 황재혁;김준수;박대성;박명호
    • 소음진동
    • /
    • 제6권5호
    • /
    • pp.595-605
    • /
    • 1996
  • If the control force designed on the basis of the mathematical model with parameter errors is applied to control the actual system, the closed-loop performance of the actual system will be degraded depending on the degree of the errors, In this study, the effect of parameter errors on the robustness of several natural controls has been analyzed and compared. Every asymptoic stability condition for the natural controls has been derived using Lyapunov approach, and the characteristics of the stability conditions has also been compared. The extent of deviation of the closed-loop performance from the designed one for the natural controls is derived using operator techniques, and evaluated by numerical method. It has been found that the optimal control, acceleration feedback control, and acceleration-position feedback control among the considered natural controls would be robust one with respect to the parameter errors.

  • PDF

Generalized predictive control based on the parametrization of two-degree-of-freedom control systems

  • Naganawa, Akihiro;Obinata, Goro;Inooka, Hikaru
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.1-4
    • /
    • 1995
  • We propose a new design method for a generalized predictive control (GPC) system based on the parametrization of two-degree-of freedom control systems. The objective is to design the GPC system which guarantees the stability of the control system for a perturbed plant. The design procedure of our proposed method consists of three steps. First, we design a basic controller for a nominal plant using the LQG method and parametrize a whole control system. Next, we identify the deviation between the perturbed plant and the nominal one using a closed-loop identification method and design a free parameter of parametrization to stabilize the closed-loop system. Finally, we design a feedforward controller so as to incorporate GPC technique into our controller structure. A numerical example is presented to show the effectiveness of our proposed method.

  • PDF

Robust suboptimal regulator design for linear multivariable system

  • Lee, Jae-Hyeok;Bien, Zeungnam
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.841-846
    • /
    • 1990
  • In this study, a design method to obtain a robust suboptimal regulator for linear multivariable system is presented. This new design method is based on the optimal regulator design method using eigen-structure assignment and it uses additional cost function which represent robustness of the closed loop system. When we design the regulator using pole assignment method for linear multivariable system we have extra degree-of-freedom after assigning desired eigenvalues of the closed loop system in determining the feedback gain. So we assign additional robust suboptimal regulator. In this study we also feedback the system output for more practical applications.

  • PDF

유전알고리즘을 적용한 NCPP기반의 기계선정 방법 (An integrated process planning system through machine load using the genetic algorithm under NCPP)

  • 최회련;김재관;노형민
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.612-615
    • /
    • 2002
  • The objective of this study is to develop an integrated process planning system which can flexibly cope with the status changes in a shop floor by utilizing the concept of Non-Linear and Closed-Loop Process Planning(NCPP). In this paper, Genetic Algorithm(GA) is employed in order to quickly generate feasible setup sequences for minimizing the makespan and tardiness under an NCPP. The genetic algorithm developed in this study for getting the machine load utilizes differentiated mutation rate and method in order to increase the chance to avoid a local optimum and to reach a global optimum. Also, it adopts a double gene structure for the sake of convenient modeling of the shop floor. The last step in this system is a simulation process which selects a proper process plan among alternative process plans.

  • PDF

힐버트 변환을 이용한 주기적인 외란 및 잡음제거 (PERIODIC DISTURBANCE AND NOISE REJECTION METHOD USING HIRBERT TRANSFORM)

  • 나희승;박영진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.443-448
    • /
    • 2000
  • In this paper, we propose a novel adaptive feedforward controller for periodic disturbance and noise cancellation, with a frequency tracking capability. It can be added to an existing feedback control system without altering the original closed-loop characteristics, which is based on adaptive algorithm. We introduce novel algorithm "Constrained AFC(adaptive feedforward controller) algorithm" that increase the convergence region regardless of the delay in the closed loop system. In the algorithms, coefficients of the controller are adapted using the residuals of constrained structure which are defined in such a way that the coefficients become time invariant. The proposed algorithm not only estimate the magnitude and phase of the tonal disturbance and noise but also track the frequency of the tone, which changes in quasi-static manner. The frequency tracking algorithm uses the instantaneous frequency approach based on Hilbert transform. A number of computer simulations have been carried out in order to demonstrate the effectiveness of proposed method under various conditions.

  • PDF