• Title/Summary/Keyword: Circular Column

Search Result 327, Processing Time 0.028 seconds

Seismic performance of mixed column composed of square CFST column and circular RC column in Chinese archaized buildings

  • Xue, Jianyang;Zhou, Chaofeng;Lin, Jianpeng
    • Steel and Composite Structures
    • /
    • v.29 no.4
    • /
    • pp.451-464
    • /
    • 2018
  • This paper presents some quasi-static tests for 4 mixed columns composed of CFST column and RC column. The seismic performance and failure mode were studied under low-cyclic revised loading. The failure mode was observed under different axial compression ratios. The hysteretic curve and skeleton curve were obtained. The effects of axial compression ratio on yield mechanism, displacement ductility, energy dissipation, stiffness and strength attenuation were analyzed. The results indicate that the failure behavior of CFST-RC mixed column with archaized style is mainly caused by bending failure and accompanied by some shear failure. The axial compression ratio performs a control function on the yielding order of the upper and lower columns. The yielding mechanism has a great influence on the ductility and energy dissipation capacity of specimens. Based on the experiment, finite element analysis was made to further research the seismic performance by ABAQUS software. The variable parameters were stiffness ratio of upper and lower columns, axial compression ratio, yielding strength of steel tube, concrete strength and rebar ratio. The simulation results show that with the increase of stiffness ratio of the upper and lower columns, the bearing capacity and ductility of specimens can correspondingly increase. As the axial compression ratio increases, the ductility of the specimen decreases gradually. The other three parameters both have positive effect on the bearing capacity but have negative effect on the ductility. The results can provide reference for the design and engineering application of mixed column consisted of CFST-RC in Chinese archaized buildings.

Estimation of the Local Load-Carrying Capacities of CFCT Column to H-Beam Connections by Yield Line Model -With regard to the Tensile side of Beam flange- (인장측 보플랜지의 항복선 모델을 이용한 CFCT기둥-H형강보 접합부의 국부내력평가)

  • Kang, Hyun Sik;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.3 s.36
    • /
    • pp.525-536
    • /
    • 1998
  • This paper is concerned with a theoretical study on the local load-carrying capacities of Concrete-Filled Circular Tubular(CFCT) column to H-beam connections by yield line theory. In this paper, the three cases which are assumed the yield line are involved. The first model is a simplified yield line model. The second model is modified by x and kx factors. The last one is a Morita's model. The local load-carrying capacities of CFCT column to H-beam connections has been studied both experimentally and theoretically using the yield line theory. The purpose of this paper is to suggest the basic data for developing the non-diaphragm connection.

  • PDF

Ductility Capacity for Concrete Filled Steel Circular Tubes Reinforced by Carbon Fiber Sheets(CFSs) (탄소섬유쉬트로 보강된 콘크리트충전 원형강관기둥의 연성능력)

  • Park, Jai-Woo;Hong, Young-Kyun;Choi, Sung-Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.2
    • /
    • pp.185-195
    • /
    • 2010
  • This paper presents the experiment results for a CFT column confined by carbon fiber sheets(CFSs) under an axial load. Nine specimens were constructed and axial compression tests were conducted. The main experiment parameters were diameter-thickness ratio(D/t), reinforcing CFSa, and the attachment of a cushion gap between surface of steel tube and CFSs. The load-displacement curves of the specimens were obtained from the compression tests. Finally, it was concluded that the CFT column with a gap had grater ductility capacity improvement that the CFT column confined by CFSs.

Strengthening Effect Analysis of Circular Concrete Column Strengthened with Laminated CFS (적층성을 띤 CFS로 보강된 원형 콘크리트 기둥의 보강효과 해석)

  • 이상호;허원석
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.3
    • /
    • pp.89-100
    • /
    • 1999
  • The purpose of this study is to develop an analytic model of the concrete column strengthened with laminated CFS, and to provide a basic guideline for the strengthening design by CFS considering orthotropic properties of laminate. In this study, an analytical stress-strain model of laminated CFS is presented based on Tsai-Hill failure criterion. This model has been implemented in an algorithm which can evaluate the confinement effect of CFS. Through this algorithm, the stress-strain relationship of confined concrete is obtained and compared with experimental results of other studies. Using the constitutive relationships, section analyses of concrete column strengthened with CFS are done, and load-moment and load-curvature interaction curves are obtained. In addition, the strengthening effects of CFS according to various laminated angles are analyzed. Analytical results show that the strengthening effects of the strengthened concrete columns are significantly different in compression, flexure, and ductility according to the laminated ways. In compressive direction of principal stress shows the superiority, where an in flexural strengthening effects, [0/90]s does. In the aspect of ductility, [90]s shows the best effect.

A Study of Strength Reduction Factor Preparation for Circular Concrete Columns confined by Carbon Sheet Tube (카본시트튜브로 구속된 원형 콘크리트 기둥의 강도감소계수 제안에 관한 연구)

  • Lee, Kyoung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.6
    • /
    • pp.106-112
    • /
    • 2016
  • In this study, circular concrete column specimens confined by carbon sheet tube with different winding angles and different number of carbon sheet plies(3T, 5T and 7T) were tested to propose design equations and a strength reduction factor. Specimens were designed by 300 mm diameter and 600 mm height with $90^{\circ}{\pm}0^{\circ}$, $90^{\circ}{\pm}30^{\circ}$, $90^{\circ}{\pm}45^{\circ}$, $90^{\circ}{\pm}60^{\circ}$, $90^{\circ}{\pm}75^{\circ}$ and $90^{\circ}{\pm}90^{\circ}$ carbon fiber angles. A 10,000 kN UTM was used for compressive strength test of specimens by displacement control method with 0.01 mm/sec velocity. Estimation equations of compressive strength and ultimate strain of circular concrete column specimens confined by carbon sheet tube using a regression analysis and a strength reduction factor to apply ultimate strength design method of concrete were proposed. The strength reduction factor(${\phi}$) of circular concrete columns confined by carbon sheet tube was estimated as 0.64 by the Monte Carlo Analysis Method. Manufacture and construction process have to be perfectly managed by construction managers because the structural capacities of carbon tubes were depends on construction abilities of manufacturing operators.

Behavior of Solid Circular RC Piers without Seismic Detailing Subjected to Cyclic Lateral Load (수평 반복하중을 받는 비내진상세 RC 중실원형교각의 거동특성)

  • 김재관;김익현;임현우;전귀현
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.4
    • /
    • pp.83-95
    • /
    • 2001
  • Scale model tests were performed to investigate the seismic behavior and capacity of reinforced concrete piers that were not detailed for seismic load. The prototype pier is of solid circular section. Additional lateral reinforcing bars were not provided that might be required for the confinement. Two kinds of reinforcement details are considered for the vertical longitudinal reinforcing bars: lap spliced and continuous. In the case of lap spliced model all the longitudinal bars were lap spliced at the same height in the bottom plastic hinge zone. Three specimens were constructed and subjected to quasi-static cyclic lateral loading while the vertical load held constant. Non-ductile failure modes were observed in the test of lap spliced models but limited ductile behavior was observed in the test of a continuous longitudinal reinforcement model.

  • PDF

Experimental Study on Concrete Steel Circular Tubes Confined by Carbon Fiber Sheet under Axial Compression Loads (탄소섬유쉬트로 구속된 콘크리트충전 원형강관기둥의 단조압축실험)

  • Park, Jai-Woo;Hong, Young-Kyun;Hong, Gi-Soup;Choi, Sung-Mo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.61-71
    • /
    • 2009
  • This paper presents the results of an experiment comparing the current circular CFT columns and circular CFT columns that were additionally confined by carbon fiber sheets (CFS) under axial loading. The main experimental parameters are the numbers of CFS layers and the diameter-to-thickness ratio. 10 specimens were prepared according to the experimental parameter plans, and axial compression tests were conducted. From the tests, the failure procedure, load-axial deformation curve, maximum axial strength, and deformation capacity of the CFT columns and confined CFT columns were compared. The test results showed that the maximum axial strengths of CFT columns additionally confined by CFS are increased higher than those of the current CFT columns, and that local buckling can be delayed due to the confinement effect of CFS.

Modeling the confined compressive strength of hybrid circular concrete columns using neural networks

  • Oreta, Andres W.C.;Ongpeng, Jason M.C.
    • Computers and Concrete
    • /
    • v.8 no.5
    • /
    • pp.597-616
    • /
    • 2011
  • With respect to rehabilitation, strengthening and retrofitting of existing and deteriorated columns in buildings and bridges, CFRP sheets have been found effective in enhancing the performance of existing RC columns by wrapping and bonding CFRP sheets externally around the concrete. Concrete columns and piers that are confined by both lateral steel reinforcement and CFRP are sometimes referred to as "hybrid" concrete columns. With the availability of experimental data on concrete columns confined by steel reinforcement and/or CFRP, the study presents modeling using artificial neural networks (ANNs) to predict the compressive strength of hybrid circular RC columns. The prediction of the ultimate confined compressive strength of RC columns is very important especially when this value is used in estimating the capacity of structures. The present ANN model used as parameters for the confining materials the lateral steel ratio (${\rho}_s$) and the FRP volumetric ratio (${\rho}_{FRP}$). The model gave good predictions for three types of confined columns: (a) columns confined with steel reinforcement only, (b) CFRP confined columns, and (c) hybrid columns confined by both steel and CFRP. The model may be used for predicting the compressive strength of existing circular RC columns confined with steel only that will be strengthened or retrofitted using CFRP.

Behavior of circular CFT columns subject to axial force and bending moment

  • Kwak, Ji-Hyun;Kwak, Hyo-Gyoung;Kim, Jin-Kook
    • Steel and Composite Structures
    • /
    • v.14 no.2
    • /
    • pp.173-190
    • /
    • 2013
  • The major objective of this paper is to evaluate the behavior and ultimate resisting capacity of circular CFT columns. To consider the confinement effect, proper material models with respect to the confinement pressure are selected. A fiber section approach is adopted to simulate the nonlinear stress distribution along the section depth. Material nonlinearity due to the cracking of concrete and the yielding of the surrounding steel tube, as well as geometric nonlinearity due to the P-${\Delta}$ effect, are taken into account. The validity of the proposed numerical analysis model is established by comparing the analytical predictions with the results from previous experimental studies about pure bending and eccentric axial loading. Numerical predictions using an unconfined material model were also compared to investigate the confinement effects on various loading combinations. The ultimate resisting capacities predicted by the proposed numerical model and the design guidelines in Eurocode 4 are compared to evaluate the existing design recommendation.

FRP Confinement of Heat-Damaged Circular RC Columns

  • Al-Nimry, Hanan Suliman;Ghanem, Aseel Mohammad
    • International Journal of Concrete Structures and Materials
    • /
    • v.11 no.1
    • /
    • pp.115-133
    • /
    • 2017
  • To investigate the effectiveness of using fiber reinforced polymer (FRP) sheets in confining heat-damaged columns, 15 circular RC column specimens were tested under axial compression. The effects of heating duration, stiffness and thickness of the FRP wrapping sheets were examined. Two specimen groups, six each, were subjected to elevated temperatures of $500^{\circ}C$ for 2 and 3 h, respectively. Eight of the heat-damaged specimens were wrapped with unidirectional carbon and glass FRP sheets. Test results confirmed that elevated temperatures adversely affect the axial load resistance and stiffness of the columns while increasing their ductility and toughness. Full wrapping with FRP sheets increased the axial load capacity and toughness of the damaged columns. A single layer of the carbon sheets managed to restore the original axial resistance of the columns heated for 2 h yet, two layers were needed to restore the axial resistance of columns heated for 3 h. Glass FRP sheets were found to be less effective; using two layers of glass sheets managed to restore the axial load carrying capacity of columns heated for 2 h only. Confining the heat-damaged columns with FRP circumferential wraps failed in recovering the original axial stiffness of the columns. Test results confirmed that FRP-confining models adopted by international design guidelines should address the increased confinement efficiency in heat-damaged circular RC columns.