• Title/Summary/Keyword: Check-in

Search Result 9,519, Processing Time 0.037 seconds

Change master cast by hardening method to position of tray after impression taking (인상채득 후 경화시 트레이의 위치에 따른 주모형의 변화)

  • Lee, Jung Ae
    • Journal of Korean society of Dental Hygiene
    • /
    • v.8 no.2
    • /
    • pp.53-66
    • /
    • 2008
  • There was to purpose of this study improves analyzing cause that prosthesis brings bite engaging that is inaccurate in patient's mouth, when supposed that all conducts that do in operatory and dental laboratory are perfect. Impression did check bite by alginate impression material and polymerization style silicon impression material that use usually in presence at a sickbed Irreversibility, hydrocolloid, alginate impression material washed in flowing water and poured anhydrite after wait about 8 minutes so that region that charge interest after impression check bite may become undoing. And hydrophile property addition polymerization style impression material poured anhydrite after blow 30 considering impression material dwell time and H2 gas occurrence time (5~15 minute) after have washed in flowing water. I got each 7 models, result that manufactures total 28 and measures by third dimension measuring instrument (Meteo, Korea) following sequence curing in tray holder and floor 1, By Alginate impression when is hardened in tray holder and when is hardened in the floor after do check bite, SPH 4, SPH5 all as there is synonymy appeared(P<0.05). By in case do not use average 0.1741 in case use tray holder in 0.0447 SPH5s in case do not use average 0.2838 pastas in case use tray holder in SPH4 0.0309, When did not use both SPH4 and SPH5 tray holder, when used tray holder, 1 appeared more greatly. 2. By amity sex addition polymerization style silicon impression when is hardened in tray holder after do check bite and when is hardened in the floor SPH 4, a11 of the SPH5s very big synonymy be(P>0.05). And in case use tray holder in 0.000657 pasta SPH5s in case do not use average 0.000129 pastas in case use tray holder in SPH4 average 0.000114 pastas, by in case do not use 0.000757, I appeared more greatly when used tray when did not use both SPH4 and SPH5 tray holder, but 1 appeared is not level to keep in mind(Table 8~9). 3 SPH4 was looked very big mindfulness in model that manufacture doing impression check bite by Alginate and model that do impression check bite by amity sex accessory penalty silicon without using tray holder(P< 0.001). I use tray holder and SPH4 did not appear synonymy in model that manufacture doing impression check bite by Alginate and model that do impression check bite by amity sex accessory penalty silicon(P>0.05). Study finding of above when see synthesis Alginate certainly tray holder use must and I could know that hardening method does not exert big influence on volume stability if remove impression sieve of excess because amity sex accessory penalty silicon passes over tray, Also, Alginate impression material previewed can get heading a conspiracy style that volume stability of accessory penalty silicon impression material degree is if use tray holder.

  • PDF

Design of Quasi-Cyclic Low-Density Parity Check Codes with Large Girth

  • Jing, Long-Jiang;Lin, Jing-Li;Zhu, Wei-Le
    • ETRI Journal
    • /
    • v.29 no.3
    • /
    • pp.381-389
    • /
    • 2007
  • In this paper we propose a graph-theoretic method based on linear congruence for constructing low-density parity check (LDPC) codes. In this method, we design a connection graph with three kinds of special paths to ensure that the Tanner graph of the parity check matrix mapped from the connection graph is without short cycles. The new construction method results in a class of (3, ${\rho}$)-regular quasi-cyclic LDPC codes with a girth of 12. Based on the structure of the parity check matrix, the lower bound on the minimum distance of the codes is found. The simulation studies of several proposed LDPC codes demonstrate powerful bit-error-rate performance with iterative decoding in additive white Gaussian noise channels.

  • PDF

Flow Analysis of Cryogenic Check Valve for LNG (냉열발전을 위한 극저온 체크밸브의 유동해석)

  • Moon, Jung-Hyun
    • Journal of Power System Engineering
    • /
    • v.20 no.1
    • /
    • pp.5-10
    • /
    • 2016
  • Swing check valve is opened when the flow direction is forward, when the flow is reversed, the valve is automatically closed by back pressure. In this study, the internal flow field analysis of the valve was conducted by Fluent. The working fluid used in the study, using liquefied methane $-165^{\circ}C$ (CH4) and velocity field, pressure field, pressure drop coefficient were simulated by varying separately the opening divergence into four intervals from 0 to 100%. The approximate research result are as follow : When the opening divergence is smaller, it appears high pressure on the upstream side, this value is relaxed when the opening divergence is large. Flow rate coefficient of the valve shows a larger value as the degree of opening becomes larger, confirming that the check valve used in the study is in the effective flow rate counting range.

Effects of Design Variation of Check Valve on the Scroll Compressor Performance (체크밸브의 설계변수가 스크롤 압축기 성능에 미치는 영향)

  • Kim, Myeong Kyun;Lee, Jin Kab;Kim, Hyun Jin
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.4 s.5
    • /
    • pp.24-30
    • /
    • 1999
  • An analytical study has been carried out to investigate the effects of the check valve installation on the volumetric and adiabatic efficiencies in a scroll compressor. Both the valve displacement limit and the valve stiffness affected the valve motion, the pressure upstream of the valve, and the pattern of the mass flow through the valve to the discharge plenum. Nonetheless, the presence of the check valve did not cause any noticeable change in the volumetric efficiency. Only a slight increase in the compression work was needed to overcome the pressure increase in front of the valve. The pressure build-up upstream of the valve can be alleviated with the larger limit of the valve lift and a smaller valve stiffness.

  • PDF

Rate-Compatible LDPC Codes Based on the PEG Algorithm for Relay Communication Systems

  • Zhou, Yangzhao;Jiang, Xueqin;Lee, Moon Ho
    • Journal of Communications and Networks
    • /
    • v.17 no.4
    • /
    • pp.346-350
    • /
    • 2015
  • It is known that the progressive edge-growth (PEG) algorithm can be used to construct low-density parity-check (LDPC) codes at finite code lengths with large girths through the establishment of edges between variable and check nodes in an edge-by-edge manner. In [1], the authors derived a class of LDPC codes for relay communication systems by extending the full-diversity root-LDPC code. However, the submatrices of the parity-check matrix H corresponding to this code were constructed separately; thus, the girth of H was not optimized. To solve this problem, this paper proposes a modified PEG algorithm for use in the design of large girth and full-diversity LDPC codes. Simulation results indicated that the LDPC codes constructed using the modified PEG algorithm exhibited a more favorable frame error rate performance than did codes proposed in [1] over block-fading channels.

New Paradigm on the Safety Check of Concrete Gravity Dams at Earthquake (중력식댐의 지진시 안전검토에 대한 뉴 패러다임)

  • Bae, Jung-Joo;Kim, Yon-Gon;Lee, Jee-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.86-92
    • /
    • 2009
  • In the safety check of gravity dams at earthquake, there have been two types of analysis conducted simultaneously; one is stability analysis and the other stress analysis. But those are essentially the same calculation other than the former considers the dams rigid, while the latter considers the dams' dynamic characteristics which results in the amplification of response acceleration on the upper part of dam body. In this paper, the identity of those two methods is verified by example calculation in terms of stability check of gravity dam. It can be concluded that if stress analysis were performed, stability check of gravity dam could be accomplished with the results from stress analysis, removing unnecessary present dual calculation practice.

A Study on the Enhancement of Accuracy of Network Analysis Applications in Energy Management Systems (계통운영시스템 계통해석 프로그램 정확도 향상에 관한 연구)

  • Cho, Yoon-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.88-96
    • /
    • 2015
  • This paper describes a new method for enhancing the accuracy of network analysis applications in energy management systems. Topology processing, state estimation, power flow analysis, and contingency analysis play a key factor in the stable and reliable operation of power systems. In this respect, the aim of topology processing is to provide the electrical buses and the electrical islands with the actual state of the power system as input data. The results of topology processing is used to input of other applications. New method, which includes the topology error analysis based on inconsistency check, coherency check, bus mismatch check, and outaged device check is proposed to enhance the accuracy of network analysis. The proposed methodology is conducted by energy management systems and the Korean power systems have been utilized for the test systems.

Study on the check by static driving nail in softwood (정적(靜的) 못 박기에 의(依)한 침엽수재(針葉樹材)의 할열(割裂))

  • Shim, Sang-Ro;Kim, Su-Chang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.15-20
    • /
    • 1976
  • This is the abstract of the study on the check by static driving nail in Pinus koraiensis Sieb. et Zucc., Abies holophylla Maximowicz, and Larix leptolepis Gordon Pinet. which are commercial woods and main forestation species in Korea. The static driving resistance of nail is decresed straightly and the surface and back check's length and width were increased in proportion to increase of the moisture content, but the surface check length and width were over twice as large as the back check, also the check were happened in order of Pinus koraiensis Sieb. et Zucc., Abies holophylla Maximowicz., and Larix leptolepis Gordon Pinet. As the driving nail speed was increased, surface check length and width were increased and the back check was over twice as large as the surface check.

  • PDF

Evaluation of DQA for Tomotherapy using 3D Volumetric Phantom (3차원 체적팬텀을 이용한 토모치료의 Delivery Quality Assurance 평가)

  • Lee, Sang-Uk;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.607-614
    • /
    • 2016
  • The study investigates the necessity of 3 dimensional dose distribution evaluation instead of point dose and 2 dimensional dose distribution evaluation. Treatment plans were generated on the RANDO phantom to measure the precise dose distribution of the treatment site 0.5, 1, 1.5, 2, 2.5, 3 cm with the prescribed dose; 1,200 cGy, 5 fractions. Gamma analysis (3%/3 mm, 2%/2 mm) of dose distribution was evaluated with gafchromic EBT2 film and ArcCHECK phantom. The average error of absolute dose was measured at $0.76{\pm}0.59%$ and $1.37{\pm}0.76%$ in cheese phantom and ArcCHECK phantom respectively. The average passing ratio for 3%/3 mm were $97.72{\pm}0.02%$ and $99.26{\pm}0.01%$ in gafchromic EBT2 film and ArcCHECK phantom respectively. The average passing ratio for 2%/2 mm were $94.21{\pm}0.02%$ and $93.02{\pm}0.01%$ in gafchromic EBT2 film and ArcCHECK phantom respectively. There was a more accurate dose distribution of 3D volume phantom than cheese phantom in patients DQA using tomotherapy. Therefor it should be evaluated simultaneously 3 dimensional dose evaluation on target and peripheral area in rotational radiotherapy such as tomotherapy.

Design of Operation Management Check Items of Efficient Information System for Improvement of Business Continuity based on ISO 22301 (ISO22301 기반 비지니스 연속성 증대를 위한 효율적인 정보시스템 운영감리 점검항목 설계)

  • Joo, Nak Wan;Kim, Dong Soo;Kim, Hee Wan
    • Journal of Service Research and Studies
    • /
    • v.9 no.2
    • /
    • pp.31-40
    • /
    • 2019
  • In this paper, we have studied the improvement of operational control for the enhancement of business continuity of information system becoming more important with the development of information technology such as big data, Iot, and artificial intelligence. The operational management and audit guidance of the current information system, which is coming in the fourth industrial age, where various services, data and industries are converged, is based on the existing general information system pattern and needs to be improved. The provision of services at fixed times is linked to the survival of enterprises and countries and serves as a key element. Therefore, it is necessary to study the application of optimized check items of the operation audits to minimize the service interruption damage of the information system and to provide the stable service in terms of business continuity management. To accomplish this, the check items presented in the operational control of the information system were derived by combining the PDCA step contents and 8 resource requirements provided in ISO 22301. From the point of view of increasing the business continuity according to the derivation criteria of the inspection items, the operational inspection check items were derived by exemplifying the improved check items and review items of the information system operation audit and the products to be checked during the operational audit. The check items were divided into management audit improvement check items for service continuity management, and operational audit improvement check items for performance and availability management. The average score of the IT professionals' survey on the suitability of the proposed checklist was 4.63, which was concluded to be appropriate.