Abstract

Swing check valve is opened when the flow direction is forward, when the flow is reversed, the valve is automatically closed by back pressure. In this study, the internal flow field analysis of the valve was conducted by Fluent. The working fluid used in the study, using liquefied methane $-165^{\circ}C$ (CH4) and velocity field, pressure field, pressure drop coefficient were simulated by varying separately the opening divergence into four intervals from 0 to 100%. The approximate research result are as follow : When the opening divergence is smaller, it appears high pressure on the upstream side, this value is relaxed when the opening divergence is large. Flow rate coefficient of the valve shows a larger value as the degree of opening becomes larger, confirming that the check valve used in the study is in the effective flow rate counting range.

Keywords

References

  1. C. H. Hong, H. S. Jo, J. W. Park and J. W. Kim, 2008, "A Study on the Inner Flow Analysis for Cryogenic Globe Valve in LNG Ships", The Korean Society of Mechanical Engineers, pp. 330-336.
  2. S. W. Kim, Y. D. Choi, B. S. Kim and Y. H. Lee, 2008, "Flow Characteristics of Cryogenic Butterfly Valve for LNG Carrier (Part 2 : Flow Characteristics under Cryogenic Condition)", KOREAN SOCIETY FOR FLUID MACHINERY, Vol. 11, No. 2, pp. 20-28. https://doi.org/10.5293/KFMA.2008.11.2.020
  3. J. U. Cho and M. S. Han, 2011, "A Study on Flow Analysis at Ball Valve according to Opening and Shutting Angle", The Korean Society of Manufacturing Process Engineers, Vol. 10, No. 2, pp. 46-51.
  4. S. Y. Jeon, C. K. Kim, K. T. Oh and J. Y. Yoon, 2011, "Performance Evaluation of Top Entry Ball Valves using Numerical Analysis", KOREAN SOCIETY FOR FLUID MACHINERY, pp.1-2.

Cited by

  1. Performance Evaluation of Ice Production Utilizing the Thermoelectric Module for the Residential Refrigerators vol.23, pp.4, 2016, https://doi.org/10.9726/kspse.2019.23.4.005