• Title/Summary/Keyword: Chamber Test

Search Result 1,528, Processing Time 0.026 seconds

Combustion Performance of a Fullscale Liquid Rocket Thrust Chamber (실물형 액체로켓 연소기 지상 연소 성능 결과)

  • Seo Seong-Hyeon;Kim Jong-Gyu;Moon Il-Yoon;Han Yeoung-Min;Choi Hwan-Seok;Lee Soo-Yong;Cho Kwang-Rae
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.235-239
    • /
    • 2005
  • A 30-tonf-class fullscale thrust chamber for the application to a LEO SLV has been combustion tested over the wide ranges of a mixture ratio and a chamber pressure. The thrust chamber designed for an open cycle engine with a turbopump was tested with a ablative combustion chamber instead of a regenerative chamber to first evaluate its performance and function. The test results revealed stable combustion characteristics. The hardware survived the harsh environment and showed very sound functional characteristics. The estimated combustion efficiency of the chamber turned out to be 95% and a specific impulse at sea level was estimated as 254sec, which are comparable to or above the predicted design values.

  • PDF

Test & Evaluation for the Configuration Optimization of Thrust Chamber in 70 N-class N2H4 Thruster (Part I: Pulse-mode Performance According to the Chamber Diameter Variation) (70 N급 하이드라진 추력기의 추력실 최적설계와 시험평가 (Part I: 추력실 직경변화에 따른 펄스모드 성능특성))

  • Kim, Jong Hyun;Jung, Hun;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.1
    • /
    • pp.42-49
    • /
    • 2014
  • Performance evaluation was carried out for the 70 N-class hydrazine thruster whose design performance had been already verified. The pulse-mode firing test was conducted for the development model thrusters with various thrust chamber diameters. Evaluation was made by the performance parameters such as specific impulse, impulse bit, and characteristic velocity, etc: specific impulse and characteristic velocity were deteriorated as the thrust chamber diameter deviates from a standard model. Consequently, it is revealed that the performance characteristics of standard model is most superior among the test models.

Low Pressure Firing Tests of 75-tonf-Class Channel Cooling Thrust Chamber (75톤급 채널냉각 연소기 저압연소시험)

  • Lim, Byoung-Jik;Han, Yeoung-Min;Kim, Jong-Gyu;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.1
    • /
    • pp.69-75
    • /
    • 2011
  • Firing tests have been carried out for a technology demonstration model of 75-tonf-class combustor which is to be used on the liquid rocket engine of a Korean space launch vehicle. Firing tests were done at 50% of the nominal flow rate because of incapability of the test facility and limit of the test bed strength. Through the low pressure firing tests of 75-tonf-class channel cooling thrust chamber, operability and stability at the ignition and combustion phases were confirmed. Additionally it was foreseen that the 75-tonf-class thrust chamber would satisfy the performance requirements.

Evaluation of KICT-type Large Penetration Test using Calibration Chamber System (Calibration Chamber System을 이용한 KICT-type LPT 장비의 거동분석)

  • Kim, Young-Seok;Kim, Young-Chin;Lee, Woo-Jin;An, Shin-Whan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1359-1364
    • /
    • 2008
  • It is well known that the standard penetration test (SPT) has been used in all over the world to get geotechnical properties of the ground. However, it is difficult to apply the SPT to the dense sand, gravel, weathered rock, etc. For the application of the SPT in these grounds, it is necessary to change in the diameter and the impact energy of the SPT. For the improvement of site investigation technology, Large Penetration Testing device (KICT-type LPT) was developed and applied to the in situ condition. The drop height and weight of the hammer in developed system were decided as 760mm and 150kg, respectively. And the developed sampler has the inner diameter of 63 mm and the length of 500 mm with the adjustment of energy ratio to the SPT of 1.5. In this study, the performance of KICT-type LPT was evaluated by using a calibration chamber system and pile driving analyzer (PDA)

  • PDF

Low Pressure Firing Tests of 75-tonf-Class Channel Cooling Thrust Chamber (75톤급 채널냉각 연소기 저압연소시험)

  • Lim, Byoung-Jik;Han, Yeoung-Min;Kim, Jong-Gyu;Seo, Seong-Hyeon;Ahn, Kyu-Bok;Kim, Mun-Ki;Lee, Kwang-Jin;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.71-74
    • /
    • 2010
  • Using the technology demonstration model of 75-tonf-class combustor which is expected to be used to the rocket engine of a korean space launch vehicle, 2 times of firing tests were carried out. Firing tests were done at 50% of the nominal flow rate because of incapability of the test facility and limit of the test bed strength. Through the low pressure firing tests of 75-tonf-class channel cooling thrust chamber, reliability and stability at the ignition and combustion phases were confirmed. Additionally it was foreseen that the 75-tonf-class thrust chamber would satisfy the performance requirements.

  • PDF

An Experimental Study on the VOCs Concentration Variation using a Petroleum Spill Imitation Trial Test Chamber (원유유출 모의시험 챔버를 이용한 휘발성유기화합물(VOCs)의 농도변화에 관한 연구)

  • Chung, Jin-Do;Lee, Dong-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.4
    • /
    • pp.393-398
    • /
    • 2010
  • This study prepared and utilized an imitation trial test chamber for a petroleum spill to predict the concentration of discharged Volatile Organic Compounds in the air at the time of Tae-An peninsula's petroleum spill, which happened in December, 2007. The petroleum spill imitation trial test chamber measured and analyzed the concentration variation of total VOCs. As the ambient air velocity increased, so the concentration of VOCs decreased; and as the water temperature rose, the concentration of VOCs increased. Furthermore, it appears that total concentration of VOCs decrease by more than 90% 6 days after the initial petroleum spill compared to the initial concentration of VOCs.

Evaluation of Formability of Copper Alloy for Regenerative Cooling Chamber before and after Heat Treatment (재생냉각 챔버 제작용 구리합금의 열처리 전후 성형성 평가)

  • Ryu, Chul-Sung;Lee, Keum-Oh;Choi, Hwan-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.12
    • /
    • pp.1201-1208
    • /
    • 2009
  • Dome stretching tests and tension tests were performed to evaluate the formability of a copper alloy used for manufacturing the regenerative cooling chamber. The test specimens were prepared to investigate the effect of heat treatment and direction of specimens on the formability. The test results show that forming limit values are increased by the heat treatment of the material but the variation of the forming limit values by manufacturing direction is negligible compared to the heat treatment effect, and forming limit values are also different according to the test methods. These results indicate that the high temperature heat treatment of the material before bulging is a very important process to deform the inner cylindrical structure of the regenerative cooling chamber into a nozzle shape by the bulging process without necking or fracture and the test methods also have a great effect on a evaluation of the formability. The forming limit diagram obtained in this study would be utilized to the design of regenerative cooling chamber nozzles.

Development of 2-ton thrust-level sub-scale calorimeter (추력 2톤급 축소형 칼로리미터 개발)

  • Cho, Won-Kook;Ryu, Chul-Sung;Chung, Yong-Hyun;Lee, Kwang-Jin;Kim, Seung-Han;Lee, Soo-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.107-113
    • /
    • 2005
  • A calorimeter of 2-ton thrust level rocket engine chamber has been developed to measure the wall heat flux. The liner of the chamber is made of copper-chromium alloy to maximize the heat transfer performance and structural strength. 1-D design code based on empirical correlations has been used for the prediction of the global thermal characteristics while 3-D CFD has been applied for the verification of local cooling performance. The predicted average wall heat flux at the throat is 43 $MW/m^{2}$ for the combustion chamber pressure of 53 bar. The chamber structure is confirmed to be safe at the pressure of 150 bar through 2-D stress analysis and measurement of the strain of the test species. Finally, the test of pressurizing the calorimeter chamber has been performed with water at the pressure of 150 bar in room temperature environment. No thermal damage has been detected after the hot-fire test in the test nozzle of same cooling performance with the developed calorimeter though the measured throat heat flux is higher than the design value by 10%.

Development and Acceptance Test Results of 75-tonf Class Liquid Rocket Engine Gas Generator (75톤급 가스발생기 개발시험 및 수락시험 결과)

  • Lim, Byoungjik;Kim, Munki;Kang, Donghyuk;Kim, Hyeon-Jun;Kim, Jong-Gyu;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.4
    • /
    • pp.55-65
    • /
    • 2020
  • In this paper, development and acceptance test results of 75-tonf class liquid rocket engine gas generators are described. Up to now, more than 330 times and cumulative time of 7,000 seconds gas generator autonomous tests have been carried out with 44 gas generator models. Through the tests it was verified that 75 tonf gas generator shows very reliable and reproducible characteristics in terms of chamber pressure, combustion efficiency, pressure loss, combustion stability, burnt gas temperature, and etc. 5 gas generators which are the last series of 75 tonf gas generator for the Korea Space Launch Vehicle II, will be manufactured until end of 2019 and their acceptance tests will be executed at the first half of 2020.

Analysis of Pintle Tip Thermal Damage in the Combustion Hot Firing Test with a 1.5-tonf Class Liquid-Liquid Pintle Injector (1.5톤급 액체-액체 핀틀 분사기 연소시험에서의 핀틀 팁 열손상 원인 분석)

  • Kang, Donghyuk;Hwang, Dokeun;Ryu, Chulsung;Ko, Youngsung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.6
    • /
    • pp.1-9
    • /
    • 2020
  • Using kerosene and liquid oxygen, 1.5-tonf class liquid-liquid pintle injector with rectangular two-row orifice was designed and manufactured. The combustion test of the pintle injector was carried out to verify the combustion performance and combustion stability under a supercritical condition which is the actual operation condition of the liquid rocket engine. The combustion test result showed that the pintle tip was damaged by the high temperature combustion gas in the high-mixed ratio recirculation zone of the combustion chamber. To solve this problem, the insert nozzle was installed in the pintle injector to increase cooling performance at the pintle tip. As a result of the hot firing test, installation of the insert nozzle, AR and BF had a great effect on pintle tip cooling performance.