Firing tests have been carried out for a technology demonstration model of 75-tonf-class combustor which is to be used on the liquid rocket engine of a Korean space launch vehicle. Firing tests were done at 50% of the nominal flow rate because of incapability of the test facility and limit of the test bed strength. Through the low pressure firing tests of 75-tonf-class channel cooling thrust chamber, operability and stability at the ignition and combustion phases were confirmed. Additionally it was foreseen that the 75-tonf-class thrust chamber would satisfy the performance requirements.

한국형발사체 엔진에 사용될 예정인 75톤급 연소기 채널냉각형 기술검증시제에 대한 연소시험을 수행하였다. 설비 공급 능력과 구조물 강도 제한으로 정상 유량의 50% 수준에서 시험이 수행되었다. 75톤급 채널냉각 연소기의 저압연소시험을 통해 점화구간과 연소구간에서의 작동성과 안정성이 확인되었다. 더불어 75톤 연소기의 성능요구조건을 만족시킬 수 있을 것으로 추정할 수 있었다.

Keywords

References

  1. 한영민, 김종규, 이광진, 서성현, 김성구, 유철성, 최환석, "75톤급 액체로켓엔진 연소기 기본설계," 한국추진공학회 추계학술대회, 2009, pp.125-129
  2. 이광진, 김종규, 임병직, 서성현, 한영민, 유철성, 최환석, "75톤급 액체로켓엔진 연소기의 기술검증 시제 제작," 한국추진공학회 추계학술대회, 2009, pp.608-612
  3. 한영민, 김종규, 이광진, 임병직, 안규복, 서성현, 최환석, "30톤급 액체로켓엔진 재생냉각 연소기 저압 연소시험 결과," 한국추진공학회 춘계학술대회, 2009, pp.71-74
  4. 김문기, 한영민, 김종규, 안규복, 이광진, 최환석, "75톤급 연소기의 기술검증 시제 수류시험 및 점화시험," 한국추진공학회 추계학술대회, 2009, pp.97-100
  5. 김종규, 안규복, 임병직, 김문기, 한영민, 최환석, "75톤급 액체로켓엔진 연소기 저압연소시험," 한국추진공학회 춘계학술대회, 2010, pp.10-13
  6. 강동혁, 임병직, 안규복, 서성현, 한영민, 최환석, "75톤급 액체로켓엔진 채널냉각 연소실 수류시험 및 점화시험," 한국추진공학회 춘계학술대회, 2010, pp.25-28
  7. 임병직, 한영민, 김종규, 서성현, 안규복, 김문기, 이광진, 최환석, "75톤급 채널냉각 연소기 저압연소시험," 한국추진공학회 춘계학술대회, 2010, pp.71-74
  8. 임병직, 서성현, 김문기, 강동혁, 한영민, 최환석, "75톤급 액체로켓엔진 연소기 시험설비 기본설계," 한국추진공학회지 제14권, 제5호, 2010, pp.84-91