• Title/Summary/Keyword: Center Loss

Search Result 3,753, Processing Time 0.038 seconds

A Study on Polarization of the Molten Carvonate Fuel Cell (용융탄산염 연료전지의 분극현상 연구)

  • Nam, S.W.;Suh, S.H.;Lim, T.H.;Oh, LH.;Hong, S.A.;Lim, H.C.
    • Journal of Hydrogen and New Energy
    • /
    • v.3 no.2
    • /
    • pp.55-62
    • /
    • 1992
  • To improve the MCFC performance it is important to distingush between polarization losses occuring in the individual electrodes and other components. In this study a current interruption technique has been applied to a MCFC unit cell having a reference electrode to separately study the contributions of IR loss and other polarization losses. At a current density of $150mA/cm^2$ the IR-free polarization of a Ni anode was about 60mV while that of a NiO cathode was 130mV and the Ohmic loss of the cell was as large as 170mV suggesting that both the cathode and the cell structure need further improvement. The thin-film electrode model was used to simulate the performance of the electrodes. Both andoe data and cathode data were successfully fitted.

  • PDF

The Bandpass Filter with Transmission Zero Using . the Effect of Effective Inductance and Multi-layer PCB (유효 인덕턴스 효과와 적층 PCB를 이용한 하나의 전송 영점을 갖는 대역 통과 필터)

  • Kim, Yu-Seon;Nam, Hun;Lee, Geon-Cheon;Seo, In-Jong;Lim, Yeong-Seog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.11 s.114
    • /
    • pp.1089-1095
    • /
    • 2006
  • In this paper, the circuit analysis of three-dimensional bandpass filter with transmission zero in multi-layer printed circuit board is presented. The equivalent circuit of bandpass filter is evaluated by microwave network analysis. Compare to the established paper that have configured the circuit model of filter except the effect of distribute element, the proposed model can include the effect. As a result, the multi-layer PCB bandpass filter with transmission zero has designed by extracting mutual capacitance from electrical component inside inductor. The structure size is only $10mm{\times}20mm{\times}1.251mm$. Measured data of the bandpass filter indicate 1.9 dB of insertion loss and 28 dB of return loss at the center frequency of 1.84 GHz, as well as 43 dB attenuation at the refraction frequency of 2.78 GHz.

Metabolic Topography of Parkinsonism

  • Kim, Jae-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.2
    • /
    • pp.141-151
    • /
    • 2007
  • Parkinson's disease is one of the most frequent neurodegenerative diseases, which mainly affects the elderly. Parkinson's disease is often difficult to differentiate from atypical parkinson diorder such as progressive supranuclear palsy, multiple system atrophy, dementia with Lewy body, and corticobasal ganglionic degeneration, based on the clinical findings because of the similarity of phenotypes and lack of diagnostic markers. The accurate diagnosis of Parkinson's disease and atypical Parkinson disorders is not only important for deciding on treatment regimens and providing prognosis, but also it is critical for studies designed to investigate etiology and pathogenesis of parkinsonism and to develop new therapeutic strategies. Although degeneration of the nigrostriatal dopamine system results in marked loss of striatal dopamine content in most of the diseases causing parkinsonism, pathologic studies revealed different topographies of the neuronal cell loss in Parkisonism. Since the regional cerebral glucose metabolism is a marker of integrated local synaptic activity and as such is sensitive to both direct neuronal/synaptic damage and secondary functional disruption at synapses distant from the primary site of pathology, an assessment of the regional cerebral glucose metabolism with F-18 FDG PET is useful in the differential diagnosis of parkinsonism and evaluating the pathophysiology of parkisonism.

Nutritional Risk in Oncology Outpatients Receiving Chemotherapy (외래에서 항암화학요법을 받는 암환자들의 영양불량 위험도 연구)

  • Kim, Won-Gyoung;Park, Mi-Sun;Lee, Young-Hee;Heo, Dae-Seog
    • Korean Journal of Community Nutrition
    • /
    • v.13 no.4
    • /
    • pp.573-581
    • /
    • 2008
  • Although it is well known that cancer patients suffer from malnutrition, there are few published studies on malnutrition in outpatients receiving chemotherapy in Korea. This study aimed to evaluate nutritional risk in oncology outpatients receiving chemotherapy and to show the baseline data to set up nutritional management programs for cancer patients. This is a retrospective observational analysis on 1,962 patients referred for nutritional education before or during chemotherapy at Seoul National University Hospital Cancer Center from January 2006 to May 2007. According to a malnutrition screening tool, the proportion of patients having malnutrition risk was 23.0%. In the case of upper gastrointestinal cancer, more than 50% of patients were assessed as being at the risk of malnutrition. They showed more than 7% weight loss compared to their usual body weight and poor oral intake; energy intake was less than 100% of Basal Energy Expenditure(BEE) and protein intake was less than or equal to 0.77 g/kg/d. However, only 6.3% of breast cancer patients had risk of malnutrition and their oral intake was better; energy intake was 121% of BEE, and protein intake was 0.90 g/kg/d. Outpatients receiving chemotherapy had different nutritional risk depending on their cancer site. Nutritional management program should be conducted differently, depending on the cancer site and upper gastrointestinal cancer patients at high risk of malnutrition should basically have nutritional assessment and intervention.

Assessment of Earthquake Disaster Risk in Seoul Metropolitan Area (서울지역 지진 재해 위험도 평가)

  • Lee, Chang-Soo
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.4 s.19
    • /
    • pp.71-78
    • /
    • 2005
  • The principal basic concepts of aseismic design minimize damage of human-life and have little probability during life of structures. For detailed understanding of the design, the best reasonable countermeasure can be possible equally the smallest damage of human-life and economic loss. As a result, it can be achieved by notion of not structure-centered but city-centered, the notion is actualized by development of a macro-level evaluation. A seismic damage between city and country is different. And the larger the city then, the greater the loss by rather collateral hazards than collapse of structures. Hence, the macro-evaluation of an earthquake disaster is suitable for an old city where is center of political and economic activity, and is concentration of population and infrastructure. This study aims to develop comprehensive earthquake desaster risk index, and assesses relative earthquake risk of six zones in Seoul metropolitan area.

The Pattern Improvement of Leaky-wave Slot Array Antenna for Satellite Communications (위성통신용 슬롯배열 누설파 안테나의 패턴 개선)

  • Lim, Gye-Jae;Park, Jong-Seo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.2
    • /
    • pp.69-77
    • /
    • 2009
  • Small size and low profile antenna for mobile vehicular-top-mounted is needed in satellite communication services such as DBS, Satellite Internet and VSAT. In middle latitudes, the development of an array antenna which has the conformal, low profile and 45 degree beam tilted configuration, and has the high gain with sharp beamwidth, low sidelobe and low loss is required for Ka band satellite communication. In this paper, in order to meet with these performances, an array antenna consisting of the vertical polarized waveguide longitudinal slots based on the leaky-wave mode of traveling wave antenna is proposed. Especially, for the lower sidelobe level the radiation power control using a design method of the different slot width is proposed. An array antenna consisting of 32 leakywave elements is showing 34.4 dBi of gain, 3.6 degree of beamwidth, below than -25 dB of sidelobe level, 43 degree of beam tilt angle in center frequency 20.0 GHz. Feed network designed by waveguide cooperated feed shows good performance of wideband and low loss.

  • PDF

Combustion Characteristics Analysis of a Non-class 1E Cable for Nuclear Power Plants according to Aging Period (경년열화 기간에 따른 원자력발전소용 비안전등급 케이블의 연소특성 분석)

  • Kim, Min Ho;Lee, Seok Hui;Lee, Min Chul;Lee, Sang Kyu;Lee, Ju Eun
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.5
    • /
    • pp.22-29
    • /
    • 2020
  • In this study, combustion and smoke release characteristics of a non-class 1E cable for nuclear power plants were investigated according to aging period. The aging was reproduced through an accelerated aging method for interval of 10 years :10, 20, 30 and 40 year, which was applied the Arrhenius equation. The cable was subjected to accelerated aging. In order to understand combustion and smoke release characteristics, the cone calorimeter test was performed according to the standard code of KS F ISO 5660-1. Heat release rate, mass loss rate, average rate of heat emission and smoke production rate were examined through cone calorimeter test. Fire performance index, fire growth index and smoke factor were derived from test results for the comparison of quantitative fire risk. When comparing the fire performance index and the fire growth index, the early fire risk tends to decrease as aging progresses, which might be attributed from the fact that the volatile substances of cables were evaporated. However, when comparing the heat release rate, average rate of heat emission and mass loss rate, which represent the mid and late periods of the fire risk, the values of accelerated aging cables were much higher than those of non-aged cable, which signifies the unstable formation of the char layer resulted in the change in the performance of flame retardants. In addition, the results from the smoke characteristics show that the accelerated aging cables were lager than the non-aged cables in terms of overall fire risk. These results can be used as baseline data when assessing fire risk of cables and establishing fire safety code for nuclear power plants.

The design and Fabrication of Bandpass Filter Using Step Impedance Resonators of Coaxial Type (동축 형태의 스텝 임피던스 공진기를 이용한 필터 설계 및 제작)

  • Lee, Jung-Nam
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.7
    • /
    • pp.1272-1278
    • /
    • 2009
  • The present paper is purposeful that I compare the materialization method of the filter of UIR and SIR, then make two filters of different methods, so both are useful. The structure of the method of UIR is simple, so it is used a commercial point of view that the client gets the characteristics what he wants. However, the needs of companies when compared to the same standards, a little more cheaply in price, a little smaller in size, better performance characteristics are expected. In this regard, the method of SIR is smaller than UIR in size, but it shows the similar characteristics of UIR, so it is expected that holds a dominant position in competitive power. In this paper, based on these conditions, I compared the methods of SIR and UIR after the design and production. The standards are Insertion Loss is less than 0.8dB, Return Loss is above 20.0dB, and the Ripple is within 0.3dB. The center frequency is settled 881.5MHzband that TX Band is used by CDMA(SKT). I compared in the same conditions in Bandwidth 25.0MHz.

Behaviour of the Fretting Wear and Corrosion Characteristics on a Hinge Material (힌지재료의 부식특성 및 찰과마멸 거동)

  • Kwak Nam-In;Lim Uh-Joh;Lee Jong-Rark
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.3 s.8
    • /
    • pp.39-44
    • /
    • 1999
  • In the study, corrosion characteristics under various corrosion environments(neutral solution, acid solution), for various hinge materials(SM20C, BsC3 and STC4H), were investigated by immersion test, and the behaviour of fretting wear under atmosphere was studied. In immersion test, corrosion potential of those materials showed to be noble in the sequence of $0.5\%HNO_3$> underground water> $0.5\%\;H_2SO_4$ solution, and potential of a sole material, except BsC3, was more noble than these of mixed materials. In same material SM20C, the fretting wear loss of rotary materials increased about 1.9 times to that of moving materials, because of surface hardening by frictional force.

  • PDF

Risk Model Development for PWR During Shutdown (원자로 정지 동안의 위해도 모델 개발)

  • Yoon, Won-Hyo;Chang, Soon-Heung
    • Nuclear Engineering and Technology
    • /
    • v.21 no.1
    • /
    • pp.1-11
    • /
    • 1989
  • Numerous losses of decay heat removal capability have occurred at U during stutodwn while its significance to safety is needless to say. A study is carried out as an attempt to assess what could be done to lower the frequency of these events and to mitigate their consequences in the unlikely event that one occurs. The shutdown risk model is developed and analyzed using Event/Fault Tree for the typical pressurized water reactor. The human cognitive reliability (HCR) model, two-stage bayesian approach and staircase function model are used to estimate human reliability, initiating event frequency and offsite power non-recovery probability given loss of offsite power, respectively. The results of this study indicate that the risk of a Pm at shutdown is not much lower than the risk when the plant is operating. By examining the dominant accident sequences obtained, several design deficiencies are identified and it is found that some proposed changes lead to significant reduction in core damage frequency due to loss of cooling events.

  • PDF