• 제목/요약/키워드: Cell Tracking

검색결과 272건 처리시간 0.023초

Near-infrared (NIR) 영상기법을 이용한 생체 내 수지상세포의 이동 (In vivo Dendritic Cell Migration Tracking Using Near-infrared (NIR) Imaging)

  • 이준호;정남철;이은계;임대석
    • KSBB Journal
    • /
    • 제27권5호
    • /
    • pp.295-300
    • /
    • 2012
  • Matured dendritic cells (DCs) begin migration with their release from the bone marrow (BM) into the blood and subsequent traffic into peripheral lymphoid and non-lymphoid tissues. Throughout this long movement, migrating DCs must apply specialized skills to reach their target destination. Non-invasive in vivo cell-tracking techniques are necessary to advance immune cell-based therapies. In this study, we used a DiD cell-tracking solution for in vivo dendritic cell tracking in naive mice. We tracked DiD (non-invasive fluorescence dye)-labeled mature dendritic cells using the Near Infrared (NIR) imaging system in normal mice. We examined the immunophenotype of DiD-labeled cells compared with non-labelled mature DCs, and obtained time-serial images of NIR-DC trafficking after mouse footpad injection. In conclusion, we confirmed that DiD-labeled DCs migrated into the popliteal lymph node 24 h after the footpad injection. Here, these data suggested that the cell tracking system with the stable fluorescence dye DiD was useful as a cell tracking tool to advance dendritic cell-based immunotherapy.

세포동영상의 자동분석을 위한 효율적인 세포추적방법 (Efficient Cell Tracking Method for Automatic Analysis of Cellular Sequences)

  • 한찬희;송인환;이시웅
    • 한국콘텐츠학회논문지
    • /
    • 제11권5호
    • /
    • pp.32-40
    • /
    • 2011
  • 저속촬영이 가능한 현미경을 통해 얻어진 세포동영상에서 세포활동의 추적 및 분석은 종양의 전이, 바이러스의 침입, 상처회복, 세포분열과 같은 복잡한 생물학적 과정을 이해하는데 있어 매우 중요한 역할을 담당한다. 세포추적의 자동화를 위해서는 각 프레임에서의 세포검출, 전후 프레임 내 세포들의 상관관계 조사, 새로운 세포의 인식 및 세포분열의 확인 등과 같은 일련의 작업들이 수행되어야 한다. 본 논문에서는 이를 위한 효과적인 자동 세포 추적 알고리즘을 제시한다. 첫 번째 프레임에서는 세포영역의 특성 분석을 통해 얻어진 특징벡터를 이용하여 각 세포의 마커 영역을 추출하고, 여기에 워터쉐드 알고리즘을 적용함으로써 세포 분할을 수행한다. 연속된 프레임들에서는 이전 프레임의 분할결과를 이용하여 현재 프레임에서의 분할 과정이 수행된다. 그리고 각 세포의 기하학적 특성과 밝기 특성의 결합 비용함수를 사용하여 전후 프레임 간 세포의 올바른 상관관계를 조사함으로써 세포 추적의 정확도를 개선한다. 실험에서 세포영상 분석을 위한 소프트웨어 패키지인 CellProfiler와의 비교/분석을 통해 제안 알고리즘의 효율성을 입증하였다.

The Present Status of Cell Tracking Methods in Animal Models Using Magnetic Resonance Imaging Technology

  • Kim, Daehong;Hong, Kwan Soo;Song, Jihwan
    • Molecules and Cells
    • /
    • 제23권2호
    • /
    • pp.132-137
    • /
    • 2007
  • With the advance of stem cell transplantation research, in vivo cell tracking techniques have become increasingly important in recent years. Magnetic resonance imaging (MRI) may provide a unique tool for non-invasive tracking of transplanted cells. Since the initial findings on the stem cell migration by MRI several years ago, there have been numerous studies using various animal models, notably in heart or brain disease models. In order to develop more reliable and clinically applicable methodologies, multiple aspects should be taken into consideration. In this review, we will summarize the current status and future perspectives of in vivo cell tracking technologies using MRI. In particular, use of different MR contrast agents and their detection methods using MRI will be described in much detail. In addition, various cell labeling methods to increase the sensitivity of signals will be extensively discussed. We will also review several key experiments, in which MRI techniques were utilized to detect the presence and/or migration of transplanted stem cells in various animal models. Finally, we will discuss the current problems and future directions of cell tracking methods using MRI.

SPA에 의한 동적인 보트의 태양전지 효율 분석 (Efficiency Analysis Solar Cell of the Dynamic Boat's by SPA)

  • 한종호;이장명
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1529-1536
    • /
    • 2011
  • Recently, worldwide government policy is pursuing saving energy and preservation. add to this, the solar cells are getting the spotlight nonpolluting energy source, using a variety of products for solar cell. in this paper, we'll make solar tracking system for suitable of dynamic boat. we knew that general boats are using fixed solar cell, it's first time to use tracking system of solar cells for boats so it is hard to application. To solve this problem in this paper we use to a magnetic compass and GPS for suitable solar tracking system of dynamic movement and to analyze fixed and tracking solar system. frist. solar tracking device is designed two-axis control system. one-axis control system is taken a magnetic compass for making efficiency defence solar tracking sensor, two-axis control system apply GPS latitude and longitude data for SPA(Solar position algorithm) so we know the azimuth and altitude. it analyze data value of accuracy comparison from result. so the proposed algorithm confirm to have validity.

유전율 이방성이 음인 액정을 이용한 Fringe-field Switching Mode의 Authentic-color 특성 (Authentic-color Characteristic of the Fringe-field Switching Mode using a Liquid Crystal with Negative Dielectric Anisotropy)

  • 송제훈;최윤석;문대규;한정인;이승희
    • 한국전기전자재료학회논문지
    • /
    • 제17권6호
    • /
    • pp.633-640
    • /
    • 2004
  • We have studied color tracking of a fringe-field driven homogenously aligned nematic liquid crystal (LC) cell with negative dielectric anisotropy and compared it with other devices such as the twisted nematic(TN) and in-plane switching(IPS) modes. According to studies, the TN device shows bluish color at grey scale and even at a low retardation cell it cannot avoid color tracking. The authentic IPS device having cell retardation value of 0.23 ${\mu}{\textrm}{m}$ also shows bluish white color. However, the FFS device shows excellent color tracking characteristics even at high retardation value of the cell while keeping high transmittance and greenish white.

심혈관계 질환의 줄기세포 치료에서 세포 추적 영상 (Tracking of Stem Cells for Treatment in Cardiovascular Disease)

  • 강원준
    • 대한핵의학회지
    • /
    • 제39권2호
    • /
    • pp.146-149
    • /
    • 2005
  • Various stem cells or progenitor cells are being used to treat cardiovascular disease in ischemic heart disease, stem ceil therapy is expected to regenerate damaged myocardium. To evaluate effects of stem cell treatment, the method to image stem cell location, distribution and differentiation is necessary. Optical imaging, MRI, nuclear imaging methods have been used for tracking stem cells. The methods and proglems of each imaging technique are reviewed.

ZVCS 컨버터를 이용한 태양전지 최대전력 검출법 (Maximum power tracking Strategy of a Solar Cell using ZVCS converter)

  • 곽동걸;전현규;김종민;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1032-1034
    • /
    • 2001
  • As well known, a solar cell has an optimal operating point to be able to get the maximum power $P_{max}$. So, many $P_{max}$ tracking controllers using the line voltage of a solar cell have been popularly used. But it may vary depending on the miss match between the solar cell output and the load. In this paper, we investigate the possibilities of $P_{max}$ control using the current tracking controller and the output voltage and the output current instead of the solar cell output power. And we also examine about the optimal power converter using ZVCS step up and down chopper circuit to operate the solar cell at an optimal voltage using these variables. And then, we show some experimental results to confirm the successful operation.

  • PDF

A Simple Volume Tracking Method For Compressible Two-Phase Flow

  • SHYUE KEH-MING
    • 천문학회지
    • /
    • 제34권4호
    • /
    • pp.237-241
    • /
    • 2001
  • Our goal is to present a simple volume-of-fluid type interface-tracking algorithm to compressible two-phase flow in two space dimensions. The algorithm uses a uniform underlying Cartesian grid with some cells cut by the tracked interfaces into two subcells. A volume-moving procedure that consists of two basic steps: (1) the update of volume fractions in each grid cell at the end of the time step, and (2) the reconstruction of interfaces from discrete set of volume fractions, is employed to follow the dynamical behavior of the interface motion. As in the previous work with a surface-tracking procedure for general front tracking (LeVeque & Shyue 1995, 1996), a high resolution finite volume method is then applied on the resulting slightly nonuniform grid to update all the cell values, while the stability of the method is maintained by using a large time step wave propagation approach even in the presence of small cells and the use of a time step with respect to the uniform grid cells. A sample preliminary numerical result for an underwater explosion problem is shown to demonstrate the feasibility of the algorithm for practical problems.

  • PDF

자동 세포 추적을 위한 클러스터 세포 분리 알고리즘 (Cluster Cell Separation Algorithm for Automated Cell Tracking)

  • 조미경;심재술
    • 대한기계학회논문집B
    • /
    • 제37권3호
    • /
    • pp.259-266
    • /
    • 2013
  • 광학 현미경을 통해 일정한 시간 간격으로 얻은 세포 이미지로부터 세포 변화를 자동적으로 추적 및 분석하는 것이 세포 트래킹이라고 한다. 세포 변화 과정에서 이웃에 있는 세포들이 겹쳐져 있는 상태를 클러스터라고 하며 세포트래킹에서 클러스터를 다시 세포로 분리하는 작업은 매우 중요하다. 본 논문에서는 타원 근사법을 기반으로 클러스터를 분리하기 위한 알고리즘을 제안한다. 클러스터의 외곽선을 추출한 후 외곽선의 오목정점을 이용하여 클러스터를 라인 세그먼트들로 분리한 다음 휴리스틱을 이용하여 라인 세그먼트들을 결합해 가며 근사 타원을 생성한다. 실험 결과 두 개의 세포가 겹쳐진 클러스터의 경우 평균적으로 91%, 세 개의 세포가 겹쳐진 경우 평균적으로 84% 그리고 겹쳐진 세포의 개수가 네 개 이상인 경우 약 73%의 정확도로 클러스터를 분리해 주었다.

3.0 T MRI 환경에서 마이크로비드를 이용한 서브복셀 추적에 관한 수치해석적 연구 (Numerical Study on the Sub-Voxel Tracking Using Micro-Beads in a 3.0 T MRI)

  • 한병희;이수열
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.102-107
    • /
    • 2007
  • In molecular imaging studies via magnetic resonance imaging, in vivo cell tracking is an important issue for the observation of cell therapy or disease behavior. High resolution imaging and longitudinal study are necessary to track the cell movement. Since the field inhomogeneity extends over several voxels, we have performed the numerical analysis using the sub-voxel method dividing a voxel of MR image into several elements and the information about the field inhomogeneity distribution around the micro-beads. We imbedded ferrite-composite micro-beads with the size of $20-150{\mu}m$ in the subject substituted for cells to induce local field distortion. In the phantom imaging with the isotropic voxel size of $200{\mu}m^3$, we could confirm the feasibility of sub-voxel tracking in a 3.0 T MRI.