• Title/Summary/Keyword: Catheter Tubes

Search Result 14, Processing Time 0.017 seconds

Flow Analysis of Resin in an Extrusion Die for the Production of Medical Catheter Tubes (의료용 카테타 튜빙의 압출을 위한 다이내의 수지 흐름해석)

  • Lee, M.A.;Lyu, M.-Y.;Shin, D.J.;Kim, T.K.
    • Transactions of Materials Processing
    • /
    • v.24 no.2
    • /
    • pp.89-94
    • /
    • 2015
  • Medical catheter tubes are disposable devices that are inserted into the body cavities such as the pleura, trachea, esophagus, stomach, urinary bladder, ureter, or blood vessels for surgical procedures. Each hole of the inner tube is called a lumen, which is used as a passage for drug injections, waste discharge, polypus removal, blood transport, or injection of a camera or sensor. The catheter tube is manufactured by extrusion. The flow in the inner extrusion die affects the thickness and diameter of the tube. In the current study computer simulation of flow in an extrusion die for catheter tubing was performed. Velocity, pressure, shear rate, and shear stress were investigated and the die design was examined.

Efficacy and Cost-Effectiveness of Portable Small-Bore Chest Tube (Thoracic Egg Catheter) in Spontaneous Pneumothorax

  • Joh, Hyon Keun;Moon, Duk Hwan;Lee, Sungsoo
    • Journal of Chest Surgery
    • /
    • v.53 no.2
    • /
    • pp.49-52
    • /
    • 2020
  • Background: Primary spontaneous pneumothorax is commonly treated with chest tube insertion, which requires hospitalization. In this study, we evaluated the efficacy, costs, and benefits of a portable small-bore chest tube (Thoracic Egg; Sumitomo Bakelite Co. Ltd., Tokyo, Japan) compared with a conventional chest tube. Methods: We retrospectively analyzed all primary spontaneous pneumothorax patients who underwent treatment at Gangnam Severance Hospital between August 2014 and May 2018. Results: A total of 279 patients were divided into 2 groups: the conventional group (n=236) and the Thoracic Egg group (n=43). Of the 236 patients in the conventional group, 100 were excluded because they underwent surgery during the study period. The efficacy and cost were compared between the 2 groups. There was no statistically significant difference between the groups regarding recurrence (conventional group, 36 patients [26.5%]; Thoracic Egg group, 15 patients [29.4%]; p=0.287). However, the Egg group had statistically significantly lower mean medical expenses than the conventional group (433,413 Korean won and 522,146 Korean won, respectively; p<0.001). Conclusion: Although portable small-bore chest tubes may not be significantly more efficacious than conventional chest tubes, their use is significantly less expensive. We believe that the Thoracic Egg catheter could be a less costly alternative to conventional chest tube insertion.

Cerebral Air Embolism Following Pigtail Catheter Insertion for Pleural Fluid Drainage

  • Kim, Sa Il;Kwak, Hyun Jung;Moon, Ji-Yong;Kim, Sang-Heon;Kim, Tae Hyung;Sohn, Jang Won;Shin, Dong Ho;Park, Sung Soo;Yoon, Ho Joo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.74 no.6
    • /
    • pp.286-290
    • /
    • 2013
  • Pigtail catheter drainage is a common procedure for the treatment of pleural effusion and pneumothorax. The most common complications of pigtail catheter insertion are pneumothorax, hemorrhage and chest pains. Cerebral air embolism is rare, but often fatal. In this paper, we report a case of cerebral air embolism in association with the insertion of a pigtail catheter for the drainage of a pleural effusion. A 67-year-old man is being presented with dyspnea, cough and right-side chest pains and was administered antibiotics for the treatment of pneumonia. The pneumonia failed to resolve and a loculated parapneumonic pleural effusion developed. A pigtail catheter was inserted in order to drain the pleural effusion, which resulted in cerebral air embolism. The patient was administered high-flow oxygen therapy and recovered without any neurologic complications.

Development of Intravascular Micro Active Endoscope(II) -System Design, Fabrication and In-vitro Evaluation- (혈관 삽입용 초소형 작동형 내시경의 개발(II) - 시스템 설계, 제작 및 체외 성능 분석 -)

  • Chang, Jun-Keun;Chung, Seok;Lee, Yong-Ku
    • Tribology and Lubricants
    • /
    • v.15 no.3
    • /
    • pp.278-286
    • /
    • 1999
  • To predict the behavior of the intravascular micro active endoscope in the real human vascular system, a human mock circulation system was developed. The intravascular micro active endoscope which consists of micro active bending catheter and micro drug infusion catheter was driven in the velocity, Re number and temperature controlled flow. The three SMA (Shape Memory Alloy) zigzag type spring in the micro active bending catheter was heated by the electric current generated by PWM controller, and the shape memory effect made the actuator bend to any direction. The micro drug infusion catheter was driven through the inner hole of the micro active bending catheter. A mock circulation system is shaped from Ascending Arota to Femoral artery according to a human data (the data contains many vascular sizes and hydrographs of many control points). We developed a vascular model with glass and silicone tubes, and set the flow system with circulation parts, flow settling parts, and lots of valves. The heater and heat-controller was added to the How system to centre! the temperature of the How at 36.5$^{\circ}C$. The result showed that the developed intravascular micro active endoscope could be induced to any point in the vascular model.

Technical and Clinical Considerations for Successful Management of Postoperative Bowel Perforation by Percutaneous Foley Catheter Placement (경피적 폴리 카테터 삽입을 이용하여 수술 후 장 누출을 성공적으로 관리하기 위한 기술적 및 임상적 요인들)

  • So young Cho;Jung Suk Oh;Hae Giu Lee;Byung Gil Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1389-1396
    • /
    • 2020
  • Purpose The aim of this study was to analyze several technical and clinical factors associated with the successful management of postoperative leakage by percutaneous Foley catheter placement. Materials and Methods Thirty-two patients were included in this retrospective study. Postoperative gastrointestinal leakage was diagnosed by computed tomography (CT) and the patients underwent percutaneous Foley catheter placement into the leakage site through Jackson-Pratt tubes or imaging-guided methods. Clinical success was defined as successful Foley catheter removal without symptom recurrence within 1 week and the risk factors for clinical failure were analyzed. Results In all patients, percutaneous Foley catheter placement was successfully achieved without complications. Foley catheter was placed at a median of 10 days (range, 1-68) after the confirmation of leakage on CT. Clinical success was achieved in 26 of the 32 patients (81%). Systemic comorbidity (p < 0.001) and failed oral intake (p = 0.015) were the statistically significant risk factors for clinical failure. Conclusion Percutaneous Foley catheter placement can be considered an effective approach for the management of postoperative bowel leakage. The presence of systemic comorbidity and successful oral diet after Foley catheter placement are significant factors for successful clinical recovery.

Foreign Body Removal in Children Using Foley Catheter or Magnet Tube from Gastrointestinal Tract

  • Choe, Jae Young;Choe, Byung-Ho
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.22 no.2
    • /
    • pp.132-141
    • /
    • 2019
  • Foreign body (FB) ingestion of children is a common pediatric emergency requiring medical attention. Pediatric emergency physicians and gastroenterologists often encounter nervous and distressed situations, because of children presenting with this condition in the common clinical practice. When determining the appropriate timing and indications for intervention, physicians should consider multiple patient- and FB-related factors. The utilization of a flexible endoscopy is considered safe and effective to use in these cases, with a high success rate, for the effective extraction of FBs from the gastrointestinal tract of a child. Additionally, a Foley catheter and a magnet-attached Levin tube have been used for decades in the case of FB removal. Although their use has decreased significantly in recent times, these instruments continue to be used for several indications. Using a Foley catheter for this purpose does not require special training and does not necessarily require sedation of the patient or fluoroscopy, which serve as advantages of utilizing this method for foreign object retrieval. An ingested magnet or iron-containing FB can be retrieved using a magnet-attached tube, and can be effective to retrieve an object from any section of the upper gastrointestinal tract that can be reached. Simple and inexpensive devices such as Foley catheters and magnetattached tubes can be used in emergencies such as with the esophageal impaction of disk batteries if endoscopy cannot be performed immediately (e.g., in rural areas and/or in patients presenting at midnight in a facility, especially in those without access to endoscopes or emergency services, or in any situation that warrants urgent removal of a foreign object).

Comparison of Glucose Concentration of Tracheal Secretions by Measuring Times and Feeding Methods in Enterally Fed Patients (폐흡인군과 비폐흡인군의 측정 시간대 별 기관분비액 당농도와 경장영양액 제공 방법 비교)

  • Kim, Hwa Soon;Yoon, Mi Ja
    • Korean Journal of Adult Nursing
    • /
    • v.18 no.5
    • /
    • pp.718-726
    • /
    • 2006
  • Purpose: The purpose of this study was to investigate differences between a pulmonary aspiration group and a non-pulmonary aspiration group in glucose concentration of tracheal secretions by measuring time and feeding methods. Method: The subjects were 36 ICU patients who were receiving formula via nasogastric tubes and had endotracheal tubes or tracheostomy tubes. Tracheal secretions were collected by connecting suction traps to a suction catheter in three different times(within 1 hour after feeding, between 1 to 2 hours after feeding, and between 2 to 3 hours after feeding) for 2 days, overall six times. Glucose concentration of tracheal secretions was measured with the glucometer(Accucheck II). Results: Glucose concentration of tracheal secretions increased in progression after feeding. The mean of specimens collected last(between two to three hours after feeding) was shown to be the highest value(M=61.61mg/dl) in the pulmonary aspiration group. Significantly(p=.000) more subjects(94.44%) in the pulmonary aspiration group received formula via a 50cc syringe than those in the non-pulmonary aspiration group(22.22%). Conclusion: Critically ill patients may need more time for head-elevation after tube feeding to prevent pulmonary aspiration. In practice, enteral formula should not be given the patients via a $50_cc$ syringe anymore, instead a feeding bag or infusion pump should be used to prevent pulmonary aspiration.

  • PDF

Iatrogenic Perforation of the Left Ventricle during Insertion of a Chest Drain

  • Kim, Dongmin;Lim, Seong-Hoon;Seo, Pil Won
    • Journal of Chest Surgery
    • /
    • v.46 no.3
    • /
    • pp.223-225
    • /
    • 2013
  • Chest draining is a common procedure for treating pleural effusion. Perforation of the heart is a rare often fatal complication of chest drain insertion. We report a case of a 76-year-old female patient suffering from congestive heart failure. At presentation, unilateral opacity of the left chest observed on a chest X-ray was interpreted as massive pleural effusion, so an attempt was made to drain the left pleural space. Malposition of the chest drain was suspected because blood was draining in a pulsatile way from the catheter. Computed tomography revealed perforation of the left ventricle. Mini-thoracotomy was performed and the drain extracted successfully.

Consideration on Domestic Production of Materials and Consumables for Human IVF-ET Program (체외수정 및 배아이식술 관련 재료 및 소모품의 국산화 필요성에 대한 고찰)

  • Cha, Byung-Hun;Jun, Jin-Hyun
    • Development and Reproduction
    • /
    • v.15 no.4
    • /
    • pp.385-391
    • /
    • 2011
  • Human in vitro fertilization and embryo transfer (IVF-ET) program is a general procedure for infertile couples since first successful delivery on 1978 in UK and Korean first on 1985. Recently in Korea, more than 42,000 cases per year of IVF-ET were performed and showed good pregnancy rates compared worldwide data. The human IVF-ET procedure use many consumables, such as ovum pick-up (OPU) needles, centrifuge tubes, culture dish, ICSI pipette, culture media and ET catheters. Major of these materials are supported by the global companies. Thus, Korean IVF-ET program might be placed unstable situation by global economical risks. These uncertain problems could be overcome by the domestic production of IVF-ET materials and consumables. Two times questionnaires for Korean clinicians and researchers about the domestic production were performed and analyzed. Many of them requested domestic OPU needles, ET catheters, culture media and ICSI pipettes under good quality control and quality assurance system. This trial may be contributed to industrialization and to global competence of Korean IVF-ET program. The results of this survey can be provide a fundamental base for development and production of domestic materials and consumables for human IVF-ET program.

Determination of Carnitine Renal Threshold and Effect of Medium-Chain Triglycerides on Carnitine Profiles in Newborn Pigs

  • Heo, K.N.;Odle, J.;Lin, X.;van Kempen, T.A.T.G.;Han, In K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.2
    • /
    • pp.237-242
    • /
    • 2001
  • Colostrum deprived, newborn pigs (N=12, $1.64{\pm}0.05kg$) were used to study the renal threshold of carnitine, and effects of emulsified medium-chain triglyceride (MCT, tri-8:0) feeding on kinetics of plasma carnitine and urinary carnitine excretion. An arterial catheter was inserted through an umbilical artery, and a bladder catheter was inserted via the urachus. Piglets were oro-gastrically gavaged with one of six carnitine levels (0, 60, 120, 180, 240, $480{\mu}mol/kg\;W^{0.75}$) with (+MCT) or without medium-chain triglycerides (-MCT) in 0.9% NaCl solution. Blood was sampled into heparinized tubes at 0, 1, 2, 4, 6, 8, 14, and 20 h after gavage, and urine was collected and pooled into 1 h or 2 h composite samples to determine free- and short-chain carnitine concentrations. Plasma from the 12 newborn piglets before gavage contained $10.6{\pm}1.2{\mu}mol/L$ free carnitine and $7.2{\pm}0.6{\mu}mol/L$ acid-soluble acyl carnitine. The renal threshold for carnitine was similar between the MCT and the +MCT group (42.6 13.1 and $46.4{\pm}2.0{\mu}mol/L$, respectively), but the correlation between plasma free carnitine and urinary excretion was altered. Plasma free carnitine linearly increased with increasing carnitine dosage (-MCT group, $R^2=0.95$, p<0.001; +MCT group, $R^2=0.91$, p<0.001), but was decreased by 50% when medium-chain triglycerides were fed. The peak in plasma free carnitine concentration was depressed by medium-chain triglycerides feeding also. Therefore, the plasma and urinary short-chain/free carnitine ratio of the +MCT group was increased by 100% and 40%, respectively (p<0.01). Feeding of medium-chain triglycerides may delay plasma carnitine elevation via altering the kinetics of absorption. Similarly, the plasma and urinary short-chain/free carnitine ratio were affected by interaction between medium-chain triglycerides and time (p<0.01). The present study suggests that an oral carnitine dose over $480{\mu}mol/kg\;W^{0.75}$ may be needed to reach the free carnitine renal threshold within a short period, especially when provided together with medium-chain triglyceride.