• Title/Summary/Keyword: Cartridge Valve

Search Result 13, Processing Time 0.024 seconds

Discharge Coefficients of Orifice Hole in the Cartridge of Constant Flow Control Valve (정유량 밸브의 카트리지의 오리피스 구멍의 유출계수)

  • Yoo, Seon-Hak;Kang, Seung-Duk;Yang, Eui-Seok;Park, Kyung-Am
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.305-308
    • /
    • 2004
  • The constant flow control valve is used to control the flow rate of heating water in the large apartment complex and buildings. It is important to have similar heating flow rate in the apartments, even though the apartment is top or bottom floors. To achieve those purposes, the constant flow control valve was developed. The performance of this control valve is effected by hole area and discharge coefficients of the cartridge holes. The discharge coefficients of orifice hole in the cartridge were testes with various sizes of holes and various flow direction in the holes. The discharge coefficients decreased as the hole size increased due to the collision at the cartridge wall of water jet. The effects of the flow direction at the hole were not significant on the discharge coefficients.

  • PDF

Clamping force control of injection molding machine using 2-way cartridge valve based logic circuit (2-방향 카트리지 밸브 기반 로직회로에 의한 사출성형기의 형체력 제어)

  • Cho, Seung Ho
    • Journal of Drive and Control
    • /
    • v.13 no.2
    • /
    • pp.51-58
    • /
    • 2016
  • The present study deals with the issue of clamping force control of an injection molding machine using 2-way cartridge valve based logic circuit. The operating principle for the cartridge valve is described with its construction and static opening behavior. Basic module circuits are designed first and analysed according to the basic functions. Then they are combined with a virtual design model for the clamping mechanism to simulate the control performance of the overall system. The backlash inherent in the mechanism is considered while evaluating the time-delay in the process of clamping force build-up. The effects of a couple of design parameters in backlash, i.e., interval and stiffness have been demonstrated in the time-domain.

Development of a Flow Rate Sensor Using 2-way Cartridge Valve (2-유로 카트리지 밸브를 이용한 유압용 유량 센서의 개발)

  • 홍예선;이정오
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2381-2389
    • /
    • 1993
  • In this paper the design and test results of a dynamic flow rate sensor was reported. This sensor comprises an 2-way cartridge valve as standard hydraulic component and a displacement sensor. Its working principle bases on the linear relationship between the flow rate and the piston displacement of 2-way cartridge valves under constant pressure drop. This principle is well known, however it is not easy to develop a flow rate sensor with the measurement range of 300 1/min, pressure loss of less than 8 bar at 300 1/min, maximum linearity error of less than $\pm$1% and the maximum rising time of 10 ms. This paper describes the design procedure of the flow rate sensor, the improvement procedure of static performance and test method and results of dynamic performance.

A Study on Development of Hydraulic Pressure System Using Cartridge Valve (Cartridge Valve를 이용한 유압시스템 개발에 관한 연구)

  • Lee, Woo;Jung, Seok-Yoon;Kim, Sang-Gu;Kim, Kyung-Hoon;Byun, Seung-Nam
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1279-1282
    • /
    • 2003
  • The hydraulic pressure system can deliver strong power and control is easy so that it have been applied to the element technique of an each industrial field. Apply range is the actual circumstances to be more widening according to the automation plant and trend of the manufacture facilities. The hydraulic pressure system have been used since early times and it was universalized considerable in the industrialized country. Utilized to an automation device instrument wide at an each industrial spot and contributed the air space development which contribution make great strides for robotics and airospace departments. Our circuit design technology for the device structure are weak and in fact domestic is depending on the income though importance of the hydraulic pressure system.

  • PDF

Static and Dynamic Characteristics of Electro - hydraulic Proportional Throttle Control Valve (전자 유압식 비례 교축 제어 밸브의 특성)

  • 오인호;이일영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.87-99
    • /
    • 1993
  • Nowadays, the cartridge valve can be controlled proportionally in remote place by adopting proportional solenoid and it becomes widely used as control component in hydraulic systems. Especially, multi stage proportional valve is attractive because it consumes less input power though its characteristics might slightly be defected. But, the system parameter should be carefully chosen to obtain optimistic characteristics. This study concerning three stage proportional throttle control valve is purposed to examine the influences of paameters to the dynamic characteristics. The typical transient and frequency responses of proportional throttle control valve were inspected through the experiments and compared to those derived from the theoritical analyses. And it was confirmed that the analyses are appropriate. Then the influences of various system parameters to the dynamic characteristics were examined by means of simulations. For the analyses, the basic equations derived from lumped model were linearized and the linearized equations were transformed to the transfer functions between inputs and outputs. Then the transient responses and frequency responses were obtained from transfer functions. 1. It is appropriate to estimate the dynamic characteristics of valve which has relatively sophisticated structure by means of system analyses using linearized equations. 2. Though the valve has two pilot stages, fairly good characteristics can be obtained by carefully choosing system parameters. 3. Main valve very quickly follows the movement of second pilot valve when the parameters of main valve(the oil supply passage and discharge passage fpr second pilot valve) are appropriately chosen.

  • PDF

A Study on Dynamic Characteristics of Directional Control Logic Valve (방향제어 조직밸브의 동특성에 관한 연구)

  • Lee, Il-Yeong;Oh, Se-Kyung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.4
    • /
    • pp.172-179
    • /
    • 1988
  • A cartridge type hydraulic logic valve consists of simple two port valve whose poppet is closed or opened by means of pressure signal of a pilot line. Accordingly, the logic valve can be used not only for direction, flow and pressure control purpose but also for versatile function valve which enables all above mentioned functions. In addition, the valve has little internal leakage and pressure loss, superior response characteristics and easiness in making small block type valve. The above mentioned good performances being recognized recently, the logic valve has been used widely in the large scale hydraulic system such as a hydraulic press system, for the performance requirements of high speed operation and precise control characteristics. However, there are scarce reports until now, except for a few ones from Aachen Institute of Technology in West Germany, so it is necessary to be studied on development and investigation for practical application. This paper showed that the static and dynamic characteristics of a logic valve when the logic valve is used for directional control, to investigate the relations between the valve operating characteristics and the valve design conditions. From the above mentioned procedure, it was ascertained that the valve operation characteristics obtained by numerical analysis showed good agreements with experimental results. The representative results obtained are as follows; 1. During the valve is closing, the poppet velocity is almost constant in the logic valve. 2. The pilot pressure P sub(3) and the resistance R in the pilot line have much influences on the valve operation time. 3. Spring strength have not such a severe influence on the valve operating time. 4. The operation characteristics of the logic valve can be estimated with good accuracy comparatively by numerical analysis with the equations describing poppet motion.

  • PDF

Experiment and Simulation of Diffusion of Gas Released from the Relief Valve of a Gas Cylinder for a Portable Gas Range (압력 방출밸브를 장착한 이동식 부탄연소기용 부탄캔의 분출가스 확산 실험 및 해석)

  • Kang, Seung-Kyu;Choi, Kyung-Suhk;Yoon, Joon-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.1
    • /
    • pp.16-21
    • /
    • 2009
  • In the last five years, 91 accidents from portable gas ranges and non-refillable metallic gas cartridges have occurred. The gas cylinder installed with a relief valve was developed to prevent an explosive accident from the gas cartridge. In this study it was carried out to evaluate the safety of a gas cylinder mounted with a relief valve which can prevent an explosion. Under the real using condition and the extreme condition the gas cylinder is heated with an electric heater. Simultaneously, the operating pressure is checked and the suitability of releasing flux is evaluated. And the possibility of fire or explosion was tested when the gas was released from the relief valve at the real using condition. Using a numerical simulation method, the diffusion of butane gas released from a relief valve was visualized.

Fabrication of a Micro Scent Injector (초소형 향 분사 모듈의 제작)

  • Park, Tae-Gyu;Yang, Sang-Sik;Kim, Yeong-Sik;Lee, Sang-U
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.12
    • /
    • pp.633-638
    • /
    • 2001
  • The paper presents the fabrication and test of a micro scent injector module. A micro scent injector module consists of an injector fabricated by micromachining, a scent cartridge and a controller. If a scent injection signal triggers the controller, it heats the scent liquid in the injector chamber and a scent liquid is vaporized. The increased vapor pressure opens a normally closed boss valve, and the scent vapor is injected through the opened nozzle. The liquid volume injected by the fabricated module is about $1\muell$ for one second at 2 W.

  • PDF

Consecutive automated production of carbon-11 labeled radiopharmaceuticals by sharing 11C-methylation reagent from one 11C-synthetic module

  • Park, Hyun Sik;Lee, Hong Jin;An, Hyun Ho;Moon, Byung Seok;Lee, Byung Chul;Kim, Sang Eun
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.2 no.2
    • /
    • pp.123-131
    • /
    • 2016
  • Increasing clinical demand for carbon-11 labeled radiopharmaceuticals has triggered technological advances in fields of radiochemistry and automated modules. Even though carbon-11 has a short half-life ($t_{1/2}=20.4min$), the consecutive second production of carbon-11 labeled radiopharmaceutical in one $^{11}C$-synthetic module should be delayed at least over 4 h to avoid the high radiation exposure. We herein aimed to produce two different carbon-11 labeled radiopharmaceuticals ([$^{11}C$]PIB and [$^{11}C$]methionine) by sharing of [$^{11}C$]methylation source in one $^{11}C$-synthetic module. The synthesis of $^{11}C$-labeling reagents ($[^{11}C]CH_3I$ or $[^{11}C]CH_3OTf$) is fully automated using the commercial TRACERlab $FX_{C-pro}$ module and is readily adaptable to $^{11}C$-labeling reactor for [$^{11}C$]PIB as well as another $^{11}C$-labeling apparatus for [$^{11}C$]methionine via the three-way valve. After completing the [$^{11}C$]PIB production, the re-synthesized $[^{11}C]CH_3I$ was passed through the three-way valve connected the polyetheretherketone (PEEK) line and loaded into the C18 Sep-Pak cartridge including the methionine precursor. The labeled product [^${11}C$]methionine was purified by a simple cartridge separation and reformulated into saline. The radiochemical yield of [$^{11}C$]PIB and [$^{11}C$]methionine were $5.3{\pm}0.6%$ and $18.7{\pm}0.8%$ (n.d.c.), respectively, with over 97% of radiochemical purity. The specific activity of [$^{11}C$]PIB was over $110GBq/{\mu}mol$. Total production time of two radiopharmaceuticals needs about 2 h from $1^{st}$ beam irradiation including quality control tests. Final [$^{11}C$]PIB and [$^{11}C$]methionine were satisfied all quality control test standards.