• Title/Summary/Keyword: Carbon Paste Electrode

Search Result 115, Processing Time 0.029 seconds

Electrocatalytic Properties of Metal-dispersed Carbon Paste Electrodes for Reagentless L-lactate Biosensors (금속이 첨가된 탄소전극의 전기화학적 특성과 이를 이용한 L-lactate 바이오센서의 개발)

  • 윤현철;김학성
    • KSBB Journal
    • /
    • v.11 no.4
    • /
    • pp.489-496
    • /
    • 1996
  • Metal dispersed carbon paste electrodes were fabricated, and their electrochemical properties were investigated. Among various metal dispersed carbons, platinum-dispersed carbon paste electrode showed most efficient electrocatalytic characteristics. The overpotential for the oxidation of NADH was significantly lowered in the platinum-dispersed carbon paste electrode, and catalytic current was also enhanced. Based on these electrocatalytic observations, L-lactate biosensor using L-lactate dehydrogenase was constructed to evaluate its performance in terms of sensitivity and stability.

  • PDF

Electrochemical determination of hydrogen peroxide using carbon paste biosensor bound with butadiene rubber (부타디엔 고무로 결합된 탄소반죽 바이오센서를 이용한 과산화수소의 전기화학적 정량)

  • Yoon, Kil-Joong
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.505-510
    • /
    • 2010
  • When polybutadiene dissolved in toluene was a binder of carbon powder, the volatility of solvent just after electrode fabrication assured the mechanical solidity of the carbon paste electrode. This characteristic met the qualifications for practical use of carbon paste electrodes. A new enzyme electrode bound with butadiene rubber was constructed. In order to confirm whether it shows quantitative electrochemical behaviors or not, its electrochemical kinetic parameters, e.g. the symmetry factor, the exchange current density, the capacitance of double layer, the time constant, the maximum current, the Michaelis constant and other factors were investigated. These experimental facts showed that butadiene rubber is a recommendable binder for practical use of a carbon paste electrode.

Voltammetric Determination of Cobalt(Ⅱ) Using Carbon Paste Electrodes Modified with 1-(2-Pyridylazo)-2-naphthol

  • 배준웅;박유철;이상학;전우성;장혜영
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.11
    • /
    • pp.995-999
    • /
    • 1996
  • A method for the determination of cobalt(Ⅱ) by differential pulse voltammetry using a carbon paste electrode constructed by incorporating 1-(2-pyridylazo)-2-naphthol(PAN) into a conventional carbon paste mixture composed of graphite powder and Nujol oil has been developed. Several influencing factors for the determination of cobalt(Ⅱ) were studied in detail and the optimum analytical conditions were found to be as follows: pH, 4.6; composition of electrode, 20%; temperature of deposition, 43 ℃; time of preconcentration, 15 min. Regeneration of the electrode surface for the continuous uses of the electrode was achieved by exposing the carbon paste electrode to an acidic solution. Response of the electrode was reproducible for the uses of five times and the relative standard deviations were 6.7 and 4.6% for 2.0×10-5 M and 4.0×10-6 M cobalt(Ⅱ), respectively. The calibration curve for cobalt(Ⅱ) obtained by differential pulse voltammetry was divided into two linear ranges of 1.7× 10-6-1.3×10-4 M and 2.0×10-7-8.0×10-7 M. The detection limit was estimated to be 1.3×10-7 M. The effects of coexisting ions were also investigated to test the applicability of the proposed method to the determination of cobalt(Ⅱ) in real samples.

Voltammetric Determination of Bisphenol A Using a Carbon Paste Electrode Based on the Enhancement Effect of Cetyltrimethylammonium Bromide (CTAB)

  • Huang, Wensheng
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.10
    • /
    • pp.1560-1564
    • /
    • 2005
  • The influence of cetyltrimethylammonium bromide (CTAB) on the electrochemical behavior of bisphenol A at the carbon paste electrode (CPE) was investigated. CTAB, with a hydrophobic C-H chain, can adsorb at the CPE surface via hydrophobic interaction and then change the electrode/solution interface, and finally affects the electrochemical response of bisphenol A, confirming from the remarkable oxidation peak current enhancement. The electrode process of bisphenol A was examined, and then all the experimental parameters which affects the electrochemical response of bisphenol A, such as pH value of the supporting electrolyte, accumulation potential and time, potential scan rate and the concentration of CTAB, were examined. Finally, a sensitive and simple voltammetric method was developed for the determination of bisphenol A. Under the optimum conditions, the oxidation peak current of bisphenol A varied linearly with its concentration over the range from $2.5\;{\times}\;10^{-8}\;to\;1\;{\times}\;10^{-6}$ mol/L, and the detection limit was found to be $7.5\;{\times}\;10^{-9}$ mol/L. This method was successfully employed to determine bisphenol A in some waste plastic samples.

Characteristics of ${\alpha}$-Cyclodextrin Modified Carbon Paste Electrode (${\alpha}$-Cyclodextrin으로 화학수식된 Carbon Paste 전극의 특성)

  • Jeon, Young-Guk;Kim, Bong-Weon;Kim, Hee-Jung;Cho, Young-Dal;Chung, Chinkap
    • Analytical Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.235-243
    • /
    • 1996
  • A carbon paste electrode were chemically modified using ${\alpha}$-cyclodextrin. Characteristics of chemically modified carbon paste electrodes were studied on the basis of the inclusion complex formation of ${\alpha}$-cyclodextrin and p-nitrophenol in solution. Cyclic voltammetry and differential pulse voltammetry were used to monitor the efficiency of the chemical modification. When the ${\alpha}$-cyclodextrin and carbon powder ratio of 2 : 1 in weight were used, the reduction peak current of p-nitrophenol was decreased almost completely, whereas those of o-nitrophenol and hydroquinone were not changed much. This result is due to the large difference in the inclusion complex formation constants of p-nitrophenol and the other probes with ${\alpha}$-cyclodextrin. Taking advantage of this difference, we can determine the concentration of o-nitrophenol even in the presence of p-nitrophenol.

  • PDF

Studies on Enhanced Oxidation of Estrone and Its Voltammetric Determination at Carbon Paste Electrode in the Presence of Cetyltrimethylammonium Bromide

  • Yang, Chunhai;Xie, Pingping
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.10
    • /
    • pp.1729-1734
    • /
    • 2007
  • The electrochemical behaviors of estrone in the presence of various surfactants were examined with great details. It is found that a cationic surfactant, cetyltrimethylammonium bromide (CTAB), obviously facilitates the electro-oxidation of estrone at carbon paste electrode (CPE) from the significant peak current enhancement and the negative shift of peak potential. Additionally, chronocoulometry and electrochemical impedance spectroscopy (EIS) were also used for further investigation of the electrode process of estrone, indicating that low concentration of CTAB exhibits excellent enhancement effects on the electrochemical oxidation of estrone, greatly enhances the diffusion coefficient and the electron transfer rate. Based on this, an electrochemical method was proposed for the determination of estrone. The oxidation peak current is proportional to the concentration of estrone in the ranges over 9.0 × 10?8 - 8.0 × 10?6 mol/L, and a low detection limit of 4.0 × 10?8 mol/L was obtained for 180s accumulation at open circuit (S/N = 3). Finally, this proposed method was demonstrated using estrone tablets with good satisfaction.

Green Synthesized Cobalt Nano Particles for using as a Good Candidate for Sensing Organic Compounds

  • Siada, S. O. Ranaei
    • Journal of Electrochemical Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.111-115
    • /
    • 2015
  • In this work electrochemical oxidation of Ascorbic acid (AA) on the surface of Cobalt nano particle modified carbon paste electrode (CoNPsMCPE) was studied in alkaline media. CoNPs were green synthesized using Piper longum and a mixture of 5% (w/w) of it were made with carbon paste. CoNPs showed good electrocatalytic activity in alkaline media. Cyclic voltammetry (CV) and chronoamperometry (CA) were used to study the electrochemical performance of CoNPsMCPE. The number of monolayers on the surface of electrode was calculated as 1.08×109 mol cm−2 that is equal to that of metal Cobalt electrode. Diffusion coefficient of AA was determined using CA analysis which was equal to 1.5×10−6cm2 s−1.

Physioelectrochemical Investigation of Electrocatalytic Activity of Modified Carbon Paste Electrode in Alcohol Oxidation as Anode in Fuel Cell

  • Shabani-Shayeh, Javad;Ehsani, Ali;Jafarian, Majid
    • Journal of the Korean Electrochemical Society
    • /
    • v.17 no.3
    • /
    • pp.179-186
    • /
    • 2014
  • Methanol electro oxidation on the surface of carbon paste modified by $NiCl_2/6H_2O$ was studied in 1M NaOH by potentiostatic and potentiodynamic methods. Ni/C catalyst by the concentration of 5% Ni showed about twice higher electro catalytic activity than Ni metal. The amount of monolayer's on the surface of electrode is almost one order higher for Ni/C than Ni electrode. The kinetic parameters and the diffusion coefficient of methanol were derived from chronoamperometry (CA) and electrochemical impedance spectroscopy (EIS) measurements.

Simultaneous Determination of Cd2+, Pb2+, Cu2+ and Hg2+ at a Carbon Paste Electrode Modified with Ionic Liquid-functionalized Ordered Mesoporous Silica

  • Zhang, Penghui;Dong, Sheying;Gu, Guangzhe;Huang, Tinglin
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.10
    • /
    • pp.2949-2954
    • /
    • 2010
  • Ionic liquid-functionalized ordered mesoporous silica SBA-15 modified carbon paste electrode (CISPE) was fabricated and its electrochemical performance was investigated by cyclic voltammetry, electrochemical impedance spectra. The electrochemical behavior of $Cd^{2+}$, $Pb^{2+}$, $Cu^{2+}$ and $Hg^{2+}$ at CISPE was studied by differential pulse anodic stripping voltammetry (DPASV). Compared with carbon paste electrode, the stripping peak currents had a significant increase at CISPE. Under the optimized conditions, the detection limits were $8.0{\times}10^{-8}\;M$ ($Cd^{2+}$), $4.0{\times}10^{-8}\;M$ ($Pb^{2+}$), $6.0{\times}10^{-8}\;M$ ($Cu^{2+}$), $1.0{\times}10^{-8}\;M$ ($Hg^{2+}$), respectively. Furthermore, the present method was applied to the determination of $Cd^{2+}$, $Pb^{2+}$, $Cu^{2+}$ and $Hg^{2+}$ in water samples and people hair sample.

Nanogold-modified Carbon Paste Electrode for the Determination of Atenolol in Pharmaceutical Formulations and Urine by Voltammetric Methods

  • Behpour, M.;Honarmand, E.;Ghoreishi, S.M.
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.4
    • /
    • pp.845-849
    • /
    • 2010
  • A gold nanoparticles modified carbon paste electrode (GN-CPE) has been used for the determination of atenolol (ATN) in drug formulations by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronocoulometric methods. The results revealed that the modified electrode shows an electrocatalytic activity toward the anodic oxidation of atenolol by a marked enhancement in the current response in buffered solution at pH 10.0. The anodic peak potential shifts by -80.0 mV when compared with the potential using bare carbon paste electrde. A linear analytical curve was observed in the range of $1.96\;{\times}\;10^{-6}$ to $9.09\;{\times}\;10^{-4}\;mol\;L^{-1}$. The detection limit for this method is $7.3\;{\times}\;10^{-8}\;mol\;L^{-1}$. The method was then successfully applied to the determination of atenolol in tablets and human urine. The percent recoveries in urine ranged from 92.0 to 110.0%.