• Title/Summary/Keyword: Capillary method

Search Result 508, Processing Time 0.025 seconds

The Screening and Pattern Comparison of Organic Acids in 3 Kinds of Medicinal Herbal Extracts (3가지 약용 허브 추출물에 함유된 유기산 검색 및 조성 비교)

  • Chung, Ha-Yull;Jung, Do-Hyun;Park, Young-Joon
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.997-1001
    • /
    • 2000
  • The organic acids in 3 kinds of medicinal herbal extracts were screened and compared each other according to their organic acid contents by an efficient gas chromatographic method. It involves solid-phase extraction of organic acids using Chromosorb P with subsequent conversion to stable tert-butyldimethysilyl derivatives for the direct analysis by capillary column gas chromatography and gas chromatography-mass spectrometry. Total of 24 organic acids were reproducibly identified from 3 kinds of herbal extracts. When the GC profiles were simplified to their retention index spectra, characteristic patterns were obtained for each herb sample. As expected, three kinds of herbal extracts showed three distinct patterns.

  • PDF

Capillarity-Driven Self-Assembly of Silver Nanowires-Coated Fibers for Flexible and Stretchable Conductor

  • Li, Yi;Chen, Jun;Han, Xiao;Li, Yinghui;Zhang, Ziqiang;Ma, Yanwen
    • Nano
    • /
    • v.13 no.12
    • /
    • pp.1850146.1-1850146.9
    • /
    • 2018
  • The rapid development of smart textiles requires the large-scale fabrication of conductive fibers. In this study, we develop a simple, scalable and low-cost capillary-driven self-assembly method to prepare conductive fibers with uniform morphology, high conductivity and good mechanical strength. Fiber-shaped flexible and stretchable conductors are obtained by coating highly conductive and flexible silver nanowires (Ag NWs) on the surfaces of yarn and PDMS fibers through evaporation-induced flow and capillary-driven self-assembly, which is proven by the in situ optical microscopic observation. The density of Ag NWs and linear resistance of the conductive fibers could be regulated by tuning the assembly cycles. A linear resistance of $1.4{\Omega}/cm$ could be achieved for the Ag NWs-coated nylon, which increases only 8% after 200 bending cycle, demonstrating high flexibility and mechanical stability. The flexible and stretchable conductive fibers have great potential for the application in wearable devices.

Optimization of Ascorbic Acid Encapsulation in PLA Microcapsules Using Double Emulsion Process (이중유화법을 이용한 PLA 마이크로캡슐 내부로의 아스코르브산 캡슐화 공정 최적화)

  • Ji Won Yun;Young Mi Chung
    • Applied Chemistry for Engineering
    • /
    • v.35 no.2
    • /
    • pp.115-121
    • /
    • 2024
  • This study analyzed the influence of process variables affecting the thermodynamic equilibrium and fluid dynamics of interfaces such as reverse micelle, salt concentration, interfacial tension, and viscosity of fluids to optimize the microencapsulation process using the W1/O/W2 double emulsion method. The process variable with the greatest impact on encapsulation efficiency was found to be the difference in osmotic pressure between the W1 and W2 phases. It was observed that increasing the salt concentration in the W2 phase or decreasing the ascorbic acid concentration in the W1 phase resulted in higher encapsulation efficiency. Additionally, a larger difference in osmotic pressure led to increased damage to the surface of the microparticles, as confirmed by SEM images. The introduction of reverse micelles, which was anticipated to increase encapsulation efficiency, either had a low contribution or even decreased encapsulation efficiency. The yield of microcapsules was expressed as a universal function, applicable to all process conditions or solution compositions. According to this universal function, no further increase in yield was observed beyond the Ca (capillary number) of approximately 20.

Development of Analytical Method for Fenoxanil in Agricultural Products Using GC-NPD and GC/MS (농산물 중 Fenoxanil 잔류성 시험법 개발)

  • Kim, Gyeong-Ha;Ahn, Kyung-Geun;Kim, Gi-Ppeum;Hwang, Young-Sun;Lee, Young Deuk;Choung, Myoung-Gun
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.4
    • /
    • pp.345-353
    • /
    • 2015
  • The aim of this study is to develop residue analysis method for fenoxanil, a MBI (melanin biosynthesis inhibitor) propionamide fungicide, had mainly been used to control rice blast, and disease of other crops, fruits, and vegetables by using GLC/NPD and GC/MS. Extraction with acetone and partition with n-hexane/dichloromethane (80/20, v/v) were performed from hulled rice, soybean, Kimchi cabbage, green pepper, and apple, then column clean-up with florisil was applied. Mean recoveries were 82.2%-109.1% with less than 7.2% of coefficients of variation and limit of quantitation was set at the concentration of 0.04 mg/kg from the five agricultural products through the determination by GLC/NPD equipped with DB-5 capillary column and single laboratory validation. As a confirmatory method, GC/MS selected ion monitoring (SIM) was set from m/z 125.0, 188.9, and 293.0. Developed method is expected to apply the single residue analysis of fenoxanil in agricultural products.

A Study of Cosmetic Sustainability Evaluation of Powder Base Make-up Products (파우더 베이스 메이크업 제품의 지속성 평가 방법 연구)

  • Lee, Sang Gil;Kim, Ki Jung;Kim, Young Ho;Pyo, Hyeong Bae;Lee, Dong Kyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.41 no.3
    • /
    • pp.209-218
    • /
    • 2015
  • Once powder base makeup products are applied to the skin, the products are formed a film and attached on the skin for 8 to 12 hours. The makeup film is deformed by secretions such as sweat and sebum secreted from the skin. Thus, durability of the film is an important quality factor in the makeup and its evaluation is also important. In this study, characteristics of the semi-finished powder products such as water absorption, oil absorption, water repellent and oil repellent were evaluated in a number of ways. Also, simple methods, which are not affected by evaluation conditions such as a difference between sweat and sebum secretion, temperature and humidity, were examined to predict the durability of the products. We measured water absorption, oil absorption, water repellent and oil-repellent properties of semifinished product by tablet, capillary and dipping method and then compared with the data of color difference meter and ROBO skin analyzer. Results showed that the durability of powder base makeup products was associated with more oil absorption and water-repellent characteristics than water absorption and oil-repellent. Oil absorption characteristics by tablet and capillary method and water-repellent characteristics by dipping method provides a simple and quick method to precdict the durability of the makeup products.

Fast Microchip Electrophoresis Using Field Strength Gradients for Single Nucleotide Polymorphism Identification of Cattle Breeds

  • Oh, Doo-Ri;Cheong, Il-Cheong;Lee, Hee-Gu;Eo, Seong-Kug;Kang, Seong-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1902-1906
    • /
    • 2010
  • A microchip electrophoresis (ME) method was developed using a programmed field strength gradients (PFSG) for the single nucleotide polymorphism (SNP) based fast identification of cattle breeds. Four different Korean cattle (Hanwoo) and Holstein SNP markers amplified by allele-specific polymerase chain reaction were separated in a glass microchip filled with 0.5% poly(ethyleneoxide) ($M_r$ = 8 000 000) by PFSG as follows: 750 V/cm for 0 - 14 s, 166.7 V/cm for 14 - 31 s, 83.3 V/cm for 31 - 46 s, and 750 V/cm for 46 - 100 s. The cattle breeds were clearly distinguished within 45 s. The ME-PFSG method was 7 times and 5 times faster than the constant electric field ME method and the capillary electrophoresis- PFSG method, respectively, with a high resolving power ($R_s$ = 5.05 - 9.98). The proposed methodology could be a powerful tool for the fast and simultaneous determination of SNP markers for various cattle breeds with high accuracy.

Solid-Phase Extraction of L-Muscone from Aqueous Samples with Amberlite XAD-4 for Gas Chromatographic Assay

  • Paik, Man-Jeong;Kim, Kyoung-Rae
    • Archives of Pharmacal Research
    • /
    • v.27 no.5
    • /
    • pp.539-543
    • /
    • 2004
  • An efficient analytical method was devised for the accurate L-muscone assay in aqueous samples. It involves solid-phase extraction of L-muscone in adsorption mode using XAD-4 as the sorbent and dichloromethane modified with 10% (v/v) methanol as the eluting solvent. The gas chromatographic analysis of the eluate residue dissolved in toluene on a DB-5MS capillary column provided complete resolution of L-muscone from the co-extracted interferences. The overall method showed excellent linearity ($r^2{\geq}$ 0.9994) in the range of 0.1 to 2.0 $\mu\textrm{g}$/mL with good intra- and inter-day precisions (% RSD = 2.5~7.3) and with high extraction recovery rates ($\geq$ 98.1 %). When the present method was applied to a L-muscone herbal drink product, the within-batch RE (%) in the labeled concentration (1.5 $\mu\textrm{g}$/mL) for the three randomly chosen bottles were -2.4, -1.3 and -3.3 with high precision (% RSD $\leq$ 3.1). The present method is considered to be suitable for quality control evaluation on liquid drinks and other complex formulations fortified with L-muscone.

The SWSV signal analysis for decision of heavy metal ion concentration using digital signal processing method (디지털신호처리기법을 이용한 중금속이온농도 결정의 SWSV 신호분석)

  • Lee, Jae choon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.5 no.4
    • /
    • pp.11-17
    • /
    • 2009
  • Polarography is a subclass of voltammetry where the working electrode is a dropping mercury electrode. More, I developed the experiment for raising up mercury electrode. In Voltammetry, information about an analyte is obtained by measuring the current as the potential is varied at oxidation-reduction reaction. A plot of current vs. potential in a polarography experiment shows the current oscillations correspoding to the drops of Hg falling from the capillary. The drops growth causes capacitive and faradic current. These changing current effects combined with experiments where the potential is continuously changed can result in noisy traces. The raising up type improved upon the method of dropping in hardware. In reduction of the noise, moving average smoothing method have been used. But the other procedure is introduced based on Fourier transformation. So FFT and IFFT engine was implemented and installed in my experiment. However, after experimentation, peak height as the measuring parameter gave a good linear relationship to concentration. The resolution of potential peaks of various kinds, using Zn and Cu as the example, was improved using the smoothing method.

Development of Spray Thin Film Coating Method using an Air Pressure and Electrostatic Force (공압과 정전기력을 이용한 스프레이 박막 코팅 기술 개발)

  • Kim, Jung Su;Kim, Dong Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.6
    • /
    • pp.567-572
    • /
    • 2013
  • In many electro-devices, the vacuum process is used as the manufacturing process. However, the vacuum process has a problem, it is difficult to apply to a continuous process such as a R2R(roll to roll) printing process. In this paper, we propose an ESD (electro static deposition) printing process has been used to apply an organic solar cell of thin film forming. ESD is a method of liquid atomization by electrical forces, an electrostatic atomizer sprays micro-drops from the solution injected into the capillary with electrostatic force generated by electric potential of about several tens kV. The organic solar cell based on a P3HT/PCBM active layer and a PEDOT:PSS electron blocking layer prepared from ESD method shows solar-to-electrical conversion efficiency of 1.42% at AM 1.5G 1sun light illumination, while 1.86% efficiency is observed when the ESD deposition of P3HT/PCBM is performed on a spin-coated PEDOT:PSS layer.

Studies on the Analysis of Tobacco Leaf Alkaloids (잎담배 Alkaloid분석에 관한 연구)

  • 장기철;한상빈;김용옥;이운철
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.13 no.2
    • /
    • pp.20-26
    • /
    • 1991
  • This study was carried out to develop the method of alkaloids analysis and investigate the kinds and contents of alkaloids in flue-cured, burley and oriental tobacco leaves using developed analytical method. The developed analytical method of alkaloids was as followed : Tobacco sample was treated with acid(pH 2∼3) and extracted with chloroform to remove chemical components except alkaloids. Sample solution was treated with alkali(pH 12∼ 13) and was extracted with chloroform to obtain alkaloids from sample solution. After extraction of alkaloids from tobacco leaves, alkaloids were separated and identified by GC, GC/MS using SE-54 fused silica capillary column. Nicotine, nornicotine, myosmine, 9-nicotyline, anabasine, anatabine, 2, 3-bipyridyl, cotinine, formyl nornicotine, acetyl nornicotine and formal anatabine were isolated and identified from the extracts of tobacco leaves. The contents of alkaloids were burley > flue-cured > oriental tobacco leaves, but oriental tobacco leaves were higher nornicotine, cotinine, formyl nornicotine and acetyl nornicotine contents than those of flue-cured tobacco leaves. The burley tobacco harvested in Korea was higher nornicotine contents by 2-6 times in the portions of cutter, leaf and tips position than that of burley tobacco(B3F) harvested in V. S. A.

  • PDF