• Title/Summary/Keyword: Capillary dimension

Search Result 16, Processing Time 0.029 seconds

A Study of the Chaotic Analysis of Flow of Capillary Blood Vessel by glucose index (Rabbit의 당수치에 따른 모세혈관 혈류의 카오스적 분석에 대한 연구)

  • Choi, J.Y.;Cho, C.Y.;Kim, D.H.;Im, J.D.;Im, J.J.;Nam, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.258-262
    • /
    • 1996
  • The physiological systems have nonlinear complex phenomena. Expecially, the flow of capillary blood vessel has a nonlinear dynamic system. Thus, this study analyzes nonlinear characteristics of the flow of capillary blood vessel in physiological systems using chaotic tools(phase space reconstruction, correlation dimension, largest lyapunov exponent). Experimental data have been acquired from examining 10 rabbits. The results of chaotic analysis showed a decreasing largest lyapunov exponent and correlation dimension according to increasement glocose index. And we also know the chaotic behavior.

  • PDF

Dimension Analysis of Chaotic Time Series Using Self Generating Neuro Fuzzy Model

  • Katayama, Ryu;Kuwata, Kaihei;Kajitani, Yuji;Watanabe, Masahide;Nishida, Yukiteru
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.857-860
    • /
    • 1993
  • In this paper, we apply the self generating neuro fuzzy model (SGNFM) to the dimension analysis of the chaotic time series. Firstly, we formulate a nonlinear time series identification problem with nonlinear autoregressive (NARMAX) model. Secondly, we propose an identification algorithm using SGNFM. We apply this method to the estimation of embedding dimension for chaotic time series, since the embedding dimension plays an essential role for the identification and the prediction of chaotic time series. In this estimation method, identification problems with gradually increasing embedding dimension are solved, and the identified result is used for computing correlation coefficients between the predicted time series and the observed one. We apply this method to the dimension estimation of a chaotic pulsation in a finger's capillary vessels.

  • PDF

Basic Analysis on Fractal Characteristics of Cement Paste Incorporating Ground Granulated Blast Furnace Slag (고로슬래그 미분말 혼입 시멘트 페이스트의 프랙탈 특성에 관한 기초적 분석)

  • Kim, Jiyoung;Choi, Young Cheol;Choi, Seongcheol
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.1
    • /
    • pp.101-107
    • /
    • 2017
  • This study aimed to conduct the basic analysis on the fractal characteristics of cementitious materials. The pore structure of cement paste incorporating ground granulated blast furnace slag (GGBFS) was measured using mercury intrusion porosimetry (MIP) and the fractal characteristics were investigated using different models. Because the pore structure of GGBFS-blended cement paste is an irregular system in the various range from nanometer to millimeter, the characteristics of pore region in the different scale may not be adequately described when the fractal dimension was calculated over the whole scale range. While Zhang and Li model enabled analyzing the fraction dimension of pore structure over the three divided scale ranges of micro, small capillary and macro regions, Ji el al. model refined analysis on the fractal characteristics of micro pore region consisting of micro I region corresponding to gel pores and micro II region corresponding to small capillary pores. As the pore size decreased, both models suggested that the pore surface of micro region became more irregular than macro region and the complexity of pores increased.

Pits Role in Embolism Repair of Populus tomentiglandulosa T. Lee

  • Chun, Su-Kyoung;Ahmed, Sheikh Ali
    • Journal of the Korea Furniture Society
    • /
    • v.18 no.2
    • /
    • pp.147-151
    • /
    • 2007
  • This report explains the intervessel pit dimension of Populus tomentiglandulosa and its role in embolism repair according to proposed mechanism by Zwieniecki and Holbrook, 2000. It was found that mean contact angle ( ) of water droplets on the inner surface of vessels was $56^{\circ}$. Openings into the bordered pits were typically elliptical. The angle of the bordered pit chamber ($2{\alpha}$) was found $142.17^{\circ}$. From the capillary equation $Pmax\;=\;Gcos\;(\;+{\alpha})$, it was found that mathematically the maximum pressure 0.08MPa created by pits, can be employed to force the air within the embolized vessel into solution.

  • PDF

A Comparative Study on the Conditioning and Dewaterability of Digested Sludge from Intermittent Aerobic Digestion (간헐포기 소화슬러지의 개량과 탈수 특성에 관한 비교 연구)

  • Kim, Seong Hong;Choi, Young Gyun;Chung, Tai Hak
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.4
    • /
    • pp.370-375
    • /
    • 2004
  • Synthetic organic polyelectrolytes can be used to condition sludges to enhance their dewaterability. When conditioning biological sludges, the charge on the polymer has a significant impact on the effectiveness of the polymer as a conditioner. The objectives of this investigation were to determine the most effective type and dosage of polymer for conditioning digested sludge prior to dewatering, and to investigate the relationship between dewaterability and particle size. 3 types of digested sludge were used under the different digestion processes like anaerobic digestion, aerobic digestion and intermittent aerobic digestion. CST(capillary suction time), TTF(time-to-filter) and SRF(specific resistance to filtration) were tested as a dewaterability index and the number of particle distribution was analyzed using particle size analyzer. The results indicate that cationic polymer appears to be required for effective conditioning of these 3 types digested sludge and the optimal polymer dosage is about 0.6% of SS. CST and TTF are well correlated with mean particle diameter of which the dimension order is 1.7.

Mechanical Degradation of Polymers in Dilute Solution (III). The Influence of the Mixed Solvents (稀薄溶液에서의 Polymer의 機械的 切斷 (제3보). 混合溶媒의 영향)

  • Yeong Moo Won
    • Journal of the Korean Chemical Society
    • /
    • v.17 no.3
    • /
    • pp.207-212
    • /
    • 1973
  • The mechanical degradation of poly (-vinylacetate) in several mixed solvents (dioxane-n-butanol, dioxane-sec-butanol, dioxane-ethyleneglycol, dioxane-kerosene.) was studied using the capillary flow method. The velocity constant of scission reaction (k) and the limited degree of polymerization (g) were compared at the same value of [${\eta}$], which is considered as the parameter of molecular dimension of polymers in solution. As result, (k) did not change much, even if the species and the volume fraction of poor (non-) solvents changed, while the value of (g) changed according to the species of poor solvents and the value of [${\eta}$]. From the facts described above, It follows that the limited degree of polymerization (g) were affected by the composition and distribution of mixed solvent molecules around the polymer chain, and the value of $\alpha$ (at [${\eta}$] = $KM^a$) in the polymer solution.

  • PDF

Mechanical Degradation of Polymers in Dilute Solution. The Influence of the Mixed Solvents II. (稀搏溶液에서의 Polymer의 機械的 切斷. 混合溶媒의 영향 Ⅱ)

  • Yeong Moo Won
    • Journal of the Korean Chemical Society
    • /
    • v.16 no.1
    • /
    • pp.50-55
    • /
    • 1972
  • The mechanical degradation of $poly(\alpha-methyl$ styrene) in several mixed solvents (chlorobenzene-n-butyl alcohol, chlorobenzene-sec-butyl alcohol, chlorobenzene-Kerosene, chlorobenzene-methylketone) was studied using the capillary flow method. The velocity constant of scission reaction (K) and the limited degree of polymerization (g) were compared at the same value of [${\eta}$], which is considered as the parameter of molecular dimension of polymers in solution. As results, (K) did not change much, even if the species and the volume fraction of poor(non-) solvents changed, while the value of (g) changed according to the species of poor (non-) solvents and the value of [${\eta}$] these results were discussed.

  • PDF

Analysis on a Dynamic Model with One Dimension in Water Transportation of PEM Fuel Cell (PEM연료전지의 수분전달에 있어서 1차원 해석을 수행한 동적모델에 관한 연구)

  • Bakhtiar, Agung;Hong, Boo-Pyo;You, Jin-Kwang;Kim, Young-Bok;Yoon, Jung-In;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.118-123
    • /
    • 2012
  • Water balance has a significant impact on the overall fuel cell performance. Maintenance of proper water management should provide an adequate membrane hydration and avoidance of water flooding in the catalyst layer and gas diffusion layer. Considering the important of advanced water management in PEM fuel cell, this study proposes a simple one dimensional water transportation model of PEM fuel cell for use in a dynamic condition. The model has been created by assumption that the output is the water liquid saturation difference. The liquid saturation change is the total difference between the additional water and the removal water on the system. The water addition is obtained from fuel cell reaction and the electro osmotic drag. The water removal is obtained from capillary transport and evaporation process. The result shows that the capillary water transport of low temperature fuel cell is high because the evaporation rate is low.

Disposable Microchip-Based Electrochemical Detector Using Polydimethylsiloxane Channel and Indium Tin Oxide Electrode (Polydimethylsiloxane 채널과 indium tin oxide 전극을 이용한 일회용 전기화학적 검출 시스템)

  • Yi In-Je;Kang Chi-Jung;Kim Yong-Sang;Kim Ju-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.5
    • /
    • pp.227-231
    • /
    • 2005
  • We have developed a microsystem with a capillary electrophoresis (CE) and an electrochemical detector (ECD). The microfabricated CE-ECD systems are adequate for a disposable type and the characteristics are optimized for an application to the electrochemical detection. The system was realized with polydimethylsiloxane (PDMS)-glass chip and indium tin oxide electrode. The injection and separation channels (80 um wide$\ast$40 um deep) were produced by moulding a PDMS against a microfabricated master with relatively simple and inexpensive methods. A CE-ECD systems were fabricated on the same substrate with the same fabrication procedure. The surface of PDMS layer and ITO-coated glass layer was treated with UV-Ozone to improve bonding strength and to enhance the effect of electroosmotic flow. For comparing the performance of the ITO electrodes with the gold electrodes, gold electrode microchip was fabricated with the same dimension. The running buffer was prepared by 10 mM 2-(N-morpholino)ethanesulfonic acid (MES) titrated to PH 6.5 using 0.1 N NaOH. We measured olectropherograms for the testing analytes consisted of catechol and dopamine with the different concentrations of 1 mM and 0.1 mM, respectively. The measured current peaks of dopamine and catechol are proportional to their concentrations. For comparing the performance of the ITO electrodes with the gold electrodes, electropherograms was measured for CE-ECD device with gold electrodes under the same conditions. Except for the base current level, the performances including sensitivity, stability, and resolution of CE-ECD microchip with ITO electrode are almost the same compared with gold electrode CE-ECD device. The disposable CE/ECD system showed similar results with the previously reported expensive system in the limit of detection and peak skew. When we are using disposable microchips, it is possible to avoid polishing electrode and reconditioning.

The Value of Comparison with Four Dimension Time Resolved Imaging of Contrast Kinetics(TRICKS) MRA by Time of Flight(TOF) MRA (4차원 TRICKS 자기공명혈관조영술과 기존 TOF 자기공명혈관조영술의 비교 및 유용성)

  • Bae, Sung-Jin;Lim, Cheong-Hwan;Park, Byung-Rae;Shin, Woon-Jae;Kim, Jung-Sam
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.3
    • /
    • pp.215-221
    • /
    • 2010
  • To assess the clinical value of time resolved imaging of contrast kinetics(TRICKS) MRA by comparison with conventional time of flight(TOF) MR angiography. Both TOF-MRA and TRICKS-MRA were performed in 17 patients with cerebrovascular disease and in 6 patients with brain tumor. Among 17 cerebraovascular patients, digital subtraction angiography(DSA) data were also obtained in 11 patients. TOF-MRA showed good spatial resolution but short in temporal resolution. Although TRICKS-MRA showed somewhat low spatial resolution, it showed superior temporal resolution by distinguishing vessel and tumor in all patients. Also, from the analysis of vessel-tumor relationship, TRICKS-MRA showed better performance than TOF-MRA. TRICKS-MRA makes it possible to image arterial, capillary and venous phase sequentially with very speedy manner and therefore, the clinical use of this method is highly suggestive for future use.