• 제목/요약/키워드: CT-Dose Phantom

검색결과 277건 처리시간 0.026초

노이즈 레벨 및 유사도 평가 기반 저선량 조건의 전산화 단층 검사 영상에서의 비지역적 평균 알고리즘의 최적화 (Optimization of Non-Local Means Algorithm in Low-Dose Computed Tomographic Image Based on Noise Level and Similarity Evaluations)

  • 정하선;김이준;박수빈;박수연;오윤지;이우석;서강현;이영진
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권1호
    • /
    • pp.39-48
    • /
    • 2024
  • In this study, we optimized the FNLM algorithm through a simulation study and applied it to a phantom scanned by low-dose CT to evaluate whether the FNLM algorithm can be used to obtain improved image quality images. We optimized the FNLM algorithm with MASH phantom and FASH phantom, which the algorithm was applied with MATLAB, increasing the smoothing factor from 0.01 to 0.05 with increments of 0.001 and measuring COV, RMSE, and PSNR values of the phantoms. For both phantom, COV and RMSE decreased, and PSNR increased as the smoothing factor increased. Based on the above results, we optimized a smoothing factor value of 0.043 for the FNLM algorithm. Then we applied the optimized FNLM algorithm to low dose lung CT and lung CT under normal conditions. In both images, the COV decreased by 55.33 times and 5.08 times respectively, and we confirmed that the quality of the image of low dose CT applying the optimized FNLM algorithm was 5.08 times better than the image of lung CT under normal conditions. In conclusion, we found that the smoothing factor of 0.043 among the factors of the FNLM algorithm showed the best results and validated the performance by reducing the noise in the low-quality CT images due to low dose with the optimized FNLM algorithm.

Feasibility of Improving the Accuracy of Dose Calculation Using Hybrid Computed Tomography Images: A Phantom Study

  • Jeon, Hosang;Kim, Dong Woon;Joo, Ji Hyeon;Ki, Yongkan;Kim, Wontaek;Park, Dahl;Nam, Jiho;Kim, Dong Hyeon
    • 한국의학물리학회지:의학물리
    • /
    • 제32권1호
    • /
    • pp.18-24
    • /
    • 2021
  • Purpose: Kilovoltage computed tomography (kV-CT) is essential for radiation treatment planning. However, kV-CT images are significantly distorted by artifacts when a metallic prosthesis is present in the patient's body. Thus, the accuracies of target delineation and treatment dose calculation are inevitably lowered. We evaluated the accuracy of the calculated doses using an image restoration method with hybrid CT, which was introduced in our previous study. Methods: A cylindrical phantom containing four metals, namely, silver, copper, tin, and tungsten, was scanned using kV-CT and megavoltage CT to produce hybrid CT images. We created six verification plans for three head and neck patients on kV-CT and hybrid CT images of the phantom and calculated their doses. The actual doses were measured with film patches during beam delivery using tomotherapy. We used the gamma evaluation method to compare dose distribution between kV-CT and hybrid CT with three gamma criteria, namely, 3%/3 mm, 2%/2 mm, and 1%/1 mm. Results: The gamma pass rates decreased as the gamma criteria were strengthened, and the pass rate of hybrid CT was higher than that of kV-CT in all cases. When the 1%/1 mm criterion was used, the difference in gamma pass rates between them was up to 13%p. Conclusions: According to our findings, we expect that the use of hybrid CT can be a suitable approach to avoid the effect of severe metal artifacts on the accuracy of dose calculation and contouring.

두부 CT 검사 시 검사 모드에 따른 화질 및 선량평가 (Image Quality and Dose Assessment According to Examination Mode during Head CT Examination)

  • 강헌효;최우전;김동현
    • 한국방사선학회논문지
    • /
    • 제15권4호
    • /
    • pp.437-444
    • /
    • 2021
  • 두경부 CT 검사시 팬텀을 이용하여 Helical mode, High Pitch Mode, Volume Axial Mode 사용하여 획득한 CT 영상으로부터 환자의 피폭선량과 각 영상의 화질을 비교 및 분석하여 Volume Axial Mode의 유용성을 평가해보고자 한다. 두경부 CT 검사 시 각 mode에 따른 70 kVp, 80 kVp, 100 kVp 관전압에 따라 검사를 시행하였다. 사용 장비로는 GE사의 Revolution(GE Healthcare, Wisconsin USA) 모델과 iMED X-ray Phantom을 이용하였다. 검사 Mode에따른 kVp별로 얻어진 영상을 이용하여 팬텀의 피폭선량을 비교하였으며, 각 영상에 ROI를 설정해 신호대 잡음비와 대조도대 잡음비를 산출하여 영상의 화질을 비교하였다. Volume Axial Mode를 사용하여 검사하였을 때 팬텀의 피폭선량이 Helical에 비해 17.12% 낮게, High Pitch에 비해 5.35% 낮게 측정되었고, 신호대 잡음비와 대조도대 잡음비가 향상되었다. Volume Axial Mode는 고속 회전 스캐너를 이용하여 테이블의 이동이 없이 조사시간을 줄이고, High Pitch Mode와 Helical Mode를 사용했을 때 보다 팬텀의 0.28초의 단시간에 영상을 획득하여 피폭선량이 감소하고 영상의 화질 또한 향상되는 유용한 검사라 할 수 있다. 또, 몸이 불편한 환자의 촬영이나 긴급환자의 CT 촬영에 있어서 Volume Axial Mode의 빠른 검사시간은 최대의 장점이라고 볼 수 있다.

두개골-선조체 팬텀을 이용한 선량 저감화 방안 연구 (The Study of Radiation Exposure Reduction by Developing Corpus Striatum Phantom)

  • 김정수;박찬록
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.595-603
    • /
    • 2017
  • 본 연구는 파킨슨질환의 진행 정도를 평가할 수 있는 선조체를 모사한 brain 팬텀을 직접 제작하여, PET-CT검사 시 최적의 영상의 질을 유지하면서 CT 스캔에 의한 brain 선량 저감을 위한 가능성을 평가하였다. 팬텀의 hot sphere와 background (radi oacti vi ty rati o 3:1)에 $^{18}F$ FP-CIT를 주입하고, 관전압(100, 120 kVp)과 관전류(80, 140, 200 mAs)의 조건을 변화시키며 CT 스캔을 실험하였다(기준조건; 120 kVp, 140 mAs). 각 조건에 따라 예상유효선량을 conversion factor를 적용해 계산하였고, SNR과 CRChot의 영상평가 인자를 설정하여 영상의 질을 평가하였다. 실험결과 CT 촬영 기준조건 이하에서의 예상유효선량은 최소 10%에서 최고 60% 정도 감소하였고, 기준조건 이상에서의 예상유효선량은 40% 증가하였다. 또한 PET 영상의 SNR과 CRChot의 유의한 차이는 없었으므로, 관전압과 관전류의 감소에 따라 brain 선량이 감소함을 확인하였다. 이와 동시에 스캔 조건의 변화에도 불구하고 SNR과 CRChot 측면에서의 영상의 질에는 유의한 변화가 없었다. 이러한 사실은 낮은 선량 조건으로도 기존의 선량 조건으로 획득한 영상의 질 수준을 얻을 수 있었으므로, 추후 brain PET-CT 스캔의 선량감소와 동시에 영상의 질 향상에 관한 연구의 기초자료로 활용이 가능할 것으로 사료된다.

유리선량계를 이용한 관전류자동조절기법과 고정관전류기법에서 저선량 및 고해상 흉부CT의 노이즈 및 선량 비교 (Comparison of Noise and Doses of Low Dose and High Resolution Chest CT for Automatic Tube Current Modulation and Fixed Tube Current Technique using Glass Dosimetry)

  • 박태석;한준희;조승연;이은임;조규원;권대철
    • 방사선산업학회지
    • /
    • 제11권3호
    • /
    • pp.131-137
    • /
    • 2017
  • To compare the radiation dose and image noise of low dose computed tomography (CT) and high resolution CT using the fixed tube current technique and automatic tube current modulation (CARE Dose 4D). Chest CT and human anthropomorphic phantom were used the RPL (radiophotoluminescence) dosimeters. For image evaluation, standard deviation of mean CT attenuation coefficient and CT attenuation coefficient was measured using ROI analysis function. The effective dose was calculated using CTDIvol and DLP. CARE Dose 4D was reduced by 74.7% and HRCT by 64.4% compared to the fixed tube current technique in low dose CT of chest phantom. In CTDIvol and DLP, the dose of CARE Dose 4D was reduced by fixed tube current technique. For effective dose, CARE Dose 4D was reduced by 47% and HRCT by 46.9% compared to the fixed tube current method, and the dose of CARE Dose 4D was significantly different (p<.05). Noise in the image was higher than that in the fixed tube current technique. Noise difference in the image of CARE Dose 4D in low dose CT was significant (p<.05). The low radiation dose and the noise difference of the CARE Dose 4D were compared with the fixed tube current technique in low dose CT and HRCT using chest phantom. The radiation doses using CARE Dose 4D were in accordance with the national and international dose standards. CARE Dose 4D should be applied to low dose CT and HRCT for clinical examination.

Geant4-DICOM Interface-based Monte Carlo Simulation to Assess Dose Distributions inside the Human Body during X-Ray Irradiation

  • Kim, Sang-Tae
    • International Journal of Contents
    • /
    • 제8권2호
    • /
    • pp.52-59
    • /
    • 2012
  • This study uses digital imaging and communications in medicine (DICOM) files acquired after CT scan to obtain the absorbed dose distribution inside the body by using the patient's actual anatomical data; uses geometry and tracking (Geant)4 as a way to obtain the accurate absorbed dose distribution inside the body. This method is easier to establish the radioprotection plan through estimating the absorbed dose distribution inside the body compared to the evaluation of absorbed dose using thermo-luminescence dosimeter (TLD) with inferior reliability and accuracy because many variables act on result values with respect to the evaluation of the patient's absorbed dose distribution in diagnostic imaging and the evaluation of absorbed dose using phantom; can contribute to improving reliability accuracy and reproducibility; it makes significance in that it can implement the actual patient's absorbed dose distribution, not just mere estimation using mathematical phantom or humanoid phantom. When comparing the absorbed dose in polymethly methacrylate (PMMA) phantom measured in metal oxide semiconductor field effect transistor (MOSFET) dosimeter for verification of Geant4 and the result of Geant4 simulation, there was $0.46{\pm}4.69%$ ($15{\times}15cm^2$), and $-0.75{\pm}5.19%$ ($20{\times}20cm^2$) difference according to the depth. This study, through the simulation by means of Geant4, suggests a new way to calculate the actual dose of radiation exposure of patients through DICOM interface.

3차원 안모분석을 위한 저선량 Multi-detector CT 영상의 유효선량 및 화질 평가 (Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning)

  • 정기정;한원정;김은경
    • Imaging Science in Dentistry
    • /
    • 제40권1호
    • /
    • pp.15-23
    • /
    • 2010
  • Purpose : This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. Materials and Methods : 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Results : Effective doses in ${\mu}Sv$ ($E_{2007}$) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. Conclusion : From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

CT 기종에 따른 CT 수의 변화가 선량계산에 미치는 영향 (The Effect of the CT Number for Each CT on Dose Calculation)

  • 조광환;이석;조삼주;임상욱;허현도;민철기;조병철;김용호;최두호;김은석;권수일
    • 한국의학물리학회지:의학물리
    • /
    • 제16권4호
    • /
    • pp.161-165
    • /
    • 2005
  • CT 기종에 따라서 전자밀도에 대응하는 CT 수의 변화와 치료계획 시 선량계산에 미치는 영향을 분석하였다. 5종의 CT를 이용하여 전자밀도 교정 팬톰의 영상을 얻어 기종에 따른 CT 수의 변화를 알아보았다. 조직등가물질의 밀도에서 CT 수는 ${\pm}2\%$ 내의 차이를 보였으나 밀도가 큰 영역에서는 최대 $9.5\%$의 차이를 나타냈다. CT 수의 변화가 치료계획의 선량계산에 미치는 영향을 알아보기 위하여 환자의 흉부 영상을 이용하여 장기별로 선량의 차이를 분석한 결과 최대 $0.48\%$로 거의 차이를 보이지 않았다. 밀도가 큰 물질이 인체 내에 삽입되어 있을 경우를 가정하여 물팬톰에 CT 수가 2,000인 고밀도 물질을 삽입한 팬톰 영상을 치료계획장치에 그려 넣었다. 고밀도 물질 아래 20 cm 깊이에서 선량 계산을 비교한 결과 $2.1\%$의 차이를 보였다. 치료계획 단계에서 선량 불확도를 최소화하기 위해서는 사용되는 CT 기종에 따른 CT수와 전자밀도의 정확한 환산이 필요하며, 특히 한 기관에서 여러 종류의 CT를 이용하는 경우 각 CT 별로 전자밀도에 대응하는 CT 수를 입력하고 서로 구별하여 사용하여야한다. 또한 CT수의 재현성을 확인하기 위해 주기적인 점검이 요구된다.

  • PDF

방사선치료 시 Metal artifact reduction Algorithm의 임상적용 유용성평가 (A Study on Usefulness of Clinical Application of Metal Artifact Reduction Algorithm in Radiotherapy)

  • 박자람;김민수;김정미;정현숙;이충환;백금문
    • 대한방사선치료학회지
    • /
    • 제29권2호
    • /
    • pp.9-17
    • /
    • 2017
  • 목 적: 방사선치료에서 CT number에 의해 나타나는 조직의 묘사 및 전자밀도는 CT(Computed Tomography)기반의 전산화치료계획 정확성을 보장하는데 중요한 역할을 한다. 하지만 체내의 금속 이식물은 CT number의 정확성을 감소시킬 뿐 아니라 조직 묘사에 대한 불확실성을 나타내기 때문에 임상에서는 metal artifact를 감소시킬 수 있는 알고리즘이 개발되었다. 이에 본 연구에서는 본원에서 사용하고 있는 GE사의 SMART MAR의 CT number 정확도를 평가하고 방사선치료에서의 유용성에 대해 평가하고자 한다. 대상 및 방법: 영상평가를 위해 CIRS ED phantom을 이용하여 6개 조직의 rod를 삽입하여 동일한 체적의 ROI를 형성 후 original 영상을 획득하고 의료용 티타늄 rod를 삽입하여 non-SMART MAR 영상과 SMART MAR영상을 획득하여 CT number와 SD값을 비교하였다. Metal artifact로 인해 CT number 변화에 따른 선량변화 확인을 위해 전산화계획시스템 Epclipse를 사용하여 CIRS ED phantom CT 영상에 PTV를 형성하여 original 영상을 획득하고 편측 티타늄 삽입, 양측 티타늄 삽입 영상을 획득하여 non-SMART MAR와 SMART MAR영상에 동일한 치료계획을 수립하여 PTV가 받는 평균처방선량, HI(Homogeneity Index), CI(Conformity Index)를 비교, 분석하였다. 흡수선량 측정은 원통형 아크릴 팬텀과 0.125 cc ionchamber, electrometer를 이용하여 선량변환상수(cCy/nC)를 계산하고 CIRS phantom을 이용하여 편측, 양측 티타늄 rod를 삽입한 영상으로 non-SMART MAR와 SMART MAR 영상을 획득하여 동일한 지점에서의 흡수선량을 측정하여 전산화치료계획상의 point dose와 비교하였다. 결 과: 영상평가 결과 CT number는 non-SMART MAR영상보다 SMART MAR 영상이 original영상에 더 유사한 값이 나왔고 SD값은 SMART MAR영상에서 더 감소되었다. 선량평가 결과 평균처방선량과 HI 및 CI 값은 SMART MAR 영상보다 non-SMART MAR 영상이 original 영상에 더 근접한 결과가 나왔지만 통계적으로 유의하지 않았다. 흡수선량 측정결과 치료계획상의 point dose와 실제 흡수선량과의 차이가 non-SMART MAR의 영상에서는 각각 2.69, 3.63 %의 차이가 있었지만 SMART MAR영상에서는 0.56, 0.68 %로 감소하였다. 결 론: 금속 이식물을 삽입한 환자의 CT 영상에 SMART MAR를 적용했을 때 CT number 정확성 상승 및 SD 감소로 영상의 질이 향상되므로 종양과 정상조직의 윤곽도 생성 및 선량계산 시 유용할 것으로 사료된다.

  • PDF

골반 방사선 치료에서 산란이 kV-Conebeam CT 영상 기반의 선량계산에 미치는 영향에 대한 연구 (Study of Scatter Influence of kV-Conebeam CT Based Calculation for Pelvic Radiotherapy)

  • 윤경준;곽정원;조병철;김영석;이상욱;안승도;남상희
    • 한국의학물리학회지:의학물리
    • /
    • 제25권1호
    • /
    • pp.37-45
    • /
    • 2014
  • ConeBeam Computed Tomography (CBCT) 영상을 기반으로 한 선량계산에서는 Fanbeam Computed Tomography (FBCT)와 비교하여 산란에 의한 영향이 크고 그 양상이 다양하게 나타나 오차의 주요한 요인으로 작용하는 것으로 알려져 있다. 본 논문에서는 골반 방사선 치료에서 산란이 CBCT 기반으로 한 선량계산에 미치는 영향을 평가하여 오차를 최소화 할 수 있는 조건에 대하여 연구하였다. 다양한 산란조건에서의 CBCT 영상 취득을 위하여 전자밀도 교정용 팬텀에 크기가 각기 다른 산란물질을 추가하여 "산란부족", "산란과다", 그리고 "산란충분"의 3가지 조건을 정하였다. 산란조건에서 취득된 CBCT 영상에서 팬텀 중심부와 주변부의 위치에 따른 CT number값의 차이와 분포를 분석하여 균질도를 평가하였으며 FBCT 영상 기반의 선량 분포를 기준으로 하여 다양한 산란조건에서의 전자밀도 교정관계를 적용하였을 때 팬텀 및 전립선암 환자 5명의 CBCT 영상에서 계산된 선량분포의 감마합격률 및 상대적 오차를 구하였다. 팬텀 CBCT 영상에 대한 CT number들의 히스토그램에서의 분포에서 물 등가 물질에 해당하는 피크의 폭(FWHM)은 산란부족(685 HU)이나 산란과다(264 HU)보다 산란충분(146 HU)의 조건에서 가장 작게 나타나 균질도가 제일 좋은 것으로 평가되었고 팬텀의 중심부와 주변부에서 동일 성분에 대한 CT number의 차이 역시 같은 결과를 나타내었다. 또한 팬텀의 CBCT 영상을 취득할 때와 동일한 산란조건에서의 교정조건을 적용한 경우 선량계산이 가장 정확하였으며 산란충분의 교정곡선 조건을 적용하였을 때 5명의 전립선암환자(평균 등가지름 27.2 cm)의 CBCT 영상 기반의 선량분포는 FBCT의 경우와 대비하여 1%/3 mm의 감마지표에서 감마합격률 98% 이상을 나타내었다. 이때 FBCT 선량에 대한 CBCT 선량오차는 처방선량 대비 2% 이하(평균 0.2%, -1.3%~1.6%)로 평가되었다. CBCT 골반 촬영을 할 때 일반적인 성인 골반의 원통 등가지름(ECD, Equivalent Cylindrical Diameter)의 산란조건에서 동일 성분에 대한 HU 값이 가장 균질하게 나타나 골반 촬영모드가 최적화되었음을 확인하였으며 일반적인 골반부위와 ECD가 유사한 산란조건, 즉 산란충분조건에서 취득된 전자밀도 교정관계를 적용하여 골반 CBCT 기반에서 선량을 계산하였을 때 최적의 선량 정확성을 확보할 수 있었다.