• 제목/요약/키워드: CT 촬영

검색결과 1,593건 처리시간 0.025초

영상재구성 전산화 단층촬영에서 촬영조건의 변화가 하악골 술전 임플란트 부위 평가에 미치는 영향 (Effect of Variable Scanning Protocols on the Pre-implant Site Evaluation of the Mandible in Reformatted Computed Tomography)

  • 김기덕;박창서
    • 치과방사선
    • /
    • 제29권1호
    • /
    • pp.21-32
    • /
    • 1999
  • Purpose: To evaluate the effect of variable scanning protocols of computed tomography for evaluation of pre-implant site of the mandible through the comparison of the reformatted cross-sectional images of helical CT scans obtained with various imaging parameters versus those of conventional CT scans. Materials and Methods: A dry mandible was imaged using conventional nonoverlapped CT scans with 1 mm slice thickness and helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5. 2.0, 2.5 and 3.0. All helical images were reconstructed at reconstruction interval of 1 mm. DentaScan reformatted images were obtained to allow standardized visualization of cross-sectional images of the mandible. The reformatted images were reviewed and measured separately by 4 dental radiologists. The image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal were evaluated and the distance between anatomic structures were measured by 4 dental radiologists. Results: On image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal and in horizontal measurement. there was no statistically significant difference among conventional and helical scans with pitches of 1.0. 1.5 and 2.0. In vertical measurement. there was no statistically significant difference among the conventional and all imaging parameters of helical CT scans with pitches of 1.0, 1.5, 2.0, 2.5 and 3.0. Conclusion: The images of helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5 and 2.0 are as good as those of conventional CT scans with 1 mm slice thickness for evaluation of predental implant site of the mandible. Considering the radiation dose and patient comfort, helical CT scans with 1 mm slice thickness and pitch of 2.0 is recommended for evaluation of pre-implant site of the mandible.

  • PDF

소아치과 영역에서 전산화 단층촬영술의 임상적 활용에 대한 증례보고 (A CASE STUDY ON CLINICAL APPLICATION OF COMPUTED TOMOGRAPHY IN PEDIATRIC DENTISTRY)

  • 이윤석;장기택;이상훈
    • 대한소아치과학회지
    • /
    • 제25권3호
    • /
    • pp.493-498
    • /
    • 1998
  • 1. CT에 의한 매복치의 위치결정은 적절한 치료계획의 수립을 가능하게 하여 시술시간의 단축과 인접치, 인접구조물의 손상을 줄여 시술후의 부작용을 줄일 수 있었다. 2. 매복된 영구치의 견인시 CR를 활용한 결과 개창부위의 정확한 위치결정과 예후에 대한 예측이 가능하였다. 3. 평면방사선사진의 판독후 악골내 병소가 의심되어 CT를 활용한 결과 병소의 확진이 가능하였다. 4. 소아의 CT촬영은 평면 방사선 촬영에 비해 증가된 방사선 피폭량, 높은 수가 때문에 적절한 증례의 선택이 중요하다.

  • PDF

폐실질 내에 위치한 소결질 및 간유리 병변에서 흉부컴퓨터단층촬영 유도하에 Hook Wire를 이용한 위치 선정 후 시행한 흉강경 폐절제술의 유용성 (Computed Tomography-guided Localization with a Hook-wire Followed by Video-assisted Thoracic Surgery for Small Intrapulmonary and Ground Glass Opacity Lesions)

  • 강필제;김용희;박승일;김동관;송재우;도경현
    • Journal of Chest Surgery
    • /
    • 제42권5호
    • /
    • pp.624-629
    • /
    • 2009
  • 배경: 패실질 내에 위치한 소결절 및 간유리 병변은 깊이나 크기에 따라서 조직학적 진단이 기존의 방법으로는 어려운 경우가 있다. 이에 연구자는 흉부 전산화 단층 촬영 소견에서 흉강경을 통한 육안 확인이 어려울 것으로 예상되거나 경피 세침 흡인생검술이 부적절하였던 폐실질 내에 위치한 소결절 및 간유리 병변에서 수슬 전에 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정(CT-guided localization with hook wire)을 시행한 후 흉강경 폐절제술을 시행하였고, 그 결과를 보고 하고자 한다. 대상 및 방법: 2005년 8월부터 2008년 3월까지 흉부 전산화 단층 촬영 소견에서 폐실질내에 위치한 소결절 및 간유리 병변을 보인 18명 환자(남자 13명, 나이 중앙값 56세)를 대상으로 수술 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정을 시행한 후 흉강경 폐절제술을 시행하였다. Hook wire 위치의 정확도, 개흉술 전환 정도, 수술 시간, 수술 후 합병증, 폐병변의 조직학적 진단의 정확성 등을 분석하였다. 결과: 18명의 환자가 18개의 폐실질 내에 위치한 소결절 및 간유리 병변에 대해 흉강경 폐절제술을 받았다. 수술 전 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정은 전례에서 성공적으로 시행되었으나, 흉강경 소견에서 wire가 이탈된 경우가 1예 있었다. 수술 전 CT에서 폐 병변 크기의 중앙값은 8 mm ($3{\sim}15\;mm$)였고, 내장 흉막에서 폐병변까지 깊이의 중앙값은 5.5 mm ($1{\sim}30\;mm$)였다. 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정 후 마취 시작까지 걸린 대기 시간의 중앙값은 34.5분($10{\sim}226$분)이었다. 폐병변에 대한 흉강경 폐절제술의 수술 시간은 43.5분($26{\sim}83$분)이었다. 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정과 관련된 합병증으로 2예에서 기흉이 발생하였으나, 임상적으로 유의한 증상은 없었다. 폐병변의 절제 단면은 모든 경우에서 이상 소견이 없었으며, 조직학적 진단은 원발성 폐암 8예, 전이성 폐암 3예, 비특이적 염증성 소견 3예, 폐내 림프절 2예, 기타 2예 등이었으며 조직학적 진단을 하지 못한 경우는 얼었다. 결론: 폐실질 내에 위치한 소결절 및 간유리 병변의 조직학적 진단을 위하여 시행한 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정 후 시행한 흉강경 폐절제술은, 낮은 합병증 발생률, 짧은 수술 시간 및 정확한 조직학적 진단율을 보였다. 따라서 경피 세침 흡인생검술로 정확한 진단이 어렵거나 흉강경을 통한 육안 확인이 불가능한 폐실질 내의 소결절 및 간유리 병변을 조직학적으로 진단하기 위하여 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용하여 위치를 선정한 후 흉강경 폐절제술을 시행하는 것은 매우 효과적이라고 생각한다.

복부 전산화단층촬영 결과 진단된 급성 외상성 골반골 골절에서 추가적인 3차원 재구성 골반 전산화단층촬영이 필요한가? (The Need for an Additional Pelvic CT in Cases of Acute Osseous Pelvic Injury that Has Already Been Diagnosed by Abdominal CT.)

  • 김병권;신동혁;한상국;최필조;이영한;박하영;배수호;송형곤
    • Journal of Trauma and Injury
    • /
    • 제22권2호
    • /
    • pp.206-211
    • /
    • 2009
  • Purpose: Abdominal CT (computed tomography) is a principal diagnostic imaging modality for torso trauma at the Emergency Department (ED). When acute osseous pelvic injuries are detected by abdominal CT, additional three-dimensional (3D) reconstruction pelvic CT is often performed. We compared abdominal CT with pelvic CT to provide information about acute osseous pelvic injuries. Methods: A retrospective investigation of patients'electronic medical records during the five year period between January 1, 2004 and December 31, 2008 among Korean soldiers who underwent pelvic CT after abdominal CT at the ED was conducted. Axial images of abdominal CT were compared with axial images and 3D reconstruction images of pelvic CT. Results: Sixteen patients underwent subsequent pelvic CT after abdominal CT. Axial images of abdominal CT showed the same results in terms of fracture detection and classification when compared to axial images and 3D reconstruction images of pelvic CT. Pelvic CT (including 3D reconstruction images) followed by abdominal CT neither detected additional fracture nor changed the fracture type. Conclusion: This study has failed to show any superiority of pelvic CT (including 3D reconstruction images) over abdominal CT in detecting acute osseous pelvic injury. When 3D information is deemed be mandatory, 3D reconstructions of abdominal CT can be requested rather than obtaining an additional pelvic CT for 3D reconstruction.

Breast PET CT 영상 재구성 변화에 따른 대조도 대 잡음비와 신호 대 잡음비의 비교평가 (Evaluation and Comparison of Contrast to Noise Ratio and Signal to Noise Ratio According to Change of Reconstruction on Breast PET/CT)

  • 이재영;이을규;김기원;정회원;유광열;박훈희;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.79-85
    • /
    • 2017
  • 본 연구는 양전자 컴퓨터단층촬영(Positron Emission Computed Tomography; PET-CT) 유방암 영상에서 질환관심영역(Region of Interest; ROI)의 대조도 대 잡음비(Contrast to Noise Ratio; CNR)와 신호 대 잡음비(Signal to Noise Ratio; SNR)를 재구성 기법별로 측정 평가하여 통계적 분석을 하고자 하였다. 연구대상은 서울소재 대학병원에서 유방 양전자 컴퓨터단층촬영(Breast PET-CT)을 검사한 환자 100명이다. 측정방법은 ImageJ 프로그램을 사용하여 표본의 인구사회학적 특성, 영상 재구성 기법별 유방암의 SNR과 CNR의 평균값, 95% 신뢰구간 값, SNR과 CNR의 평균차이 값 등을 분석하였다. SPSS Statistics21 통계프로그램으로 ANOVA 분석을 하였으며 p<0.05에서 유의한 것으로 판단하였다. 영상 재구성 기법별 분석결과는 CNR과 SNR 모두 TrueX_TOF, Iterative, Iterative-TOF, FBP-TOF 순으로 높은 값을 나타냈다(p<0.05). CNR과 SNR수치로 영상 재구성 기법의 특징을 조합하여 PET/CT 검사의 정확성과 편의성을 제공할 것이라 사료된다.

흉부 CT촬영에서 저선량 프로토콜의 선량과 화질: 표준선량 프로토콜과 비교 (Radiation Dose and Image Quality of Low-dose Protocol in Chest CT: Comparison of Standard-dose Protocol)

  • 이원정;안봉선;박영선
    • Journal of Radiation Protection and Research
    • /
    • 제37권2호
    • /
    • pp.84-89
    • /
    • 2012
  • 임상에서 사용하고 있는 흉부 CT촬영의 저선량 프로토콜과 표준선량 프로토콜 간의 선량과 화질을 비교 분석하였다. 흉부 저선량 프로토콜(120 kVp, 30 mAs)과 표준선량 프로토콜(120 kVp, 180 mAs)로 촬영($Brilliance^{TM}$ CT 16slice, PHILIPS)한 61명의 조영제를 사용하지 않은 영상에서 기관 분기부 위치의 종격동 영상을 본 연구를 위해 사용하였다. 상행대동맥과 가시아래근에서 CT number와 잡음을 측정하였고, Back-ground 잡음을 측정하여 신호대잡음비(signal-to-noise ratio. SNR)와 대조도잡음비(contrast-to-noise ratio, CNR)를 구하였다. 두부 아크릴 팬텀을 이용하여 선량을 측정하였고, 워터 팬텀으로 얻은 영상에서 CT number와 잡음을 측정하였다. 모든 측정은 3회 실시하여 평균값을 SPSS 프로그램(version 14.0)으로 분석하였고, 그래프는 시그마 플롯 프로그램(version10.0)을 사용하였다. 결과: 상행대동맥과 가시아래근에서 저선량 프로토콜 영상이 표준선량 프로토콜 영상 보다 유의하게 높은 잡음을 보였고, SNR과 CNR은 유의하게 낮았다. 두 영상에서 비만지수에 대한 잡음은 양의 관련성을 보였지만, SNR과 CNR은 음의 관련성을 보였다. 팬텀 결과에서 저선량 프로토콜의 선량이 표준선량 프로토콜 보다 유의하게 낮았지만(0.35 mGy vs. 1.95 mGy, p=0.008), 잡음은 저선량 프로토콜에서 유의하게 높았다(p=0.029). 저선량 프로토콜이 표준선량 프로토콜 보다 유의하게 낮은 선량을 보였지만, 화질 평가도 유의하게 낮은 결과를 보임으로서 임상에서 사용하는 저선량 프로토콜의 노출 선량은 화질을 고려하여 상향 조정할 필요가 있다.

3D Dental-CT를 이용한 상악 매복 과잉치의 진단 : 증례보고 (DIAGNOSIS AND EXTRACTION OF IMPACTED SUPERNUMERARY TEETH IN THE MAXILLA WITH 3D DENIAL-CT)

  • 김수경;양연미;백병주;김성희;김재곤
    • 대한소아치과학회지
    • /
    • 제33권1호
    • /
    • pp.91-98
    • /
    • 2006
  • 과잉치는 법랑기(enamel organ)가 치배형성을 지속하거나 과도한 세포증식을 함으로써 발생한다. 과잉치는 상악 전방부에서 종종 발견되며, 유치열기와 혼합치열기에서 다양한 문제를 야기한다. 과잉치는 형태에 따라서 보충치(supplemental tooth)와 흔적치 (rudimental tooth)로 나눌 수 있다. 보충치는 정상 절치와 크기 및 형태가 유사하나, 흔적치는 비정상적인 형태와 작은 크기를 갖고 있다. 보충치는 영구 측절치 부위에서 호발하며 정상 전치와 유사한 형태와 크기를 갖고 있으므로, 발치시 주의를 기울여야 한다. 본 3증례는 상악 전방부에 정상 전치 형태의 과잉치를 갖는 증례들이다. 모든 증례에서, 치근단 교합, 파노라마 방사선 사진 등의 기존 방사선 사진 촬영 외에 3 Dimensional Dental-Computed Tomography(3D Dental-CT)를 촬영하여 진단하였다. 기존 일반 방사선 사진들(conventional radiographs)과 3D Dental-CT를 비교시, 일반 방사선 사진들은 2차원적인 영상만을 제공하여 상의 해석에 있어서 술자의 주관이 개입되는 한계가 있다. 반면 3D Dental-CT는 과잉치의 정확한 위치와 형태에 대한 객관적 인 정보를 제공하며, 좀 더 보존적 인 수술을 시행하고, 수술 시간과 스트레스를 줄이는데 유용하다. 그러므로 일반 방사선 사진 촬영 후 과잉치의 위치가 불분명하고 인접 영구치의 손상이 의심되는 경우 3D Dental-CT를 이용한 진단이 고려된다.

  • PDF

CT 조영을 위한 금 코팅 리포솜의 제조 (Preparation of Gold Coated Liposomes for CT Contrast Medium)

  • 위태인;전예원;조영재;조성근;하정;이정원;조선행;한희동;신병철
    • 대한화학회지
    • /
    • 제57권5호
    • /
    • pp.634-639
    • /
    • 2013
  • 암이나 혈관질환을 진단하기 위하여 영상의학기기들의 사용이 증가되고 있다. 영상의학기기 중 컴퓨터단층촬영(CT)은 가장 널리 이용되는 방법의 하나로서, CT를 하기 위해서는 조영제를 투여하여야 한다. 따라서, 본 연구에서는 리포솜의 표면에 금 입자를 코팅함으로써 조영제로 개발하고자 하였다. 금 입자를 코팅하기 위하여, 양이온성 리포솜을 제조하였고, 양이온성 리포솜의 표면에 음이온을 띄는 $Au^-$가 정전기적으로 코팅이 되게 하였다. 금 코팅 리포솜(GCL)의 크기는 $154.8{\pm}9.2$ nm 이었고, 표면전하는 $27{\pm}3.2$ mV 이었다. 리포솜의 형태는 주사전자현미경과 투과전자현미경으로 확인하였다. 리포솜 표면의 금 코팅 효율은 18% 였으며, MTT 분석을 한 결과, 금 코팅 과정에 대한 세포독성은 없었다. 그리고, 제조된 금 입자 코팅 리포솜을 CT로 촬영했을 경우 우수한 조영 효과를 나타냈다. 따라서 본 연구에서 제조된 GCL은 CT 조영제로서 다양한 혈관질환에 적용이 가능할 것이다.