• Title/Summary/Keyword: CT (computed tomography)

Search Result 2,650, Processing Time 0.045 seconds

The reliability of the cephalogram generated from cone-beam CT (Cone-beam CT로부터 제작된 측모 두부계측방사선사진의 정확도 평가)

  • Kang, Ji-Young;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.391-399
    • /
    • 2007
  • Three-dimensional approaches for the diagnosis and analysis of the dentofacial area are becoming more popular in accordance with the development of cone-beam CT (CBCT). The purposes of this study were to evaluate the reliability of cephalometric measurements of lateral cephalograms generated from a CBCT image by making comparisons with the traditional digital lateral cephalogram, and to evaluate the possibility of the clinical application of CBCT generated cephalogram images. Methods: Twenty patients whose external auditory meatus could be identified in the CBCT image were selected, and both CBCT and digital cephalograms were taken. Differences between the measurements of both cephalograms were tested by paired t-test. Results: Among the 22 measurements used, only U1-FH, Mx6 to PTV, and maxillomandibular difference showed statistically significant differences between the CBCT generated cephalogram and the digital cephalogram. Conclusions: The results suggest that the CBCT generated cephalogram can be used for some cephalometric measurements not requiring porion, PTV, condylion as a landmark (SNA, SNB, U1 to SN, IMPA, interincisal angle, etc.).

Comparison Radiation Dose of Z-Axis Automatic Tube Current Modulation Technique with Fixed Tube Current Multi-Detector Row CT Scanning of Lower Extremity Venography (하지 정맥조영술 MDCT에서 고정 관전류 기법과 Z-축 자동 관전류 변동 제어에 의한 선량 비교)

  • Yoo, Beong-Gyu;Lee, Jong-Seok;Jang, Keun-Jo;Jeon, Sang-Hwan;Kim, Yong-Soo;Kweon, Dae-Cheol
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.123-133
    • /
    • 2007
  • Z-axis automatic tube current modulation technique automatically adjusts tube current based on size of body region scanned. The purpose of the current study was to compare noise, and radiation dose of multi-detector row CT (MDCT) of lower extremity performed with Z-axis modulation technique of automatic tube current modulation with manual selection fixed tube current. Fifty consecutive underwent MDCT venography of lower extremity with use of a MDCT scanner fixed tube current and Z-axis automatic tube current modulation technique (10, 11 and 12 HU noise index, $70{\sim}450\;mA$). Scanning parameters included 120 kVp, 0.5 second gantry rotation time, 1.35:1 beam pitch, and 1 mm reconstructed section thickness. For each subject, images obtained with Z-axis modulation were compared with previous images obtained with fixed tube current (200, 250, 300 mA) and with other parameters identical. Images were compared for noise at five levels: iliac, femoral, popliteal, tibial, and peroneal vein of lower extremity. Tube current and gantry rotation time used for acquisitions at these levels were recorded. All CT examinations of study and control groups were diagnostically acceptable, though objective noise was significantly more with Z-axis automatic tube current modulation. Compared with fixed tube current, 2-axis modulation resulted in reduction of CTDIvol (range, $-6.5%{\sim}-35.6%$) and DLP (range, $-0.2%{\sim}-20.2%$). Compared with manually selected fixed tube current, 2-axis automatic tube current modulation resulted in reduced radiation dose at MDCT of lower extremity venography.

CT Based 3-Dimensional Treatment Planning of Intracavitary Brachytherapy for Cancer of the Cervix : Comparison between Dose-Volume Histograms and ICRU Point Doses to the Rectum and Bladder

  • Hashim, Natasha;Jamalludin, Zulaikha;Ung, Ngie Min;Ho, Gwo Fuang;Malik, Rozita Abdul;Ee Phua, Vincent Chee
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5259-5264
    • /
    • 2014
  • Background: CT based brachytherapy allows 3-dimensional (3D) assessment of organs at risk (OAR) doses with dose volume histograms (DVHs). The purpose of this study was to compare computed tomography (CT) based volumetric calculations and International Commission on Radiation Units and Measurements (ICRU) reference-point estimates of radiation doses to the bladder and rectum in patients with carcinoma of the cervix treated with high-dose-rate (HDR) intracavitary brachytherapy (ICBT). Materials and Methods: Between March 2011 and May 2012, 20 patients were treated with 55 fractions of brachytherapy using tandem and ovoids and underwent post-implant CT scans. The external beam radiotherapy (EBRT) dose was 48.6Gy in 27 fractions. HDR brachytherapy was delivered to a dose of 21 Gy in three fractions. The ICRU bladder and rectum point doses along with 4 additional rectal points were recorded. The maximum dose ($D_{Max}$) to rectum was the highest recorded dose at one of these five points. Using the HDRplus 2.6 brachyhtherapy treatment planning system, the bladder and rectum were retrospectively contoured on the 55 CT datasets. The DVHs for rectum and bladder were calculated and the minimum doses to the highest irradiated 2cc area of rectum and bladder were recorded ($D_{2cc}$) for all individual fractions. The mean $D_{2cc}$ of rectum was compared to the means of ICRU rectal point and rectal $D_{Max}$ using the Student's t-test. The mean $D_{2cc}$ of bladder was compared with the mean ICRU bladder point using the same statistical test. The total dose, combining EBRT and HDR brachytherapy, were biologically normalized to the conventional 2 Gy/fraction using the linear-quadratic model. (${\alpha}/{\beta}$ value of 10 Gy for target, 3 Gy for organs at risk). Results: The total prescribed dose was $77.5Gy{\alpha}/{\beta}10$. The mean dose to the rectum was $4.58{\pm}1.22Gy$ for $D_{2cc}$, $3.76{\pm}0.65Gy$ at $D_{ICRU}$ and $4.75{\pm}1.01Gy$ at $D_{Max}$. The mean rectal $D_{2cc}$ dose differed significantly from the mean dose calculated at the ICRU reference point (p<0.005); the mean difference was 0.82 Gy (0.48-1.19Gy). The mean EQD2 was $68.52{\pm}7.24Gy_{{\alpha}/{\beta}3}$ for $D_{2cc}$, $61.71{\pm}2.77Gy_{{\alpha}/{\beta}3}$ at $D_{ICRU}$ and $69.24{\pm}6.02Gy_{{\alpha}/{\beta}3}$ at $D_{Max}$. The mean ratio of $D_{2cc}$ rectum to $D_{ICRU}$ rectum was 1.25 and the mean ratio of $D_{2cc}$ rectum to $D_{Max}$ rectum was 0.98 for all individual fractions. The mean dose to the bladder was $6.00{\pm}1.90Gy$ for $D_{2cc}$ and $5.10{\pm}2.03Gy$ at $D_{ICRU}$. However, the mean $D_{2cc}$ dose did not differ significantly from the mean dose calculated at the ICRU reference point (p=0.307); the mean difference was 0.90 Gy (0.49-1.25Gy). The mean EQD2 was $81.85{\pm}13.03Gy_{{\alpha}/{\beta}3}$ for $D_{2cc}$ and $74.11{\pm}19.39Gy_{{\alpha}/{\beta}3}$ at $D_{ICRU}$. The mean ratio of $D_{2cc}$ bladder to $D_{ICRU}$ bladder was 1.24. In the majority of applications, the maximum dose point was not the ICRU point. On average, the rectum received 77% and bladder received 92% of the prescribed dose. Conclusions: OARs doses assessed by DVH criteria were higher than ICRU point doses. Our data suggest that the estimated dose to the ICRU bladder point may be a reasonable surrogate for the $D_{2cc}$ and rectal $D_{Max}$ for $D_{2cc}$. However, the dose to the ICRU rectal point does not appear to be a reasonable surrogate for the $D_{2cc}$.

Automatic Fracture Detection in CT Scan Images of Rocks Using Modified Faster R-CNN Deep-Learning Algorithm with Rotated Bounding Box (회전 경계박스 기능의 변형 FASTER R-CNN 딥러닝 알고리즘을 이용한 암석 CT 영상 내 자동 균열 탐지)

  • Pham, Chuyen;Zhuang, Li;Yeom, Sun;Shin, Hyu-Soung
    • Tunnel and Underground Space
    • /
    • v.31 no.5
    • /
    • pp.374-384
    • /
    • 2021
  • In this study, we propose a new approach for automatic fracture detection in CT scan images of rock specimens. This approach is built on top of two-stage object detection deep learning algorithm called Faster R-CNN with a major modification of using rotated bounding box. The use of rotated bounding box plays a key role in the future work to overcome several inherent difficulties of fracture segmentation relating to the heterogeneity of uninterested background (i.e., minerals) and the variation in size and shape of fracture. Comparing to the commonly used bounding box (i.e., axis-align bounding box), rotated bounding box shows a greater adaptability to fit with the elongated shape of fracture, such that minimizing the ratio of background within the bounding box. Besides, an additional benefit of rotated bounding box is that it can provide relative information on the orientation and length of fracture without the further segmentation and measurement step. To validate the applicability of the proposed approach, we train and test our approach with a number of CT image sets of fractured granite specimens with highly heterogeneous background and other rocks such as sandstone and shale. The result demonstrates that our approach can lead to the encouraging results on fracture detection with the mean average precision (mAP) up to 0.89 and also outperform the conventional approach in terms of background-to-object ratio within the bounding box.

The Characteristics of Bronchioloalveolar Carcinoma Presenting with Solitary Pulmonary Nodule (고립성 폐결절로 나타난 기관지폐포암의 임상적 고찰)

  • Kim, Ho-Cheol;Cheon, Eun-Mee;Suh, Gee-Young;Chung, Man-Pyo;Kim, Ho-Joong;Kwon, O-Jung;Rhee, Chong-H.;Han, Yong-Chol;Lee, Kyoung-Soo;Han, Jung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.280-289
    • /
    • 1997
  • Background : Bronchioloalveolar carcinoma (BAC) has been reported to diveres spectrum of chinical presentations and radiologic patterns. The three representative radiologic patterns are followings ; 1) a solitary nodule or mass, 2) a localized consolidation, and 3) multicentric or diffuse disease. While, the localized consolidation and solitary nodular patterns has favorable prognosis, the multicentric of diffuse pattern has worse prognosis regardless of treatment. BAC presenting as a solitary pulmonary nodule is often misdiagnosed as other benign disease such as tuberculoma. Therefore it is very important to make proper diagnosis of BAC with solitary nodular pattern, since this pattern of BAC is usually curable with a surgical resection. Methods : We reviewed the clinical and radiologic features of patients with pathologically-proven BAC with solitary nodular pattern from January 1995 to September 1996 at Samsung Medical Center. Results : Total 11 patients were identified. 6 were men and 5 were women. Age ranged from 37 to 69. Median age was 60. Most patients with BAC with solitary nodular pattern were asymptomatic and were detected by incidental radiologic abnormality. The chest radiograph showed poorly defined opacity or nodule and computed tomography showed consolidation, ground glass appearance, internal bubble-like lucencies, air bronchogram, open bronchus sign, spiculated margin or pleural tag in most patients. The initial diagnosis on chest X-ray were pulmonary tuberculosis in 4 patients, benign nodule in 2 patients and malignant nodule in 5 patients. The FDG-positron emission tomogram was performed in eight patients. The FDG-PET revealed suggestive findings of malignancy in only 3 patients. The pathologic diagnosis was obtained by transbronchial lung biopsy in 1 patient, by CT guided percutaneous needle aspiration in 2 patients, and by lung biopsy via video-assited thoracocopy in 8 patients. Lobectomy was performed in all patients and postoperative pathologic staging were $T_1N_0N_0$ in 8 patients and $T_2N_0M_0$ in 3 patients. Conclusion : Patients of BAC presenting with solitary nodular pattern were most often asymptomatic and incidentally detected by radiologic abnormality. The chest X-ray showed poorly defined nodule or opacity and these findings were often regarded as benign lesion. If poorly nodule or opacity does not disappear on follow up chest X-ray, computed tomography should be performed. If consolidation, ground glass appearance, open bronchus sign, air bronchogram, internal bubble like lucency, pleural tag or spiculated margin are found on computed tomography, further diagnostic procedures, including open thoracotomy, should be performed to exclude the possiblity of BAC with solitary nodular pattern.

  • PDF

Usefulness of Ultrasonographic Examination by a Pediatrician in Children with Abdominal Pain (소아 복통에서 소아과 의사에 의한 초음파 검사의 유용성)

  • Park, Hyun-Seok;We, Ju-Hee;Park, Jae-Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.14 no.2
    • /
    • pp.141-147
    • /
    • 2011
  • Purpose: Ultrasonography (US) is widely used as a screening test in patients with abdominal pain (AP). We investigated the usefulness of US by a pediatrician in children with AP. Methods: We retrospectively analysed the medical records of children with AP who undertook US from December, 2008 to July, 2010. Results: A total of 628 patients (325 male, 303 female) were enrolled in this study. The mean age of patients was $8.08{\pm}4.61$ years. Duration of AP was acute in 427 and chronic in 201 patients. Localization of AP was diffuse (36.9%), periumbilical (24.4%), epigastric (21.0%), and right lower quadrant (8.1%). On the examination, there were no abnormal findings in 327 patients (52.1%). Abnormal ultrasonographic findings were mesenteric lymphadenitis (27.1%), intestinal mural thickening (10.0%), intussusception (3.0%), appendicitis (2.6%), choledochal cyst (1.6%), and pancreatitis (0.3%). We performed additional imaging studies such as computed tomography (CT) or magnetic resonance imaging (MRI) in 39 patients who showed obscure findings on the US. In 33 patients (84.6%), the same results were obtained from CT or MRI. Two cases of appendicitis, one case of pancreatitis and one case of Henoch-Sh$\ddot{o}$nlein purpura were diagnosed by the CT examination. However, there were two cases of appendicitis diagnosed by US thathad no evidence of appendicitis on the CT. Diagnostic accuracy of initial US in children with abdominal pain was 99.4%. Conclusion: US by a pediatrician as a screening test in children with AP provides a rapid and accurate diagnostic indication and has non-invasive and radiation-free advantages.

Effect of Noise on Density Differences of Tissue in Computed Tomography (컴퓨터 단층촬영의 조직간 밀도차이에 대한 노이즈 영향)

  • Yang, Won Seok;Son, Jung Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.403-407
    • /
    • 2018
  • Currently, the highest cancer death rate in Korea is lung cancer, which is a typical cancer that is difficult to detect early. Low-dose chest CT is being used for early detection, which has a greater lung cancer diagnosis rate of about three times than regular chest x-ray images. However, low-dose chest CT not only significantly reduces image resolution but also has a weak signal and is sensitive to noise. Also, air filled lungs are low-density organs and the presence of noise can significantly affect early diagnosis of cancer. This study used Visual C++ to set a circle inside a large circle with a density of 2.0, with a density of 1.0, which is the density of water, in which five small circle of mathematics have different densities. Gaussian noise was generated by 1%, 2%, 3%, and 4% respectively to determine the effect of noise on the mean value, the standard deviation value, and the relative noise ratio(SNR). In areas where the density difference between the large and small circles was greatest in the event of 1 % noise, the SNR in the area with the greatest variation in noise was 4.669, and in areas with the lowest density difference, the SNR was 1.183. In addition, the SNR values can be seen to be high if the same results are obtained for both positive and negative densities. Quality was also clearly visible when the density difference was large, and if the noise level was increased, the SNR was reduced to significantly affect the noise. Low-density organs or organs in areas of similar density to cancers, will have significant noise effects, and the effects of density differences on the probability of noise will affect diagnosis.

Clinical Features of Infectious Ileocecitis in Children (소아 감염성 회장맹장염의 임상적 고찰)

  • Lee, Tae-Ho;Hong, Yoo-Rha;Yeon, Gyu-Min;Lee, Jun-Woo;Park, Jae-Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.13 no.1
    • /
    • pp.30-35
    • /
    • 2010
  • Purpose: Infectious ileocecitis is an infection confined to the ileocecal area and one of the most common causes of pediatric abdominal pain. This study was performed to demonstrate the clinical features of infectious ileocecitis in children. Methods: The medical records and radiologic findings of 37 patients with ileocecitis diagnosed by ultrasonography and/or computed tomography, who were admitted to Pusan National University Hospital from January 2004 and July 2008, were reviewed retrospectively. Viral gastroenteritis and secondary ileocecitis were excluded. Results: The mean age of the patients was 4.8${\pm}$3.4 years. One-half of the patients were preschool children. The chief complaint was abdominal pain (75.7%), diarrhea (10.8%), and vomiting (8.1%). Accompanying symptoms were fever (56.8%), vomiting (21.6%), and diarrhea (16.2%). The mean duration of abdominal pain, fever, diarrhea, and vomiting was 3.8${\pm}$2.1, 3.0${\pm}$1.9, 3.4${\pm}$1.9, and 2.4${\pm}$2.3 days, respectively. The frequency of diarrhea and vomiting was 5.8${\pm}$2.2 and 4.0${\pm}$2.8 per day, respectively. Diagnosis was made by abdominal ultrasonography in 22 patients (59.5%), abdominal CT in 2 patients (5.4%), and both modalities in 13 patients (35.1%). Besides the radiologic finding of thickening of the bowel wall, mesenteric lymphadenitis (59.5%), ascites (5.4%), and both mesenteric lymphadenitis and ascites (16.2%) were revealed. The mean duration of illness was 7.5${\pm}$5.0 days. There were no specific laboratory findings, and culture studies with stool or blood were negative. All of the patients recovered completely without specific treatment. Conclusion: Infectious ileocecitis has acute appendicitis-mimicking symptoms, but is self-limited within a few days, thus unnecessary treatment and work-up is avoided. However, distinguishing infectious ileocecitis from appendicitis, inflammatory bowel disease, and mesenteric lymphadenitis is important.

Effect of Matrigel for Bone Graft using Hydroxyapatite/Poly $\varepsilon$-caprolactone Scaffold in a Rat Calvarial Defect Model (랫드의 두개골결손부 모델에서 HA/PCL 지지체를 사용한 골이식 시 Matrigel의 효과)

  • Kim, Se-Eun; Shim, Kyung-Mi;Kim, Seung-Eon;Choi, Seok-Hwa;Bae, Chun-Sik;Han, Ho-Jae;Kang, Seong-Soo
    • Journal of Veterinary Clinics
    • /
    • v.27 no.4
    • /
    • pp.325-329
    • /
    • 2010
  • The osteogenic potential of hydroxyapatite/poly $\varepsilon$-caprolactone composite (HA/PCL) scaffolds with matrigel was evaluated in a rat calvarial defect model. Calvarial defect formation was surgically created in Sprague Dawley rats (n = 18). HA/PCL scaffold was grafted with matrigel (M-HA/PCL group, n = 6) or without matrigel (HA/PCL group, n = 6). A critical defect group (CD group, n = 6) did not received a graft. Four weeks after surgery, bone formation was evaluated with radiography, micro computed tomography (micro CT) scanning, and histologically. No bone tissue formation was radiographically evident in the CD group. Bone tissue was radiographically evident in the HA/PCL and M-HA/PCL groups, however, there was more bone-similar opacity in the M-HA/PCL group. Micro CT analysis revealed that the bone volume of the M-HA/PCL group was higher than the HA/PCL group, however, no significant difference was found between the HA/PCL and M-HA/PCL groups. Bone mineral density in the M-HA/ PCL group was significantly higher than in the HA/PCL group (p < 0.05). Histologically, new bone was formed only from existing bone in the CD group, showing concavity without bone formation in the defect. In the HA/PCL group, new bone formation was only derived from existing bone, while in the M-HA/PCL group the largest bone formation was observed, with new bone tissue forming at the periphery of existing bone and around the HA/PCL scaffold with matrigel. The results indicate that the combination of HA/PCL scaffold with matrigel may be an effective means of enhancing bone formation in critical-sized bone defects.

The Characteristics of Eosinophilc Lung Diseases Cause by Toxocara Canis Larval Infestation (개회충 유충 감염에서 발생되는 호산구성 폐질환의 특성)

  • Kim, Yu Jin;Kyung, Sun Young;An, Chang Hyeok;Lim, Young Hee;Park, Jung Woong;Jeong, Seong Hwan;Lee, Sang Pyo;Choi, Dong Chull;Jeong, Young Bae;Kang, Shin Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.1
    • /
    • pp.19-26
    • /
    • 2007
  • Background: Toxocariasis is a common cause of eosinophilia and eosinophilic lung disease in Korea. We analyzed the characteristics of eosinophilic lung disease in toxocariasis. Method: One hundred and forty one patients with eosinophilia caused by a toxocara larval infection were evaluated from September 1, 2001 through March 30, 2006. The plain chest x-ray, chest CT(computed tomography), and bronchoalveolar larvage(BAL) were examined. A diagnosis of toxocariasis was made by ELISA using that secretory-excretory antigen from the T. canis larvae. Results: Toxocarial eosinophilic lung diseases was diagnosed in 32 out of 141 patients. Ground glass attenuation was the main feature on the CT scans in 23 out of 141 patients (71.9%). Thirteen patients (40.6%) had a random in zonal distribution on CT. Pleural effusion was observed in 9 patients (28.1%). Twenty eight patients (87.5%) complained of respiratory symptoms. Eleven patients (34.4%) had gastrointestinal symptoms and 12 patients (37.5%) had liver infiltration. Conclusions: The most common findings of the chest CT in patients with toxocariasis was a randomly distributed ground grass attenuation. A toxocara infection should be considered in a differential diagnosis of patients who exhibit pulmonary infiltration with eosinophilia in Korea.